Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 1 HP-2 Indirect/Direct Mitered Corner Installation Instructions © 2016 FINELITE, INC. ALL RIGHTS RESERVED. Form 98281 V2. 11/16 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S Secure To Structure (by others) Power Cords Canopy GridBox™ Starter Top Glow™ Diffuser Bottom Diffuser Starter Step 1 Remove diffusers from starter and set aside to prevent it from getting dirty or damaged. Aircraft Cable Power Cords Caddy Clip Starter GridBox™ Canopy Secure To Structure (by others) Step 2 Install GridBox™ and caddy clip onto ceiling grid, then canopies and aircraft cable assemblies. Align aircraft cables to grippers and insert on both ends of the luminaire. Adjust pendant to proper height and level. Press down on top of gripper to release locking mechanism if needed. Secure luminaire to structure using tie-wire (by others) according to code. Step 3 Install power cable through canopy and into GridBox. Make electrical connections in GridBox. Power Cords Gripper Feed Hole Starter Safety Stop Step 4 Slide safety stop and safety crimp up to the aircraft cable within 9" of cable gripper. Trim excess cable and insert safety bar assembly through feed hole. Bottom Diffuser Joiner/Ender Top Glow™ Diffuser Step 5 Remove diffusers from joiner/ender and set aside to prevent it from getting dirty or damaged. Aircraft Cable Cable Bushing Ceiling Luminaire Locate aircraft cables. Power Cords Aircraft Cable Press Here To Release Gripper Canopy Power Cords 0 - 10V Dimming Scan QR code for helpful video(s) Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 2 HP-2 Indirect/Direct Mitered Corner Installation Instructions © 2016 FINELITE, INC. ALL RIGHTS RESERVED. Form 98281 V2. 11/16 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S Caddy Clip Starter Canopy Step 6 Install caddy clip for joiner/ender. Yoke Brackets x2 (provided) Joint Sleeve #10-32 x 5/8" Screws x2 (provided) Joiner/Ender Starter Step 11 IMPORTANT STEP: Secure joint with two yoke brackets (provided) using #10-32 x 5/8" screws (provided). CAUTION: When installed correctly these brackets will pull luminaires together to make a tight joint. Do not over-tighten. Power Cords Gripper Feed Hole Joiner Safety Stop Step 7 Slide safety stop and safety crimp up to the aircraft cable within 9" of cable gripper. Trim excess cable and insert safety bar assembly through feed hole. Starter Inner Joiner Sleeve Aircraft Cable Joiner/Ender Joiner Sleeve Step 8 Align starter and joiner/ender, then slide luminaires together. Remove back plate clips (provided) to release back plates. We recommend using a flat head screwdriver to get them loose. CAUTION: Do not lose these pieces. Joiner/Ender Starter Double Diffuser (pre-installed) Step 9 Back Plate Clip Back Plate Joiner/Ender Starter Step 10 Pivot Point Slowly swing down back plates. CAUTION: Do not twist back plate when swinging down – it will come out of the support extrusion. Note that the screw shown is the pivot point and the back plate can be slid a few inches either way for ease of access to the driver space. IMPORTANT STEP Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 3 HP-2 Indirect/Direct Mitered Corner Installation Instructions © 2016 FINELITE, INC. ALL RIGHTS RESERVED. Form 98281 V2. 11/16 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S Bottom Diffuser Top Glow™ Diffuser Joiner/Ender Starter Plug-Together Wiring Joiner/Ender Starter Step 12 Step 14 Connect plug-together wiring. Reinstall diffusers and turn power on to luminaire. Replace back plates by holding them in their original position and pushing the clips back in. Make sure wire connections are not pinched. (If 1 ft. back plate assembly is near joint, reconnect feed harness to LED board). Joiner/Ender Starter Double Diffuser (pre-installed) Back Plate Clip Step 13

Document Preview & Text Transcription

Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 1 HP-2 Direct Starter/Independent Installation Instructions © 2016 FINELITE, INC. ALL RIGHTS RESERVED. Form 98234 V2. 11/16 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S GridBox™ Caddy Clip Secure to Structure (by others) Power Cord Safety Stop Gripper Feed Hole Step 1 Install grippers onto threaded studs on both ends of the luminaire. GridBox™ Aircraft Cable Power Cable Canopy Caddy Clip Secure to Structure (by others) Step 2 Install GridBox™ and caddy clip onto ceiling grid, then canopies and aircraft cable assemblies. A. Align aircraft cables to grippers and insert on both ends of the luminaire. Adjust pendant to proper height and level. Press down on top of gripper to release locking mechanism if needed. Secure luminaire to structure using tie-wire (by others) according to code. B. End plates are adjustable for custom mounting locations. Remove #8-18 x 1/4" screw (provided) from end plate, then slide end plate to desired location and reinstall #8-18 x 1/4" screw. Step 4 Slide safety stop and safety crimp up to the aircraft cable within 9" of cable gripper. Trim excess cable and insert safety bar assembly through feed hole. Turn power on to luminaire. Step 3 Install power cable through canopy and into GridBox™. Make electrical connections in GridBox. Aircraft Cable Cable Bushing Ceiling Luminaire Locate aircraft cables. Gripper Threaded Stud Power Cord Press Down Here to Release Locking Mechanism Power Cord Gripper Aircraft Cable GridBox™ Canopy Power Feed Threaded Coupler Aircraft Cable End Plate #8-18 x 1/4" Screw (provided) A B 0 - 10V Dimming Scan QR code for helpful video(s) Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 1 HP-2 Direct Joiner/Ender Installation Instructions © 2016 FINELITE, INC. ALL RIGHTS RESERVED. Form 98235 V2. 11/16 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S Aircraft Cable Gripper End Plate Joiner/Ender Diffuser Step 1 Remove diffusers and set aside to prevent it from getting dirty or damaged. Joiner/Ender Starter Caddy Clip Aircraft Cable Step 2 Install caddy clip for joiner/ender. Install canopy, cable bushing and aircraft cable onto caddy clip. Step 3 Install gripper onto end plate of luminaire then install aircraft cable into gripper. Adjust pendant to proper height and level. Joiner Plate Starter Joiner/Ender Safety Stop Step 4 Align starter and joiner/ender luminaires and slide luminaires together. Slide safety stop and safety crimp up to the aircraft cable within 9" of cable gripper. Trim excess cable and insert safety bar assembly through feed hole. Safety Stop Caddy Clip Canopy Cable Bushing Aircraft Cable Aircraft Cable Cable Bushing Ceiling Luminaire Locate aircraft cables. 0 - 10V Dimming Scan QR code for helpful video(s) Back Plates Starter Joiner/Ender Step 5 Remove back plate clips (provided) to release back plates. We recommend using a flat head screwdriver to get them loose. CAUTION: Do not lose these pieces. Back Plate Clip Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 2 HP-2 Direct Joiner/Ender Installation Instructions © 2016 FINELITE, INC. ALL RIGHTS RESERVED. Form 98235 V2. 11/16 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S Starter Joiner/Ender Yoke Brackets (provided) x 2 Joint Sleeve #10-32 x 5/8" Screws (provided) x 2 Joint Sleeve Step 7 IMPORTANT STEP: Secure joint with two yoke brackets (provided) using #10-32 x 5/8" screws (provided). CAUTION: When installed correctly these brackets will pull luminaires together to make a tight joint. Do not over-tighten. Diffuser Starter Joiner Reinstall diffusers and turn power on to luminaire. Starter Joiner/Ender Plug-Together Wiring Step 8 Connect plug-together wiring. Back Plates Starter Joiner/Ender Step 6 Pivot Point Slowly swing down back plates. CAUTION: Do not twist back plate when swinging down – it will come out of the support extrusion. Note that the screw shown is the pivot point and the back plate can be slid a few inches either way for ease of access to the driver space. Back Plates Starter Joiner/Ender Step 9 Replace back plates by holding them in their original position and pushing the clips back in. Make sure wire connections are not pinched. (If 1 ft. back plate assembly is near joint, reconnect feed harness to LED board). Back Plate Clip Step 10 IMPORTANT STEP

Document Preview & Text Transcription

Patent Pending Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 1 of 8 © 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98386. V2 11/17 HP-2 Wall Wash Arm Mount Installation Instructions CAUTION: All power connections to be installed to local/national codes by a Certified Electrician. Overview This is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary. 0-10V Dimming Helpful Videos Step 1 Mounting Locations Page 2 Stud Wall Step 4 Joining Luminaires Pages 5-6 Step 5 Luminaire Closure Page 7 Note: Starter/Independents only require 2 arm brackets up to 12-feet. Step 3 Hang Luminaire and Wire Connections Page 4 Step 2 Assemble Arm to Housing Brackets Page 3 Patent Pending Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 2 of 8 © 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98386. V2 11/17 HP-2 Wall Wash Arm Mount Installation Instructions CAUTION: All power connections to be installed to local/national codes by a Certified Electrician. Step 1 – Mounting Locations Starter/Independents only require 2 arm brackets up to 12-feet. A. Starter/Independent Mounting Locations B. Joiner/Ender Mounting Locations Endcap Endcap Point A *Luminaire length not including endcap. Luminaire* Length Junction Box Feed Location 4-1/2" 1-1/8" 1/4" 1/4" 6" 6" Wall Brackets Starter Endcap Luminaire* Length Luminaire* Length Junction Box Feed Location 4-1/2" 1-1/8" 1/4" 1/4" 3/8" 6" 6" 6" Starter Joiner/Ender Point A 6" Wall Brackets Position luminaire on wall in desired location. Mark the bottom corner of the luminaire as Point A; DO NOT include endcap. Use Point A to mark feed location and install junction box. Center of wall brackets is 6" from Point A. Make sure wall brackets have proper structurally secured backing (by others). Patent Pending Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 3 of 8 © 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98386. V2 11/17 HP-2 Wall Wash Arm Mount Installation Instructions CAUTION: All power connections to be installed to local/national codes by a Certified Electrician. Step 2 - Assemble Arm to Housing Brackets ¹ Preferred power feed location shown. ² Part by others but also available from Finelite upon request. Screws (by others) #10-32 x 5/8" Screws (by others) Perform this step for both arms on a flat surface. Slide arm attachment assembly into housing brackets. Ensure that wall bracket cover is away from the ends of the arm. Pass electrical wire through the channel of the arm assembly. Install #10-32 x 5/8" screws (provided) to secure arm attachment assembly onto housing bracket. Level wall bracket to ensure proper mounting. Install screws or fasteners (by others) appropriate for structure type through bracket and into structurally secured blocking. A. Install Wall Bracket Perspective View Housing Bracket Electrical Wire #10-32 x 5/8" Screws (4) (provided) B. Assemble Arm Side View Arm Assembly Screws (by others) Wall Bracket J-Box Wall Bracket Cover

Document Preview & Text Transcription

Patent Pending Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 1 of 13 © 2018 FINELITE, INC. ALL RIGHTS RESERVED. Form CE - 98532. 03/18 HP-2 / HP-4 / HP-6 Recessed or Regressed Spackle & Visible Flange Mitered Corner Installation Instructions Overview Step 5 Joining Luminaires Page 8 Step 1 Rough-Ins & Mounting Options Pages 2-3 Step 2 Identification & Preparation Page 4 Step 9 Closing Luminaires Pages 12-13 Step 4 Mounting Starter to Structure Pages 6-7 Step 3 Opening Luminaires Pages 5 Step 6 Securing Luminaire Joints Page 9 Step 7 Joining Mitered Corners Page 10 Step 8 Securing Corners Joints Page 11 • This installation requires proper support as each luminaire is being installed. • DO NOT attempt to join luminaires together on the floor. Damage may result when lifted. Follow these instructions. NOTE This is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary. Helpful Video 0-10V Dimming Patent Pending Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 2 of 13 © 2018 FINELITE, INC. ALL RIGHTS RESERVED. Form CE - 98532. 03/18 HP-2 / HP-4 / HP-6 Recessed or Regressed Spackle & Visible Flange Mitered Corner Installation Instructions Step 1 - Rough-Ins & Mounting Options Rough-In Widths Total Run Length W CONTINUED X1 X2 Y2 L1 L2 Rough-In Lengths Y1 Starter ID: 1 Joiner ID: 2 Ender ID: 3 Z = Mounting Hole Location (Does not include endcaps) HP-2 5" HP-4 6" HP-6 6-1/2" X = Luminaire section length (Does not include endcaps) Y1 = Total run length of luminaire (Does not include endcaps) Y2 = Total run length of luminaire (Does not include endcaps) Z = Mounting hole location Refer to Record Drawings and building plans to determine exact mounting, suspension points, and power feed locations. • Use rough-in Length & Width dimension and Record Drawings to determine rough-in measurements. • Build wall/ceiling with rough-in according to rough-in dimensions. • CRITICAL: Drywall or weak paneling must be secured to blocking (studs) around rough-in opening in the wall/ceiling. Spackle Flange (SF) W Visible Flange (VF) W * Tolerance +/- 1/16" L1 & L2 = Total Run Rough-In Length* Spackle Flange Visible Flange L1 L2 L1 L2 HP-2 Y1 + 7/16" Y2 + 7/16" Y1 + 5/16" Y2 + 5/16" HP-4 Y1 + 9/16" Y2 + 9/16" Y1 + 7/16" Y2 + 7/16" HP-6 Y1 + 7/16" Y2 + 7/16" Y1 + 5/16" Y2 + 5/16" This is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary. Z Z Z Z Endcap Endcap W = Rough-In Width* Spackle Flange Visible Flange HP-2 3-1/8" 2-7/8" HP-4 4-7/8" 4-1/4" HP-6 6-1/8" 5-7/8" * Tolerance +/- 1/16" Patent Pending Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 3 of 13 © 2018 FINELITE, INC. ALL RIGHTS RESERVED. Form CE - 98532. 03/18 HP-2 / HP-4 / HP-6 Recessed or Regressed Spackle & Visible Flange Mitered Corner Installation Instructions Step 1 - Rough-Ins & Mounting Options This is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary. 1/4"-20 Washer & 1/4"-20 Nut (by others) 1/4" Threaded Rod (by others) Drywall Ceiling/Wall Drywall Ceiling/Wall Structure Support (by others) 1/4" Lag Bolt (by others) • Luminaire mounting holes sized for 1/4"-20 threaded rod. • Refer to Record Drawings to determine mounting hole locations on luminaires and install threaded rods to structure. • Distance from threaded rod to wall/ceiling surface1 must be a minimum of 3-1/2". • Refer to Record Drawings to determine mounting hole locations on luminaires and install support blocking² to structure. • Distance from support block to wall/ceiling surface1 must be a minimum of 4-1/8". 3-1/2" min. 4-1/8" min. Support Blocking2 (by others) Support Blocking2 (by others) Mounting Options Option 1 - Mount to Threaded Rod Option 2 - Mount to Structure 1/4"-20 Washer (by others) 1/4"-20 Nut (by others) Mounting Option 1 Threaded Rod (by others) ¹ Wall/ceiling surface = drywall, wood, concrete or masonry, metal panels, tile, etc. ² Support blocking = Wooden beams/studs, sheet metal framing beams, steel beams, concrete beams, etc. Use hardware appropriate to the beam material. 1/4"-20 Lag Bolt (by others) Mounting Option 2 Patent Pending Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 4 of 13 © 2018 FINELITE, INC. ALL RIGHTS RESERVED. Form CE - 98532. 03/18 HP-2 / HP-4 / HP-6 Recessed or Regressed Spackle & Visible Flange Mitered Corner Installation Instructions HP-6 VF - 8' ABC Corporation - A12345 HP-6-VF - 32' - S - 835 - F - 120V - SC - C1 - OBO STARTER ID: 1 HP-6 VF - 16' ABC Corporation - A12345 HP-6-VF - 32' - S - 835 - F - 120V - SC - C1 - OBO JOINER ID: 2 HP-6 VF - 23' ABC Corporation - A12345 HP-6-VF - 32' - S - 835 - F - 120V - SC - C1 - OBO ENDER ID: 3 ABC Corporation - A12345 HP-6 VF - 32' - H - 835 - F - 120V - SC - C1 HP-6 VF - X' ID: 1 STARTER This is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary. A. Identify Luminaires B. Remove Diffuser Step 2 - Identification & Preparation Kitted Hardware • Identify all luminaires by their ID label that can be found on the box, the diffuser and inside the luminaire. • NOTE: Exact location of labels in these areas may vary. • Remove all luminaires from their box. • Arrange luminaires in order according to ID# at their install locations. • Refer to Record Drawings that can be found in the hardware kit. • Carefully remove all diffusers, keeping them inside their protective bags. • Set aside all diffusers to prevent from getting dirty or damaged. • Ensure diffusers can be clearly identified back to its corresponding luminaire. • CAUTION (Spackle Flange Only): Carefully remove "Mud Guards" and keep them as they will be reinstalled in Step 9, B. Yoke Bracket Part# 45042 #10-32 x 5/8" Screw Part# 94144 Securing Luminaire Joints p. 9, Step 6 Securing Corner Joints p. 11, Step 8 Diffuser Protective Bag Backplate Mud Guard (provided) ID Labels Factory Order Number Job Name Unique Luminaire ID Number Full Catalog Order ID Luminaire Section Type Luminaire Type and/or Run Length • Finelite has provided items listed here, with their Finelite part numbers. These items can be found in separate boxes shipped with the luminaire. • Account for all parts and set aside until they are needed. • All other hardware needed for this installation will be "by others".

Document Preview & Text Transcription

Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 1 HP-2 Recessed 1" T-Bar to Visible Flange Installation Instructions Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S © 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98302 V3. 01/17 2-3/4" Diffuser Corner Joiner A Step 1 Remove diffuser from corner joiner luminaire and set aside to prevent it from getting dirty or damaged. Add 1/2" to body/row length (A), +/- 1/16" to simplify installation. Luminaire needs to be installed next to support blocking. Ceiling Corner Joiner 1/4"-20 Threaded Rod Hole Wall Step 4 Make sure visible flange is flush with ceiling T-Bar. 1/4"-20 Threaded Rod Hole Feed Hole 2-1/4" 3/4" 5" Mounting Location 0 - 10V Dimming Scan QR code for helpful video(s) Step 2 Remove back plate clips (provided) to release back plates. We recommend using a flat head screwdriver to get them loose. CAUTION: Do not lose these pieces. Back Plate Clip Step 3 Slowly swing down back plates from all luminaires. CAUTION: Do not twist back plate when swinging down - it will come out of the support extrusion. Note that the screw shown is the pivot point and the back plate can be slid a few inches either way for ease of access to the driver space. Pivot Point A. Secure corner joiner by installing 1/4" washers (by others) and 1/4"-20 nuts (by others) onto 1/4"-20 threaded rod (by others). 1/4" Washer (by others) 1/4"-20 Nut (by others) 1/4"-20 Threaded Rod (by others) Step 5 1/4"-20 Threaded Rod (by others) Drywall Drywall 1/4"-20 Nut (by others) Luminaire Support Blocking (by others) Support Blocking (by others) Starter Joiner/Ender A + 1/2" +/- 1/16" Cutout Dimension 2-3/4" 4" Ceiling Joiner Diffuser Step 6 Plug-Together Wiring Ceiling Joiner Wall Corner Joiner Step 7 Remove diffuser from recessed 1" T-Bar joiner luminaire and set aside to prevent it from getting dirty or damaged. Place joiner luminaire on T-Bar. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 2 HP-2 Recessed 1" T-Bar to Visible Flange Installation Instructions Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S © 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98302 V3. 01/17 Wall T-Bar Joiner Bracket Ceiling Joiner Corner Joiner Step 8 #10-32 x 5/8" Screws (2) (provided) Corner Joiner Ceiling Joiner Yoke Brackets x2 (provided) Step 9 Align joiner bracket with corner joiner. Slide ceiling joiner towards corner joiner. IMPORTANT STEP: Secure joint with two yoke brackets (provided) using #10-32 x 5/8" screws (provided). CAUTION: When installed correctly these brackets will pull luminaires together to make a tight joint. Do not over-tighten. Plug-Together Wiring Corner Joiner Ceiling Wall Ceiling Joiner Connect plug-together wiring. Step 10 B. Alternate mounting option – Install 1/4" screw (by others) through mounting hole into proper structurally supported blocking (by others). Alternate 1/4" Screw Mounting Option ALTERNATE MOUNTING OPTION 1/4" Screws (by others) Drywall Drywall Support Blocking (by others) Support Blocking (by others) Support Blocking (by others) IMPORTANT STEP Wires Splice box door Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 3 HP-2 Recessed 1" T-Bar to Visible Flange Installation Instructions Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S © 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98302 V3. 01/17 Diffuser Diffuser Wall Ceiling Ceiling Joiner Corner Joiner Replace diffusers and turn power on to luminaires. Conduit Plate Wires Wires Conduit Plate Jam Nut Conduit Run power cables through conduit plate and jam nut. Make electrical connections. Secure conduit onto conduit plate with jam nut, and reinstall conduit plate carefully not to damage any wiring. Open optional splice box door to access wiring. Step 13 Step 14 Step 15 Wires Splice Box Door Jam Nut Conduit OPTIONAL SPLICE BOX OPTIONAL SPLICE BOX Remove conduit plate from ceiling joiner luminaire. Run power cable through knock-out. Make electrical connections. Secure conduit on to splice box with jam nut and close splice box door. T-Bar Bracket (provided) Tie-wire (by others) #8-18 x 1/4" Screws (4) (provided) #6-20 x 1/2" Self Drilling Screws (4) (provided) Wall Ceiling Ceiling Joiner Corner Joiner Back Plates Step 11 Step 12 Replace all back plates by holding them in their original position and pushing the clips back in. Make sure wire connections are not pinched. (If 1 ft. back plate assembly is near joint, reconnect feed harness to LED board. Install T-Bar brackets (provided) onto ceiling joiner with #8-18 x 1/4" screws (provided). Secure luminaire to T-Bar with #6-20 x 1/2" self drilling screw (provided). Secure luminaire to structure using tie-wire (by others), as per code. #8-18 x 1/4" Screws (4) (provided) #6-20 x 1/2" Self Drilling Screws (4) (provided) Back Plate Clip

Document Preview & Text Transcription

© 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98303 V3. 02/17 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 1 HP-2 Recessed 1" T-Bar to Spackle Flange Installation Instructions Corner Joiner Diffuser 3" A Step 1 Remove diffuser from corner joiner luminaire and set it aside to prevent it from getting dirty or damaged. Add 3/4" to body/row length (A), +/- 1/16" to simplify installation. Luminaire needs to be installed next to support blocking. Step 2 Ceiling Corner Joiner 1/4"-20 Threaded Rod Hole Wall Insert corner joiner luminaire into wall rough opening. Use proper support blocking (by others). Make sure spackle flange is flush with ceiling T-Bar. Remove back plate clips (provided) to release back plates. We recommend using a flat head screwdriver to get them loose. CAUTION: Do not lose these pieces. Step 4 Back Plate Clip Back Plate Step 3 Slowly swing down back plates from all luminaires. CAUTION: Do not twist back plate when swinging down - it will come out of the support extrusion. Note that the screw shown is the pivot point and the back plate can be slid a few inches either way for ease of access to the driver space. Pivot Point 0 - 10V Dimming Scan QR code for helpful video(s) A. Secure corner joiner by installing 1/4" washers (by others) and 1/4"-20 nuts (by others) onto 1/4"-20 threaded rod (by others). 1/4" Washer (by others) 1/4"-20 Nut (by others) ower Wires 1/4"-20 Threaded Rod (by others) Step 5 1/4"-20 Threaded Rod (by others) Drywall Drywall Drywall Screws (by others) 1/4"-20 Nut (by others) Luminaire Support Blocking (by others) Support Blocking (by others) Starter Joiner/Ender A + 3/4" +/- 1/16" Cutout Dimension 4" 3" © 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98303 V3. 02/17 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 2 HP-2 Recessed 1" T-Bar to Spackle Flange Installation Instructions #10-32 x 5/8" Screws (2) (provided) Corner Joiner Ceiling Joiner Yoke Brackets x2 (provided) IMPORTANT STEP: Secure joint with two yoke brackets (provided) using #10-32 x 5/8" screws (provided). CAUTION: When installed correctly these brackets will pull luminaires together to make a tight joint. Do not over-tighten. Wall Corner Joiner Plug-Together Wiring Ceiling Joiner Step 7 Place ceiling joiner luminaire on to T-Bar. Align ceiling joiner and corner joiner and slide them together. Plug-Together Wiring Corner Joiner Ceiling Wall Ceiling Joiner Connect plug-together wiring. Wall Ceiling Ceiling Joiner Corner Joiner Back Plates Step 10 Replace all back plates by holding them in their original position and pushing the clips back in. Make sure wire connections are not pinched. (If 1 ft. back plate assembly is near joint, reconnect feed harness to LED board. Back Plate Clip B. Alternate mounting option – Install 1/4" screw (by others) through mounting hole into proper structurally supported blocking (by others). Alternate 1/4" Screw Mounting Option ALTERNATE MOUNTING OPTION 1/4" Screws (by others) Drywall Screws (by others) Drywall Drywall Support Blocking (by others) Support Blocking (by others) Support Blocking (by others) Ceiling Joiner Diffuser Step 6 Remove diffuser from ceiling joiner luminaire and set aside to prevent it from getting dirty or damaged. Step 8 Step 9 IMPORTANT STEP © 2017 FINELITE, INC. ALL RIGHTS RESERVED. Form 98303 V3. 02/17 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 3 HP-2 Recessed 1" T-Bar to Spackle Flange Installation Instructions T-Bar Bracket (provided) Tie-wire (by others) #8-18 x 1/4" Screws (4) (provided) #6-20 x 1/2" Self Drilling Screws (4) (provided) Wall Ceiling Ceiling Joiner Corner Joiner Diffuser Diffuser Replace diffusers and turn power on to luminaires. Conduit Plate Wires Wires Conduit Plate Jam Nut Conduit Run power cables through conduit plate and jam nut. Make electrical connections. Secure conduit onto conduit plate with jam nut, and reinstall conduit plate carefully not to damage any wiring. Remove conduit plate from ceiling joiner luminaire. Step 12 Step 13 Step 15 Step 11 Install T-Bar brackets (provided) onto ceiling joiner with #8-18 x 1/4" screws (provided). Secure luminaire to T-Bar with #6-20 x 1/2" self drilling screw (provided). Secure luminaire to structure using tie-wire (by others), as per code. #8-18 x 1/4" Screws (4) (provided) #6-20 x 1/2" Self Drilling Screws (4) (provided) Wires Splice box door Wires Splice Box Door Jam Nut Conduit OPTIONAL SPLICE BOX Run power cable through knock-out. Make electrical connection. Secure conduit on to splice box with jam nut and close splice box door. Open optional splice box door to access wiring. OPTIONAL SPLICE BOX Ceiling Corner Joiner Wall Drywall screws (by others) “Mud Guard” Cardboard Inserts (provided) Trowel Step 14 Fasten corner joiner to wall with drywall screws (by others). Install “mud guard” cardboard inserts (provided). Use spackle to cover up the flanges. Once spackling is complete, remove the mud guards.

Document Preview & Text Transcription

Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 1 © 2016 FINELITE, INC. ALL RIGHTS RESERVED. Form 98240 V2. 11/16 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S HP-2 Recessed T-Bar Mitered Corner Installation Instructions Conduit Plate (provided) #8-18 x 1/4" Screws (provided) Conduit (by others) Jam Nut (by others) Wiring Connections Starter Step 2 Install starter luminaire on to T-Bar. T-Bar Bracket (provided) Starter #8-18 x 1/4" Screws (4) (provided) Tie-wire (by others) Step 3 Attach T-Bar bracket (provided) to luminaire with #8-18 x 1/4" screw (provided). Secure luminaire to structure using tie-wire (by others), as per code. Step 4 Remove conduit plate then install wiring through conduit plate and through jam nut. Secure jam nut onto conduit. Make wiring connections and then reinstall conduit plate. Diffuser Starter Step 1 Remove diffuser and set aside to prevent it from getting dirty or damaged. 0 - 10V Dimming Scan QR code for helpful video(s) Wires Splice Box Door Jam Nut Conduit Wires Splice box door Open optional splice box door to access wiring. Run power cable through knock-out. Make electrical connections. Secure conduit on to splice box with jam nut and close splice box door. OPTIONAL SPLICE BOX Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 2 © 2016 FINELITE, INC. ALL RIGHTS RESERVED. Form 98240 V2. 11/16 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S HP-2 Recessed T-Bar Mitered Corner Installation Instructions Back Plate Joiner/Ender Starter Elbow Sleeves Joiner/Ender Starter Channels Step 7 Align elbow sleeves with channels in body. Slide joiner/ender onto starter. Remove back plate clips (provided) from back plates at corner joint. Starter Joiner/Ender Step 6 Slide joiner/ender luminaire onto T-Bar. Starter Joiner/Ender Double Diffuser (pre-installed) Step 8 Step 9 Slowly swing down back plates. CAUTION: Do not twist back plate when swinging down - it will come out of the support extrusion. Note that the screw shown is the pivot point and the back plate can be slid a few inches either way for ease of access to the driver space. IMPORTANT STEP: Secure joint with two yoke brackets (provided) using #10-32 x 5/8" screws (provided). CAUTION: When installed correctly these brackets will pull luminaires together to make a tight joint. Do not over-tighten. #10-32 x 5/8" Screws (provided) Yoke Brackets (provided) Starter Joiner/Ender Step 10 Back Plate Clip Pivot Point Joiner/Ender Diffuser Step 5 Remove diffuser from joiner/ender luminaire and set aside to prevent it from getting dirty or damaged. IMPORTANT STEP Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com 3 © 2016 FINELITE, INC. ALL RIGHTS RESERVED. Form 98240 V2. 11/16 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S HP-2 Recessed T-Bar Mitered Corner Installation Instructions Diffuser Diffuser Starter T-Bar Bracket Joiner/Ender #8-18 x 1/4" Screws (4) (provided) #6-20 x 1/2" Self Drilling Screws (4) (provided) Secure To Structure (by others) Step 12 Step 13 Attach T-Bar bracket (provided) onto joiner/ender with #8-18 x 1/4" screws (provided). Secure joiner/ender to structure using tie-wire (by others), as per code. Secure all luminaires to the T-Bar by driving #6-20 x 1/2" self drilling screws (provided) through the T-Bar brackets (provided) into the T-Bar. Reinstall diffusers and turn power on to luminaires. Plug-Together Wiring Back Plate Double Diffuser (pre-installed) Starter Joiner/Ender Connect plug-together wiring. Close all back plates by pushing them back in their original position and pushing the clips back in. Step 11 Back Plate Clip

Document Preview & Text Transcription

© 2019 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98540. V3 EFFECTIVE DATE: 08/26/19 HP-2 / HP-4 / HP-6 Driver Replacement Instructions Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com This is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary. 1 of 5 Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S Overview Uplight Driver Replacement Pages 4-5 Downlight Driver Replacement Pages 2-3 0-10V Dimming Driver Replacement • All power connections should be installed according to local/national codes by a Certified Electrician. • This installation requires proper support as each luminaire is being installed. • DO NOT attempt to join luminaires together on the floor. Damage may result when lifted. NOTES HELPFUL VIDEOS Effortless Access Louver Removal 2 of 5 HP-2 / HP-4 / HP-6 Downlight Driver Replacement Instructions © 2019 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98540. V3 EFFECTIVE DATE: 08/26/19 Effortless Access Step 1 - Opening Luminaire A. Remove Diffuser or Louver Backplate Backplate Flathead Screwdriver Clip Backplate • Carefully rotate backplate out and let it hang from luminaire body. Putty Knife Option Remove Diffuser Remove Louver (HP-2 & HP-4 ONLY) Flathead Screwdriver Option Clip Backplate Putty Knife B. Release Backplate • CAUTION: Wear gloves to keep diffuser or louver surface clean. • Carefully remove diffuser or louver and set aside to prevent from getting dirty or damaged. • FOR LOUVER: Release louver by inserting the blade of a putty knife approximately 1" behind louver edges and pry down. • Ensure diffuser or louver can be clearly identified back to its corresponding luminaire. Backplate • Release backplate from clips by sliding the blade of a putty knife behind backplate edges. • To use a flathead screwdriver, press end of screwdriver (from inside the luminaire) against the clip, until the backplate is released. Louver Removal Diffuser Putty Knife Louver NOTE: For White Cross Blade Baffle, refer to Baffle Tether Addendum before installing. 3 of 5 HP-2 / HP-4 / HP-6 Downlight Driver Replacement Instructions © 2019 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98540. V3 EFFECTIVE DATE: 08/26/19 0-10V Dimming Driver Replacement NOTE: For White Cross Blade Baffle, refer to Baffle Tether Addendum before installing. A. Release Driver B. Replace Driver Step 2 - Replace Driver • Release driver from luminaire by removing mounting screws. • Disconnect driver from driver harness. • Once driver is free, disconnect electrical connections from the driver. • Replace with new driver and reconnect all electrical connections. • Replace backplate by snapping back into clips. • CAUTION: Wear gloves to keep diffuser or louver surface clean. • NOTE: For White Cross Blade Baffle, refer to Baffle Tether Addendum before installing. • Replace diffuser or louver and turn power on. Electrical Connectors Driver Harness Driver Screw Washer WIRING LEGEND Black Hot Line Voltage White Neutral Line Voltage Green Ground Grey Dimming 0-10V DC Purple Dimming 0-10V DC Driver Harness Part # 15501 4 of 5 HP-2 / HP-4 Uplight Driver Replacement Instructions © 2019 FINELITE, INC. ALL RIGHTS RESERVED. Form - 98540. V3 EFFECTIVE DATE: 08/26/19 A. Remove Diffuser • To release backplate, use a putty knife to slip behind backplate edges and release them from clips. • Lift backplate out of housing channel, pulling wiring harnesses through the housing. • Let backplate rest atop of luminaire. DO NOT disconnect LED board harnesses. Uplight Backplate Putty Knife Backplate Clip Harness B. Release Backplate Diffuser • Remove diffuser and set aside to prevent from getting dirty or damaged. Effortless Access Step 1 - Opening Luminaire For Indirect Only