Contour Next Link 2.4 Manuals
2 pdf manual(s) Contour Next Link 2.4 for free download (Document Types: Quick reference manual, Operation & user’s manual)
Contour Next Link 2.4 Quick reference manual [PDF] (2 pages)
- Identifier: id-851718
- Brand: Contour
- Device: Next Link 2.4 Blood Glucose Meter
- Type: PDF
- Key Aspects: Critical Operational Precautions, Package Contents and Accessories List, Component Longevity Optimization
- UPD Date: 25.05.2026
- Source File: 892858.pdf
- Pages: 2
- Description: Technical guide for the Contour Next Link 2.4.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
® Use the arrow buttons to scroll to Continue. Press the Select button . CONNECT TO PUMP ? OK Go Back Select “Connect Device” on your Pump. CONNECT TO PUMP CONNECT TO PUMP Cancel Searching... Turn the page over to complete setup. ¬ QUICK REFERENCE GUIDE 120 mg dL Before Meal Before Meal 12:24 PM l 10/13 Bolus Bolus Reminder Reminder Notes Notes Uses only CONTOUR®NEXT Blood Glucose Test Strips ? OK Skip Connect to a MiniMed Pump? CONNECT TO PUMP New Device See User Guide to connect new device. Select Search below when ready. Search * Wall charger may not be included in all meter kits. Contact Customer Service for information on obtaining a wall charger. 120 mg/dL BG 12:24 PM Active Insulin 0.0 u MiniMed® 670G is shown Initial Setup of Meter and Connection to MiniMed® Insulin Pump 1 Remove the USB cap to reveal the USB connector. Charging Meter 2 To begin setup, hold down the top Menu button for several seconds until the meter turns on. Unplug Meter From Charging Source Before Beginning Setup Connect to Pump 3 Scroll down to select your language. Press OK. 5 Connect to a MiniMed Pump? Press OK. 6 Press OK. Put the meter down and pick up your pump. 7a Press any button to turn the screen on. Press the Menu button . If your pump does not have a Menu button go to step 7b. 7b Press the Select button . Use the Down arrow button to scroll to Options. Press Select button . 8 Press the Down arrow button to scroll to Utilities. Press Select button . Utilities Self Test Carb Unit Manage Settings Sensor Demo Device Options 9 In the Device Options menu, scroll to Connect Device. Press the Select button . Device Options Manage Devices Connect Device 10 Place the meter and pump next to each other. Select Auto Connect on your pump. 11 Read the pump screen, using the down arrow to scroll to the next page. 12 Place the meter and pump next to each other. Select Search on the pump. Search Cancel CONNECT TO PUMP Select “Search” on your Pump and meter. The search may take up to 2 minutes. 13 Check to see if Device SN (serial number) on the pump matches the Device SN on the meter. If they match, scroll to Confirm on the pump. Press the Select button . CONNECT TO PUMP CONNECT TO PUMP Use Pump to confirm Device SN: BGJ133333F Confirm Device SN GTJ133333F found SN: BGJ133333F Confirm Cancel 14 Turn the pump over. Make sure that the SN on the back of the pump matches the pump serial number now on the meter screen. Press Next. ? Next Delete MiniMed Pump connected: AA1234567B 15 Select Always and press OK on next screen. Always Ask Me Never Automatically send results to the Pump? SEND OPTIONS SEND OPTIONS 16 Select the Date Format. Month/Day/Year Day.Month.Year SELECT DATE FORMAT ? 17 Press OK. Note: If time and date are incorrect, you must change them on the pump. OK OK Date / Time is set by Pump. DATE / TIME ? 18 Press Accept to select AutoLog is Off. AutoLog allows you to mark a test result as Fasting, Before Meal, or After Meal. See your user guide to learn more. Accept Turn On AutoLog is Off. AUTOLOG AUTOLOG ? Wireless Blood Glucose Monitoring System Connect Device Manual Connect Auto Connect ? Manual Connect Auto Connect CONNECT TO PUMP CONNECT TO PUMP 4 Press OK if the correct language is displayed. Press NO if the incorrect language is displayed. If pump screen goes blank, press any button to turn it back on. When the pump links to the meter, the SN on the meter screen will change to a different serial number. This number is the pump SN. PUMP CONNECTED PUMP CONNECTED Select Auto Connect on your meter. Select Search on the meter. 10:30 AM | 10/13/11 are in search mode. Auto Connect Before using Auto Connect, be sure no other nearby MiniMed devices Cancel Continue English Deutsch Español LANGUAGE OK OK For the MiniMed 630G For the MiniMed 670G OR In the Utilities menu, use the down arrow to scroll to Device Options. Press the Select button . 85696475 Rev. 03/17 Enter BG Basal Audio Options Status Suspend Delivery Options Menu Insulin Settings Sensor Settings Event Markers Reminders Utilities BG Active Insulin Bolus Basal 1.5 u mg/dL 12:24 PM BG Active Insulin 0.0 u mg/dL 12:07 AM USB Connector Selection/Scrolling Buttons Test Strip Port Display Screen Test Strip Port Light Top Menu Button Protective USB Cap MiniMed® 670G MiniMed® 630G Meter p, e ton the n. From Charging Beginning Se Setu tup NOTE: Check the units of measure of your meter. See your meter user guide for complete instructions. The CONTOUR®NEXT LINK 2.4 meter has a permanent rechargeable battery. Charge your meter with the wall charger* or by plugging the USB connector into a computer. Be sure the computer is turned on. Your meter will briefly display “Do Not Test– Charging” and the test strip port light will flash. You cannot do a blood glucose test while the battery is charging. When charging is finished, the test strip port light will turn off. Unplug your CONTOUR NEXT LINK 2.4 meter to test. Graph Display Screen Menu Select Right Right Up Back Back Left Down Notification Light
Contour Next Link 2.4 Operation & user’s manual [PDF] (39 pages)
- Identifier: id-1206116
- Brand: Contour
- Device: Next Link 2.4 Blood Glucose Meter
- Type: PDF
- Key Aspects: Performance Optimization Tips, Pre-Deployment Preparation Steps, Critical Operational Precautions
- UPD Date: 26.04.2026
- Source File: 952162.pdf
- Pages: 39
- Description: Comprehensive user handbook for the Contour Next Link 2.4.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Active Insulin 1.5 u Bolus Basal 5.2mmol/L BG 12:00 PM ® 5.2 mmol L Before Meal 12:00 PM l 10/13 Bolus Reminder Notes ® USER GUIDE Uses only CONTOUR®NEXT blood glucose test strips Wireless Blood Glucose Monitoring System 81552940_CntrNextLINK2_4_UG_EN_FpBp_v6.indd ofc1 9/16/16 1:00 PM