Cooper Wheelock NS-24MCC Manuals
1 pdf manual(s) Cooper Wheelock NS-24MCC for free download (Document Types: Installation instructions)
Cooper Wheelock NS-24MCC Installation instructions [PDF] (4 pages)
- Identifier: id-18031
- Brand: Cooper Wheelock
- Device: NS-24MCC Smoke Alarm
- Type: PDF
- Key Aspects: Control Panel and Interface Navigation, Hardware Verification Checklists, Product Performance Metrics
- UPD Date: 01.08.2026
- Source File: 113513.pdf
- Pages: 4
- Description: Complete usage guide for the Cooper Wheelock NS-24MCC.
Click to expand and read text
273 Branchport Avenue Long Branch, NJ 07740 Thank you for using our products. (800) 631-2148 (US) INSTALLATION INSTRUCTIONS www.cooperwheelock.com SERIES NS-24MCC/MCCH MULTI-CANDELA HORN/STROBE (CEILING MOUNT VERSION) Use this product according to this instruction manual. Please keep this instruction manual for future reference. GENERAL: Cooper Wheelock’s Series NS Multi-Candela ceiling mount Horn/Strobe (NS) requires only 2-wires for operation of the horn and strobe circuits and provides either four or two selectable candela settings (15, 30, 75, 95 or 115, 117). The NS is the ideal choice for applications where the audible silence feature is required. The NS is UL Listed under Standard 1971 for Signaling Devices for the Hearing Impaired and UL Standard 464 for Audible Signal Appliances for indoor use only. It is molded with a mounting plate for use with a 4” backbox or 100mm European backbox (See Figure A and mounting procedures). This strobe model is Listed for ceiling mounting only. The NS uses a xenon flashtube with solid state circuitry enclosed in a polycarbonate lens to provide maximum visibility and reliability for effective visible signaling. The horn portion of the NS can be field set to provide either Continuous Horn or Code 3 Horn and can be field set for High (HI) or Low (LO) dBA. NOTE: The Code 3 temporal pattern (1/2 second on, 1/2 second off, 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 off and repeat) is specified by ANSI and NFPA 72 for standard emergency evacuation signaling. The Code 3 Horn should be used only for fire evacuation signaling and not for any other purpose. The NS Horn/Strobe can be used with a Sync Module (SM), Dual Sync Module (DSM) or Wheelock power supplies to provide synchronized strobe and synchronized Code 3 signal. The NS Horn/Strobe is designed for use with either filtered DC (VDC) or unfiltered full-wave-rectified (VRMS) input voltage. All inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by a fire alarm control panel (FACP). WARNING: PLEASE READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, CANDELA SETTING, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. SPECIFICATIONS: Table 1: UL Listed Models and Ratings Model Regulated Voltage (VDC/VRMS) Voltage Range Limit Per UL 464 and UL 1971 (VDC/VRMS) Strobe Candela (cd) NS-24MCC 24 16.0-33.0 15/30/75/95 NS-24MCCH 24 16.0-33.0 115/177 Table 2: dBA Sound Output for 24VDC Per UL Description Volume Reverberant dBA Per UL 464 16.0VDC 24.0VDC 33.0VDC Low 78 81 84 Continuous Horn High 84 88 90 Low 73 77 79 Code 3 Horn High 80 83 85 NOTES: 1. The strobe will produce 1 flash per second over the "Regulated Voltage" range. 2. This horn/strobe model meets the required light distribution patterns defined in UL 1971. 3. All models are UL Listed for indoor ceiling use with a temperature range of +32°F to +120°F (0°C to +49°C) and maximum humidity of 93% ± 2% RH. The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance when it is stored in the original cartons and not subjected to misuse or abuse. WARNING: CANDELA SETTING WILL DETERMINE THE CURRENT DRAW OF THE PRODUCT. Table 3: UL Current Ratings (AMPS) Maximum RMS Current with Hi dBA Setting Regulated Voltage 15cd 30cd 75cd 95cd 115cd 177cd DC 16.0-33.0VDC 0.082 0.124 0.209 0.275 0.350 0.477 FWR 16.0-33.0VRMS 0.141 0.204 0.312 0.411 0.491 0.681 Maximum RMS Current with Low dBA Setting Regulated Voltage 15cd 30cd 75cd 95cd 115cd 177cd DC 16.0-33.0VDC 0.071 0.114 0.201 0.261 0.306 0.429 FWR 16.0-33.0VRMS 0.124 0.184 0.301 0.397 0.469 0.659 When calculating the total current: Use Table 3 to determine the highest value of “RMS Current” for an individual NS then multiply the value by the total number of NS Appliances. Be sure to add the currents for any other appliances powered by the same source and to include any required safety factors. NOTE: The maximum number of strobes on a single notification appliance circuit shall not exceed 50. CAUTION: These notification appliances are UL Listed as “Regulated”. They are intended to be used with FACPs whose notification circuits are UL Listed as “Regulated.” These appliances shall not be used on UL Listed “Special Application” notification circuits unless the appliances are identified to be compatible in the installation instructions of the FACP or unless the FACP is identified to be compatible in this instruction manual. Copyright 2006 Cooper Wheelock, Inc. All rights reserved. P84794 F Sheet 1 of 4
NS-24MCC: Related Instructions
273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.cooperwheelock.com Professional user manual for the Cooper Wheelock STH-2R24MCCH(X) Speakers. This documentation highlights features and device safety checks, operational procedures, firmware updates, performance optimization.
273 Branchport Ave. Long Branch, N.J. 07740 (800) 631-2148 www.coopernotification.com 1 P85758B Copyright 2020 Cooper Wheelock Inc., dba Cooper Notification. Al Product operation manual for the Cooper Wheelock ELUXA ELSP Series Speakers. It covers installation guides, technical specifications, regulatory notices.
Features • Approvals include: UL Standard 1480 – (Speakers for Fire Protective Signaling Systems), California State Fire Marshal (CSFM) Title 19 • Meets Quick reference guide for the Cooper Wheelock STH-15S Speakers. This documentation provides step-by-step guidance on performance details, configuration options, wiring diagrams, connectivity options.
Series SA-S70-24MCW-FR Series SA-S90-24MCC-FR Series SA-S70-R Features: • Approvals Include: UL Standard 1480 (Speakers) and UL Standard 1971 and UL Standard User support manual for the Cooper Wheelock Series SA-S70-24MCW-FR Smoke Alarm. The manual provides information on operational safety, usage recommendations, diagnostic information, detailing setup.
(800) 631-2148 • www.cooperwheelock.com Series ST 6-8 06/06 4”, surface mount Order Code ST-B4 White 4116 8”, fl ush mount ST-C8 White 4114 ST-C8M ( Device maintenance guide for the Cooper Wheelock ST-B4 Speakers. The guide outlines procedures for operational procedures, daily usage, service instructions, service procedures.
Description: These listed strobes have been designed for use in potentially explosive atmospheres and harsh environmental conditions. The enclosures are suitabl Complete technical documentation for the Cooper Wheelock XB15 Smoke Alarm. The documentation guides users through setup and operating instructions, technical guidelines, user settings, hardware components.
Similar Manuals in the Smoke Alarm Category
WS4916 Series Wireless Smoke Detector Installation and Operating Instructions Read this instruction sheet thoroughly before installation and use of the WS4916 W Official user handbook for the DSC WS4916 Series Smoke Alarm. It explains configuration options and wiring diagrams, performance optimization, operational guidelines, software updates.
Detailed operating instructions for the LifeCall 7000 Smoke Alarm. This manual outlines maintenance schedule, internal layout, reset instructions.
Quick reference guide for the Code one G Smoke Alarm. It details device setup and daily usage, troubleshooting, network configuration, performance optimization.
Manual P/N 820-1552 Rev. A 1261-7201-00 SIGNALING LISTED UL ATTENTION: Please take a few minutes to thoroughly read this user’s guide which should be saved f Complete usage guide for the Firex i4618 Series Smoke Alarm. This manual describes setup, usage, and device operation tips, safety, configuration options, safety precautions.