  • Key Aspects: Common Issue Diagnostic Flows, Technical Data and Parameters, Information on Regular Maintenance
  • Updated: 19.07.2026
  • Source File: 559778.pdf
  • Pages: 8
  • Description: Comprehensive setup guide for the Mitsubishi Electric PEA-RP200 WJA.
Mitsubishi Electric PEA-RP200 WJA Operation manual Main Page Preview

Operation manual [PDF] (16 pages)

  • Brand: Mitsubishi Electric
  • Model: PEA-RP200 WJA
  • Format: PDF
  • Key Aspects: Manufacturer Contact and Support Data, Efficiency and Calibration Tips, System Connectivity and Wiring Basics
  • Updated: 12.07.2026
  • Source File: 559780.pdf
  • Pages: 16
  • Description: User guidebook for the Mitsubishi Electric PEA-RP200 WJA.

Document Preview & Text Transcription

Air-Conditioners INDOOR UNIT PEA-RP170, 200, 250 WGA FOR USER OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. GB WT05223X02_cover_only EN 08.2.18, 5:37 PM 2 2 GB D F SW I NL E P 2 [Fig. 2.0.1] A Air outlet B Air inlet C Air filter [Fig. 2.0.2] A B C A LCD remote controller ON/OFF TEMP. A 5 A C B D [Fig. 5.0.1] A Air outlet C Air filter B Air inlet D Air filter handle WT05223X02-illust 08.2.18, 5:37 PM 2 3 GB D F I NL E SW P 1. Safety precautions 1) Outdoor unit Warning: • The outdoor unit must be installed on a stable, level surface, in a place where there is no accumulation of snow, leaves or rubbish. • Do not stand on, or place any items on the unit. You may fall down or the item may fall, causing injury. Caution: The outdoor unit should be installed in a location where air and noise emit- ted by the unit will not disturb the neighbours. 2) Indoor unit Warning: The indoor unit should be securely installed. If the unit is loosely mounted, it may fall, causing injury. 3) Remote controller Warning: The remote controller should be installed in such a way that children cannot play with it. 4) Drain hose Caution: Make sure that the drain hose is installed so that drainage can go ahead smoothly. Incorrect installation may result in water leakage, causing dam- age to furniture. 5) Power line, fuse or circuit breaker Warning: • Make sure that the unit is powered by a dedicated line. Other appliances connected to the same line could cause an overload. • Make sure that there is a main power switch. • Be sure to adhere to the unit’s voltage and fuse or circuit breaker ratings. Never use a piece of wire or a fuse with a higher rating than the one specified. 6) Grounding Caution: • The unit must be properly grounded. Never connect the grounding wire to a gas pipe, water pipe, lightning conductor or telephone grounding wire. If the unit is not grounded properly, electric shock may result. • Check frequently that the ground wire from the outdoor unit is properly connected to both the unit’s ground terminal and the grounding elec- trode. s Before operating the unit, make sure you read all the “Safety precautions”. s “Safety precautions” lists important points about safety. Please be sure to follow them. Symbols used in the text Warning: Describes precautions that should be observed to avoid the risk of injury or death to the user. Caution: Describes precautions that should be observed to prevent damage to the unit. Symbols put on the unit : Indicates an action that must be avoided. : Indicates that important instructions must be followed. : Indicates a part which must be grounded. : Beware of electric shock. (This symbol is displayed on the main unit label.) Warning: Carefully read the labels affixed to the main unit. 1.1. Installation s After you have read this manual, keep it and the Installation Manual in a safe place for easy reference whenever a question arises. If the unit is going to be operated by another person, make sure that this manual is given to him or her. Warning: • The unit should not be installed by the user. Ask the dealer or an author- ized company to install the unit. If the unit is installed improperly, water leakage, electric shock or fire may result. • Use only accessories authorized by Mitsubishi Electric and ask your dealer or an authorized company to install them. If accessories are in- stalled improperly, water leakage, electric shock or fire may result. • The Installation Manual details the suggested installation method. Any structural alteration necessary for installation must comply with local building code requirements. • Never repair the unit or transfer it to another site by yourself. If repair is performed improperly, water leakage, electric shock or fire may result. If you need to have the unit repaired or moved, consult your dealer. • The appliance is not intended for use by young children or infirm per- sons without supervision. • Young children should be supervised to ensure that they do not play with the appliance. Contents 1. Safety precautions ...................................................................................... 3 1.1. Installation ................................................................................. 3 1.2. During operation ........................................................................ 4 1.3. Disposing of the unit .................................................................. 4 2. Names and functions of various parts ........................................................ 4 3. Operation .................................................................................................... 5 3.1. Switching the unit ON/OFF........................................................ 6 3.2. Mode select ............................................................................... 6 3.3. Selecting a temperature TEMP. ............................................... 6 3.4. Selecting a fan speed ........................................................ 6 3.5. Setting the day of the week and time ........................................ 6 3.6. Using the timer .......................................................................... 7 3.7. Locking the remote controller buttons (Operation function limit controller) ................................................................................ 10 3.8. Other indications ..................................................................... 10 4. The smart way to use ............................................................................... 11 5. Caring for the machine ............................................................................. 11 6. Troubleshooting ......................................................................................... 12 7. Installation and transferring works, and checking ..................................... 13 8. Specifications ............................................................................................ 13 WT05223X02_en 08.2.18, 5:37 PM 3 4 GB D F I NL E SW P 2. Names and functions of various parts Indoor unit • Air inlet: Return the indoor air. • Filter: Part to remove visible dust and dirt. (For details on how to clean, refer to page 11.) • Air outlet: Blow the cooled/warmed air into the room. Model PEA-170, 200, 250 [Ceiling concealed type] [Fig. 2.0.1] (P.2) A Air outlet B Air inlet C Air filter LCD remote Controller • Check out your remote controller. Different controllers are used for different systems. [Fig. 2.0.2] (P.2) A LCD remote controller 1.2. During operation Caution: • Do not use any sharp object to push the buttons, as this may damage the remote controller. • Do not twist or tug on the remote controller cord as this may damage the remote controller and cause malfunction. • Never remove the upper case of the remote controller. It is dangerous to remove the upper case of the remote controller and touch the printed circuit boards inside. Doing so can result in fire and failure. • Never wipe the remote controller with benzene, thinner, chemical rags, etc. Doing so can result in discoloration and failure. To remove heavy stains, soak a cloth in neutral detergent mixed with water, wring it out thoroughly, wipe the stains off, and wipe again with a dry cloth. • Never block or cover the indoor or outdoor unit’s intakes or outlets. Tall items of furniture underneath the indoor unit, or bulky items such as large boxes placed close to the outdoor unit will reduce the unit’s effi- ciency. Warning: • Do not splash water over the unit and do not touch the unit with wet hands. An electric shock may result. • Do not spray combustible gas close to the unit. Fire may result. • Do not place a gas heater or any other open-flame appliance where it will be exposed to the air discharged from the unit. Incomplete combustion may result. Warning: • Do not remove the front panel or the fan guard from the outdoor unit when it is running. You could be injured if you touch rotating, hot or high- voltage parts. • Never insert fingers, sticks etc. into the intakes or outlets, otherwise in- jury may result, since the fan inside the unit rotates at high speed. Exer- cise particular care when children are present. • If you detect odd smells, stop using the unit, turn off the power switch and consult your dealer. Otherwise, a breakdown, electric shock or fire may result. • When you notice exceptionally abnormal noise or vibration, stop opera- tion, turn off the power switch, and contact your dealer. • Do not over-cool. The most suitable inside temperature is one that is within 5 °C of the outside temperature. • Do not leave handicapped people or infants sitting or standing in the path of the airflow from the air-conditioner. This could cause health prob- lems. Caution: • Do not direct the airflow at plants or caged pets. • Ventilate the room frequently. If the unit is operated continuously in a closed room for a long period of time, the air will become stale. In case of failure Warning: • Never remodel the air conditioner. Consult your dealer for any repair serv- ice. Improper repair work can result in water leakage, electric shock, fire, etc. • If the remote controller displays an error indication, the air conditioner does not run, or there is any abnormality, stop operation and contact your dealer. Leaving the unit as it is under such conditions can result in fire or failure. • If the power breaker is frequently activated, get in touch with your dealer. Leaving it as it is can result in fire or failure. • If the refrigeration gas blows out or leaks, stop the operation of the air conditioner, thoroughly ventilate the room, and contact your dealer. Leav- ing the unit as it is can result in accidents due to oxygen deficiency. When the air conditioner is not to be used for a long time • If the air conditioner is not to be used for a long time due to a seasonal change, etc., run it for 4 - 5 hours with the air blowing until the inside is completely dry. Failing to do so can result in the growth of unhygienic, unhealthy mold in scattered areas throughout the room. • When it is not to be used for an extended time, keep the [power supply] turned OFF. If the power supply is kept on, several watts or several tens of watts will be wasted. Also, the accumulation of dust, etc., can result in fire. • Keep the power switched ON for more than 12 hours before starting op- eration. Do not turn the power supply OFF during seasons of heavy use. Doing so can result in failure. 1.3. Disposing of the unit Warning: When you need to dispose of the unit, consult your dealer. If pipes are re- moved incorrectly, refrigerant (fluorocarbon gas) may blow out and come into contact with your skin, causing injury. Releasing refrigerant into the atmosphere also damages the environment. WT05223X02_en 08.2.18, 5:37 PM 4
Mitsubishi Electric PEA-RP200 WJA Installation manual Main Page Preview

Installation manual [PDF] (108 pages)

  • Brand: Mitsubishi Electric
  • Model: PEA-RP200 WJA
  • Format: PDF
  • Key Aspects: Operational Mode Explanations, Package Contents and Accessories List, Cleaning and Sanitization Methods
  • Updated: 18.05.2026
  • Source File: 825781.pdf
  • Pages: 108
  • Description: Complete service manual for the Mitsubishi Electric PEA-RP200 WJA.

Document Preview & Text Transcription

English INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. FOR INSTALLER Deutsch INSTALLATIONSHANDBUCH Zum sicheren und ordnungsgemäßen Gebrauch der Klimaanlage das Installationshandbuch gründlich durchlesen. FÜR INSTALLATEURE Français MANUEL D’INSTALLATION Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte. POUR L’INSTALLATEUR Español MANUAL DE INSTALACIÓN Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado. PARA EL INSTALADOR Italiano MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d’aria. PER L’INSTALLATORE Nederlands INSTALLATIEHANDLEIDING Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert. VOOR DE INSTALLATEUR Svenska INSTALLATIONSMANUAL Läs denna installationsmanual noga för säkert och korrekt bruk innan luftkonditioneringen installeras. FÖR INSTALLATÖREN Dansk INSTALLATIONSMANUAL Læs venligst denne installationsmanual grundigt, før De installerer airconditionanlægget, af hensyn til sikker og korrekt anvendelse. TIL INSTALLATØREN Português MANUAL DE INSTALAÇÃO Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado. PARA O INSTALADOR Ελληνικά ΕΓΧΕΙΡΙ∆ΙΟ Ο∆ΗΓΙΩΝ ΕΓΚΑΤΑΣΤΑΣΗΣ Για ασφάλεια και σωστή χρήση, παρακαλείστε διαβάσετε προσεχτικά αυτό το εγχειρίδιο εγκατάστασης πριν αρχίσετε την εγκατάσταση της μονάδας κλιματισμού. ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ Русский РУКОВОДСТВО ПО УСТАНОВКЕ Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по установке до выполнения установки кондиционера. ДЛЯ УСТАНОВИТЕЛЯ Türkçe MONTAJ ELKİTABI Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını monte etmeden önce bu elkitabını dikkatle okuyunuz. MONTÖR İÇİN Кондиционеры ВНУТРЕННИЙ БЛОК Air-Conditioners INDOOR UNIT PEA-RP200, 250WKA 2 3 3.2 [Fig. 3.2.1] 4 4.1 [Fig. 4.1.1] 5 5.1 [Fig. 5.1.1] [Fig. 5.1.2] 6 6.2 [Fig. 6.2.1] 200~300 150~200 50 50 1350 730 450 470 more than 20 30±10 more than 20 more than 100 60 23 1324 23 37 1250 1100 1100 800 1034 B C D A A E Keep the service space for the maintenance from the bottom when the heat exchanger is cleaned. A Access door B Electrical parts box C Air inlet D Air outlet E Ceiling surface Y X Z W L A A Center of gravity A B A Unit body B Lifting machine C D C E D C Nuts (field supply) D Washers (accessory) E M10 hanging bolt (field supply) 165 52 100 244 30 424 A B E C D F A Air inlet B Refrigerant piping (liquid) C Refrigerant piping (gas) D Control box E Drain pipe F Air outlet 3 7 7.2 7.3 [Fig. 7.3.1] [Fig. 7.3.2] a d c b e f 90 d c b a b a [Fig. 7.2.1] a Copper tubes b Good [Fig. 7.2.2] [Fig. 7.2.3] a Flare nut b Copper tube e Uneven f Burred c No good d Tilted a Burr b Copper tube/pipe c Spare reamer d Pipe cutter a b e b c d c A c b a d e f g h i [Fig. 7.2.4] [Fig. 7.2.5] a Smooth all around b Inside is shining without any scratches c Even length all around g Cracked h Uneven i Bad examples d Too much e Tilted f Scratch on flared plane a Flaring tool b Die c Copper tube d Flare nut e Yoke A B C D F G E H H K L J I J O O N N 20 20 20 20 A Pipe cover (small) (accessory) B Caution: Pull out the thermal insulation on the refrigerant piping at the site, insert the flare nut to flare the end, and replace the insulation in its original position. Take care to ensure that condensation does not form on exposed copper piping. C Liquid end of refrigerant piping D Gas end of refrigerant piping E Site refrigerant piping F Main body G Pipe cover (large) (accessory) H Thermal insulation (field supply) I Pull J Flare nut K Return to original position L Ensure that there is no gap here M Plate on main body N Band (accessory) O Ensure that there is no gap here. Place join upwards.
Mitsubishi Electric PEA-RP200 WJA Installation manual Main Page Preview

Installation manual [PDF] (22 pages)

  • Brand: Mitsubishi Electric
  • Model: PEA-RP200 WJA
  • Format: PDF
  • Key Aspects: Control Panel and Interface Navigation, Component Longevity Optimization, Warranty and Service Information
  • Updated: 30.04.2026
  • Source File: 1106102.pdf
  • Pages: 22
  • Description: Comprehensive user handbook for the Mitsubishi Electric PEA-RP200 WJA.

Document Preview & Text Transcription

Air-Conditioners INDOOR UNIT PEA-RP200, 250, 400, 500 GAQ FOR INSTALLER FÜR INSTALLATEURE POUR L’INSTALLATEUR PARA EL INSTALADOR PER L’INSTALLATORE VOOR DE INSTALLATEUR FÖR INSTALLATÖREN TIL MONTØREN PARA O INSTALADOR °π∞ ∆√¡ ∆∂áπ∫√ ∂°∫∞∆∞™∆∞™∏™ TES‹SATÇININ D‹KKAT‹NE ДЛЯ СПЕЦИАЛИСТА ПО МОНТАЖУ GB INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen. MANUEL D’INSTALLATION Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte. MANUAL DE INSTALACIÓN Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado. MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d’aria. INSTALLATIEHANDLEIDING Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert. INSTALLATIONSMANUAL Läs denna installationsmanual noga för säkert och korrekt bruk innan luftkonditioneringen installeras. INSTALLATIONSMANUAL Læs venligst denne installationsmanual grundigt, før De installerer airconditionanlægget, af hensyn til sikker og korrekt anvendelse. MANUAL DE INSTALAÇÃO Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado. E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™ °È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘ ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡. MONTAJ ELK‹TABI Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu elkitab›n› dikkatle okuyunuz. РУКОВОДСТВО ПО УСТАНОВКЕ Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по установке до выполнения установки кондиционера. DK SW NL I E F D RU TR GR P 2 GB D F SW I NL E P [Fig. 2.0.1] 1 Pipe cover (For field piping connection) 2 3 1 When connecting air inlet 2 When installing the suspension fixtures prior to installation of the indoor unit without inlet duct 3 When hanging the indoor unit directly without inlet duct A Service space B Air inlet C Air outlet D Suspension bolt pitch E Top of the unit F Suspension bolt holes PEA-200, 250 : 4-ø12 holes PEA-400, 500 : 4-ø15 holes G Control box H Drain pan I Main body [Fig. 3.2.1] [Fig. 3.2.2] F G H A B D C E E 4 4.1 A Ceiling board B Edge beam C Tie beam D Square timber for hanging the air conditioner E Pitch F Insert: 100 to 150 kg (1 piece) (field supply) G Hanging bolt (field supply) PEA-200, 250 : M10 PEA-400, 500 : M12 H Reinforcement [Fig. 4.1.1] [Fig. 4.1.2] 3.2 * In case of PEA-200, 250 * In case of PEA-400, 500 200 530 200 400 730 75 25 C D 500 1 2 3 A A B C B A 200 664 200 400 864 75 25 1095 595 500 1 2 3 A A B C 1800 2400 * In case of PEA-200, 250 * In case of PEA-400, 500 20 B C D D F G H E I A C B 199 200 131 20 764 B C D D F G H E I 1947 1840 203 320 141 C 634 B 1300 1500 Model PEA-200 PEA-250 A 1400 1600 C 900 Model PEA-200 PEA-250 A 1860 2060 B 1260 1460 D 400 3 GB D F SW I NL E P 6.2 5 5.1 A 30 B A B A *1 A 30 B 10 A A B [Fig. 5.1.1] [Fig. 5.1.2] [Fig. 5.1.3] A Unit body B Lifting machine A Nut B Washer A Be sure to attach a U-shaped washer (4 washers in total). A 6 A Refrigerant pipe (liquid pipe) B Refrigerant pipe (gas pipe) C Drain pipe [Fig. 5.2.1] [Fig. 6.2.1] A Level check C E 100 B A D C B A 117 45 100 52 156 117 81 102 C A A B B * In case of PEA-200, 250 * In case of PEA-400, 500 7 7.1 [Fig. 7.1.1] [Fig. 7.1.2] A Thermal insulation B Pull out insulation C Wrap with damp cloth D Return to original position E Ensure that there is no gap here F Wrap with insulating tape G Pipe cover (Accessory part) A Brazing B Gas pipe C Liquid pipe D Indoor unit E Outdoor unit * Refore to the Outdoor Installation Manual for connecting to the outdoor unit. [Fig.7.1.3] A A Remove the cap * In case of PEA-200, 250 * In case of PEA-400, 500 A A G E C F B D A A B E E C A C B D (No.2) (No.1) A A B E C D 5.2 C 89 A 144 B 145 D 52 E 42 Model PEA-200, 250