Lantronix EMG 8500 Manuals
4 pdf manual(s) Lantronix EMG 8500 for free download (Document Types: Quick start manual, Operation & user’s manual)
Lantronix EMG 8500 Quick start manual [PDF] (2 pages)
- Identifier: id-1588993
- Brand: Lantronix
- Device: Lantronix EMG 8500 Gateway
- Type: Quick start manual, PDF
- Key Aspects: Routine Functionality Testing, Regulatory Compliance and Standards, FAQ Section for Common Queries
- UPD Date: 17.05.2026
- Source File: 1591721.pdf
- Pages: 2
- Description: Service and user manual for the Lantronix EMG 8500.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 1. HARDWARE OVERVIEW 3. HARDWARE INSTALLATION The front console port allows a dumb terminal or PC with terminal emulation software to locally access management functions and connected devices. The device ports allow simple and flexible connections to serial devices using adapters and a standard CAT5 cable. Connect one end of the CAT5 cable to the device port and the other end to an adapter that attaches to the serial console of the target system. For example, to connect a PC to the console port of the EMG 8500, you need the RJ45 to DB9F Adapter and a standard CAT5 cable which is supplied with the unit. The default communication parameters for the device ports and console ports are: • 9600 baud • 1 stop bit • 8 data bits • No flow control • No parity 2. CONNECTING THE EMG 8500 Front View Back View Reversed by Default EMG™ 8500 Quick Start Guide Edge Management Gateway 1. CTS (In) 2. DSR (In) 3. RX (In) 4. GND 5. GND 6. TX (Out) 7. DTR (Out) 8. RTS (Out) 1. RTS (Out) 2. DTR (Out) 3. TX (Out) 4. GND 5. GND 6. RX (In) 7. DSR (In) 8. CTS (In) Console Port (RS-232) Device Ports (RS-232) ! Thank you for choosing Lantronix. Please register the EMG 8500 in order to receive notifications for firmware and documentation updates at www.lantronix.com/product-registration. Default Pin Assignments EMG 8500 Quick Start Guide Accessories Part Number Quantity External Universal AC (100W, 12V) Power Supply 520-0164-00 1 North American Power Cord - 110V AC power cord, 8 ft (2.43m), RoHS 500-041-R 1 RJ45 to DB9F Adapter 200.2070A 1 RJ45 to RJ45, CAT5 Cable, 6.6 ft (2 m) 200.0062 1 RJ45 Loopback Cable 500-153 1 Additional I/O and Connectivity FRUs are available and sold separately. varies varies START WHAT’S IN THE BOX The EMG 8500 unit offers up to 8 RJ45 (RS-232) or USB serial device port connections in two user-swappable, front I/O module device bays. The attached equipment requires an available console, AUX, or serial port (RS-232). Dual Ethernet or dual SFP ports provide in-band management access, allowing remote management of equipment using familiar tools such as Telnet or Secure Shell (SSH). Two user-swappable connectivity module bays on the back of the EMG unit provide out-of-band management access via LTE cellular modem FRU, or a local terminal can be used. In the event that the IP network is unavailable, the EMG 8500 unit can fail-over to the secondary connectivity interface. Once connected, the user has access to the server or IT equipment’s command line interface (CLI) via the console port to perform maintenance or management tasks. *DIO adapter is available and sold separately. All EMG 8500 models are compatible with a variety of equipment, including: • Switches • Routers • Firewalls • Servers • UPS systems • PBX systems • Telecom switches • PDU (supported brands) 1. Install the unit on a desktop or other flat, horizontal surface. You may optionally mount the EMG 8500 in a 19-inch rack or on a wall using the optional mount kit accessories. Warning: If rack mounting the EMG, do not block the air vents on the sides of the unit. If mounted in an enclosed rack, it is recommended that the rack have a ventilation fan. 2. Connect the equipment to the numbered device ports on the front of the unit using the appropriate cables and adapters. 3. Connect the unit to the network using the upper network port (Ethernet 1). 4. Connect the power cord to apply power. The top front LED turns green to indicate that power is ON and at least one of the Ethernet ports has a link or both Ethernet ports are disabled. The LED blinks red if none of the enabled Ethernet ports has a link. 5. Wait about a minute and a half for the boot process to complete. The first time you power up the EMG unit, Eth1 tries to obtain its IP Address via DHCP. View this IP Address by running Lantronix Provisioning Manager application or by connecting a terminal to the console port to access the command line interface. Software Reversible DIO* LEDs Device Ports (Modular) Bay 1 Bay 2 Console Port Micro SD USB Port Connectivity Ports (Modular) Bay 1 Bay 2 Ethernet SFP Power input EMG851210SP with USB and RJ45 FRUs shown. Additional FRU combinations are available. Not Reversible
Lantronix EMG 8500 Quick start manual [PDF] (2 pages)
- Identifier: id-1975122
- Brand: Lantronix
- Device: Lantronix EMG 8500 Gateway
- Type: Quick start manual, PDF
- Key Aspects: Safety Recommendations and Warnings, System Limitations and Considerations, Error Code Explanations
- UPD Date: 15.04.2026
- Source File: 2312738.pdf
- Pages: 2
- Description: Official installation manual for the Lantronix EMG 8500.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 Device Ports (Modular) 1. CTS (In) 2. DSR (In) 3. RX (In) 4. GND 5. GND 6. TX (Out) 7. DTR (Out) 8. RTS (Out) Reversed by Default Device Ports (RS-232) Software Reversible 1. HARDWARE OVERVIEW 3. HARDWARE INSTALLATION The front console port allows a dumb terminal or PC with terminal emulation software to locally access management functions and connected devices. The device ports allow simple and flexible connections to serial devices using adapters and a standard CAT5 cable. Connect one end of the CAT5 cable to the device port and the other end to an adapter that attaches to the serial console of the target system. The default communication parameters for the device ports and console ports are: • 9600 baud • 1 stop bit • 8 data bits • No flow control • No parity Note: EMG 8500 device ports are reversed by default, and are software configurable. 2. CONNECTING THE EMG 8500 Back View EMG™ 8500 Quick Start Guide Edge Management Gateway 1. RTS (Out) 2. DTR (Out) 3. TX (Out) 4. GND 5. GND 6. RX (In) 7. DSR (In) 8. CTS (In) Console Port (RS-232) ! Thank you for choosing Lantronix. Please register the EMG 8500 in order to receive notifications for firmware and documentation updates at www.lantronix.com/product-registration. Default Pin Assignments EMG 8500 Quick Start Guide Accessories Part Number Quantity External Universal AC (100W, 12V) Power Supply ACC-520-0164-00 1 North American Power Cord - 110V AC power cord, 8 ft (2.43m), RoHS ACC-500-041-R 1 RJ45 to DB9F Adapter ACC-200.2070A 1 RJ45 to RJ45, CAT5 Cable, 6.6 ft (2 m) ACC-200.0062 1 RJ45 Loopback Cable ACC-500-153 1 Rubber feet with adhesive 120-008-R 4 pieces Additional I/O and Connectivity FRUs are available and sold separately. varies varies START WHAT’S IN THE BOX The EMG 8500 unit offers up to 8 RJ45 (RS-232) or USB serial device port connections in 2 user-swappable, front I/O module device bays. *Front DIO adapter is available and sold separately. 1. Install the unit on a desktop or other flat, horizontal surface. Rack mount and wall mount kits are available as optional accessories. 2. Install the I/O modules on the front of the unit and the connectivity modules on the back. Warning: Always remove the power cord prior to installing or removing a connectivity or I/O module. Failure to do so could damage the unit. 3. Connect the equipment to the device ports on the front of the unit using the appropriate cables and adapters. 4. Connect the unit to the network using the upper network port (Ethernet 1 or SFP 1). Connectivity Ports (Modular) Bay 1 Bay 2 Power Ethernet SFP input Front View *DIO LEDs Console Port Micro SD USB EMG851210SP with USB and RJ45 FRUs shown. Additional FRU combinations are available. Not Reversible Warning: If rack mounting the EMG, do not block the air vents on the sides of the unit. If mounted in an enclosed rack, it is recommended that the rack have a ventilation fan. The back of the EMG 8500 unit offers up to 2 connectivity ports for out-of-band management in 2 user-swappable module bays. 5. Connect the power cord to apply power. 6. The top front LED turns green to indicate that power is ON and at least one of the Ethernet ports has a link or both Ethernet ports are disabled. The LED blinks red if none of the enabled Ethernet ports has a link. 7. Wait about a minute and a half for the boot process to complete. The first time you power up the EMG unit, Eth1 tries to obtain its IP Address via DHCP. Bay 2 Bay 1
Lantronix EMG 8500 Operation & user’s manual [PDF] (416 pages)
- Identifier: id-1494209
- Brand: Lantronix
- Device: Lantronix EMG 8500 Gateway
- Type: Operation & user’s manual, PDF
- Key Aspects: Package Contents and Accessories List, Hardware Verification Checklists, Efficiency and Calibration Tips
- UPD Date: 12.04.2026
- Source File: 1504220.pdf
- Pages: 416
- Description: Official user handbook for the Lantronix EMG 8500.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Part Number PMD-00008 Revision A October 2019 EMG™ Edge Management Gateway User Guide EMG 8500
Lantronix EMG 8500 Operation & user’s manual [PDF] (482 pages)
- Identifier: id-1709698
- Brand: Lantronix
- Device: Lantronix EMG 8500 Gateway
- Type: Operation & user’s manual, PDF
- Key Aspects: Product Performance Metrics, Hardware Setup Instructions, End-of-Life Handling and Disposal
- UPD Date: 17.04.2026
- Source File: 1727511.pdf
- Pages: 482
- Description: Professional operation guide for the Lantronix EMG 8500.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Part Number PMD-00008 Revision C April 2020 EMG™ Edge Management Gateway User Guide EMG 8500 EMG 7500
Similar Manuals in the Gateway Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
ZyXEL Communications C4000LZ |
User Guide: ZyXEL Communications C4000LZ (LKZ481, Upd.10-03-2026) |
14 | 288 | 44 | 10-03-2026 | view all manuals | |
Forcepoint NGFW 51 |
NGFW 51 (Gateway ePDF Guide, #43W7X8) |
9 | 799 | 184 | 12-07-2026 | view all manuals | |
IntesisBox IBOX-BAC-MBM |
IBOX-BAC-MBM Installation sheet - H67I4T |
2 | 971 | 185 | 07-05-2026 | view all manuals | |
Panduit SmartZone E24 |
Panduit SmartZone E24 Manual (Operation & user’s manual), @1W5DCM |
56 | 922 | 185 | 20-03-2026 | view all manuals | |
D-Link DI-701 - Gateway |
D-Link DI-701 - Gateway Manual (Technical manual), @GGD65X |
50 | 0.33 Mb | 896 | 189 | 23-07-2026 | view all manuals |
Carel CloudGate |
CloudGate (Gateway ePDF User Guide, #7W6BI1) |
2 | 456 | 92 | 08-04-2026 | view all manuals |