INPUT 2x (0...10V/0...20mA) RUN/ X 12 L+ I1 I2 M1 M2 U1 U2 L+ M M ESC OK Q1 L1 1 2 1 2 1 2 1 2 I1 I2 I3 I4 I5 I6 I7 I8 N Q2 Q3 Q4 IE(LAN) MAC ADDRESS LAN ESC OK Q1 L1 1 2 1 2 1 2 1 2 I1 I2 I3 I4 I5 I6 I7 I8 N Q2 Q3 Q4 IE(LAN) MAC ADDRESS LAN 35 4 ESC OK Q1 L1 1 2 1 2 1 2 1 2 I1 I2 I3 I4 I5 I6 I7 I8 N Q2 Q3 Q4 IE(LAN) MAC ADDRESS LAN L1 N Expansion Interface I3...I6: fast inputs (used for counting) Outputs Inputs FE terminal Ethernet communication status LED When there are voltage peaks on the supply line, provide protection in the form of a varistor (MOV) UMOV = Urated x 1.2 (e.g. S10K275) Ethernet (10/100 Mbit/s) Micro SD card Mechanical coding sockets Power supply 2 x 1.5 mm2 / 1 x 2.5 mm2 Requirements for field wiring terminals: Wire range: 1.5 mm to 2.5 mm2 2 Conductor material: Cu Insulation temperature rating: 75 oC Tightening torque: 0.5 Nm to 0.6 Nm I1 digital or AI3 analog (0...10 V) I2 digital or AI4 analog (0...10 V) I7 digital or AI1 analog (0...10 V) I8 digital or AI2 analog (0...10 V) (Front and bottom views) (Side views) Mounting slides Use of FL1F IDEC SmartRelay Base Modules in hazardous locations All dimensions are in mm Warnung: Explosionsgefahr – Die Geräte erst trennen, wenn die Stromversorgung unterbrochen wurde, bzw. sicher ist,dass der Einsatzbereich frei von entzündlichen Konzentrationen ist. Warning: Explosion hazard – Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations. Avviso: Pericolo di esplosione – Scollegare le apparecchiature solo dopo aver disinserito l'alimentazione ed essersi accertati di operare in un luogo privo di concentrazioni infiammabili. Waarschuwing: Ontploffingsgevaar – Koppel apparatuur niet los, terwijl er spanning op staat of alleen wanneer u zeker weet dat het gebied vrij is van ontvlambare concentraties. Advertencia: Peligro de explosión – No desconectar los aparatos a menos que se haya desconectado la alimentación eléctrica o que el área pueda considerarse no peligrosa. Attention: Danger d’explosion – Ne débranchez les appareils qu’une fois l’alimentation en courant coupée ou si la zone d’implantation de l’appareil est une zone non dangereuse. Uyarı: Patlama tehlikesi – Cihazı devrede akım varken veya kullanım alanında yanıcı konsantrasyonlar olduğu biliniyorsa ayırmayın. Внимание: Взрывоопасно — Не отсоединяйте оборудование, не убедившись, что электропитание отключено или на участке отсутствует концентрация воспламеняющихся веществ. 警告: 爆炸危险 – 当电路处于通电状态或未确知产品处于非易燃区域内时,请 勿断开设备连接。 警告: 爆発の危険 -回路が動作している場合、または引火性雰囲気の場所 であることがわかっている場合は、本機器の電源の接続を切断しない でください。 71.5 90 60 55 Available for FL1F-H12RCE / FL1F-B12RCE and FL1F-H12SCD modules only. For dual/optional usage of input terminals, see IDEC SmartRelay User manual. 12/24 VAC/VDC 10 A 2 A 100 ... 240 VAC 10 A 3 A 100 VDC 0.2 A 0.2 A 240 VDC 0.1 A 0.1 A max. 100.000 typ. 20 days Ambient temperature: 0℃...+55℃ max. 95 % 0.2 kg 0.2 kg 1 2 Hole for M4 screw Tightening torque 0.8 Nm to 1.2 Nm All dimensions in mm Expansion modules Base Module 98 +/- 0.3 1 2 2 2 Hole pattern for wall mounting +0.2 53.5 - 0.0 +0.2 35.5 - 0.0 +0.2 n x 35.5 - 0.0 Mounting slides are shifted at the back side of the device before a wall mounting. Shift both outside. Earth ground Ethernet cable (IDEC recommends you use a standard Category 5 shielded twisted-pair Ethernet cable with a shielded RJ45 connector on each end.) Ethernet status LED IDEC SmartRelay is already connected to Ethernet Status LED IDEC SmartRelay is receiving/ sending data across Ethernet Flashing orange Steady green Connecting the Ethernet interface ESC OK Q1 L1 1 2 1 2 1 2 1 2 I1 I2 I3 I4 I5 I6 I7 I8 N Q2 Q3 Q4 IE(LAN) MAC ADDRESS OUTPUT 4xRELAY/10A LAN ESC OK Q1 L1 1 2 1 2 1 2 1 2 I1 I2 I3 I4 I5 I6 I7 I8 N Q2 Q3 Q4 IE(LAN) MAC ADDRESS OUTPUT 4xRELAY/10A LAN For use in a pollution degree 2 environment Module Can be used in hazardous locations Warnung: Explosionsgefahr – Der Austausch eines oder mehrerer Bestandteile könnte die Eignung des Gerätes für Gerätegruppe I, Gerätekategorie 2 beeinträchtigen. Warning: Explosion hazard – Substitution of any components may impair suitability for Class I, Division 2. Avviso: Pericolo di esplosione – La sostituzione di un qualsiasi componente può rendere l'apparecchiatura non idonea agli ambienti di classe I, divisione 2. Waarschuwing: Ontploffingsgevaar – Vervanging van onderdelen kan ervoor zorgen dat de apparatuur niet meer geschikt is voor klasse I, zone 2. Advertencia: Peligro de explosión – En caso de sustituir cualquier componente el aparato puede perder la homologación para el grupo I, categoría II. Attention: Danger d’explosion – Le remplacement de composants peut entraîner la perte de la conformité de l’appareil à la classe I, division 2. Uyarı: Patlama tehlikesi – Herhangi bir parça değişimi cihazın Sınıf I, Bölüm 2 için uygunluğunu olumsuz etkileyebilir. Внимание: Взрывоопасно — Замена любых компонентов может привести кнепригодности оборудования к безопасной эксплуатации в условиях класса I раздел 2. 警告: 爆炸危险 – 更换任意部件均可能会降低产品在爆炸危险场所(Class I, Division 2)使用时的安全性。 警告: 爆発の危険 - 部品を交換すると、Class I、Division 2に対する本装置 の適合性を損なう場合があります。 경고: 폭발 위험 – 구성품을 교체하면 클래스 I, 디비전 2의 적합성에 맞지 않 을 수 있습니다. RUN/STOP L+ I1 I2 I3 I4 M I5 I6 I7 I8 Q1 M M M M M M M M Q6 Q7 Q8 Q2 Q3 Q4 2015 Warnung: Gefährliche elektrische Spannung! Kann zu elektrischem Schlag und Verbrennungen führen. Vor Beginn der Arbeiten Anlage und Gerät spannungsfrei schalten. Weitere Informationen finden Sie im Handbuch zu IDEC SmartRelay. Warning: Hazardous voltage can cause electrical shock and burns. Disconnect power before proceeding with any work on this equipment. You will find further information in the IDEC SmartRelay manual. ¡ Tensión peligrosa! Puede causar chòque eléctrico y quemaduras, Desconectar la alimentación antes de efectuar trabajo alguno on este equipo. Encontrarán más informaciones en el manual sobre IDEC SmartRelay. Attention: Tension dangereuse! Risque d’électrocution et de brûlure, Isoler cet appareil du réseau avant d’y intervenir pour travaux. Vous trouverez davantage d’informations dans le manuel de IDEC SmartRelay. Avviso: Le tensione pericolosa! Può causare elettroshock e ustioni. Prima di eseguire qualsiasi tipo di lavoro occorre togliere la tensione. Ulteriori informazioni si trovano nel manuale di IDEC SmartRelay. Uyarı: Tehlikeli voltaj elektrik şoku ve yanıklara neden olabilir. Bu aygıt üzerinde çalışma yapmadan önce enerjiyi kesin. Внимание: Опасное электрическое напряжение! Угроза получения электрического удара и ожогов. Перед началом работ отключить напряжение на установке и оборудовании. Дополнительную информацию Вы найдете в Справочнике по IDEC SmartRelay. 警告: 高压危险!会有电击和火灾危险。 工作前切断设备和仪器电源。 在 IDEC SmartRelay 使用手册中有详细说明。 警告: 取り付け、取り外し、配線作業及び、保守・点検は必ず電源を 切ってから行ってください。感電及び、火災の恐れがあります。 詳しくは、ユーザーズマニュアルをご参照ください。 Waarschuwing: Gevaarlijke elektrische spanning! Kan elektrische schok en brandwonden veroorzaken. Voor het begin van de werkzaamheden de stroomtoevoer naar de installatie en het toestel uitschakelen. Meer informatie vindt U in het handboek van IDEC SmartRelay. Advertencia: IDEC SmartRelay ılavuzunda daha fazla bilgi bulacaksınız. A5E36158304-AA 경고: 위험한 전압으로 인해 전기 쇼크 및 화상을 입을 수 있습니다. 본 장비를 사용하는 작업을 진행하기 전에 전원을 분리하십시오. IDEC SmartRelay 매뉴얼에서 자세한 내용을 확인하십시오. Dieses Gerät ist für den Einsatz in Industrie- und Wohnumgebungen geeignet, und es ist als elektromagnetisch verträglich registriert. Deshalb kann das Gerät nicht nur in Wohnumgebungen, sondern auch in anderen Bereichen eingesetzt werden. This equipment is for industrial and residential use, and has acquired the electromagnetic conformity registration. So, it can be used not only in residential area, but also other areas. Cet équipement est destiné à un usage industriel et domestique et a reçu un certificat de conformité électromagnétique. Il peut donc être utilisé dans les zones résidentielles et aussi ailleurs. Este equipo está diseñado para el uso industrial y residencial y dispone de la marca de conformidad electromagnética. Esto significa que puede utilizarse en otras áreas además de las residenciales. Questa apparecchiatura è classificata per l'uso domestico e industriale ed è conforme alle direttive sulla compatibilità elettromagnetica. Il suo utilizzo è quindi consentito non solo nelle aree residenziali ma anche in altri ambienti. Bu ekipman endüstriyel ve ev kullanımı içindir ve elektromanyetik uyumluluk kaydına sahiptir. Bu nedenle, sadece yerleşim alanlarında değil diğer alanlarda da kullanılabilir. Данное оборудование предназначено для применения в промышленных и жилых зонах и прошло регистрацию в соответствии с требованиями стандартов электромагнитной совместимости. Поэтому данное оборудование может использоваться не только в жилых, но и в других зонах. 本设备设计为工业使用和民用,并已取得电磁一致性认证,因此您不仅可 以在民用环境下使用本设备,也可以在其它环境下使用本设备。 본 장비는 산업용 및 주거용이며, 전자기 적합성 등록을 획득하였습니다. 따라서 거주 지역 뿐만 아니라 다른 지역에서도 사용할 수 있습니다. Deze apparatuur is voor industrieel en huishoudelijk gebruik en voldoet aan de eisen van elektromagnetische compatibiliteit. De apparatuur kan dus niet alleen in woongebieden, maar ook in overige gebieden worden gebruikt. 说明: 주: Note: Remarque: Nota: Nota: Not: Opmerking: Примечание: Hinweis: 경고: 폭발 위험 – 회로가 동작 중이거나 주변에 인화성 물질이 없다고 확인 되지 않은 경우 장비를 분리하지 마십시오. FL1F-H12RCE FL1F-B12RCE FL1F-H12RCC FL1F-B12RCC FL1F-H12RCA FL1F-B12RCA B-1820(0) FL1F-H12RCE/FL1F-B12RCE/FL1F-H12SCD FL1F-H12RCC/FL1F-B12RCC/FL1F-H12RCA/FL1F-B12RCA FL1F-H12SCD OUTPUT 4xRELAY/10A OUTPUT 4xRELAY/10A OUTPUT 4xRELAY/10A Resistive Inductive Class I, Div. 2, Group A, B, C, D T4 Class I, Zone 2, Group IIC, T4 De-En-Fr-Sp-It-Tr-Nl-Ru-Ch-Jp-Ko FL1F-H12RCE/-B12RCE L+ = 10.8...28.8 VDC I12VDC = 30...140 mA I24VDC = 15...90 mA I3...I6 = 1: > 8.5 VDC; I > 1.5 mA 0: < 5 VDC; I < 0.88 mA 1: > 8.5 VDC; I > 0.12 mA 0: < 5 VDC; I < 0.07 mA I1...I2 I7...I8 = L1 = 85...265 VAC I100VAC = 15...40 mA I240VAC = 15...25 mA I1...I8 = 1: > 79 VAC; I > 0.08 mA 0: < 40 VAC; I < 0.05 mA L+ = 100...253 VDC I100VDC = 5...10 mA I240VDC = 2...8 mA I1...I8 = 1: > 79 VDC; I > 0.13 mA 0: < 30 VDC; I < 0.06 mA FL1F-H12RCC/-B12RCC N M (0V) N < 240 VAC/VDC L1 L2 II = B16 ESC OK AC/DC 100...240V INPUT 8xAC/DC Q1 L1 1 2 1 2 1 2 1 2 I1 I2 I3 I4 I5 I6 I7 I8 N Q2 Q3 Q4 IE(LAN) MAC ADDRESS LAN max. 16 A N M L+ L+ M L DC DC AC L = 20.4...26.4 VAC I24VAC = 15...150 mA I1...I8 = 1: > 12 VAC; I > 2.6 mA 0: < 5 VAC; I < 1.2 mA L+ = 20.4 ... 28.8 VDC I24VDC = 15...130 mA I1...I8 = 1: > 12 VDC; I > 2.6 mA 0: < 5 VDC; I < 1.2 mA FL1F-H12RCA/-B12RCA L+ = 20.4...28.8 VDC I24VDC = 15...50 mA (without load) I3...I6 = 1: > 12 VDC; I > 2.1 mA 0: < 5 VDC; I < 0.9 mA 1: > 12 VDC; I > 0.18 mA 0: < 5 VDC; I < 0.07 mA I1...I2 I7...I8 = FL1F-H12SCD M L+ II ESC OK DC 24V INPUT 8xDC I1, I2 = AI3, AI4 (0...10V) I7, I8 = AI1, AI2 (0...10V) Q1 M M M M L+ I1 I2 I3 I4 I5 I6 I7 I8 M Q2 Q3 Q4 IE(LAN) MAC ADDRESS LAN = 24 VDC, 0.3 A max. 1.2 A (with max. load) N M (0V) M < 240 VAC/VDC L+ II = B16 max. 16 A ESC OK DC 12/24V INPUT 8xDC I1, I2 = AI3, AI4 (0...10V) I7, I8 = AI1, AI2 (0...10V) Q1 L+ 1 2 1 2 1 2 1 2 I1 I2 I3 I4 I5 I6 I7 I8 M Q2 Q3 Q4 IE(LAN) MAC ADDRESS LAN N M (0V) P2 < 240 VAC/VDC P1 II = B16 ESC OK Q1 1 2 1 2 1 2 1 2 I1 I2 I3 I4 I5 I6 I7 I8 Q2 Q3 Q4 IE(LAN) MAC ADDRESS LAN max. 16 A AC/DC 24V INPUT 8xAC/DC P1 P2 : : Cursor Cursor move select Warnung: Explosionsgefahr - Bestandteile erst dann austauschen, wenn die Stromversorgung abgeschaltet wurde bzw. bekannt ist, dass der Einsatzbereich ungefährlich ist. Warning: Explosion hazard – Do not replace any component unless power has been switched off or the area is know to be non- hazardous. Avviso: Pericolo di esplosione – Sostituire i componenti solo dopo aver disinserito l’alimentazione o essersi accertati di operare in un luogo sicuro. Waarschuwing: Explosiegevaar - Bestanddelen pas dan vervangen, wanneer de stroomvoorziening werd uitgeschakeld resp. bekend is dat de zone ongevaarlijk is. Advertencia: Peligro de explosión – No sustituir ningún componente, a menos que se haya desconectado la alimentación eléctrica o que el área pueda considerarse no peligrosa. Attention: Danger d’explosion – Ne procédez au remplacement de composants qu’une fois l’alimentation en courant coupée ou si la zone d’implantation de l’appareil n’est pas une zone dangereuse. Uyarı: Patlama tehlikesi – Parçaları ancak akım beslemesi kesilmişse veya kullanım yerinin tehlike altında olmadığı biliniyorsa değiştirin. Внимание: Взрывоопасно - заменять составные части только после отключения электропитания или если известно, что область применения не представляет опасности. 警告: 爆炸危险– 除非已将电源断开或者确知产品处于非危险区域, 否则请勿进行任何部件的更换。 警告: 爆発の危険- 使用場所が爆発の危険性があるかどうか分からない 場合は、電源を遮断せずにコンポーネントの交換・抜き差しを 行わないでください。 경고: 폭발 위험 - 전원을 끄지 않았거나 구역에 위험이 없다고 확인되지 않은 경우 구성품을 교체하지 마십시오. Network Setup Program Diagnostics ESC 2015-07-01 Wed 00:00 M: 7/9 7: 00000 6: 00000 AQ: 6/9 8: 00005 7: 00000 6: 00010 AI: 4/9 3: 00000 2: 00000 1: 00000 AI: 3/9 Q: 2/9 01234 0123456789 123456789 I: 1/9 ESC+C 9/9 ▲ ◀ ▶ ▼ ▶◀ ▶◀ ▶◀ ▶◀ ▶◀ ▶◀ ▶◀ ▶◀ Analog inputs Outputs Inputs Analog inputs 10+ 20+ 0 0123456789 123456789 10+ 20+ 4: 00000 5: 00000 3: 00000 2: 00000 1: 00000 AQ: 5/9 4: 00000 5: 00000 8: 00000 0123456789 123456789 10+ 20+ 30+ 40+ 0123456789 0123456789 0123456789 M: 8/9 50+ 0123456789 60+ 01234 Cursor keys Parameter assignment menu Analog outputs Analog outputs Flags Flags ▶◀ ESC Stop ▶◀ Date/time Programming menu Setup menu Main menu Prog Password Prog Name Memory Usage Prog Password? Edit Prog Set Parameter Clear Prog Clear Password Change Password Old Password? ▲ ▼ OK OK OK OK OK OK OK OK OK OK OK OK OK OK Clock Start Screen Msg Config Power-on Delay AQ BM AI NUM LCD Menu Language Clock Start Screen Msg Config Switch to OP AQ in Stop AQ Type Set Clock S/W Time Sync AI Refresh Time Tick Time Curr Char Set Contrast Backlight AQ1 Type AQ8 Type AQ1 Value AQ8 Value OK OK IP Address Set M/S Mode Network configuration menu Diagnostics menu Toggle Tools Hardware Software Connection FW Version EM Status MAC Address View Event Log Clear Event Log SD Card Ethernet Ping Transfer menu Copy Protect Load Prog <- Card Save Prog -> Card Start Setup Network Diagnostics Card Program 如果电源出现故障,在某些情况下,IDEC SmartRelay 永久保存功能 状态之前,会出现输入端电压中断的现象。此时,IDEC SmartRelay 会永久保存“IDEC SmartRelay - 输入”为状态 0 时所产生的功能值。 Bei Netzausfall fällt unter Umständen die Spannung an den Eingängen ab, bevor IDEC SmartRelay den Zustand der Funktionen remanent gespeichert hat. In diesem Fall speichert IDEC SmartRelay Funktionswerte remanent, die sich ergeben, wenn sich die IDEC SmartRelay-Eingänge im Zustand 0 befinden. After a power failure, the logical input level may drop to zero voltage before IDEC SmartRelay is able to save the functions to retentive memory. In this case, IDEC SmartRelay saves the function values determined during the zero state at its inputs to retentive memory. Unne panne de secteur peut entraîner le cas échéant une chute de tension aux entrées avant que IDEC SmartRelay ait pu sauvegarder l’état des fonctions de manière rémanente. Dans ce cas, IDEC SmartRelay sauvegarde les valeurs de fonctions de manière rémanente si les entrées IDEC SmartRelay se trouvent à l’état 0. En caso de cortarse la alimentción de red puede disminuir la tensión en las entradas antes de que IDEC SmartRelay memorice el estado de las funciones de forma remanente. En tal caso, IDEC SmartRelay guardará los valores que se obtienen cuando las entradas de IDEC SmartRelay se encuentran a 0. Se si verifica una caduta die rete, in determinante circostanze viene a mancare la tensione negli ingress! Prima che IDEC SmartRelay abbia menorizzato lo stato delle funzioni nella memoria a ritenzione. In questo caso IDEC SmartRelay memorizza nella memoria a ritenzione i valori delle funzioni forniti nel momento in cui lo stato degli ingressi di IDEC SamrtRelay è 0. Elektrik kesintisi sonrasında, fonksiyonlar IDEC SmartRelay tarafından kalıcıbelleğe kaydedilmeden önce lojik giriş seviyesi sıfır voltaja düşebilir. Bu durumda IDEC SmartRelay, girişlerinde sıfır durumu boyunca belirlenenfonksiyon değerlerini kalıcı fonksiyona kaydeder. Bij netuitval kaalt eventueel de spanning aan de ingangen voordat IDEC SmartRelay de toestand van de functies remanent heeft opgeslagen. In dat geval slaat IDEC SmartRelay functiewaarden remanent op, die resulteren als zich de IDEC SmartRelay-ingangen in de toestand 0 bevinden. При выпадении тока при определенных условиях происходит падение напряжения на входах прежде, чем IDEC SmartRelay запомнил состояния функций.В данном случае IDEC SmartRelay сохраняет те значений функций, которые образуются, если входы IDEC SmartRelay находятся в состоянии 0. 電源停止時、電圧の下降状態によりスマートリレーのCPUが停止する前に、 論理入力レベルがOFFになる場合があります。電源断時保持機能(REM) を有するファンクションブロック(自己保持、アップダウンカウンタ等)では、 その内容が正しく保持されない場合があります。 交流电压保护接线 为了抑制供电线路上的浪涌电压,您可以在供电电路上并联一个 金属氧化物压敏电阻(MOV)(例如:S10K275压敏电阻)。要 确保压敏电阻的工作电压至少比 IDEC SmartRelay 的额定电压 高20%。 Schutzbeschaltung bei Wechselspannung Bei Spannungsspitzen auf der Versorgungsleitung können Sie einen Metalloxid-Varistor (MOV) einsetzen. Achten Sie darauf, dass die Arbeitsspannung des Varistors mindestens 20% höher ist als die Nennspannung (z.B. S10K275). Suppressor Circuit with Alternating Current For voltage peaks on the supply line you can install a metal-oxide varistor (MOV). Note that the working voltage of the varistor is at least 20% greater than the rated voltage (e.g. S10K275). Circuit de protection pur courant alternatif En cas de pointes de tension sur la ligne d’alimentation, vous pouvez recourir à un varistor métal-oxyde (MOV). Veillez à ce que la tension de service du varistor soit supérieure d’au moins 20% à la tension nominale (exp. S10K275). Cableado de protección para corriente alterna En caso de crestas de tensión en la línea de alimentación, puede Ud. emplear un varistor de óxido metálico (MOV). Téngase en cuenta que la tensión de trabajo del varistor debe ser por lo menos 20% mayor que la tensión nominal (p.ej. S10K275). Circuito di protezione con corrente alternata In presenza di picchi di tensione sul cavo di alimentazione, si può impiegare un varistore all’ossido di metallo (MOV). Fare attenzione a che la tensione di lavoro del varistore sia più elevata della tensione nominale di almeno il 20% (ad esempio S10K275). Alternatif Akımlı Bastırıcı Devre Besleme hattında oluşan voltaj pikleri için bir metal oksit varistör (MOV) monte edebilirsiniz. Varistörün çalışma voltajı anma voltajından en az %20 daha büyük olmalıdır (örn. S10K275). Veiligheidsbedrading bij wisselstroom Bij spanningspieken op de aanvoerleiding kunt u gebruik makan van een metaaloxidevaristor (MOV). Let erop dat de werkspanning van de varistor minstens 20% hoger is dan de nominale spanning (bijv. S10K275). Схема защиты при переменном токе При пиковых напряжениях в линии электроснабжения Вы можете применять металооксидный варистор (MOV). Следить за тем, чтобы рабочее напряжение варистора было как минимум на 20% выше номинального напряжения. 交流電流サプレッサ回路 電源ラインのピーク電圧対策として、金属酸化物製バリス タ(MOV)を設置することができます。バリスタの使用電圧 は、定格電圧より20%以上高い必要があることに、注意し てください (例. S10K275)。 전원 장애 후, IDEC SmartRelay 가 영구 메모리에 함수를 저장하기 전에 논리적 입력 레벨이 영(0)으로 떨어질 수 있습니다. 이러한 경우에 IDEC SmartRelay 는 영(0) 상태 중에 입력값에서 확인된 함수 값을 영구 메모리에 저장합니다. 교류를 이용한 억제 회로 공급 라인의 피크 전압을 위해 금속 산화 배리스터(MOV)를 설치할 수 있습니다. 배리스터의 작동 전압은 정격 전압보다 최소한 20% 더 크다는 점에 주의하십시오(예: S10K275). PNP NPN OUTPUT 4xRELAY/10A OUTPUT 4xRELAY/10A OUTPUT 4xRELAY/10A OUTPUT 4xRELAY/10A OK

Document Preview & Text Transcription

User’s Manual FL9Y-B1789(0) IDEC SmartRelay Manual Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] IDEC SmartRelay Manual i Legal information - Warning notice system Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of IDEC products Note the following: Copyright © IDEC CORPORATION All rights reserved The reproduction, distribution or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights reserved, in particular in the event of patents being granted or the registration of a utility model or design. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. WARNING IDEC products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by IDEC. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] IDEC SmartRelay Manual ii Preface With IDEC SmartRelay you have acquired a logic module that meets the stringent quality requirements of ISO 9001. You can use IDEC SmartRelay in many fields of applications. Due to its high functionality and easy operation, IDEC SmartRelay offers you the utmost efficiency for almost any application. Purpose of this manual This IDEC SmartRelay manual provides you with information about the creation of circuit programs, about the installation and use of Base Modules with more enhanced features, the FL1F-RD1 (Text Display with Ethernet interfaces), and IDEC SmartRelay expansion modules. IDEC SmartRelay's place in information technology The wiring information in your IDEC SmartRelay manual is also found in the IDEC SmartRelay Product Info included with all devices. For further information on programming the IDEC SmartRelay on your PC, refer to the Online Help for WindLGC. WindLGC is IDEC SmartRelay programming software for PCs. It runs under Windows® (including Windows XP®, Windows 7®, and Windows 8®). It helps you to get started with IDEC SmartRelay and to write, test, print out and archive your programs, independent of IDEC SmartRelay. Guide The manual contains the following chapters: • Getting started with IDEC SmartRelay • IDEC SmartRelay installation and wiring • Programming IDEC SmartRelay • IDEC SmartRelay functions • Web server • UDF (User-Defined Function) • Data Log • Configuring IDEC SmartRelay • Using memory cards • Security • IDEC SmartRelay software • Applications Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] Preface IDEC SmartRelay Manual iii The manual also includes appendices A - F, which follow the chapters. Valid range of this manual The manual applies to devices of series FL1F. New features of the IDEC SmartRelay The following features are new for the IDEC SmartRelay FL1F devices: • Ethernet communication support by all Base Modules Each Base Module is equipped with an RJ45 interface and a two-color status LED for Ethernet communication. • New text display (FL1F-RD1) with enhanced features – The Text Display module is available with two Ethernet interfaces. These two Ethernet interfaces can also function as a two-port switcher. You can connect the Text Display with a Base Module, a PC, or another Text Display through the Ethernet interfaces. Text Display can connect with different Base Modules through IP address selection. – Text Display provides a three-pin (P1, P2, and FE) terminal for power connection. – Text Display has three main menu commands available, respectively for the IP address selection of a Base Module, the remote settings of the connected Base Module, and the independent configuration of the Text Display. • Support of 6-line display and three backlight colors Both the IDEC SmartRelay onboard display and Text Display support a 6-line character display and three backlight colors (white/amber/red). The IDEC SmartRelay onboard display can display a maximum of 16 Western European characters or 8 Asian characters per line. Text Display can display a maximum of 20 Western European characters or 10 Asian characters per line. • Increased maximum I/O connections IDEC SmartRelay supports a maximum of 24 digital inputs, 20 digital outputs, 8 analog inputs and 8 analog outputs. • Built-in Web server in Base Modules IDEC SmartRelay provides you with easy access through Internet browsers. With the Web server function, you can access the Base Module using a connected device (PC, tablet or smart phone) by entering the IP address of the IDEC SmartRelay module in the Web browser of the connected device. • Enhanced functions added to special function blocks – Message texts: The IDEC SmartRelay support a 6-line message text display and ticking messages, as well as message text display on the Web server. You can enble the tick setting for each display line by setting the block parameters. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]