CharlesWater 99090 Manuals

2 pdf manual(s) CharlesWater 99090 for free download (Document Types: Installation, operation and maintenance manual, Operation and maintenance)

CharlesWater 99090 Installation, operation and maintenance manual Thumbnail

CharlesWater 99090 Installation, operation and maintenance manual [PDF] (2 pages)

  • Identifier: id-1532214
  • Brand: CharlesWater
  • Device: CharlesWater 99090 Test Equipment
  • Type: Installation, operation and maintenance manual, PDF
  • Key Aspects: Critical Operational Precautions, Safety Recommendations and Warnings, Initial Startup Checklist
  • UPD Date: 25.05.2026
  • Source File: 1469065.pdf
  • Pages: 2
  • Description: Owner’s guide for the CharlesWater 99090.
Pages Preview:
  • CharlesWater 99090 Installation, operation and maintenance manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
PPE-5034.E Page 1 of 2 © 2015 Charleswater Unit 17. Millbrook Business Park, Sybron Way • Crowborough, East Sussex TN6 3JZ United Kingdom Phone: 00 44 (0) 1892-665313 • Internet: Charleswater.co.uk Made in the United States of America Calibration Unit for Testers Installation, Operation and Maintenance Description The Charleswater 99090 Calibration Unit is designed to verify whether a tester is operating within specifications. The 99090 Calibration Unit is a passive device and requires no power source. The Calibration Unit is manufactured with industry accepted test ranges for both wrist straps and foot grounders. Both the wrist strap and footwear pass range is set at 750K - 35M. The Charleswater Calibration Unit is calibrated to NIST traceable standards. The Charleswater 99090 Calibration Unit is to be used with the following items: Item Description 99037 Combo Tester 99038 Combo Tester with Stand and Foot Plate Packaging 1 Calibration Unit 2 Test Leads with Banana Plug Terminals 1 Certificate of Calibration August 2015 Figure 1. Charleswater 99090 Calibration Unit Operation COMBO TESTER Testing the Wrist Strap Circuit 1. Plug one of the included test leads into the black banana jack labeled “E” on the Calibration Unit. Connect the opposite end of the test lead into the yellow banana jack labeled “WRIST STRAP” on the Combo Tester. Toggle the switch to the “WRIST STRAP” position. TECHNICAL BULLETIN PPE-5034.E Figure 2. Connecting the test lead from banana jack “E” on the Calibration Unit to the WRIST STRAP banana jack on the Combo Tester 2. Connect the second test lead to the red 675K banana jack labeled “A” on the Calibration Unit. Touch the opposite end of the test lead to test plate on the Combo Tester and press down to activate the test. Be sure not to touch the banana plug or test plate with your skin. 3. Observe the response from the Combo Tester. The alarm should sound, and the LOW LED should illuminate red. 4. Repeat the procedure for test points B (825K), C (35M) and D (40M). The expected test results can be found in the following table. Test Point Resistance Value Test Output A 675K FAIL LOW B 825K PASS C 35M PASS D 40M FAIL HIGH
CharlesWater 99090 Operation and maintenance Thumbnail

CharlesWater 99090 Operation and maintenance [PDF] (2 pages)

  • Identifier: id-1894657
  • Brand: CharlesWater
  • Device: CharlesWater 99090 Test Equipment
  • Type: Operation and maintenance, PDF
  • Key Aspects: User Training Recommendations, Recommended Spare Parts List, System Architecture and Design Overview
  • UPD Date: 06.07.2026
  • Source File: 1828105.pdf
  • Pages: 2
  • Description: User operation guide for the CharlesWater 99090.
Pages Preview:
  • CharlesWater 99090 Operation and maintenance preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Unit 17. Millbrook Business Park, Sybron Way • Crowborough, East Sussex TN6 3JZ United Kingdom Phone: 00 44 (0) 1892-665313, Fax: 00 44 (0) 1892-668838 • E-mail: [email protected], Internet: Charleswater.co.uk PPE-5034.E November 2009 Page 1 of 2 Figure 1. Charleswater 99090 Tester Calibration Unit Description The Charleswater 99090 Tester Calibration Unit is designed to simplify the process of calibrating the Charleswater 99000 and 99004 Combo Wrist Strap / Footwear Tester. The calibration unit allows the user to quickly and easily verify whether the tester is operating within specifications. The Calibration Unit is a passive device, and requires no power source. It is manufactured with industry accepted test ranges for both wrist straps and foot grounders. The wrist strap pass range is set at 825k- 35M, and the foot ground test range is set at 825k - 35M. The Calibration Unit is supplied calibrated to NIST traceable standards. Packaging 1 Tester Calibration Unit 2 Test Leads 1 Certificate of Calibration Operation WRIST STRAP TEST CIRCUIT Step 1: Connect one of the test leads to common point banana jack “E” on the Calibration Unit. Connect the opposite end of test lead to the banana jack labeled “WRIST CORD” located on the face of the Combo Wrist Strap / Footwear Tester. Ensure that the rocker switch on the tester is set to WRIST CORD. Step 2: Connect the second test lead to the 675k jack labeled “A” on Calibration Unit. Touch the opposite end of test lead to tester’s test plate and press down with enough pressure to activate the test circuit. Observe the LED’s for the proper response as indicated below. Be sure to hold the cord at an insulated point, so that the resistance value is not affected by the body. Resistance Value Test Output - LED Red jack “A” - 675k: Red (FAIL LO) Green jack “B” - 825k: Green (PASS) Green jack “C” - 35M: Green (PASS) Yellow jack “D” - 40M: Red (FAIL HI) Step 3: Repeat the procedure testing across jacks B, C, and D on the Calibration Unit. The different resistance ranges should give the display shown above. If the tester does not meet calibration specifications, contact Charleswater for calibration. Tester Calibration Unit Operation and Maintenance TECHNICAL BULLETIN © 2009 CHARLESWATER LTD. Ensure that the rocker switch on the tester is set to FOOTPLATE. Step 2: Connect the second test lead to the 675k jack labeled “A” on Calibration Unit. Touch the opposite end of test lead to tester’s test plate and press down with enough pressure to activate the test circuit. Observe the LED’s for the proper response as indicated below. Be sure to hold the cord at an insulated point, so that the resistance value is not affected by the body. Resistance Value Test Output - LED Red jack “A” - 675k: Red (FAIL LO) Green jack “B” - 825k: Green (PASS) Green jack “C” - 35M: Green (PASS) Yellow jack “D” - 40M: Red (FAIL HI) Step 3: Repeat the procedure testing across jacks B, C, and D on the Calibration Unit. The different resistance ranges should give the display shown above. If the tester does not meet calibration specifications, contact Charleswater for calibration. Made in America Figure 2. Testing the Combo Tester’s Wrist Strap Circuit FOOTWEAR TEST CIRCUIT Step 1: Connect one of the test leads to common point banana jack “E” on the Calibration Unit. Connect the opposite end of test lead to the banana jack labeled “FOOTPLATE” located on the side of the Combo Wrist Strap / Footwear Tester. Figure 3. Testing the Combo Tester’s Footwear Circuit

Similar Manuals in the Test Equipment Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
JONARD TOOLS TBS-100

TBS-100 Instruction manual - 648TZV

2 704 141 12-07-2026 view all manuals
CPS BlackMAX TR700C Series

Manual: CPS BlackMAX TR700C Series (9QJVPV, Upd.29-03-2026)

8 301 70 29-03-2026 view all manuals
3M SE-400 Series

3M Measuring Instruments Getting started (File: PDF, 30-06-2026)

2 150 24 30-06-2026 view all manuals
Seaward Clare B255

Clare B255 Operating manual - P39HPS

38 1378 290 19-08-2026 view all manuals
Digital Watchdog SiteWatch DW-DTWT

Digital Watchdog Test Equipment Quick start manual (File: PDF, 30-04-2026)

2 1483 342 30-04-2026 view all manuals
GMW TG uni 1

PDF Guide (@G6KNM3), GMW TG uni 1 Test Equipment (11-07-2026)

44 240 46 11-07-2026 view all manuals