Absolute Process Instruments API 1600 G Manuals

1 pdf manual(s) Absolute Process Instruments API 1600 G for free download (Document Types: Manual )

Absolute Process Instruments API 1600 G Manual  [PDF] (2 pages)

  • Identifier: id-2242267
  • Brand: Absolute Process Instruments
  • Device: API 1600 G Transmitter
  • Type: PDF
  • Key Aspects: Step-by-Step Assembly Procedures, End-of-Life Handling and Disposal, Regulatory Compliance and Standards
  • UPD Date: 20.07.2026
  • Source File: 2045365.pdf
  • Pages: 2
  • Description: User instruction manual for the Absolute Process Instruments API 1600 G.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
AC Input Alarm Trips, Factory Ranged API 1600 G, API 1620 G Input: 0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-900 mAAC Output: One 8 Amp DPDT Relay or Two 8 Amp SPDT Relays Applications O Precision Internal AC/DC Converter O Field Adjustable Setpoints O Plug-In Design for Fast Installation O Input LoopTracker ® and Alarm Status LEDs O Alarm Test Button Q Process Limit Backup Alarm Q Over, Under, Out-of-Range Voltage or Current Alarm Q Heater Break, Conveyor Jam Alarm Model Input Standard Alarm Configuration Power API 1600 G Factory ranged, specify AC voltage, mV or mA current range Single setpoint one DPDT relay HI alarm, normal acting 115 VAC API 1600 G A230 230 VAC API 1600 G P 85-265 VAC or 60-300 VDC API 1600 G D 9-30 VDC API 1620 G Factory ranged, specify AC voltage, mV or mA current range 2 setpoints, 2 SPDT relays HI/LO alarms, normal acting 115 VAC API 1620 G A230 230 VAC API 1620 G P 85-265 VAC or 60-300 VDC API 1620 G D 9-30 VDC AC Input Range Factory configured, please specify AC input range Voltage: 0-50 mVAC to 0-300 VAC Current: 0-1 mAAC to 0-900 mAAC System voltages must not exceed socket voltage rating Input Impedance (Voltage Input) 220 kΩ minimum Input Voltage Burden (Current Input) 1.0 VRMS maximum Input Frequency 40 Hz to 1000 Hz sinusoidal Input Protection, Common Mode 750 VDC or 750 VACp LoopTracker Variable brightness LED indicates input level and status API 1600 G Relay Output Two SPDT form C contact sets operating in unison as one DPDT contact set One setpoint, 12 turn potentiometer, 0-100% of span Factory configured alarm type Normal acting alarm Standard: HI alarm Optional: LO alarm API 1620 G Relay Output Two independent SPDT form C contact sets Two setpoints, two 12 turn potentiometers, 0-100% of span Normal acting alarms Standard: HI/LO alarm Options: LO/LO, HI/HI, LO/HI alarms Internal jumpers for HI/LO, LO/LO, HI/HI, LO/HI Relay Contact Rating 8 A @ 240 VAC resistive load or 30 VDC resistive load See graph on other side for relay load ratings Caution: Do not exceed socket voltage rating Use an RC snubber for inductive loads Deadband Alarm trip/reset window are symmetrical about the setpoint API 1600 G 1.0 to 100% of span, 12 turn potentiometer API 1620 G Fixed at 1% of span, standard API 1620 G A Adjustable deadbands, 1.0 to 100% of span, 1 turn potentiometer for each setpoint Output Test Button Toggles relay(s) to opposite state when pressed Response Time 70 milliseconds typical Ambient Temperature Range and Stability –10°C to +60°C operating ambient Better than ±0.02% of span per °C stability, calculated, not tested Housing and Sockets IP 40, requires installation in panel or enclosure API 011 or API 011 FS socket Socket mounts to 35 mm DIN rail or can be surface mounted Power Standard: 115 VAC ±10%, 50/60 Hz, 2.5 W max. P option: 85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W typ. A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max. D option: 9-30 VDC, 2.5 W typical Options—add to end of model number L 1600 G with LO trip. Alarm trips on decreasing signal. HH 1620 G with HI/HI trip. Alarms trip at their respective trip points on increasing signal. LL 1620 G with LO/LO trip. Alarms trip at their respective trip points on decreasing signal. LH 1620 G with LO/HI trip instead of HI/LO. A 1620 G with adjustable deadbands. U Conformal coating for moisture resistance Accessories—order as a separate line item API 011 11-pin socket, DIN rail or surface mount API 011 FS 11-pin finger safe socket, DIN rail or surface mount API CLP1 Module hold-down spring for high vibration or mobile applications Description The API 1600 G and API 1620 G are factory configured for an AC voltage or current input and provide alarm contact outputs. Heavy duty relay contacts allow the module to directly control high capacity loads. The API 1600 G provides a single setpoint adjustment and DPDT relay contacts. The alarm output is normal acting and can be factory configured for HI or LO operation. Top- accessible potentiometers are used to adjust the alarm setpoint and deadband. The API 1620 G contains two independent setpoints with two SPDT relay contact outputs. The alarm outputs are normal acting can be factory or user configured for HI/HI, HI/LO, LO/HI or LO/LO operation. Top-accessible potentiometers are used to adjust each alarm setpoint. Deadband is fixed at 1% of span. Adjustable deadbands are optional. LoopTracker and Alarm Status LEDs API exclusive features include a LoopTracker LED that varies in intensity with changes in the input signal. A red/green bi-color alarm status LED (two on the API 1620 G) visually indicate alarm status. These LEDs provide a quick visual picture of your process at all times. Output Test API’s exclusive functional test button can be used to verify the alarm and system operation. Press the Test button to toggle the alarm relay(s) to the opposite state. The output test but- ton greatly aids in saving time during initial startup and/or troubleshooting. Free Factory I/O Setup! Quick Link api-usa.com/1600 API 1600 G Variable Brightness Input LED Bi-Color Relay LED Deadband Adjustment Setpoint Adjustment Output Test Button 2.38" 1.75" API 1620 G A Option Deadband Adjustments 2.38" 1.75" Variable Brightness Input LED Bi-Color Relay 2 LED Bi-Color Relay 1 LED Setpoint 2 Adjustment Setpoint 1 Adjustment Output Test Button API 1620 G P 001 001 115 VAC Your Required Input Your Alarm Configuration 2.75" H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H Made in USA Hot Swappable Plug-In Design API 011 300 V Rating API 011 FS 300 V Rating API CLP1 © 09-21 api-usa.com 1220 American Way Libertyville, IL 60048 Phone: 800-942-0315 Fax: 800-949-7502 ABSOLUTE BSOLUTE P PROCESS ROCESS I INSTRUMENTS NSTRUMENTS

API 1600 G: Related Instructions

IsoSplitter APD 3393
Absolute Process Instruments IsoSplitter APD 3393
23.03.2026 2 pages

IsoSplitter® Potentiometer to DC Signal Splitter/Isolator/Transmitter, Factory Ranged APD 3393 1 Input: 100 Ω to 1 MΩ Potentiometer 2 Outputs: 0-1 V to 0-1 Professional manual for the Absolute Process Instruments IsoSplitter APD 3393 Media Converter. The guide covers usage and operating instructions, technical guidelines, usage examples.

Cecomp F16LSC
Absolute Process Instruments Cecomp F16LSC
18.04.2026 4 pages

Cecomp® 2-Wire Loop Powered Digital Pressure Transmitters with Display Backup F16LSC, F16LSCN Ranges and Resolution See table below. Consult factory for specia Operation guide for the Absolute Process Instruments Cecomp F16LSC Transmitter. It explains shutdown procedures, connectivity options, installation guides, product maintenance.

IsoSplitter APD 4930
Absolute Process Instruments IsoSplitter APD 4930
11.07.2026 2 pages

Options—add to end of model number M19 Channel 1 high voltage output (>10 to 20 VDC max.) M29 Channel 2 high voltage output (>10 to 20 VDC max.) M39 Channel 1 Professional operation guide for the Absolute Process Instruments IsoSplitter APD 4930 Media Converter. This documentation guides on network setup, reset instructions, error handling, user settings.

APD 4008
Absolute Process Instruments APD 4008
18.07.2026 3 pages

Potentiometer Input to DC Transmitters, Isolated, Field Rangeable APD 4008 Input: 100 Ω to 1 MΩ Potentiometers, 0 to 90% Offset Output: 0-1 V to ±10 VDC, o Instruction guide for the Absolute Process Instruments APD 4008 Transmitter. It explains security instructions, product maintenance, diagnostic information.

DuoPak APD 2055
Absolute Process Instruments DuoPak APD 2055
05.05.2026 2 pages

api-usa.com 1220 American Way Libertyville, IL 60048 Phone: 800-942-0315 Fax: 800-949-7502 BSOLUTE ROCESS NSTRUMENTS, Inc. © 11-16 Removable Plugs Dimensions 1 Device instruction guide for the Absolute Process Instruments DuoPak APD 2055 Media Converter. This guide presents instructions on operating conditions, device operation tips, operating guidelines.

DuoPak APD 2033
Absolute Process Instruments DuoPak APD 2033
03.07.2026 2 pages

api-usa.com 1220 American Way Libertyville, IL 60048 Phone: 800-942-0315 Fax: 800-949-7502 BSOLUTE ROCESS NSTRUMENTS, Inc. © 05-16 Removable Plugs Dimensions 1 Instruction reference guide for the Absolute Process Instruments DuoPak APD 2033 Media Converter. It outlines the setup and device overview, system configuration, usage tips, user preferences.

Similar Manuals in the Transmitter Category

8051
Aprilaire 8051
24.06.2026 2 pages

Model 8051 Flush Mount Sensor Installation Instructions Introduction Installation Instructions The 8051 is a temperature sensor. It can be used to remotely meas Maintenance instructions for the Aprilaire 8051 Transmitter. This documentation details installation steps, product safety, connectivity options.

EE650
E+E Elektronik EE650
23.03.2026 7 pages

GENERAL The EE650 transmitter is designed for accurate measurement of air velocity in HVAC. It operates on the hot-film anemometer principle and features the in Installation reference manual for the E+E Elektronik EE650 Transmitter. The manual details functional overview, operational safety, hardware setup.

TT Series
Hampshire Controls TT Series
27.07.2026 22 pages

TEMPERATURE TRANSMITTER OPERATING INSTRUCTIONS HAMPSHIRE CONTROLS CORPORATION PO Box 516, Dover NH 03821 Tel (603) 749-9424 Toll-free (866) 496-9424 Fax (603) User reference manual for the Hampshire Controls TT Series Transmitter. The document guides users through performance details, service contacts, operating guidelines, assembly reference.

OmniiCopper Vi27000 Series
Vigitron OmniiCopper Vi27000 Series
01.08.2026 2 pages

Application Drawing Vi27000/Vi27001 Single-Pair Ethernet & PoE Transmission Solution Installation Manual DO NOT OPEN RISK OF ELECTRIC SHOCK CAUTION CAUTION: TO Product instruction handbook for the Vigitron OmniiCopper Vi27000 Series Extender. It explains maintenance and power management, compatibility information, system checks, installation procedures.