Quick-Start Guide for 350-500VA; 120V

WHAT’S IN THE BOX • Quick-Start guide • PowerSure family user manual on CD (also at www.liebert.com) • Warranty card • RJ-11 cord, 7 ft. (2.1 m) • USB cable, 6 ft. (1.8m) For more details, refer to the PowerSure user manual on CD. Para una información más detallada, consulte el manual del usuario de la familia PowerSure en el CD. Refer to Bottom for Cautionary Markings Power ON/OFF/ Alarm Silence Utility Indicator* (Green) Site Wiring Fault Indicator (Red) Fault Indicator* (Red/Green) USB port Circuit protector Output receptacles (surge protection only) Data Line Protection Connectors TOP OF UPS LEFT SIDE OF UPS RIGHT SIDE OF UPS Power cord 6.5 ft. (2m) Output receptacles (battery backup and surge protection) INSTALLATION Read all safety, installation and operating instructions in the PowerSure family user manual on the included CD or at www.liebert.com before operating the UPS. Adhere to all warnings on the unit and in the manual. 1. Install the UPS indoors in a controlled environment, where it cannot be accidentally turned off. Place it in an area of unrestricted airflow around the unit, away from water, flammable liquids, gases, corrosives and conductive contaminants. Maintain a minimum clearance of 4 inches (100mm) on each side of the UPS. Maintain an ambient temperature range of 32°F to 104°F (0°C to 40°C). 2. Plug the PST’s power cord into an AC outlet. Check the Site Wiring Fault Indicator on the rear; if it is illuminated, refer to the Troubleshooting section. 3. Plug any computers and monitors into the orange receptacles for battery backup and surge protection; other office machines that do not exceed the capacity of the UPS may be plugged into either of the two (2) black receptacles, which provide surge protection only. 4. Connect Phone/Fax/DSL/Internet/Modem devices to data line connectors. 5. Press and release the ON/OFF/Alarm Silence button to turn on the UPS. The UPS will beep and the Utility Indicator will illuminate (green). 6. Turn on connected equipment. Plug this type of equipment into black receptacles ONLY Plug computers, monitors, routers and cash registers into orange receptacles Inkjet printers Scanners Fax machines CONTROLS AND INDICATORS This button controls output power to the connected load and has three functions: •Turns the PowerSure PST ON •Turns the PowerSure PST OFF •Silences PowerSure PST alarms TURN THE UPS ON: Press and release the main ON/OFF button to start the UPS. An audible alarm will sound briefly. TURN THE UPS OFF: When the PST is ON, hold the main ON/OFF button down for more than 2 seconds to shut it down. An audible alarm will sound briefly. SILENCE AN ALARM: When a UPS alarm is active, press and release the main ON/OFF button to silence the audible alarm (Excep- tions: low battery, overload and overtempera- ture). DO NOT hold the button down for more than 2 seconds or the PST will shut down. CHECK THE PST’S CONDITION: Three sta- tus indicators on the front of the UPS illumi- nate to specify the status of the UPS (see Troubleshooting section for details). SITE WIRING FAULT INDICATOR (AMBER) The Site Wiring Fault Indi- cator on the top of thePST, as shown, illumi- nates amber when the UPS detects a line- neutral reversal or a poor neutral-ground. (See Troubleshooting Chart if indicator is illuminated.) Site Wiring Fault Indicator (Amber) Top of UPS SPECIFICATIONS Model Number PA350-120U PA500-120U Model Rating VA / W 350/225 500 / 300 DIMENSIONS: in (mm) Unit W x D x H 6.6 x 9.8 x 3.7 (168 x 250 x 95) 6.6 x 9.8 x 3.7 (168 x 250 x 95) Shipping W x D x H 9.4 x 13.8 x 5.6 (238 x 350 x 142) 9.4 x 13.8 x 5.6 (238 x 350 x 142) WEIGHT: lbs (kg) Unit 11.7 (5.3) 13.5 (6.1) Shipping 12.1 (5.5) 13.9 (6.3) INPUT AC PARAMETERS Surge Protection 603J Voltage Range Without Battery Operation 98VAC - 140VAC ±3VAC Frequency 57 - 63 Hz (±0.4Hz) Input Power Cord 6.5 ft.attached, w/ NEMA 5-15 P OUTPUT AC PARAMETERS Output Receptacles (3) NEMA 5-15R (orange) battery backup+surge protection (2) NEMA 5-15R (black) surge protection Voltage (Battery Mode) 120VAC ±8% Output Current 2.9 A 4.2 A Waveform (Battery Mode) Stepped Sinewave Frequency (Battery Mode) 60Hz ±1Hz Overload Warning >100% Overload Shutdown >110% BATTERY PARAMETERS Type Valve-regulated, nonspillable, lead acid Quantity x Voltage x Rating 1 x 12V x 5 Ah 1 x 12V x 7 Ah Transfer Time 4 – 6 ms typical Back-up Time: At 77°F (25°C), resistive loading, w/ fully charged batteries: Full load 5 minutes 3 minutes Half load 16 minutes 15 minutes Recharge Time 12 hours to 90% capacity, after full discharge into resistive load ENVIRONMENTAL Operating Temperature +32°F to + 104°F (0°C to +40°C) Storage Temperature +5°F to + 122°F (- 15°C to +50°C) Relative Humidity 0% to 95%, non- condensing Operating Elevation Up to 10,000 ft. (3000 m) at 86°F (30°C) w/o derating Audible Noise < 40 dBA, at 1 meter AGENCY Safety UL 1778, c-UL Listed Surge ANSI C62.41, Category A, Level 3, (IEEE 587, Category A); EN61000-4-5, Level 3, Criteria A ESD EN61000-4-2, Level 3, Criteria A Susceptibility EN61000-4-3, Level 2, Criteria A Electrical Fast Transient/Burst EN61000-4-4, Level 3, Criteria A Emissions FCC Part 15, Subpart B, Class B Harmonics EN61000-3-2 Conducted Immunity EN61000-4-6 Flicker EN61000-3-3 Transportation ISTA Procedure 1A COMMUNICATIONS The PowerSure PST has a USB interface port for communication that will work with the built-in Microsoft Power Manager software on the user’s PC, if the PC is so equipped. It will provide UPS status and man- ages the automatic, orderly shutdown of the computer. The UPS (USB) communications meets HID stan- dard, version 1.11. All USB models are compatible with Microsoft Windows 2000, Windows XP and Mac OS 10.2 or later. All USB models ship with a 6 ft. (1.8m) USB cable.

SL-23275QS (9/03) Rev. 0

TROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the PowerSure PST experiences a problem. Use this information to determine whether external factors caused the problem. See Troubleshooting Chart for suggested remedy. GUIDE TO STATUS INDICATORS 1. The Fault indicator illuminates, indicating the UPS detected a problem. 2. An alarm sounds, alerting that the UPS requires attention. The alarm can be silenced except for low battery, overload and overtemperature warning conditions. 3. Utility and/or Battery indicators may be illuminated as a diagnostic aid to the operator, as shown below: Fault (Red) Site Wiring Fault (Amber) Utility/Battery (Green) Diagnosis/ Audible Alarm Normal Mode — — ON UPS is operating in Normal Mode; no beep. — — Flashing Battery Test has been initiated; no beep. — Flashing ON Site Wiring Fault; no beep. Flashing — ON The unit is overloaded; beep every half-second ON — ON The UPS has failed; continuous beep Flashing — — Unit has shut down due to overload; continuous beep ON — — The UPS shut down due to failure; continuous beep Battery Mode — — Flashing The UPS is operating in Battery mode; beep every 5 seconds. — — Flashing UPS battery is low; beep every half-second Flashing — Flashing The unit is overloaded; beep every half-second ON — Flashing The UPS has failed; continuous beep Fault Indicator Site Wiring Fault Indicator Utility/Battery Indicator ! + - TROUBLESHOOTING CHART If the UPS fails to operate properly, turn off the unit and repeat the steps in the Installation section of this manual. If the prob- lem persists, refer to the chart below: Problem Cause Solution UPS will not start Overload/ Short circuit Check the circuit protector on the side of the UPS. If it is tripped, reset it and restart the UPS. For further help, call your local dealer, Liebert representative or the Liebert Worldwide Support Group. UPS starts on battery, but will not switch to AC UPS not plugged in Plug in power cord securely. Circuit protector tripped Reset the circuit protector and restart the UPS. Power not available at utility receptacle Have the utility receptacle checked by a qualified electrician. Input voltage below threshold Wait until the voltage rises to an appropriate level or have the utility receptacle checked by a qualified electrician. AC overvoltage Wait until voltage lowers to an appropriate level or have the utility receptacle checked by a qualified electrician. UPS shuts down, Fault Indicator lit Overload/ Short circuit Check the circuit protector on the rear of the UPS. If it is tripped, reset it and restart the UPS. If the problem persists, disconnect some of the equipment from your UPS—the total wattage of your equipment must not exceed the capacity of the UPS. For further help, call your local dealer, Liebert representative or the Liebert Worldwide Support Group. Internal UPS fault Site Wiring Fault Indicator illuminated Line-neutral reversal/Poor ground connection Have the utility checked by a qualified electrician. UPS not providing expected backup time Overload Reduce load. Battery not charged due to a recent outage Recharge battery. MAINTENANCE The PowerSure PST UPS requires very little maintenance. Follow these practices to prevent problems. CLEANING THE UPS The following will help ensure trouble-free operation for years: • Vacuum dust from the ventilation intake occasionally. • Wipe the cover periodically with a dry cloth. MAINTAINING BATTERIES The batteries are valve-regulated, nonspillable, lead acid and must be kept charged to retain their design life. The UPS continuously charges the batteries when connected to the utility supply, even while the UPS is switched off. When storing the UPS, it is recommended to plug in the UPS for at least 24 hours every four to six months to ensure full recharge of the batteries. WARRANTY REGISTRATION To register for warranty protection: • Visit the Quick Links section of our Web site at: http://www.liebert.com • Click on Product Warranty Registration and fill in the form. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT US AT: US: 800-222-5877 Outside the US: 614-841-6755 [email protected]

Other Surge Protector Manuals