LEGRAND PW-100 Manuals
2 pdf manual(s) LEGRAND PW-100 for free download (Document Types: Installation instructions manual)
LEGRAND PW-100 Installation instructions manual [PDF] (16 pages)
- Identifier: id-1329911
- Brand: LEGRAND
- Device: PW-100 Switch
- Type: PDF
- Key Aspects: Regulatory Compliance and Standards, Operational Mode Explanations, Control Panel and Interface Navigation
- UPD Date: 26.06.2026
- Source File: 1397848.pdf
- Pages: 16
- Description: Step-by-step guide for the LEGRAND PW-100.
Click to expand and read text
Wattstopper ® Passive Infrared Wall Switch Occupancy Sensor (version 3) Détecteur de présence interrupteur mural infrarouge passif (v3) Sensor de ocupación con interruptor a la pared y tecnología de infrarrojo pasivo (v3) Installation Instructions • Instructions d’Installation • Instrucciones de Instalación No: 23950 – 10/18 rev. 3 Catalog Numbers • Les Numéros de Catalogue • Números de Catálogo: PW-100/PW-100-347/PW-200/PW-200-347 Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China DESCRIPTION AND OPERATION The PW Passive Infrared Wall Switch sensors use advanced passive infrared (PIR) technology. The PW sensor can turn a load on, and hold it on as long as the sensor detects occupancy. After no movement is detected for the selected time delay, the lights switch off. A “walk-through” mode can turn lights off after only 3 minutes, if no activity is detected after 30 seconds following an occupancy detection. The PW-100 has one relay and one ON/OFF button. The PW-200 contains two relays and two ON/OFF buttons to allow control of one or two loads independently. Pressing a button toggles the state of the corresponding relay. PW sensors contain a light level sensor. If adequate daylight is present, the sensor holds the load OFF until light levels drop, even if the area is occupied. In the PW-200, light level only affects the load on Relay 2. Users can overrule the hold OFF function by pressing the ON/OFF button. See Light Level Adjustment. Turning Load(s) ON (ON Mode) The relays are programmed independently for either Auto ON or Manual ON. In either mode, the load can be turned ON or OFF using the ON/OFF button. Manual ON DIP 8 ON for Relay 1 DIP 9** ON for Relay 2 With an ON Mode DIP switch in the ON position, the occupant must press the ON/OFF button to turn ON the load. The sensor keeps the load ON until no motion is detected for the selected time delay. There is a 30 second re-trigger delay. If occupancy is detected during the delay, the sensor turns the load back ON. After the re-trigger delay elapses the ON/OFF button must be pressed to turn ON the load. Auto ON DIP 8 OFF for Relay 1 DIP 9** OFF for Relay 2 With an ON Mode DIP switch in the OFF position, the load turns ON and OFF automatically based on occupancy. If the load is turned OFF manually, Presentation Mode operation applies. This prevents the load from turning ON automatically after it was deliberately turned OFF. Pressing the button to turn lights ON returns the sensor to Auto ON mode. ** PW-100: Switch 9 is not used. PW-200: Switch 9 default is ON to comply with CA Energy Commission Title 24 bi-level switching requirements. SPECIFICATIONS Voltages: PW-100 & PW-200........................................120/277VAC, 50/60Hz Load Limits for each relay: @120VAC................................0-800W tungsten or ballast, 1/6 HP @277VAC..............................................................0-1200W ballast Load Type Compatibility: Incandescent, fluorescent, magnetic or electronic ballast Horsepower Rating (each relay).........................1/6 HP @120VAC Time Delay Adjustment................................................... 5 to 30 minutes Walk-Through Mode.................3 minutes if no activity after 30 sec. Test Mode....................... 5 sec. for 10 min. with DIP switch setting PIR Adjustment................................................. High or Low (DIP switch) Light Level Adjustment........................................................ 8fc to 180+fc Alerts............................................................Selectable Audible & Visual US Patents: 5640113, 6617560 PW-100 PW-200
LEGRAND PW-100 Installation instructions manual [PDF] (16 pages)
- Identifier: id-1981961
- Brand: LEGRAND
- Device: PW-100 Kitchen Appliances
- Type: PDF
- Key Aspects: FAQ Section for Common Queries, End-of-Life Handling and Disposal, Environmental Factors and Restrictions
- UPD Date: 11.05.2026
- Source File: 2305898.pdf
- Pages: 16
- Description: User guidebook for the LEGRAND PW-100.
Click to expand and read text
Wattstopper ® Passive Infrared Wall Switch Occupancy Sensor (version 3) Détecteur de présence interrupteur mural infrarouge passif (v3) Sensor de ocupación con interruptor a la pared y tecnología de infrarrojo pasivo (v3) Installation Instructions • Instructions d’Installation • Instrucciones de Instalación No: 23950 – 1/17 rev. 2 Catalog Numbers • Les Numéros de Catalogue • Números de Catálogo: PW-100/PW-100-347/PW-200/PW-200-347 Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China SPECIFICATIONS Voltages: PW-100 & PW-200 .......................................120/277VAC, 50/60Hz PW-100-347 & PW-200-347 ...............................347VAC, 50/60Hz Load Limits for each relay: @120VAC ...............................0-800W tungsten or ballast, 1/6 HP @277VAC .............................................................0-1200W ballast @347VAC .............................................................0-1500W ballast Load Type Compatibility: Incandescent, fluorescent, magnetic or electronic ballast Horsepower Rating (each relay) ........................1/6 HP @120VAC Time Delay Adjustment .................................................. 5 to 30 minutes Walk-Through Mode ................3 minutes if no activity after 30 sec. Test Mode ...................... 5 sec. for 10 min. with DIP switch setting PIR Adjustment ................................................ High or Low (DIP switch) Light Level Adjustment ....................................................... 8fc to 180+fc Alerts ...........................................................Selectable Audible & Visual US Patents: 5640113, 6617560 PW-100 PW-100 - 347 DESCRIPTION AND OPERATION The PW Passive Infrared Wall Switch sensors use advanced passive infrared (PIR) technology. The PW sensor can turn a load on, and hold it on as long as the sensor detects occupancy. After no movement is detected for the selected time delay, the lights switch off. A “walk-through” mode can turn lights off after only 3 minutes, if no activity is detected after 30 seconds following an occupancy detection. The PW-100 has one relay and one ON/OFF button. The PW-200 contains two relays and two ON/OFF buttons to allow control of one or two loads independently. Pressing a button toggles the state of the corresponding relay. PW sensors contain a light level sensor. If adequate daylight is present, the sensor holds the load OFF until light levels drop, even if the area is occupied. In the PW-200, light level only affects the load on Relay 2. Users can overrule the hold OFF function by pressing the ON/OFF button. See Light Level Adjustment. Turning Load(s) ON (ON Mode) The relays are programmed independently for either Auto ON or Manual ON. In either mode, the load can be turned ON or OFF using the ON/OFF button. Manual ON DIP 8 ON for Relay 1 DIP 9** ON for Relay 2 With an ON Mode DIP switch in the ON position, the occupant must press the ON/OFF button to turn ON the load. The sensor keeps the load ON until no motion is detected for the selected time delay. There is a 30 second re-trigger delay. If occupancy is detected during the delay, the sensor turns the load back ON. After the re-trigger delay elapses the ON/OFF button must be pressed to turn ON the load. Auto ON DIP 8 OFF for Relay 1 DIP 9** OFF for Relay 2 With an ON Mode DIP switch in the OFF position, the load turns ON and OFF automatically based on occupancy. If the load is turned OFF manually, Presentation Mode operation applies. This prevents the load from turning ON automatically after it was deliberately turned OFF. Pressing the button to turn lights ON returns the sensor to Auto ON mode. ** PW-100: Switch 9 is not used. PW-200: Switch 9 default is ON to comply with CA Energy Commission Title 24 bi-level switching requirements. PW-200 PW-200 - 347
PW-100: Related Instructions
® GF 11/2005-01 NT 80048LB • Accessoires de raccordement • Connection accessories • Anschluß-Zubehör • Accesorios de conexión • Accessori di colle Complete instruction guide for the LEGRAND DPX 630 Cables and connectors. This guide describes setup, software configuration, device features.
Note: One individual blind control operates a single motor. Characteristics LE00387AA Voltage 100 - 240 VA Frequency 50 - 60 Hz 2 x 1,5 mm2 or 1 x 2,5 mm2 Stand Owner’s guide for the LEGRAND Pro 21 Controller. This guide describes features and operational guidelines, firmware installation, repair references.
www.numericups.com NEW ENERGY TO POWER USER AND INSTALLATION MANUAL NEW ENERGY TO POWER Onfiniti 5-10 kVA www.numericups.com A Operating handbook for the LEGRAND NUMERIC Onfiniti UPS. It describes usage and installation steps, replacement parts, specifications, technical guidelines.
Smart Rack Controller User Guide Xerus™ Firmware v3.5.10 Copyright © 2019 Raritan, Inc. SRC_UserGuide_0A_3.5.10_E May 2019 255-80-0064-00 Operation instructions for the LEGRAND Raritan SRC-0100 Controller. The manual provides information on user preferences, operational safety, system checks.
779 14 673 66 779 11/13 673 66 - 779 13 2 RF 802.11a + 802.11bg 779 14 2 RF 802.11a + 802.11bg + RJ45 779 11 1 RF 802.11bg Power 1 PoE Injector IN OUT 1 IN OUT Complete usage guide for the LEGRAND 779 11 Wireless Access Point. The documentation includes specifications, application scenarios, security instructions, safety information.
(US) HDMI® HDBASET + USB-C®, 3.5MM, AND USB-A TO B OVER CAT EXTENDER WALL PLATE TRANSMITTER TO BOX RECEIVER - 4K 60HZ (FR) HDMI HDBASET + USB-C, 3,5 MM ET USB Installation reference manual for the LEGRAND C2G 30011 Receiver. This reference includes configuration options, energy usage, assembly reference.
Similar Manuals in the Kitchen Appliances, Switch Category
202040 Princess Juice Extractor Nederlands 3 English 7 Français 11 Deutsch 15 Español 20 Italiano 24 Svenska 28 Dansk 32 Norsk 36 Suomi 40 Português 44 Ε User guide for the Princess 202040 Kitchen Appliances. This guide explains technical procedures for assembly reference, compatibility information, user instructions.
s Preface, Contents Product Overview 1 System Integration 2 Installation 3 Commissioning 4 Operator Input 5 Process Interface 6 Diagnostics 7 Appendix 8 Index S Complete instruction guide for the Siemens SIMATIC Vision Sensor VS 130-2 Kitchen Appliances. It outlines maintenance guidelines and product safety, configuration options, operational guidelines.
90DIB500IM02 – 5.2 Secure Communications Installation and Operation Manual DIB-500 R4.1 Digital Indoor Base Station Installation and Operation Manual Owner’s manual for the Rohde & Schwarz DIB-500 R4.1 Kitchen Appliances. This manual covers installation, operation, and wiring setup, usage examples, power management, product specifications.
DK Vinkøleskab ..................................................... 2 NO Vinkjøler .......................................................... 6 SE Vinkyl ... Service manual for the Melissa 16620018 Kitchen Appliances. The manual contains instructions for functional overview, safety guidelines, software installation, testing procedures.