Liebert PowerSure PST Manuals

1 pdf manual(s) Liebert PowerSure PST for free download (Document Types: Quick start manual)

Liebert PowerSure PST Quick start manual [PDF] (2 pages)

  • Identifier: id-1944418
  • Brand: Liebert
  • Device: PowerSure PST Surge Protector
  • Type: PDF
  • Key Aspects: Environmental Factors and Restrictions, Performance Optimization Tips, End-of-Life Handling and Disposal
  • UPD Date: 13.03.2026
  • Source File: 2343446.pdf
  • Pages: 2
  • Description: Complete device guide for the Liebert PowerSure PST.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
PowerSure™ PST Quick-Start Guide for 350-500VA; 120V WHAT’S IN THE BOX • Quick-Start guide • PowerSure family user manual on CD (also at www.liebert.com) • Warranty card • RJ-11 cord, 7 ft. (2.1 m) • USB cable, 6 ft. (1.8m) For more details, refer to the PowerSure user manual on CD. Para una información más detallada, consulte el manual del usuario de la familia PowerSure en el CD. Refer to Bottom for Cautionary Markings Power ON/OFF/ Alarm Silence Utility Indicator* (Green) Site Wiring Fault Indicator (Red) Fault Indicator* (Red/Green) USB port Circuit protector Output receptacles (surge protection only) Data Line Protection Connectors TOP OF UPS LEFT SIDE OF UPS RIGHT SIDE OF UPS Power cord 6.5 ft. (2m) Output receptacles (battery backup and surge protection) INSTALLATION Read all safety, installation and operating instructions in the PowerSure family user manual on the included CD or at www.liebert.com before operating the UPS. Adhere to all warnings on the unit and in the manual. 1. Install the UPS indoors in a controlled environment, where it cannot be accidentally turned off. Place it in an area of unrestricted airflow around the unit, away from water, flammable liquids, gases, corrosives and conductive contaminants. Maintain a minimum clearance of 4 inches (100mm) on each side of the UPS. Maintain an ambient temperature range of 32°F to 104°F (0°C to 40°C). 2. Plug the PST’s power cord into an AC outlet. Check the Site Wiring Fault Indicator on the rear; if it is illuminated, refer to the Troubleshooting section. 3. Plug any computers and monitors into the orange receptacles for battery backup and surge protection; other office machines that do not exceed the capacity of the UPS may be plugged into either of the two (2) black receptacles, which provide surge protection only. 4. Connect Phone/Fax/DSL/Internet/Modem devices to data line connectors. 5. Press and release the ON/OFF/Alarm Silence button to turn on the UPS. The UPS will beep and the Utility Indicator will illuminate (green). 6. Turn on connected equipment. Plug this type of equipment into black receptacles ONLY Plug computers, monitors, routers and cash registers into orange receptacles Inkjet printers Scanners Fax machines CONTROLS AND INDICATORS This button controls output power to the connected load and has three functions: •Turns the PowerSure PST ON •Turns the PowerSure PST OFF •Silences PowerSure PST alarms TURN THE UPS ON: Press and release the main ON/OFF button to start the UPS. An audible alarm will sound briefly. TURN THE UPS OFF: When the PST is ON, hold the main ON/OFF button down for more than 2 seconds to shut it down. An audible alarm will sound briefly. SILENCE AN ALARM: When a UPS alarm is active, press and release the main ON/OFF button to silence the audible alarm (Excep- tions: low battery, overload and overtempera- ture). DO NOT hold the button down for more than 2 seconds or the PST will shut down. CHECK THE PST’S CONDITION: Three sta- tus indicators on the front of the UPS illumi- nate to specify the status of the UPS (see Troubleshooting section for details). SITE WIRING FAULT INDICATOR (AMBER) The Site Wiring Fault Indi- cator on the top of thePST, as shown, illumi- nates amber when the UPS detects a line- neutral reversal or a poor neutral-ground. (See Troubleshooting Chart if indicator is illuminated.) Site Wiring Fault Indicator (Amber) Top of UPS SPECIFICATIONS Model Number PA350-120U PA500-120U Model Rating VA / W 350/225 500 / 300 DIMENSIONS: in (mm) Unit W x D x H 6.6 x 9.8 x 3.7 (168 x 250 x 95) 6.6 x 9.8 x 3.7 (168 x 250 x 95) Shipping W x D x H 9.4 x 13.8 x 5.6 (238 x 350 x 142) 9.4 x 13.8 x 5.6 (238 x 350 x 142) WEIGHT: lbs (kg) Unit 11.7 (5.3) 13.5 (6.1) Shipping 12.1 (5.5) 13.9 (6.3) INPUT AC PARAMETERS Surge Protection 603J Voltage Range Without Battery Operation 98VAC - 140VAC ±3VAC Frequency 57 - 63 Hz (±0.4Hz) Input Power Cord 6.5 ft.attached, w/ NEMA 5-15 P OUTPUT AC PARAMETERS Output Receptacles (3) NEMA 5-15R (orange) battery backup+surge protection (2) NEMA 5-15R (black) surge protection Voltage (Battery Mode) 120VAC ±8% Output Current 2.9 A 4.2 A Waveform (Battery Mode) Stepped Sinewave Frequency (Battery Mode) 60Hz ±1Hz Overload Warning >100% Overload Shutdown >110% BATTERY PARAMETERS Type Valve-regulated, nonspillable, lead acid Quantity x Voltage x Rating 1 x 12V x 5 Ah 1 x 12V x 7 Ah Transfer Time 4 – 6 ms typical Back-up Time: At 77°F (25°C), resistive loading, w/ fully charged batteries: Full load 5 minutes 3 minutes Half load 16 minutes 15 minutes Recharge Time 12 hours to 90% capacity, after full discharge into resistive load ENVIRONMENTAL Operating Temperature +32°F to + 104°F (0°C to +40°C) Storage Temperature +5°F to + 122°F (- 15°C to +50°C) Relative Humidity 0% to 95%, non- condensing Operating Elevation Up to 10,000 ft. (3000 m) at 86°F (30°C) w/o derating Audible Noise < 40 dBA, at 1 meter AGENCY Safety UL 1778, c-UL Listed Surge ANSI C62.41, Category A, Level 3, (IEEE 587, Category A); EN61000-4-5, Level 3, Criteria A ESD EN61000-4-2, Level 3, Criteria A Susceptibility EN61000-4-3, Level 2, Criteria A Electrical Fast Transient/Burst EN61000-4-4, Level 3, Criteria A Emissions FCC Part 15, Subpart B, Class B Harmonics EN61000-3-2 Conducted Immunity EN61000-4-6 Flicker EN61000-3-3 Transportation ISTA Procedure 1A COMMUNICATIONS The PowerSure PST has a USB interface port for communication that will work with the built-in Microsoft Power Manager software on the user’s PC, if the PC is so equipped. It will provide UPS status and man- ages the automatic, orderly shutdown of the computer. The UPS (USB) communications meets HID stan- dard, version 1.11. All USB models are compatible with Microsoft Windows 2000, Windows XP and Mac OS 10.2 or later. All USB models ship with a 6 ft. (1.8m) USB cable.

Liebert PowerSure PST: Surge Protector, UPS Category Related Instructions

DTK-SNAP-LITE Series
Ditek DTK-SNAP-LITE Series
17.05.2026 2 pages

Doc # INT-100010-001 Part No. 191129 Rev. 2 INSTALL INSTRUCTIONS DTK-SNAP-LITE Series DITEK Technical Support Available 24/7 1-888-472-6100 www.ditekcorp.com DITEK Corporation ONE DITEK CENTER 1720 Starkey Road Largo, FL 33771 INSTALLATION This Step-by-step user manual for the Ditek DTK-SNAP-LITE Series Surge Protector. It includes troubleshooting procedures and system parameters, software updates, support details.

HT600WSU2A
Cyber Power HT600WSU2A
09.07.2026 2 pages

CONGRATULATIONS ON YOUR PURCHASE Thank you for selecting the CyberPower HT600WSU2A Premium Surge Protector. This manual explains the features and operation of the HT600WSU2A. Please take a few moments to read this manual. FEATURES 1. Power Plug product into a Product setup manual for the Cyber Power HT600WSU2A Surge Protector. The manual describes startup procedures, product maintenance, safety.

3862-CON
Leviton 3862-CON
21.04.2026 2 pages

DESCRIPTION The Leviton Surge Protective Device (SPD) for ControlNet, Cat. No. 3862-CON, is designed as the primary line of protection from ControlNet line impulses and transients. The SPD is to be connected as a series unit in the ControlNet line. SPECIFICATI Complete technical documentation for the Leviton 3862-CON Surge Protector. The document includes setup validation, performance guidelines, repair references, user settings.

S4 Black Line II
INFOSEC UPS SYSTEM S4 Black Line II
29.05.2026 6 pages

Notice d'utilisation __________________________ 4 User Guide _________________________________ 5 مادختسلاا ليلد _________________________________ 6 User instruction manual for the INFOSEC UPS SYSTEM S4 Black Line II Surge Protector. It describes usage and product maintenance, functional overview, operating conditions.