Datalogic Controller SC6000 Installation Manual

File Specifications

Brand: Datalogic
Category: Measuring Instruments
Model: Controller SC6000 (Installation Manual), prIpMV428KnnM
File Info: Adobe Acrobat PDF (DjVu)
File Size: —
Pages: 22 pages

Download PDF

Download Datalogic Controller SC6000 Manual (22 pages)

Read Online:

Read the Datalogic Controller SC6000 Installation Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

2.7 REDS PARAMETERS CONFIGURATION

2.7.1 Master Working Controller REDS configuration After the Net and Scanner setting, complete the Working configuration as follow: 1. Redundancy Parameters � Reds Functionality = checked. 2. Redundancy Parameters � Topology Redundancy = Master Working. 3. Data Communication settings � Built-in Ethernet � Line Parame ...

Standard: no diagnostic digital input information about the Standby system is reported:

Datalogic Controller SC6000 Input 1 = PS – No presence sensor signal for an interval that is too long Input 2 = ENC – No encoder signal for an interval that is too long Redundancy: diagnostic digital input information about the Standby system is reported. The digital input diagnostic information ...

3.9 DIAGNOSTIC ERROR MESSAGES

Datalogic Controller SC6000 3.9.1 SC6000 error message syntax: � WS#xxx where WS means Working Standby and xxx is the error number as listed in the table: � WA#xxx where WA means Working Active and xxx is the error number as listed in the table: � PS#xxx where PS means Protecting Standby and xxx is the error number as listed in the table: � PA#xxx ...

3.3 STANDBY-ACTIVE SWITCH OVER

The switch over is the situation that leads to a swapping of the role that the controllers play in the redundant system. The Standby controller is responsible for the decision to switch over as a final result of the evaluation of the local and remote diagnostics or of parcel error count conditions. This is how the switch over t ...

Datalogic Controller SC6000 user guide recommended for: DS4800, Arex 400, HF-CNTL-IND-02, Ulyxe PL, DX8200.

⚠️ Download Safety

The Measuring Instruments Installation manual (22 pages) is completely safe to download (last scan date: 02/04/2026).

Related PDF Instructions for Datalogic Controller SC6000:

Measuring Instruments Equipment: Frequently Requested

Have some Questions about Datalogic Controller SC6000 Device?