Hunter Stoves Di Lusso Series Installation, Operation, Maintenance And Servicing Manual

File Specifications

Brand: Hunter Stoves
Category: Stove
Model: Di Lusso Series (Installation, Operation, Maintenance And Servicing Manual), prBZp3Ll5H5/k
File Info: Adobe Acrobat PDF (DjVu)
File Size: —
Pages: 46 pages

Download PDF

Download Hunter Stoves Di Lusso Series Manual (46 pages)

Read Online:

Read the Hunter Stoves Di Lusso Series Installation, Operation, Maintenance And Servicing Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

ECO R4 INSET (FOUR-SIDED FRAME)

ECO R4 INSET (THREE-SIDED FRAME) STOVE - EDDLR04 STOVE – EDDLR04 FRAME – DLR4FP4B50 (BLACK) FRAME – DLR4FP3B50 (BLACK) FRAME – DLR4FP4P50 (PEWTER) FRAME – DLR4FP3P50 (PEWTER) ECO R5 INSET (FOUR-SIDED FRAME) ECO R5 INSET (THREE-SIDED FRAME) STOVE – EDDL ...

Creosote build-up in chimney

Hunter Stoves Di Lusso Series Wood with moisture content over 20% Use dry seasoned wood (less than 20% moisture content). Operate at a high temperature for short periods each time the appliance is used to avoid large build-ups of tars and creosotes. Tar coming from flue joints Appliance operated at continuous low tempe ...

IN THE EVENT OF A CHIMNEY FIRE -

• Raise the alarm • Call the Fire Brigade • Close appliance air controls • Move furniture, ornaments etc. away • Place a fireguard in front of stove • Check the chimney breast for signs of excessive heat. If the wall is becoming excessively hot, move furniture away. Ensure the Fire Brigade can gain access to you ...

Clearances To Combustible Materials

Hunter Stoves Di Lusso Series There should be no combustible materials for a distance of 450mm either side of the stove or 750mm above. No combustible furniture should be placed any closer than 1100mm from the front of the stove. Allow sufficient clearance between the stove and pictures, electrical equipment or ornaments etc., as these could be dama ...

Re-Assembling The Stove

Hunter Stoves Di Lusso Series ECO R4 1. Refit the base fixing access plate and gasket, Air Valve Cassette (with the air controls set to maximum), firebricks, brick baffle and log retainer. 2. Wind the M6 Nuts to the ends of the studs on the convection chamber sides. 3. Slide the Frame into position and tighten the nuts with a 10mm spanner. 4. Release the door l ...

The wall above the stove will become hot and should therefore be finished in a heat resistant plaster.

Hunter Stoves Di Lusso Series IMPORTANT Do not hang pictures, electrical equipment or ornaments above the stove, as these could be damaged and could potentially create a fire hazard. Please check the suitability of any fireplace/surround for closed solid fuel appliances before instal ...

ECO R5 Enclosure Details (all dimensions in millimetres)

Hunter Stoves Di Lusso Series Internal heat shield All panels including heat shield to be produced from 30mm Skamol Super Isol Board Internal heat shield N.B. Ventilation openings are identical on both sides of the enclosure ...

2. Remove the nuts, washers, secondary baffle plate and three M8 x 25mm studs located at either side of the

Hunter Stoves Di Lusso Series flue outlet. 3. Remove the Air Valve Cassette by removing the two fixing screws holding it in place, turning both air controls fully clockwise and gently pulling on the fascia to slide the cassette out from under the firebox. N.B DO NOT remove the A ...

7. Remove the Air Valve Cassette by removing the socket screw holding it in place, turning both air controls to

Hunter Stoves Di Lusso Series the fully open position (clockwise) and then gently pulling on the fascia to slide the cassette out from under the firebox. N.B. DO NOT Remove the Air Valve Cassette with the controls in the closed position as this will damage the valve gaskets. ...

The flue connection is made to the convection chamber and not to the firebox. The connection between the flue and

firebox is completed when the firebox is re-fitted to the convection chamber. Dependent on the type of installation, the flue collar may need to be connected to the convection chamber before or after installation of the flue/liner. 1. R ...

Hunter Stoves Di Lusso Series 3 CONTENTS INDEX: STOVE MODELS………………………………………………………………………………………………… 2 TECHNICAL SPECIFICATION……………………………………………………………………………… 4 GENERAL GUIDANCE………………………………………………………………………… ...

Hunter Stoves Di Lusso Series user guide recommended for: Inglenook CEV. II, herald 8 mk 2, Herald 8 Slimline CE, HS Gas SELENE 6 D, Telford Inset 20DB CVWSTI08DBFM.

⚠️ Download Safety

The Stove Installation, operation, maintenance and servicing manual (46 pages) is completely safe to download (last scan date: 28/06/2026).

Related PDF Instructions for Hunter Stoves Di Lusso Series:

Stove Equipment: Frequently Requested

Have some Questions about Hunter Stoves Di Lusso Series Device?