ATP Electronics FHB-600 Manuals

1 pdf manual(s) ATP Electronics FHB-600 for free download (Document Types: Instruction manual)

Available Documents for FHB-600:

ATP Electronics FHB-600 Instruction manual Main Page Preview

Instruction manual [PDF] (4 pages)

  • Brand: ATP Electronics
  • Model: FHB-600
  • Format: PDF
  • Key Aspects: User Training Recommendations, Storage and Care Recommendations, Unpacking and Inspection Guidelines
  • Updated: 24.05.2026
  • Source File: 958430.pdf
  • Pages: 4
  • Description: Device setup manual for the ATP Electronics FHB-600.

Document Preview & Text Transcription

FUNCTION SETTINGS 1. To change & set BAUD Rating, Parity & Print Mode Press [ON/OFF] to turn on the scale on. This display will show --------. As soon as you see --------, press [PRINT] and the display will show b xxx BAU value (BAUD Rate). Press [UNIT] to select 1200, 2400, 4800 or 9600. Press [ZERO] to enter Parity mode, the display will show P XXX PAR. Press [UNIT] to select odd, even or none (odd stands for 7 data bits with odd parity, even stands for 7 data bits with even parity, none stands for 7 data bits without parity). Press [ZERO] to enter Print mode. The display will show n xxx Mod. Press [UNIT] to select ON, OFF, KEY or STB (OFF stands for serial data output disabled, KEY stands for demand mode by pressing [PRINT], STB stands for automatic print when scale is stable and ON stands for continuous print. Press [ZERO] again to return to weighing mode. 2. To activate and deactivate weighing units Press [ON/OFF] to turn on the scale on. The display will show digits and then --------. As soon as you see -------- press [UNIT] to enter unit selection mode. The display will show ON X (X stands for the units i.e. g or oz). Press [ZERO] to select an unit and press [UNIT] to select ON (to activate the selected unit) or OFF (to de-activate the selected unit). Press [ZERO] until you return to weighing mode. 2. To change & set the Zero, Tare, Overload & Back Light settings Press [ON/OFF] to turn on the scale on. The display will show digits and then --------. As soon as you see -------- press [PCS]. Following the table below, use the [ZERO] button to enter each setting and [UNIT] button to change the value in each setting. Setting (shown as it is seen on the display) What setting you are changing What you can choose from ZRD X.X Zero Track Value 0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5 & 2.0 ZRT X.X Zero Track Time 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5 & 4.0 RZD X.X Zero Value 0.8, 1.8, 2.8 & 3.8 FIL X Filter Range 0, 1, 2, 3, 4, 5, 6 & 7 PZR XX Set percentage for zero range when the scale is first turned on 1, 2, 3, 4, 5, 8, 10 & 20 TZR XX Set percentage of zero range 3, 4, 5 & 10 TTR XXX Set percentage of tare range 50 or 100 OUR XX Overload Protection Mode 2, 5, 10 9d b2 XX Activate or deactivate beep when buttons are pressed ON or OFF ZT XX Unite tare & zero function ON or OFF A XXX Auto-power off settings 3, 5, 10mins or OFF L XXX Back Light settings AUTO, OFF or ON COMPACT SCALE/BALANCE INSTRUCTION MANUAL SAFETY PRECAUTIONS All safety messages are identified by the following the words "WARNING" and "CAUTION". These words mean the following: △WARNING Important information to alert you to a situation that might cause serious injury and damage to your scale if instructions are not followed. △CAUTION Important information that tells how to prevent damage to equipment. When using the scale/balance, the following safety precautions should always be followed. △ WARNING Use only the AC/DC mains adapter provided with the scale/balance. Other adapters may cause damage to the scale. Do NOT use the mains adapter while batteries are fitted inside this scale. It will result in permanent damage to the circuit board. △ CAUTION Avoid installing the scale/balance in direct sunlight; this may cause discoloration or malfunctions. Avoid overloading the scale; it could cause damage to the scale/balance. Do not allow the scale to come into contact with water; it is not water-proof. If water comes in contact with the circuit board it will damage the scale/balance. Avoid using the scale near anything that has electrically charged matter. Discharge the static electricity using an electrification prevention spray and spray on both sides of the weighing platform. 1 SPECIFICATIONS Model number Capacity Division FHB -600 600g 0.01g/0.005g FHB -3000 3000g 0.05g/0.1g FHB -6000 6000g 0.1g/0.2g Platter 120 x 135mm or 160 x 195mm Net/gross weight 1.8Kg Package Standard carton: 36.5x26x16(cm3) Operating Temperature 0-40℃(32-104℉) Power source AC/DC Adapter or Batteries Adapter 10V/500mA Parts Counting procedure 1. Press [ON/OFF] to turn on the scale. Wait for "0" to appear on the display. 2. Start the Count Procedure If necessary, press the [ZERO] key to set the display to “0”. 3. Press the [PCS] key to put the scale in parts counting mode, the display will show P=X X, press UNIT to select XX value (10, 20 ,50, 100) and place your sample on the platform of the scale/balance. 4. Press the [PCS] key, the display will show “XX pcs”, then the scale will recall the sample size you selected and show the starting sample size on the display. 5. You can now remove the samples if you want to return the scale to 0 & start counting. 6. Press the [PCS] key to return to the weighing mode 6 CALIBRATION When to calibrate Calibration may be required when it is initially installed or if the scale/balance is moved to a substantial distance. This is necessary because the weight of a mass in one location is not necessarily the same in another location due to gravity. Also, with time and use, mechanical deviations may occur. How to calibrate 1. Before entering calibration mode, there is a switch key on the bottom of the scale. Turn on the switch key first then press [ON/OFF] button on the front of the scale/balance to turn the power on and leave the scale/balance to warm up for 1 minute. 2. Enter calibration mode Press [ON/OFF] button to turn the power on. The display will show different digits and then “--------”. As soon as you see “--------” press [ZERO] twice, the display will show “CAL.” Press [ZERO] again, the display will show “X0000 CAL”; X indicates the digit flashing on the display. Press [UNIT] key the flashing digit will move to the right. Press [PCS] key to increase the flashing digit. (X is the calibration weight which can be set according to your requirements). 3. Calibration by the weight When you have entered the weight you wish to carry out the calibration with, place the calibration weight/s onto the platform of the scale/balance. Then press [ZERO] key, the display returns to the weighting mode. Remove the calibration weight and calibration is now complete. 4. Check the calibration has worked Press [ON/OFF] to turn the scale/balance off. Then press [ON/OFF] to turn the scale/balance back on. Place the weight on the platform and check that the scale/balance is weighing correctly, if not, repeat steps 2-4. 5 PARTS DESCRIPTION BACK AC adaptor Socket FRONT ·Key pad function 1. ON/OFF key: Turn the power on or off. 2. ZERO key: For zero setting of the scale up to 4% of the scales capacity (i.e. for a 600g capacity 4% would be 24g) 3. TARE key: Press this button to deduct the weight on the display (useful for containers) 4. PRINT key: To print the displayed data. 5. UNIT key: Press this button to select different weighing units. 6. PCS key: For parts counting function. DISPLAY Low battery indicator weighing unit TARE indicator Negative value indicator STABLE indicator Indicates when the reading is stable. ZERO indicator 2 PREPARATION 1. Installing batteries Batteries Battery compartment switch power 6 AA Batteries 2. Setting up the scale/balance △ ! CAUTION Avoid installing the scale/balance in direct sunlight it may cause discoloration or malfunctions. Place your scale/balance on a firm weighing table so that the scale/balance is level. (The scale/balance will not perform accurately when it is not level.) Place the scale/balance on a firm surface that is flat and level for an accurate reading. 3 WEIGHING Before weighing Turn the scale on and leave for 10 minutes to warm up before use Error messages Err-O: Overload Err-Z: Zero tracks has been exceeded Err- S: The scale is unstable : Low battery Weighing procedures 1. Press [ON/OFF] to turn on the balance. When the scale/balance is turned on, all display segments appear on the LCD display for a few seconds and finally "0" will appear on the display. 2. Select the weighing unit with [UNIT]. Press [UNIT] to select a weighing unit, e.g. g, ct, oz or dwt (there are 16 units to choose from) 3. Start weighing If you do not use a container for weighing Check that the display is showing 0. If not, press [ZERO]. Place objects on the weighing platform to weigh. When the reading becomes stable, the stable indicator is displayed. If you use a container for weighing Check that the display is showing 0. If not, press [ZERO]. Place an empty container on the platform. Wait for the stability indicator to be displayed and press [TARE]. Place the objects to be weighed in the container. When the reading becomes stable, the stable indicator is displayed. FEATURES  User calibration ● Auto shut off (selectable)  Auto zero tracking ● Auto backlight (selectable)  Recharge ●g/ct/oz/….. conversion  Large LCD Display ●counting function  Stability indicator  1/120000 & 1/200000 division available 4

FHB-600: Related Instructions

Manuals from Other Manufacturers