RootWave Pro User Guide
U-UGD-PRO-001-3-D 14 Apr 2021
RootWave Pro
Model Nos. covered: PRO-001-3, PRO-002-3, TRA-001-3, TRA-002-3,
APL-001-3, ETD-001-3, ETD-002-3, ETD-003-3, ETD-004-3, ETD-005-3,
GRW-001-3, GRW-002-3, CAB-001-3 and CAB-002-3
User Guide
English
Original instructions
Read and follow all instructions and safety precautions in
this User Guide. Failure to do so will invalidate the
warranty and may cause death or serious injury.
Keep this User Guide for reference - do not throw it away.
2
RootWave Pro User Guide
Copyright
Copyright © 2021 Ubiqutek Limited All Rights Reserved.
Contains information owned by RootWave and/or its affiliates. Do
not copy, store, transmit or disclose to any third party without prior
written permission from RootWave.
RootWave™ is a brand of Ubiqutek™. Ubiqutek Ltd is registered in
England and Wales. Company 08148525.
Intended use
This document provides important safety information and
instructions for using RootWave Pro.
RootWave Pro can be used to treat invasive weeds such as Japanese
Knotweed, Giant Hogweed, Himalayan Balsam and Ragwort.
RootWave Pro suppresses the growth of weeds by applying heat to
the cells, causing lysis.
Compliance
RootWave Pro complies with applicable EU directives:
Low Voltage Directive (2014/35/EU)
Electromagnetic Compatibility Directive (2014/30/EU)
Restriction of Hazardous Substances in Electrical and Electronic
Equipment (RoHS) Directive 2011/65/EU
WEEE Directive 2012/19/EU
3
RootWave Pro User Guide
Rootwave Pro complies with applicable UK regulations:
The Electrical Equipment (Safety) Regulations 2016
The Electromagnetic Compatibility Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in
Electrical and Electronic Equipment Regulations 2012
The Waste Electrical and Electronic Equipment Regulations 2013
Product improvements
RootWave’s philosophy is to continually improve its products. As a
result, improvements are made from time. This user guide will be
updated for significant improvements or any that affect safety.
However, a user guide update may not always follow minor
improvements that do not affect safety. If you are unsure of
anything please contact your RootWave Pro supplier.
Contact details
United Kingdom
RootWave
8 Brook Business Park, Brookhampton Lane, Kineton, Warwickshire
CV35 0JA
www.rootwave.com
Telephone: +44 1926 800789
Email:
[email protected]
Other countries
For other countries contact your RootWave supplier. Contact details
can be found on your sales documentation.
4
RootWave Pro User Guide
Contents
Copyright ............................................................................................. 2
Intended use ....................................................................................... 2
Compliance .......................................................................................... 2
Product improvements ....................................................................... 3
Contact details .................................................................................... 3
Contents .............................................................................................. 4
Figures ................................................................................................. 5
Tables .................................................................................................. 6
Safety information .............................................................................. 7
Warning .......................................................................................... 9
Caution .......................................................................................... 20
Overview of RootWave Pro ............................................................... 22
About RootWave Pro .................................................................... 22
Components ...................................................................................... 25
Getting started .................................................................................. 34
Setting up the Treatment Lance ................................................... 34
Additional equipment ................................................................... 35
Operation .......................................................................................... 38
Loading and transporting equipment ........................................... 38
Before setting out ......................................................................... 39
Safety features .................................................................................. 39
Live electrode warning light ......................................................... 39
Safe Stop on Treatment Lance ..................................................... 40
Emergency stop on Power Module .............................................. 41
Shrouded Electrode Module ......................................................... 41
Using RootWave Pro ..................................................................... 43
Transportation and storage .............................................................. 63
Training .............................................................................................. 63
Changing the fuse.............................................................................. 63
Accessories and replacement parts .................................................. 64
Troubleshooting ................................................................................ 65
RootWave Pro does not activate .................................................. 65
Treatment effect seems inadequate ............................................ 69
The generator stops working or won’t start ................................ 70