Hydro AccuDose 3874GBA-2 Manuals

2 pdf manual(s) Hydro AccuDose 3874GBA-2 for free download (Document Types: Manual , Quick user manual)

Hydro AccuDose 3874GBA-2 Manual  Thumbnail

Hydro AccuDose 3874GBA-2 Manual  [PDF] (4 pages)

  • Identifier: id-1332637
  • Brand: Hydro
  • Device: Hydro AccuDose 3874GBA-2 Water Dispenser
  • Type: Manual , PDF
  • Key Aspects: Efficiency and Calibration Tips, Control Panel and Interface Navigation, Error Code Explanations
  • UPD Date: 18.07.2026
  • Source File: 1395122.pdf
  • Pages: 4
  • Description: Detailed product documentation for the Hydro AccuDose 3874GBA-2.
Pages Preview:
  • Hydro AccuDose 3874GBA-2 Manual  preview - page 2
  • Hydro AccuDose 3874GBA-2 Manual  preview - page 3
  • Hydro AccuDose 3874GBA-2 Manual  preview - page 4
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Installation and Operation: 1. Remove cabinet cover. Drill holes for the three wall anchors with a 7mm drill bit, using the cabinet back as a template for correct spacing of the mounting screws. Install mounting anchors, and then screws in top two anchors. Slide key holes in cabinet back over screw heads, tighten screws, then install bottom screw. Do not mount more than 1.8 metres above the bottom of the concentrate container, nor below the highest concentrate level (never mount concentrate higher than the proportioner). 2. Select metering tips (up to 4) for the selector valve (see next two sections). Push each tip firmly into a separate hose barb extending from the selector valve. A tip with no hole (clear plastic) can be used to block any valve port not being used. (This may be used for dispensing water only.) 3. Cut tubing supplied for chemical inlet (6mm ID) into lengths required so that tubes will reach from barbs on selector valve to bottom of concentrate containers. For each inlet tube, slide a weight over one end and slip end over the barb on a foot valve. Slide weight down to foot valve and attach opposite end of each tube over one of the hose barbs on the selector valve. 4. Push tubes from each side through the notches in the cabinet. 5. Place foot valve end of supply tubes into concentrate containers. REMEMBER TO CHECK FOOT VALVE STRAINERS PERIODICALLY FOR CLOGGING: CLEAN IF NECESSARY. 6. A short discharge tube is used with a 4 LPM (grey) eductor – Model 3875GB-2 ; minimum tube length is 20 cm for correct operation. A longer tube (1.2 m) is used with a 16 LPM (yellow) eductor – Model 3874GB-2. Slide end of tube over eductor discharge outlet. The hose hook supplied with Model 3874GB-2 may be installed on the long tube to allow it to hang from dispenser when not in use. 7. Replace cabinet cover. Push the sides in, behind the latch holes, to snap the cover in place. The two screws provided may be installed in the holes in the cabinet sides to prevent easy removal of cover. 8. Connect water supply hose of at least 13mm ID to water inlet swivel. (Minimum 1.76 Bar pressure, with water running, is required for correct operation.) Connect opposite end of hose to water supply. Turn water supply on. 9. Purge air from the system by depressing the buttons briefly. 10. Push button to start flow of desired water/concentrate solution, and hold until supply tube is primed (filled). Then push the button whenever dispensing is desired, and release button to stop flow of solution. If you wish to be able to lock the button in the "on" position: Clip or bend the two tabs behind the lower front portion of the button. (See diagram below.) This allows the button to be fully depressed and allows it to latch in the "on" position. TO UNLOCK PULL BUTTON OUT. AccuDose Series Proportioner Models 3874GB-2 & 3875GB-2 Package Contains: 1. Proportioner unit. 2. Chemical inlet tubing . 3 Foot valves (4) and weights (4). 3. Discharge tube. 4. Metering tip kit. 5. Mounting hardware. 6. Hook for discharge tube (Model 3874GB-2 only). 7. Instruction sheet. Clip or bend these tabs to depress button into locked position.
Hydro AccuDose 3874GBA-2 Quick user manual Thumbnail

Hydro AccuDose 3874GBA-2 Quick user manual [PDF] (4 pages)

  • Identifier: id-2130240
  • Brand: Hydro
  • Device: Hydro AccuDose 3874GBA-2 Dispenser
  • Type: Quick user manual, PDF
  • Key Aspects: Efficiency and Calibration Tips, Basic Configuration Guidelines, Unpacking and Inspection Guidelines
  • UPD Date: 14.08.2026
  • Source File: 2157397.pdf
  • Pages: 4
  • Description: Official user handbook for the Hydro AccuDose 3874GBA-2.
Pages Preview:
  • Hydro AccuDose 3874GBA-2 Quick user manual preview - page 2
  • Hydro AccuDose 3874GBA-2 Quick user manual preview - page 3
  • Hydro AccuDose 3874GBA-2 Quick user manual preview - page 4
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Installation and Operation: 1. Remove cabinet cover. Install the short, white inner discharge tubes on the outlets of the eductors. They go over the smaller barbed parts on the bottom of the eductors. These tubes must be in place for the eductors to function. The inner discharge tube for the 3.5 GPM (yellow) eductor has a yellow flooding ring inside it. The inner discharge tube for the 4 LPM (grey) eductor has a grey flooding ring inside it. Install the end of the tube nearest the flooding ring on the eductor's inner discharge barb. To ensure the IDTs are on correctly, the metal rings must be above the small barbs. 2. Drill holes for the three wall anchors with a 6mm drill bit, using the cabinet back as a template for correct spacing of the mounting screws. Install mounting anchors, and then screws in top two anchors. Slide key holes in cabinet back over screw heads, tighten screws, then install bottom screw. Do not mount more than 1.8 metres above the bottom of the concentrate container, or below the highest concentrate level (never mount concentrate higher than the proportioner). 3. Select metering tips (up to 4) for the selector valve (see next two sections). Push each tip firmly into a separate hose barb extending from the selector valve. A tip with no hole (clear plastic color) can be used to block any valve port not being used. (This may be used for dispensing water only.) 4. Cut tubing supplied for chemical inlet (6mm ID) into lengths required so that tubes reach from barbs on selector valve to bottom of concentrate containers. For each inlet tube, slide a weight over one end and slip end over the barb on a footvalve. Slide weight down to foot valve and attach opposite end of each tube over one of the hose barbs on the selector valve. 5. Slide tubes from each side through the notches in the cabinet. 6. Place footvalve ends of supply tubes into concentrate containers. REMEMBER TO CHECK FOOT VALVE STRAINERS PERIODICALLY FOR CLOGGING: CLEAN IF NECESSARY. 7. A short discharge tube is used with a 4 LPM (grey) eductor – Model 3875GBA-2 ; minimum tube length is 20 cm for correct operation. A longer tube (1.2m) is used with a 14 LPM (yellow) eductor – Model 3874GBA-2. Slide end of tube over inner discharge tube and onto eductor discharge outlet. The hose hook supplied with Model 3874GBA- 2 may be installed on the long tube to allow it to hang from dispenser when not in use. 8. Replace cabinet cover. Push the sides in, behind the latch holes, to snap the cover in place. The two screws provided may be installed in the holes in the cabinet sides to prevent easy removal of cover. 9. Connect water supply hose of at least 13mm ID to water inlet swivel. (Minimum 1.76 Bar pressure, with water running, is required for correct operation.) Connect opposite end of hose to water supply. Turn water supply on. 10. Purge air from the system by pressing the buttons briefly. There may be some water discharge from the eductor vents until the air is purged. 11. Push button to start flow of desired water/concentrate solution, and hold until supply tube is primed (filled). Then push the button whenever dispensing is required, and release button to stop flow of solution. If you wish to be able to lock the button in the "on" position: Clip or bend the two tabs behind the lower front portion of the button. (Seediagram below.) This allows the button to be fully depressed and allows it to latch in the "on" position. TO UNLOCK, PULL THE BUTTON OUT! 12. It is essential that the discharge hose is not obstructed. If discharge is restricted, water will flow out of the eductor vents. Do not start to operate the dispenser with liquid in the discharge tube. AccuDose 3874GBA-2 & 3875GBA-2 with HydroGapTM Air Gap Eductors Package Contains: 1. Proportioner unit. 2. Chemical inlet tubing . 3 Foot valves (4) and weights (4). 3. Discharge tube. 4. Metering tip kit. 5. Mounting hardware. 6. Hook for discharge tube (Model 3874GBA-2 only). 7. Instruction sheet. Clip or bend these tabs to depress button into locked position.

Similar Manuals in the Dispenser Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Vestergaard LifeStraw

LifeStraw Operation & user’s manual - IQ3D2E

3 974 166 17-08-2026 view all manuals
GLASCRAFT Probler

PDF User Manual (@7SPZ8A), GLASCRAFT Probler Dispenser (15-03-2026)

30 924 222 15-03-2026 view all manuals
Sureshot Dispensing Systems AC-VP1

User Guide: Sureshot Dispensing Systems AC-VP1 (D9A9OC, Upd.01-05-2026)

32 986 208 01-05-2026 view all manuals
Labelmate LD-100RS-SS

Dispenser #ZTV5YI

2 939 160 26-03-2026 view all manuals
Hilti HDE 500-A22

#59T3P5: HDE 500-A22 Dispenser Operating instructions manual

238 1094 186 20-06-2026 view all manuals
Air Wolf Alpha Series

PDF Manual (@99ZKUF), Air Wolf Alpha Series Dispenser (30-03-2026)

7 42 7 30-03-2026 view all manuals