Key Pages of Document

G (l/min) (gpm)

10 2 3 5 20 0.1 1 0.2 0.3 0.5 (psi) (bar) 10 2 3 5 20 1 0.5 10 2 5 20 0.01 0.1 0.02 0.03 0.05 1.0 0.2 0.3 0.5 4 0.4 0.4 4 0.04 0.4 0.3 Δ Use The Caleffi 5213 series is a thermostatic mixing valve suitable for single or multiple point of use applications in accordance with installation ru ...

The following instructions must be read prior to the installation of a Caleffi 5213 series thermostatic mixing

CALEFFI 521352A valve. The installer should also be aware of his responsibility and duty of care to ensure that all aspects of the installation comply with current regulations and legislation. The Caleffi 5213 series should be installed using the appro ...

View of temperature adjustment

CALEFFI 521352A Attaching temperature adjustment cap Temperature adjustment cap in place Locking adjustment spindle with locking nut 1 2 3 4 12 ...

CALEFFI 521352A 7 Replacement fittings Complete kit Valve size Connection Union Nut Tailpiece Washer consult Caleffi 3/8 inch compression F61008/C F0000718(2) F50055 NA20640 ½ inch NPT male R31981 NA20640C (1) 59893A(1) NA20649 Sweat NA10002(1) NA20649C 59904A NA20647 PEX crimp F0000492 NA20647C NA10484(1) NA20650 ¾ inch NPT male 31901A NA20650C 59840A(1) NA20659 Sweat NA ...

Point of use

Multiple use Multiple use with sensor faucet ...

In service tests should be conducted regularly to monitor and record the performance of the valve.

CALEFFI 521352A Deterioration in performance can indicate the need for servicing of the valve and/or water supply. If, during these tests, the mixed water temperature has changed significantly from the previous test results, record the change before re-adjusting th ...

Upon completion of the installation, the valve should be tested and commissioned as per the

CALEFFI 521352A procedure outlined below or as specified by the local authority. The following instructions should be read and understood prior to commissioning the Caleffi 5213 series thermostatic mixing valve. If, under any circumstances, there are aspects of the inst ...

ATTENTION: Lorsque vous effectuez les raccordements d'eau, assurez-vous

que la tuyauterie reliant le termostatico regolabile n'est pas mécaniquement des overstressed. Au fil du temps, ceci pourrait causer des ruptures, avec pour consequence des pertes en eau qui, à leur tour, peuvent causer des dommages à la propriété et/ou les gens. Ce symbole d'averti ...

½" NPT male

CALEFFI 521352A 2 13/16" 5 11/16 " 4 5/16" 3" 1 15/16" 2.0 521352A ¾" NPT male 2 13/16" 5 11/16 " 4 5/16" 3" 1 15/16" 2.0 521362A 1" NPT male 2 15/16" 5 7/8" 5 3/16" 3 ¼" 1 15/16" 2.0 521347A ½" PEX crimp 3" 6" 5½" 3 5/8" 1 15/16" 2.0 521357A ¾" PEX crimp 3" 6" 5 ...

1 Protective cap

CALEFFI 521352A 2 Temperature spindle locking nut 3 Upper body 4 O-ring seal 4a O-ring seal 5 Thermostatic element 6 Flow conveyor 7 Lower spring 8 Valve body 9 Union washer, quantity 3 per valve 10 Union nut, quantity 3 per valve 11 Inlet port male tailpiece with integral chec ...

CALEFFI 521352A user guide recommended for: 676 Series, 528 Series, AIR190013, 574 series, 2527 Series.