LEGRAND Wattstopper UW-100 Manuals

3 pdf manual(s) LEGRAND Wattstopper UW-100 for free download (Document Types: Installation instructions, Installation instructions manual)

LEGRAND Wattstopper UW-100 Installation instructions [PDF] (4 pages)

  • Identifier: id-1329958
  • Brand: LEGRAND
  • Device: Wattstopper UW-100 Kitchen Appliances
  • Type: PDF
  • Key Aspects: FAQ Section for Common Queries, Glossary of Technical Terms, Unpacking and Inspection Guidelines
  • UPD Date: 02.08.2026
  • Source File: 1397801.pdf
  • Pages: 4
  • Description: Operation instructions for the LEGRAND Wattstopper UW-100.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Wattstopper ® Ultrasonic Wall Switch Occupancy Sensor (V3) Installation Instructions • Instructions d’Installation • Instrucciones de Instalación No: 24786 – 10/18 rev. 1 Catalog Numbers • Les Numéros de Catalogue • Números de Catálogo: UW-100/UW-200 Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China DESCRIPTION AND OPERATION The UW Ultrasonic Wall Switch sensors employ 40kHz ultrasonic technology in a single-gang wall switch unit. The UW sensor can turn a load ON, and hold it ON as long as the sensor detects occupancy. After no movement is detected for the selected time delay, the lights switch OFF. A “walk-through” mode can turn lights OFF after only 3 minutes, if no activity is detected after 30 seconds following an occupancy detection. The UW-100 has one relay and one ON/OFF button. The UW-200 contains two relays and two ON/OFF buttons to allow control of one or two loads independently. Pressing a button toggles the state of the corresponding relay. UW sensors contain a light level sensor. If adequate daylight is present, the sensor holds the load OFF until light levels drop, even if the area is occupied. In the UW-200, light level only affects the load on Relay 2. Users can overrule this function by pressing the ON/OFF button. See Light Level Adjustment. Turning ON the Load (ON Mode) The relays are programmed independently for either Auto ON or Manual ON. In either mode, the load can be turned ON or OFF using the ON/OFF button. Manual ON DIP #8 ON for Relay 1 DIP #9 ON for Relay 2 With an ON Mode DIP Switch in the ON position, the occupant must press the ON/OFF button to turn ON the load. The sensor keeps the load ON until no motion is detected for the selected time delay. There is a 30-second re-retrigger delay. If occupancy re-triggers during the delay (see Trigger Mode), the sensor turns the load back ON. After the re-trigger delay elapses the ON/OFF button must be pressed to turn ON the load. Auto ON DIP #8 OFF for Relay 1 DIP #9 OFF for Relay 2 With an ON Mode DIP Switch in the OFF position, the load turns ON and OFF automatically based on occupancy. If the load is turned OFF manually, Presentation Mode operation applies. This prevents the load from turning ON automatically after it was deliberately turned OFF. Pressing the button to turn lights ON returns the sensor to Auto ON mode. ** UW-100: Switch 8 is not used. UW-200: Switch 8 default is ON to comply with CA Energy Commission Title 24 bi-level switching requirements. Model # Relay Default ON Mode DIP Switch # Setting UW-100 1 Manual ON 8 ON UW-200 1 2 Auto ON Manual ON 8 9 OFF ON NOTE: Shaded cells in the following tables indicate default operation and switch setting. Presentation Mode This is a feature of the Auto ON mode.When both relays are manually turned OFF the UW holds the lights OFF until no motion has been detected for the duration of the Time Delay. With subsequent occupancy, the UW turns the load ON. If both relays are ON and one relay is manually turned OFF this relay remains OFF until both the Time Delay and retrigger delay expires for the relay that is ON, after that time the ON Mode control settings again apply. Time Delays The UW sensor holds the load ON until no motion is detected for the selected time delay. Select the time delay using DIP Switch settings. In the UW-200, both relays use the same delay. SPECIFICATIONS Voltages: UW-100 & UW-200.................... 120/277VAC, 50/60Hz Load Limits for each relay: @120VAC..............0-800W tungsten or ballast, 1/6 HP @277VAC............................................0-1200W ballast Load Type Compatibility: Incandescent, fluorescent, magnetic, or electronic ballast Horsepower Rating (each relay).......1/6 HP @120VAC Time Delay Adjustment.................................5 to 30 minutes Walk-Through Mode.... 3 min. if no activity after 30 sec. Test Mode.... 5 sec. for 10 min. with DIP Switch setting Ultrasonic Adjustment.....Minimum to Maximum (trimpot), OFF Frequency............................................................40kHz Light Level Adjustment......................................8fc to 180+fc Alerts..........................................Selectable Audible & Visual US Patents: 5640113, 6617560 UW-100 UW-200

LEGRAND Wattstopper UW-100 Installation instructions manual [PDF] (8 pages)

  • Identifier: id-1712658
  • Brand: LEGRAND
  • Device: Wattstopper UW-100 Kitchen Appliances
  • Type: PDF
  • Key Aspects: Error Code Explanations, Hardware Setup Instructions, Product Performance Metrics
  • UPD Date: 13.06.2026
  • Source File: 1724551.pdf
  • Pages: 8
  • Description: Device operation guide for the LEGRAND Wattstopper UW-100.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Installation Instructions Specifications Voltages: UW-100 & UW-200 . . . . . . . . . . . . . . . . . 120/277VAC, 50/60Hz UW-100-347 . . . . . . . . . . . . . . . . . . . . . . . . . . 347VAC, 50/60Hz Load Limits for each relay: @120VAC . . . . . . . . . . . . 0-800W tungsten or ballast, 1/6 HP @277VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-1200W ballast @347VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-1500W ballast Load Type Compatibility: Incandescent, fluorescent, magnetic or electronic ballast Horsepower Rating (each relay) . . . . . . . . . 1/6 HP @120VAC Time Delay Adjustment . . . . . . . . . . . . . . . . . . . . 5 to 30 minutes Walk-Through Mode . . 3 minutes if no activity after 30 sec. Test Mode . . . . . . 5 sec. for 10 min. with DIP switch setting Ultrasonic Adjustment . . . Minimum to Maximum (trimpot), Off Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40kHz Light Level Adjustment . . . . . . . . . . . . . . . . . . . . . . . 8fc to 180+fc Alerts . . . . . . . . . . . . . . . . . . . . . Selectable Audible & Visible US Patents: 5640113 6617560 UW-100/UW-100-347/UW-200 v3 Ultrasonic Wall Switch Occupancy Sensor UW-100 & UW-100-347 UW-200 Santa Clara, CA 95050 800.879.8585

LEGRAND Wattstopper UW-100 Installation instructions manual [PDF] (8 pages)

  • Identifier: id-2361665
  • Brand: LEGRAND
  • Device: Wattstopper UW-100 Switch
  • Type: PDF
  • Key Aspects: Emergency Shutdown Procedures, Risk Mitigation and Accident Prevention, Environmental Factors and Restrictions
  • UPD Date: 23.04.2026
  • Source File: 1925939.pdf
  • Pages: 8
  • Description: Instruction and reference manual for the LEGRAND Wattstopper UW-100.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
S a n ta Clara, CA 95050 8 0 0 . 8 7 9 . 8 5 8 5 Specifications Vo l tages: UW-100 & UW-200 . . . . . . . . . . . . .1 2 0 / 2 3 0 / 2 7 7 VAC, 50/60Hz U W - 1 0 0 - 3 4 7 . . . . . . . . . . . . . . . . . . . . . . . . . .3 4 7 VAC, 50/60Hz Load Limits for each re l a y : @ 1 2 0 VAC . . . . . . . . . . . .0-800W tungsten or ballast, 1/6 HP @230 or 277VAC . . . . . . . . . . . . . . . . . . . . . . .0-1200W ballast @ 3 4 7 VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-1500W ballast Load Type Compatibility: I n ca n d e s cent, fluore s cent, magnetic or ele c t ronic ballast H o rs e p ower Rating (each re l a y ) . . . . . . . . .1/6 HP @120VAC Time Delay Adjust m e n t . . . . . . . . . . . . . . . . . . . .5 to 30 minute s Wa l k - T h rough Mode . .3 minutes if no activity after 30 sec. Te st Mode . . . 5 sec. at initial power up or DIP switch re s e t U l t rasonic Adjust m e n t . . .Minimum to Maximum (trimpot), Off Fre q u e n c y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 0 k H z Light Level Adjust m e n t . . . . . . . . . . . . . . . . . . . . . . .8 fc to 180+fc A le r t s . . . . . . . . . . . . . . . . . . . . . .S e le c ta b le Audible & Visible US Pa tents: 5640113 6 6 1 7 5 6 0 B 2 U W - 1 0 0 / U W - 1 0 0 - 3 4 7 / U W - 2 0 0 U l t rasonic Wall Switc h O ccupancy Sensor U W-100 & UW- 1 0 0 - 3 4 7 U W- 2 0 0

Wattstopper UW-100: Related Instructions

KEOR COMPACT
LEGRAND KEOR COMPACT
20.03.2026 16 pages

NO NC OUT-3 J4 NO NC OUT-2 J2 NO NC OUT-1 J1 NO NC OUT-4 J5 NO NC OUT-5 J7 NO NC OUT-6 J8 1st 2nd J9 J3 1st 2nd J6 LE12723AA – 20/12 The copying, re Product usage manual for the LEGRAND KEOR COMPACT UPS. This manual elaborates on operation, technical overview, hardware setup, safety information.

Keor SPE 750
LEGRAND Keor SPE 750
15.07.2026 28 pages

Technical operations guide for the LEGRAND Keor SPE 750 UPS. It explains maintenance and technical troubleshooting, product maintenance, connectivity options, installation guides.

PW-100
LEGRAND PW-100
12.08.2026 16 pages

Wattstopper ® Passive Infrared Wall Switch Occupancy Sensor (version 3) Détecteur de présence interrupteur mural infrarouge passif (v3) Sensor de ocupación Official user handbook for the LEGRAND PW-100 Switch. This manual provides guidance on user settings, daily usage, network setup.

430 522
LEGRAND 430 522
03.09.2026 19 pages

430 522 User manual • Caméra couleur dôme motorisée jour/nuit 3,5-94,5 mm 27X • 3.5-94.5 mm 27X motorized day/night dome colour camera • Cámara de cú Operation instructions for the LEGRAND 430 522 Security Camera. The manual outlines system configuration and service instructions, software configuration, internal layout, calibration steps.

QMotion QMOLEEDZRX
LEGRAND QMotion QMOLEEDZRX
15.04.2026 3 pages

TITLE BOX PAGE ONLY. DO NOT MAKE FILM • DO NOT PRINT IF YOU HAVE ANY QUESTIONS REGARDING SPECIFICATIONS OR REQUIRE ADDITIONAL FILE FORMATTING, PLEASE CONTACT Device instruction guide for the LEGRAND QMotion QMOLEEDZRX Extender. It provides technical information on supported accessories, usage examples, operational safety.

0 546 00
LEGRAND 0 546 00
31.05.2026 2 pages

0 502 99 legrand legrand LE08193AA 0 546 00 / 01 / 15 / 16/ 20 / 21 / 25 / 26/ 27 / 28 / 29 / 31 / 33 / 35 / 36 / 37 / 70 / 72 / 73 / 90 / 91 / 92 6 535 60/61/6 Owner’s manual for the LEGRAND 0 546 00 Kitchen Appliances. The guide offers support information and installation support, setup instructions, safety.

Similar Manuals in the Kitchen Appliances, Switch Category

DUET
NatComm DUET
08.09.2026 12 pages

DUET SWICH USER GUIDE For Technical Assistance call the Manufacturers direct ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Suppl Service manual for the NatComm DUET Switch. It outlines installation and diagnostic information, software updates, operating modes.

Sentron WL
Siemens Sentron WL
27.08.2026 364 pages

      9239 9955 174 Bedienungsanleitung / Operating Instructions Bestell-Nr. / Order No.: 3ZX1812-0WL00-0AN2 s GEFAHR DANGER Gefährl Operating and setup manual for the Siemens Sentron WL Circuit breakers. It includes troubleshooting procedures and maintenance guidelines, operational guidelines, system setup.

ABC
Audioplex ABC
13.03.2026 1 pages

TECHNOLOGY ABC SWITCH 3 SOURCE SELECTOR SWITCH The ABC switch allows convenient selection of 3 stereo sources from a single wall mounted location. Prepare the w Product setup manual for the Audioplex ABC Switch. The document includes maintenance, detailing setup, daily usage.

BNI IOL-709-000-K006
Balluff BNI IOL-709-000-K006
17.04.2026 16 pages

BNI IOL-709-000-K006 BNI IOL-710-000-K006 IO-Link Sensor-Hub analog User’s Guide Operating manual for the Balluff BNI IOL-709-000-K006 Switch. This guide includes network setup, technical assistance, usage examples, hardware instructions.