Up to 3 Heat / 2 Cool Heat Pump or 2 Heat / 2 Cool Conventional Thermostat USER MANUAL READ ALL INSTRUCTIONS BEFORE PROCEEDING Braeburn Systems LLC, as an Energy Star partner has determined that this product meets the Energy Star Guidelines developed by the U.S. Environmental Protection Agency & the U.S. Department of Energy for maximum energy efficiency. CONTENTS 1 2 QUICK REFERENCE PROGRAMMING USER SETT ...
NOTE: It is important for you to correctly set the current time of day (note AM/PM indicator in display), and the current day of week to avoid problems with program execution. 1. When in normal operating mode, press the DAY/TIME keypad button. The LCD display will be cleared except for the time, am/pm indicator, day of week indicator and SET. The hour portion of the time will fla ...
2.4.1 Setting the First, Second and Third Stage Differentials First Stage Differential The default setting is 0.2˚ F (0.1˚ C). The room temperature must change 0.2˚ F (0.1˚ C) from the set point temperature before the thermostat will initiate the system in heating or cooling. 1. In normal mode, press and hold the RETURN button for four seconds. The LCD display will show “d1 SET X” where “X” equals the ˚F / � ...
6 2 PROGRAMMING USER SETTINGS cont. 2.4.5 Setting the Extended Hold (Vacation) Mode (continued - see section 3.6) NOTE: Extended Hold Mode is not available if the thermostat is in the non-programmable mode. 13. In normal operating mode, press and hold the RETURN button for four seconds. Press RETURN button repeatedly until “SET LonG HOLD” is displayed, where “LonG” is indefinite hold. 14. Press the or ...
2.5 Setting Your Energy Saving Programs (continued) 2 PROGRAMMING USER SETTINGS cont. 2.5 Setting Your Energy Saving Programs – Tips Before Starting (continued) • This thermostat is preprogrammed with 4 events per day, with times and temperatures recommended by the Environmental Protection Agency and the U.S. Department of Energy in their ENERGY STAR® program. These settings provide efficient energy savings duri ...
Individual Days – allows you to program each day of the week individually to give you the greatest schedule flexibility. Often used to fine tune programming after initial programming. IMPORTANT NOTE! When in Whole Week programming, the thermostat will check if all of the days of that group have the same program set point times and temperatures. If so, the set point time and temperature ...
12 Programming Instructions–7 DAY, Residential Mode (continued) 2. If you wish to program each day individually, press the DAY/TIME button to select each day. 3. Press the or button to change the time to the desired hour in one hour increments. Press the PROG button. The minute portion of the set point time will begin flashing. 4. Press the or button to change the time to the desired minute in 10-minut ...
The 5-2 Day mode has separate Weekday and Weekend Program Groups that allow you to change the daily set point times and temperatures to meet your individual schedule needs. Weekday – allows you to program all the weekdays (M, TU, W, TH, F will show in display) at the same time. Allows programming times and temperature settings for four set points (MORN, DAY, EVE and NIGHT) to meet your weekday schedul ...
5. By selecting the opposite system mode (HEAT or COOL) with the system button you can review or change the set temperature for that mode. NOTE: If Auto Changeover is enabled in the Installer Options, and a setting is made in either heating or cooling which violates the dead band, the opposite mode will adjust up or down automat ...
3.6 Extended Hold (Vacation) Mode 1. Press the HOLD button to bypass the program schedule. The current set point temperature will be held until the HOLD condition is released. HOLD will show in the display. 2. Press the HOLD button again to return the thermostat to normal program operation. 3. The hold period lasts until the hold is released as in step number 2 above, or is limited to 24 hours if the default was ...
3.12 Recirculating Fan Feature (see section 2.4.9) The Recirculating Fan Mode provides more even temperature distribution and improves indoor air quality by circulating air through the furnace filtration system more often. The thermostat is put into the Recirculating Fan Mode by pressing the FAN button until the CIRC icon is displayed. If no call for heating or cooling occurs within the fan off cycle set in sectio ...
3 ADDITIONAL OPERATION FEATURES cont. 3.17 Low Battery Detection and Replacement This thermostat requires two (2) properly installed “AA” Alkaline batteries to maintain the system clock and to provide power for the thermostat if 24 volt AC power is not connected to the terminal block. This thermostat is equipped with a low battery detection feature that constantly monitors the batteries during normal operati ...
Potential Solution: The Residual Cooling Fan Control Feature can allow up to a 90 second fan delay after cooling system shutdown for energy efficiency gains. The default setting is 60 seconds. This can be changed to disable this feature or shorten the time period if desired (see section 4 of the Installer Guide). Symptom: Thermostat does not turn on h ...
Potential Solutions: The temperature sensed by the thermostat is higher than the 99˚ F (37˚ C) upper limit of the thermostat’s display range. The display will return to normal after the sensed temperature lowers within the 40˚ to 99˚ F (5˚ to 37˚ C) display range. Turn on the cooling system or use ...
Made in China • 5300-110-005 Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are due to faulty material or workmanship for a period of five years after the original date of purchase by a professional service technician. This warranty and our liab ...