EMC D860 Archiver Manuals

1 pdf manual(s) EMC D860 Archiver for free download (Document Types: Installation and setup manual)

EMC D860 Archiver Installation and setup manual [PDF] (6 pages)

  • Identifier: id-1510048
  • Brand: EMC
  • Device: D860 Archiver Storage
  • Type: PDF
  • Key Aspects: Operational Mode Explanations, Common Issue Diagnostic Flows, Package Contents and Accessories List
  • UPD Date: 21.05.2026
  • Source File: 1488381.pdf
  • Pages: 6
  • Description: Installation guide for the EMC D860 Archiver.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
All plug-in modules and blank plates are part of the fire enclosure and must be removed only when a replacement can be added immediately. The system must not be run without all parts in place. 4 A controller or a shelf must be operated only from a power supply input voltage range of 100–240 VAC, 50–60 Hz. 4 Each component is intended to operate with two working power supplies installed. 4 Provide a suitable power source with electrical overload protection. 4 A safe electrical earth connection must be pro- vided to the power cord. Check the grounding of the power sources before applying power. 4 The plug on each power supply cord is used as the main disconnect device. Ensure that the socket outlets are located near the equipment and are easily accessible. 4 Permanently unplug the unit if you think it is damaged in any way and before moving it. If the unit is powered by multiple sources, discon- nect all supplied power for complete isolation. 4 The power connections must always be disconnected prior to removal or replacement of a power supply module from any of the components in the system. 4 A faulty power supply module must be replaced within 24 hours. 4 Do not lift system components by yourself. A controller weighs up to 52 lbs (23.6 kg) and an expansion shelf weighs up to 78 lbs (35.5 kg). 4 Do not lift an expansion shelf by the handles on any modules. The handles are not designed to support the weight of the populated shelf. 4 To comply with applicable safety, emission, and thermal requirements, covers must not be removed and all bays must be fitted with plug-in modules. 4 Load the rack beginning at the bottom to prevent the rack from becoming top-heavy. 4 Do not extend components on slide rails until you have loaded at least three or more similarly weighted items in the rack, or unless the rack is bolted to the floor or overhead structure to prevent tipping. Caution: If the system is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Caution: The RJ45 sockets on the motherboard/PCI cards are for Ethernet connection only and must not be connected to a telecommunications network. ESD Precautions Data Domain recommends that you fit and check a suitable antistatic wrist or ankle strap and observe all conventional ESD precautions when handling plug-in modules and components. Safety The steps for a complete installation and configuration are: 1. Install hardware 2. Define the Data Domain system information for your site 3. Perform initial system configuration 4. Configure the system for data access 5. Configure optional software 6. Perform optional additional system configuration Installation and Setup Steps 1 5 4 3 2 6 Installation and Setup Guide EMC DATA DOMAIN DD860 Archiver Storage System 1. Unpack the Data Domain system. A system consists of a DD860 Archiver controller and up to 768 TB of raw storage in optional expan- sion shelves. 4 Open the packing boxes for the controller and optional expansion shelf or shelves. 4 Remove the accessories and rack mount kits for all system components. 2. Install the appropriate rack mounting hardware for the controller and expansion shelves into a 19-inch, four-post rack. Ensure that the rack is securely anchored to prevent tipping. Load the rack or cabinet beginning at the bottom to prevent the rack from becoming top-heavy. Be sure to plan appropriate vertical space to accommodate the 2U controller and 3U for each expansion shelf. 4 See the instructions included with the slide rails. 4 The expansion shelf rails also include rack installation instructions. 3. Install the controller and expansion shelves in the rack. 4 Remove the controller and expansion shelves from the shipping boxes. 4 Remove the bezel from each component. 4 Install each component horizontally on the corresponding rails and slide into the rack in the order described in the Expansion Shelf Hardware Guide. Be sure one person is at each side of each compo- nent for proper and safe installation. 4 Secure the components in the rack; see respective hardware manual. 4. Connect expansion shelves to the controller. Connect the controller’s SAS ports to the expansion shelves based on the cabling diagrams for expansion shelf connectivity. See Figures 5 or 6. Use the Cable Management Bar and Velcro strips to support and organize all cables. 5. Connect an administrative console. Attach a serial console to the controller’s serial port; or use KVM connections to connect monitor (VGA port), keyboard and mouse. See Figure 1. 6. Enable data transfer connectivity. Repeat for each connection. 4 Ethernet connection: If using 1 Gb copper Ethernet, attach a Cat 5e or Cat 6 copper Ethernet cable to an RJ45 Ethernet network port (start with eth0a and go up) on the controller, and attach the other end to an Ethernet switch or to an Ethernet port on your server. If using 1 Gb fiber Ethernet, use multimode fiber cables with LC connectors. If using 10 Gb copper Ethernet with an SFP+ connector, use a qualified SFP+ copper cable. If using 10 Gb fiber Ethernet, use MMF-850nm cables with LC duplex connectors. See Figure 1. 7. Provide redundant power to the system. 4 Controller power: Connect power cables to both receptacles. See Figure 1. On each cable, attach the cable restraint tie. 4 Expansion shelf power: Connect power cables to both receptacles and attach the power cable retention clips. See Figure 4. 8. Turn the system on. Power on any expansion shelves before the controller. The ES30 powers on when plugged in. 4 ES20 power: Turn the power switch to on for each of the two power supplies for each ES20 shelf. See Figure 3. 4 Wait approximately 3 minutes after all expansion shelves are turned on. 4 Controller power: Push the power button. See Figure 2. 4 Attach the bezels. 9. Collect the information needed for installation. Record the information in Section 2 of this document. Install Hardware 1

D860 Archiver: Related Instructions

Connectrix B Series
EMC Connectrix B Series Hardware reference manual
14.08.2026 142 pages

EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com EMC Connectrix B Series XPath OS AP-7420B Version 7.4 HARDWARE REFE Technical operation manual for the EMC Connectrix B Series Switch. It describes operating procedures and installation, operational guidelines, specifications, setup tips.

Atmos
EMC Atmos Hardware manual
18.05.2026 38 pages

EMC CORPORATION Corporate Headquarters: Hopkinton, MA  01748‐9103 1‐508‐435‐1000 www.EMC.com EMC ATMOS Hardware Guide Revision 1.6 Operation and maintenance manual for the EMC Atmos Storage. This manual describes setup, usage, and usage examples, system setup, maintenance procedures, device safety checks.

Connectrix B Series
EMC Connectrix B Series Hardware reference manual
18.05.2026 88 pages

EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.EMC.com EMC® Connectrix® B Series AP-7600B Version 5.3 Hardware Reference Detailed user guide for the EMC Connectrix B Series Switch. It explains device overview, usage examples, shutdown procedures.

VNX5300 Block
EMC VNX5300 Block Installation manual
06.07.2026 46 pages

EMC ® VNX ™ VNX5300™ Block Installation Guide P/N 300-012-924 REV 04 Maintenance and service manual for the EMC VNX5300 Block Network Hardware. It describes step-by-step system checks, internal layout, operating modes, system configuration.

Connectrix B Series
EMC Connectrix B Series Hardware reference manual
29.03.2026 214 pages

EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.EMC.com EMC® Connectrix® B Series ED-48000B Version 5.2 Hardware Referenc User support manual for the EMC Connectrix B Series Controller. It includes troubleshooting procedures and replacement parts, diagnostic information, backup procedures.

Connectrix ED-64M
EMC Connectrix ED-64M Operation & user’s manual
22.04.2026 476 pages

EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 (800) 424-EMC2 http://www.EMC.com Connectrix ED-64M 2 Gb Fibre Channel Director USER GUIDE P/N Official installation manual for the EMC Connectrix ED-64M Switch. It includes maintenance procedures and detailing setup, device instructions, compatibility information.

Similar Manuals in the Storage Category

Z68 Pro3
ASROCK Z68 Pro3 Operation & user’s manual
07.09.2026 60 pages

1 Z68 Pro3 User Manual Version 1.0 Published April 2011 Copyright©2011 ASRock INC. All rights reserved. Product operation guide for the ASROCK Z68 Pro3 Other. This guide offers instructions on specifications, device reset instructions, device calibration, hardware components.

BARRACUDA 4FC
Seagate BARRACUDA 4FC Installation manual
05.05.2026 28 pages

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Practical operating guide for the Seagate BARRACUDA 4FC Storage. It describes operating procedures and technical guidelines, operational guidelines, service contacts, usage tips.

ADT 500GB
Apricorn ADT 500GB Operation & user’s manual
18.08.2026 40 pages

The Leader in Personal Storage User Guide Manual for installation and usage of the Apricorn ADT 500GB Storage. This reference includes network setup, service instructions, troubleshooting guides.

HTS5550
Philips HTS5550 Quick start manual
24.03.2026 8 pages

Register your product and get support at www.philips.com/welcome HTS5550 Quick Start Instruction and usage manual for the Philips HTS5550 Home Theater System. This reference manual explains safety information, repair references, service contacts, device safety checks.