Alpha FlexPoint 1208-F Manuals
2 pdf manual(s) Alpha FlexPoint 1208-F for free download (Document Types: Quick start manual)
Alpha FlexPoint 1208-F Quick start manual [PDF] (2 pages)
- Identifier: id-1290514
- Brand: Alpha
- Device: FlexPoint 1208-F Power Supply
- Type: PDF
- Key Aspects: Technical Support and Resource Links, Package Contents and Accessories List, Risk Mitigation and Accident Prevention
- UPD Date: 28.07.2026
- Source File: 1297188.pdf
- Pages: 2
- Description: Technical reference manual for the Alpha FlexPoint 1208-F.
Click to expand and read text
7.48" [190.0 mm] 3.19" [81.0 mm] 4.23" [107.4 mm] 6.57" [166.9 mm] 2.52" [64.0 mm] 2.83" [71.9 mm] 4.29" [108.9 mm] 3.23" [82.0 mm] (Cover removed for clarity) FlexPoint™ 1208-F Quick Start Guide FTTx UPS System for ONTs Fig. 1, System Block Diagram Review the drawings and illustrations contained in this guide before proceeding. For additional details on installation and operation, visit www.alpha.com and download a copy of the FlexPoint TM 1208-F Series Technical Manual (p/n 010-353-B0). The FlexPoint 1208-F unit is an RFoG power supply providing 12Vdc primary and standby power. A customer- provided 90Vac to 264Vac, 50/60Hz power receptacle provides primary power to the input of the unit. The AC voltage is then converted to a usable 12Vdc output. Backup power is provided by batteries that are long life, easy to replace, purchase, and install. Power status is provided to the customer via audible alarms and visual indicators. Upon loss of AC service, the duration of standby power is determined by the battery installed in the unit. 1. Unpack and inspect the FlexPoint power supply. 2. Install the unit within 8' (2.4 m) to an AC outlet with 6" (15.2 cm) of space above and below, 2–4" (5–10 cm) in front and 2" (5 cm) of space on either side to provide adequate thermal ventilation. 3. Remove battery compartment cover by pressing the finger tab underneath the middle of the unit and pull the cover bottom away from the unit and down. 4. Determine the necessary cable length to provide appropriate service loops between the unit, the ONT, and the AC receptacle. Plug the line cord into the receptacle in the unit. Secure line cord at one of the cable tie holes with one included cable tie. Do not plug the unit into an AC receptacle until the last step of the installation procedure. 5. Connect Coax cable to F-type connector, torque to between 4.1 in-lbs and 6.1 in-lbs, and secure in cable dressing holes. Secure output cable at one of the cable tie holes with one of the included cable ties. 6. Mount to the wall with #12 fasteners or equivalent, using the keyholes for easy mounting. For applications with higher seismic requirements, use the round hole in the back of the unit for direct fastening to a stud or other structural feature. Installing and Connecting the FlexPoint Unit • The unit is designed for use in an indoor environment protected from rain and snow. Its operating temperature range is -10°C to 45°C / 14°F to 113°F (ambient). • The power supply cord is used as the main disconnect device. Verify the AC receptacle is located/installed near the equipment and is easily accessible. CAUTION! 1 ONT Line Cord Up to 8', (2.4 meters) Network Area Customer Area FlexPoint 1208-F Coaxial Cable w/ F-Type Connector FlexPoint: Up to 50' (~15.25 meters) AUX SILENCE ALARM DC START Alpha Technologies 3767 Alpha Way Bellingham, WA 98226 USA Tel: +1 360 647 2360 Fax: +1 360 671 4936 www.alpha.com Alpha Technologies Ltd. 7700 Riverfront Gate Burnaby, BC, V5J 5M4 CANADA Tel: +1 604 436 5900 Fax: +1 604 436 1233 Due to continuing product improvements, Alpha reserves the right to change specifications without notice. Copyright 2014 Alpha Technologies, Inc. All rights reserved. Alpha is a registered trademark of Alpha Technologies. 010-353-B8-001 Rev. A1 Fig. 2, FlexPoint Dimensions (in/[mm]) (viewed from back/right side) Fig. 3, FlexPoint AC/Output Power Connector Locations Mounting holes for customer-supplied #12 hardware or equivalent Keyhole slots for easy mounting Cable Dressing Holes 1 2 Always mount unit vertically as shown in Fig. 2. NOTICE: Table 1, FlexPoint Battery Options Table 2 2 1 Battery Options Part Description AX-STDBAT-5 Battery 5.1Ah AGM, 1-year Warranty AX-STDBAT-7 Battery 7.2Ah AGM, 1-year Warranty AX-LONGBAT-7 Battery 7.2Ah AGM, 3-year Warranty AX-LONGBAT-8 Battery 8Ah AGM, 3-year Warranty Coaxial Connector AC Connector During normal operation, press the Silence Alarm button to get the recommended battery capacity: 5Ah – 1 chirp; 7Ah – 3 chirps; 8Ah – 4 chirps. NOTICE:
Alpha FlexPoint 1208-F Quick start manual [PDF] (2 pages)
- Identifier: id-1858767
- Brand: Alpha
- Device: FlexPoint 1208-F Power Supply
- Type: PDF
- Key Aspects: Cleaning and Sanitization Methods, Error Code Explanations, Periodic Inspection Checklists
- UPD Date: 29.05.2026
- Source File: 1863995.pdf
- Pages: 2
- Description: User support manual for the Alpha FlexPoint 1208-F.
Click to expand and read text
1 FlexPoint™ 1208-F / 1232-D / 1250-D Power Supplies Quick Start Guide Fig. 1, System Block Diagram Review the drawings and illustrations contained in this guide before proceeding. For additional details on installation and operation, visit www.alpha.com and download a copy of the FlexPoint TM 1208-F / 1232-D / 1250-D Series Technical Manual (p/n 010-353-B9). The FlexPoint 1232-D and 1250-D power supplies are designed to provide power to both an optical network terminal (ONT) and a micro-node. These power supplies are able to provide a total of 32W and 50W (respectively), via the 7-pin connector. When the F-type connector is used in conjunction with the 7-pin connector, power will be split between outputs with a maximum of 8W delivered via the coaxial connector, and the balance of the unit’s power available on the 7-pin connector. A customer-provided 90Vac to 264Vac, 50/60Hz power receptacle provides primary power to the input of the unit. The AC voltage is then converted to a usable 12Vdc output. Backup power is provided by batteries that are long life, easy to replace, purchase, and install. Power status is provided to the customer via audible alarms and visual indicators. Upon loss of AC service, the duration of standby power is determined by the battery installed in the unit. 1. Unpack and inspect the FlexPoint power supply. 2. Install the unit within 8' (2.4 m) to an AC outlet with 6" (15.2 cm) of space above and below, 2–4" (5–10 cm) in front and 2" (5 cm) of space on either side to provide adequate thermal ventilation. 3. Remove battery compartment cover by pressing the finger tab underneath the middle of the unit and pull the cover bottom away from the unit and down. 4. Determine the necessary cable length to provide appropriate service loops between the unit, the ONT, and the AC receptacle. Plug the line cord into the receptacle in the unit. Secure line cord at one of the cable tie holes with one included cable tie. Do not plug the unit into an AC receptacle until the last step of the installation procedure. 5. Connect coax cable to F-type connector, torque to between 4.1 in-lbs and 6.1 in-lbs, and secure in cable dressing holes. Secure output cable at one of the cable tie holes with one of the included cable ties. 6. Mount to the wall with #12 fasteners or equivalent, using the keyholes for easy mounting. For applications with higher seismic requirements, use the round hole in the back of the unit for direct fastening to a stud or other structural feature. Installing and connecting the FlexPoint unit • The unit is designed for use in an indoor environment protected from moisture. Its operating temperature range is -10°C to 45°C / 14°F to 113°F (ambient). • The power supply cord is used as the main disconnect device. Verify the AC receptacle is located/installed near the equipment and is easily accessible. CAUTION! ONT Line Cord Up to 8', (2.4 meters) Network Area Customer Area FlexPoint 1208-F F-Type Connector FlexPoint: Up to 50' (~15.25 meters) AUX SILENCE ALARM DC START During normal operation, press the Silence Alarm button to get the recommended battery capacity: 5Ah – 1 chirp; 7Ah – 3 chirps; 8Ah – 4 chirps. NOTICE: FlexPoint specifications Input AC Input Voltage: 90–264Vac AC Input Frequency: 50/60Hz Connection: IEC 320-C6 3-Prong with cable ties to prevent accidental removal of the line cord. Surge Protection: Standards Level Telcordia GR-1089 ANSI/IEEE C62.41 IEC 61000-4-5 1.2x50us combination wave at, 2kV Output per model 1208-F 1232-D 1250-D Operational Output Power (ONT Load): 8W max. continuous 32W max. continuous 50W max. continuous Output Voltage: 12Vdc nominal 12Vdc nominal 12Vdc nominal Connection: RF connector 7-position connector and F-type coaxial connector 7-position connector and F-type coaxial connector Mechanical Dimensions Unit Dimensions for 5,7.2 or 8Ah Battery L x W x D (in/mm): 6.6 x 7.5 x 3.2 / 167.6 x 190.5 x 81.3 Unit Weight without Battery (lb/kg): 1.2 / 0.54 1.3 / 0.59 1.35 / 0.61 5.1Ah Battery Weight (lb/kg): 3.9 / 1.8 7.2Ah Battery Weight (lb/kg): 5.7 / 2.6 8.0Ah Battery Weight (lb/kg): 5.73 / 2.7 Estimated Battery Runtimes 1208-F 1232-D 1250-D 1.5W load 4W load 16W load 32W load 36W load 50W load 5.1Ah Battery (Hrs): 34.2 12.7 2.5 1.1 0.9 0.7 7.2Ah Battery (Hrs): 54.4 20.0 3.9 1.6 1.4 1.0 8.0Ah Battery (Hrs): 60.7 22.4 4.7 2.0 1.7 1.1 Battery Type: Maintenance free, leak-proof, sealed VRLA (valve regulated lead acid) Visual Indicators AC Power: Green LED on: AC power present and powering the ONT Battery: Green LED on: Battery powering ONT during AC loss Green Flashing: Battery powering ONT during AC loss and running low Replace Battery: Red LED off: Battery present and working correctly Red LED on: Replace battery / battery missing Mute Green LED on: Lit when Silence Alarm button is pressed Replace Power Supply: Green LEDs flashing Audible Status Indicators Loss of Input Power: Single, one second chirp Low Battery: Single chirp every 15 seconds Replace Battery: Double chirp every 15 minutes Push Buttons DC Start: Press and hold when unit is off to start up on battery without AC present Silence Alarm: When any audible alarm is on, press this key for at least 1 second and release to silence the audible alarm. During normal operation, press the Silence Alarm button to get the recommended battery capacity: 5Ah – 1 chirp; 7Ah – 3 chirps; 8Ah – 4 chirps. FlexPoint 1232-D, 1250-D 7-position output cable (Class 2 wiring) and an F-type Connector Alpha Technologies 3767 Alpha Way Bellingham, WA 98226 USA Tel: +1 360 647 2360 Fax: +1 360 671 4936 www.alpha.com Alpha Technologies Ltd. 7700 Riverfront Gate Burnaby, BC, V5J 5M4 CANADA Tel: +1 604 436 5900 Fax: +1 604 436 1233 Due to continuing product improvements, Alpha reserves the right to change specifications without notice. Copyright © 2015 Alpha Technologies, Inc. All rights reserved. Alpha is a registered trademark of Alpha Technologies. 010-353-B8-001 Rev. B (06/2015)
FlexPoint 1208-F: Related Instructions
1 010-353-B1-001, Rev. C (5/2019) FlexPoint™ 1215, 1232, 1250 Power Supplies Quick Start Guide Review the drawings and illustrations contained in this guide b Manual for installation and usage of the Alpha FlexPoint 1215 Power Supply. It details safety instructions and usage procedures, device calibration, power requirements, installation.
Operating manual for the Alpha AWS-125 Power Tool. This reference manual outlines specifications, adjustment procedures, functional overview, application scenarios.
User's Instructions Alpha CD25X/28X Alpha CD25X G.C. No. 47 532 39 Alpha CD28X G.C. No. 47 532 37 British Gas Service Listed For use with Natural Gas only Leave Service manual for the Alpha Alpha CD25X Gas boilers. It explains configuration options and connectivity options, calibration steps, user preferences.
INSTANT WATER HEATER QUICK INSTALLATION GUIDE (You are still required to refer to the instruction manual before installation) 1 Comprehensive guide for the Alpha MULTIPOINT Series Water Heater. The manual outlines technical specifications and safety guidelines, interface navigation, usage tips, specifications.
Essential instructions for the Alpha 240eco Boiler. This manual outlines troubleshooting guides, operational procedures, hardware instructions, safety information.
Installation Instructions KIT CONTENTS 1. GENERAL Note: These flues MUST ONLY be used with the Alpha Condensing boilers. a. The Alpha Easy-Flue is suitable for Product instruction handbook for the Alpha Alpha CD EasyFlue Boiler. The guide explains operation and hardware instructions, service contacts, daily usage.
Similar Manuals in the Power Supply Category
©1995, KEPCO, INC 228-1158 1 Data subject to change without notice I N S T R U C T I O N M A N U A L FAW KEPCO KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSH Instruction reference guide for the KEPCO FAW 5-20K Power Supply. It provides information on safety and testing procedures, operating modes, performance optimization.
Product usage manual for the Coolmax ZP-380B Power Supply. This manual covers performance optimization, device overview, performance guidelines.
Device instruction manual for the Alarm SAF PS5-12025-B07-UL/CSA/ULC Power Supply. This manual outlines service instructions, hardware components, replacement parts, basic operation.
Code : 180120008Ga - NDU : NOT120008Ha Edition : 0320 NOTICE D'UTILISATION P 1 OPERATING INS User operation guide for the SLAT AXS3 Power Supply. It provides guidance on usage examples, backup procedures, assembly reference, operational safety.