Omega Engineering 0707 Manuals

1 pdf manual(s) Omega Engineering 0707 for free download (Document Types: Specification sheet)

Omega Engineering 0707 Specification sheet Thumbnail

Omega Engineering 0707 Specification sheet [PDF] (3 pages)

  • Identifier: id-599948
  • Brand: Omega Engineering
  • Device: Omega Engineering 0707 Thermometer
  • Type: Specification sheet, PDF
  • Key Aspects: Hardware Setup Instructions, System Connectivity and Wiring Basics, FAQ Section for Common Queries
  • UPD Date: 15.03.2026
  • Source File: 593014.pdf
  • Pages: 3
  • Description: Service manual for the Omega Engineering 0707.
Pages Preview:
  • Omega Engineering 0707 Specification sheet preview - page 2
  • Omega Engineering 0707 Specification sheet preview - page 3
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 2 HH806U/HH806AU MULTILOGGER THERMOMETER OMEGAnet® On-Line Service omega.com Internet e-mail [email protected] Servicing North America: U.S.A: One Omega Drive, Box 4047 Stamford, CT 06907-0047 ISO 9001 Tel: (203) 359-1660 FAX: (203) 359-7700 Certified e-mail: [email protected] Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: [email protected] For immediate technical or application assistance: U.S.A Sales Service: 1-800-826-6342/1-800-TC-OMEGA® and Customer Service: 1-800-622-2378/1-800-622-BEST® Canada: Engineering Service: 1-800-872-9436/1-800-USA-WHEN® TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico: En Espanol: (001) 203-359-7803 e-mail: [email protected] FAX: (001) 203-359-7807 [email protected] Servicing Europe: Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: [email protected] Czech Frystatska 184, 733 01 Karviná, Czech Republic Republic: Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: [email protected] France: 11, rue Jacques Cartier, 78280 Guyancourt, France Tel: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427 Toll Free in France: 0800 466 342 e-mail: [email protected] Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Austria: Tel: + 49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: [email protected] United One Omega Drive, River Bend Technology Centre Kingdom: Northbank, Irlam, Manchester ISO 9002 M44 5BD United Kingdom Certified Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: [email protected] It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications. INTRODUCTION The instrument is a portable digital thermometer that measures external thermocouples of type K, J, R, S, T, E, N. The thermocouples types comply with the N.I.S.T. – ITS 90 standard reference temperature/voltage tables. The thermometer features a dual thermocouple input, an adjustable T/C offset and an USB interface for uploading data to a PC using optional software and cable. SAFETY INFORMATION WARNING To avoid electrical shock, do not use this instrument when working voltages at the measurement surface over 24V AC or DC. WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. CAUTION Repeated sharp flexing can break the thermocouple leads. To prolong lead life, avoid sharp bends in the leads, especially near the connector. SPECIFICATIONS ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable Measurement Range: K-TYPE (0.1°) -200°C to 1372°C (-328°F to 2501°F) J-TYPE (0.1°) -210°C to 1200°C ( -346°F to 2192°F) T-TYPE (0.1°) -200°C to 400°C (-328°F to 752°F) E-TYPE (0.1°) -210°C to 1000°C (-346°F to 1832°F) R-TYPE (1°) 0°C to 1767°C (32°F to 3212°F) S-TYPE (1°) 0°C to 1767°C ( 32°F to 3212°F) N-TYPE (0.1°) -50°C to 1300°C ( -58°F to 2372°F) *Based on the ITS-90 temperature standard. According to temperature standard ITS-90. Accuracy: K/J/T/E-TYPE ±(0.05% rdg + 0.3°C) on -50°C to 1372°C ±(0.05% rdg + 0.7°C) on -50°C to -210°C ±(0.05% rdg + 0.6°F) on -58°F to 2501°F ±(0.05% rdg + 1.4°F) on -58°F to -346°F N-TYPE ±(0.05% rdg + 0.8°C) on -50°C to 0°C ±(0.05% rdg + 0.4°C) on 0°C to 1300°C ±(0.05% rdg + 1.6°F) on -58°F to 32°F ±(0.05% rdg + 0.8°F) on 32°F to 2372°F R/S-TYPE ±(0.05% rdg + 2°C) on 0°C to 1767°C ±(0.05% rdg + 4°F) on 32°F to 3212°F Temperature Coefficient: 0.1 times the applicable accuracy specification per °C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to122°F). Input Protection: 24V dc or 24V ac rms maximum input voltage on any combination of input pins. Reading Rate: 2.5 time per second. ENVIRONMENTAL Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H. Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H. GENERAL Display: There are three display areas on the HH806 series LCD (liquid crystal display). The Main and Second display are 4 ½ digits with a maximum reading of 19999. These are used for displaying the value of T1 or T2. The Third display is for the date, time, or the differential value o T1 to T2. Overload: “----.-” or “OL” is display. Battery: 1.5V x 4 PCS (SIZE AAA) UM-4 R03. Battery Life: 120 hours typical with carbon zinc battery. Dimensions: 160mm(H) x 83mm(W) x 38mm(D). Weight: Approx. 365g including batteries. Supplied Thermocouple: 1 meter (40”) type K insulated beaded wire thermocouple Maximum insulation temperature is 482°C (900°F) Thermocouple accuracy is ±1.1°C or 0.4% of reading (whichever is greater) from 0°C to 1250°C. Wire Communication Protocol: 2400 baud rate. (HH806U) 19200 baud rate. (HH806A) External Connections: 1. USB Port 2. DC power JACK(12V) M4502/0707 Shop online at: omega.com e-mail: [email protected] For latest product manuals: omegamanual.info INSTRUCTION SHEET

Similar Manuals in the Thermometer Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
optris LT

optris LT User Guide (Operator's manual), @75DW81

59 805 202 31-07-2026 view all manuals
La Crosse Technology 308-1410GRv2

La Crosse Technology Thermometer Manual  (File: PDF, 12-05-2026)

6 720 130 12-05-2026 view all manuals
Traceable PLATINUM

Traceable PLATINUM Manual (Instructions), @9OUE53

2 564 130 15-06-2026 view all manuals
ETI SAF-T-LOG

ETI Thermometer Quick start manual (File: PDF, 15-08-2026)

2 105 25 15-08-2026 view all manuals
Omega Engineering PRTXB Series

Omega Engineering PRTXB Series User Guide (Operation & user’s manual), @AY6WUU

4 426 73 29-05-2026 view all manuals
Eurochron ETH 5200

Guide: Eurochron ETH 5200 (65D497, Upd.10-05-2026)

4 805 194 10-05-2026 view all manuals