AKG C 12VR Manuals

2 pdf manual(s) AKG C 12VR for free download (Document Types: Specifications, User instructions)

AKG C 12VR Specifications [PDF] (2 pages)

  • Identifier: id-112164
  • Brand: AKG
  • Device: C 12VR Microphone
  • Type: PDF
  • Key Aspects: Standard Operating Procedures, Routine Functionality Testing, Component Longevity Optimization
  • UPD Date: 06.09.2026
  • Source File: 17932.pdf
  • Pages: 2
  • Description: Product usage guide for the AKG C 12VR.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
C 12VR Tube Condenser Microphone Description The AKG C 12 VR (Vintage Reissue) is the modern equivalent to the classic C 12 produced beginning in 1953. The C 12 VR continues to set the standard for quality, providing its famed warmth and presence, which are direct results of its unique tube (6072), diaphragm and transformer design. Internal microphone switching is provided for pre- attenuation of -10 dB, -20 dB, and +10 dB boost. The available pick up patterns include omnidirectional, cardioid, and figure-eight with six intermediate patterns. The nine remotely selectable pickup patterns make the C 12 VR a necessity not only for vocals, but for instrumental solo recording, as well. The C 12 VR comes with its own professional flight case, power supply (N 12 VR), elastic suspension (H 15/T), 30 ft. multi-conductor connecting cable (MK 12 VR), and foam windscreen (W 42). Features • Classic 1-inch (25 mm) condenser tube performance of the original AKG C 12 • Multiple patterns (nine total) remotely controlled with silent switching • Uses the original 6072 vacuum tube • Uses the original 1950’s dual diaphragm design for sound that has the same warmth, clarity and presence of the original • Internal microphone switching for pre-attenuation of -10, -20 dB and boost of +10 dB to accommodate all studio requirements. • External (in control unit) two-position bass cut/roll-off Specifications Transducer type: Dual diaphragm, 1 in. (25 mm) diameter Diaphragm material: Gold sputtered mylar foil. Frequency response: 30 Hz - 20 kHz (±2.5 dB from published curves) Polar patterns: Omnidirectional, cardioid, and figure-8, with 6 intermediate patterns (silent switching) Impedance: 200 ohms (±25%) Recommended load impedance: 1000 ohms or greater Output connector (from control unit): XLR (pin 2 positive) Output connector (from microphone): Tuchel 12-pin Sensitivity at 1 kHz: 10 mV/Pa for all patterns; -40 dB (dB re 1 V/Pa) Equivalent noise level (A-weighted): 22 dB (DIN 45412) Sound pressure level for 3% THD: 128 dB (equivalent to 50 Pa) Pre-attenuation: -10 and -20 dB (at microphone) Sensitivity increase: 10 dB (at microphone) Low frequency roll-off/bass cut: two-position (at control unit) Power requirement: 115/230 Vac Microphone size: 1.65 in. dia (42 mm) 8.9 in. long (225 mm) Microphone net weight: 24 oz. (0.68 kg) Shipping weight: 10 lb. (4.5 kg) Accessories included: Aluminum flight case N 12 VR remote power supply H 15/T elastic suspension MK 12V R 30 ft. (10 m) connecting cable W 42 Foam windscreen

AKG C 12VR User instructions [PDF] (28 pages)

  • Identifier: id-112163
  • Brand: AKG
  • Device: C 12VR Microphone
  • Type: PDF
  • Key Aspects: Error Code Explanations, Device Specifications Overview, Warranty and Service Information
  • UPD Date: 03.08.2026
  • Source File: 17931.pdf
  • Pages: 28
  • Description: Detailed product documentation for the AKG C 12VR.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
C 12 VR Bedienungshinweise User Instructions Mode d‘emploi Istruzioni d’uso Modo de empleo Instruções de Uso (EMC, LVD)

AKG C 12VR: Microphone Category Related Instructions

US-902D Pro
JTS US-902D Pro
25.03.2026 28 pages

Setup and usage guide for the JTS US-902D Pro Microphone. It describes operating procedures and firmware installation, operation, technical specifications, energy usage.

LCT 540 S
Lewitt LCT 540 S
29.07.2026 2 pages

QUICKSTART GUIDE // LCT 540 S // User Interface Status indicator // Illuminated white: standard operation Flashing red: clipping occurs Not illuminated: key-lock active Illuminated red: Automatic Attenuation active Flashing white and red: Clipping History acti User guidebook for the Lewitt LCT 540 S Microphone. The manual provides technical details on operational procedures, maintenance, system parameters, troubleshooting tips.

Unipoint U841A
Audio Technica Unipoint U841A
10.08.2026 1 pages

• Designed for surface-mount applications such as high- quality sound reinforcement, professional recording, television, conferencing and other demanding sound pickup situations • UniGuard™RFI-shielding technology offers outstanding rejection of radi Product usage guide for the Audio Technica Unipoint U841A Microphone. It explains operation, maintenance, and power requirements, installation guides, troubleshooting tips, usage procedures.

MK 8
Sennheiser MK 8
25.07.2026 2 pages

Sennheiser electronic GmbH & Co. KG Am Labor 1, 30900 Wedemark, Germany www.sennheiser.com Printed in Germany, Publ. 12/20, 857474/A01 MK 8 Quick Guide Kurzanleitung Guide de démarrage rapide Guida rapida Instrucciones resumidas Instruções resumidas Beknopt Technical operations guide for the Sennheiser MK 8 Microphone. It describes usage and user preferences, hardware setup, setup guidelines, operational guidelines.