Braeburn 5300 Manuals

4 pdf manual(s) Braeburn 5300 for free download (Document Types: Installer's manual, Operation & user’s manual)

Braeburn 5300 Installer's manual [PDF] (10 pages)

  • Identifier: id-665660
  • Brand: Braeburn
  • Device: 5300 Thermostat
  • Type: PDF
  • Key Aspects: Common Issue Diagnostic Flows, Advanced Configuration Methods, Unpacking and Inspection Guidelines
  • UPD Date: 20.05.2026
  • Source File: 661761.pdf
  • Pages: 10
  • Description: Instructions for safe usage of the Braeburn 5300.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Heat Pump or 2 Heat / 2 Cool Conventional Thermostat Installer Guide Specifications Installation Quick Reference Programming Installer Settings Before Installing, Programming or Operating, PLEASE READ ALL INSTRUCTIONS 1 2 3 4 Testing Thermostat Wiring Diagrams 5 6 5300 SEE USER MANUAL FOR TROUBLESHOOTING WARNING Important Safety Information • Always turn off power to the air conditioning or heating system prior to Installing, removing, cleaning or servicing thermostat. • This thermostat is a dual power thermostat and either requires 24 Volt AC Power or two (2) properly installed “AA” Alkaline batteries for normal operation and control of the heating or cooling system. • Properly installed batteries will allow the thermostat to retain clock settings in the event of loss of AC Power due to power outage or rolling blackouts when used as a hardwired thermostat. • This thermostat should only be used as described in this manual. Any other use is not recommended and will void the warranty. 1 Specifications • Electrical Rating: 24 Volt AC (18-30 Volt AC) 1 amp maximum load per terminal 5 amp maximum load (all terminals) • Control Range: 45º - 90º F (7º C - 32º C) • Accuracy: +/- 1º F (+/- .5º C) • AC Power: 18-30 Volt AC • DC Power: 3.0 Volt DC (2 “AA” Alkaline batteries included) Specifications 1 cont. Replacing Existing Thermostat Installation 2 Old Terminal from Existing Thermostat New Terminal for New Thermostat (Model 5300) Terminal Description A A External Air output G or F G Fan Control Rc Rc 24 Volt AC (Cooling for Dual Transformer Systems) R, V-VR or VR-R Rh 24 Volt AC W1, W2 or W-U W2 Stage 2 Heating B B Reversing Valve (Heating) O or R O Reversing Valve (Cooling) Y, Y1 or M Y1 Stage 1 Compressor Y2 Y2 Stage 2 Compressor W1/E/W3 W1/E/W3 1st Stage Heating for Conventional Systems or Emergency Heating for 3 Stage Heat Pumps C, X or B C 24 Volt AC, Transformer Common L or X L System Malfunction Indicator S1 S1 Optional Remote Sensor S2 S2 Optional Remote Sensor Most existing thermostats have three parts: • The cover, which may snap or hinge over the existing thermostat. • The electronics or body, which controls the existing system. • The sub-base, where the wires attach through the wall to the existing system. 1. Always turn off power to the air conditioning and heating system prior to removing existing thermostat. 2. Carefully remove the cover and electronics body from the old thermostat sub-base. Depending on the brand, these parts may pull off or need to be unscrewed. The old sub-base should remain wired and on the wall until steps 4 and 5. 3. Label every old wire with the letter of the connection to which the wire is attached. Example letters are R, M, Y, etc. Depending on the brand of the old thermostat, your letters may be different. (continued on page 2) Front when folded • Compatibility: Compatible with low voltage single stage or multi-stage Heat / Cool systems, including heat pumps with up to three stages of heating and two stages of cooling, or conventional systems with up to two stages of heating and two stages of cooling. This thermostat can also be used on 250 to 750 millivolt heating only systems. • Terminations: A, G, Rc, Rh, W2, B, O, Y1, Y2, W1/E/W3, C, L, S1, S2

Braeburn 5300 Operation & user’s manual [PDF] (14 pages)

  • Identifier: id-665659
  • Brand: Braeburn
  • Device: 5300 Thermostat
  • Type: PDF
  • Key Aspects: Additional Modules and Accessories Guide, Hardware Setup Instructions, Troubleshooting Information
  • UPD Date: 21.07.2026
  • Source File: 661760.pdf
  • Pages: 14
  • Description: Comprehensive operating guide for the Braeburn 5300.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
CONTENTS 1 2 QUICK REFERENCE PROGRAMMING USER SETTINGS QUICK REFERENCE 1 3 4 ADDITIONAL OPERATION FEATURES TROUBLESHOOTING SYSTEM Button: Selects AUTO (Heat/Cool), COOL, OFF, HEAT or EMER. PROG Button: Program setup mode, selects setpoint time, temperature and fan setting for each program. HOLD Button: Enables extended hold, clears extended hold or temporary override. RETURN Button: Used to enter user settings and returns thermostat to normal mode from program mode. DAY/TIME Button: Selects hour, minute and day setting. Selects program day in Program setting mode. FAN Button: Selects AUTO, ON, CIRC (recirculate) and PROG (program) modes. RESET Button: Located on front of thermostat, will return programming, clock, differential settings, filter check monitor, adjustment limit from setpoint, keypad lock, temperature hold, short cycle timer and recirculating fan to default settings if previously programmed. Button: Turns on backlight for 10 seconds. Button: Increases setting (time, temperature, etc.). Scrolls between option settings. Button: Decreases setting (time, temperature, etc.). Scrolls between option settings. 1 1 2 3 4 5 6 7 8 9 10 Inside of model 5300 shown 8 9 7 1 6 2 3 4 5 10 MODEL 5300 © 2006 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5300-110-002 Premier Series Universal Auto Changeover Thermostat Up to 2 Heat / 2 Cool Conventional and Heat Pump USER MANUAL READ ALL INSTRUCTIONS BEFORE PROCEEDING Braeburn Systems LLC, as an Energy Star partner has determined that this product meets the Energy Star Guidelines developed by the U.S. Environmental Protection Agency & the U.S. Department of Energy for maximum energy efficiency. For more information on energy savings, go to www.energystar.gov

Braeburn 5300 Operation & user’s manual [PDF] (15 pages)

  • Identifier: id-2208936
  • Brand: Braeburn
  • Device: 5300 Thermostats
  • Type: PDF
  • Key Aspects: System Limitations and Considerations, System Connectivity and Wiring Basics, Troubleshooting Information
  • UPD Date: 09.04.2026
  • Source File: 2078696.pdf
  • Pages: 15
  • Description: User setup guide for the Braeburn 5300.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
MODEL5300 Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Heat Pump or 2 Heat / 2 Cool Conventional Thermostat USER MANUAL READ ALL INSTRUCTIONS BEFORE PROCEEDING Braeburn Systems LLC, as an Energy Star partner has determined that this product meets the Energy Star Guidelines developed by the U.S. Environmental Protection Agency & the U.S. Department of Energy for maximum energy efficiency. CONTENTS 1 2 QUICK REFERENCE PROGRAMMING USER SETTINGS QUICK REFERENCE 1 3 4 ADDITIONAL OPERATION FEATURES TROUBLESHOOTING SYSTEM Button: Selects AUTO (Heat/Cool), COOL, OFF, HEAT or EMER. PROG Button: Press to enter the program setup mode where you can select the time, temperature and fan setting for each program period. Scrolls backward between user/installer setup screens. HOLD Button: Enables or disables extended hold mode or temporary program override. RETURN Button: Press and hold for 4 seconds to enter the user settings mode (see user manual). Scrolls between user/ installer setup screens. Returns unit to normal mode when in program mode. DAY/TIME Button: Enters time and day setting mode. Selects individual days in program mode. FAN Button: Selects AUTO, ON, CIRC (recirculate) and PROG (program) modes. RESET Button: Resets time, program and some user settings back to the factory default. See section 4 for a list of functions that will return to their factory default settings after the RESET button is pressed. Button: Turns on backlight for 10 seconds. Button: Increases setting (time, temperature, etc.). Scrolls between option settings. Button: Decreases setting (time, temperature, etc.). Scrolls between option settings. 1 1 2 3 4 5 6 7 9 10 model 5300 shown with cover open 8 9 7 1 6 2 3 4 5 10 8 2 + 3 Press and hold both buttons at the same time to view the outdoor temperature if an outdoor sensor is connected.

Braeburn 5300 Operation & user’s manual [PDF] (15 pages)

  • Identifier: id-665658
  • Brand: Braeburn
  • Device: 5300 Thermostat
  • Type: PDF
  • Key Aspects: System Limitations and Considerations, Operational Mode Explanations, Hardware Setup Instructions
  • UPD Date: 09.07.2026
  • Source File: 661759.pdf
  • Pages: 15
  • Description: Manual for installation and usage of the Braeburn 5300.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
CONTENTS 1 2 QUICK REFERENCE PROGRAMMING USER SETTINGS QUICK REFERENCE 1 3 4 ADDITIONAL OPERATION FEATURES TROUBLESHOOTING SYSTEM Button: Selects AUTO (Heat/Cool), COOL, OFF, HEAT or EMER. PROG Button: Program setup mode; selects set point time, temperature and fan setting for each program. HOLD Button: Enables extended hold; clears extended hold or temporary override. RETURN Button: Allows user to enter settings and returns thermostat to normal mode from program mode. DAY/TIME Button: Selects hour, minute and day setting. Selects program day in Program setting mode. FAN Button: Selects AUTO, ON, CIRC (recirculate) and PROG (program) modes. RESET Button: Located on front of thermostat, will return programming, clock, differential settings, filter check monitor, adjustment limit from set point, keypad lock, temperature hold, short cycle timer and recirculating fan to default settings. Button: Turns on backlight for 10 seconds. Button: Increases setting (time, temperature, etc.). Scrolls between option settings. Button: Decreases setting (time, temperature, etc.). Scrolls between option settings. 1 1 2 3 4 5 6 7 9 10 model 5400 shown with cover ope 8 9 7 1 6 2 3 4 5 10 MODEL 5400 © 2008 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5400-110-001 Premier Series Universal Auto Changeover Thermostat Up to 3 Heat / 2 Cool Conventional and Heat Pump USER MANUAL READ ALL INSTRUCTIONS BEFORE PROCEEDING Braeburn Systems LLC, as an Energy Star partner has determined that this product meets the Energy Star Guidelines developed by the U.S. Environmental Protection Agency & the U.S. Department of Energy for maximum energy efficiency. For more information on energy savings, go to www.energystar.gov 8 2 5 2 3 + + When pressed at the same time, reviews humidity settings. When pressed at the same time, displays outdoor temperature if outdoor sensor is installed.