Simplex 4100-6062 Manuals

1 pdf manual(s) Simplex 4100-6062 for free download (Document Types: Installation and programming instructions)

Simplex 4100-6062 Installation and programming instructions Thumbnail

Simplex 4100-6062 Installation and programming instructions [PDF] (22 pages)

  • Identifier: id-2371069
  • Brand: Simplex
  • Device: Simplex 4100-6062 Recording Equipment
  • Type: Installation and programming instructions, PDF
  • Key Aspects: Technical Support and Resource Links, Environmental Factors and Restrictions, Step-by-Step Assembly Procedures
  • UPD Date: 29.05.2026
  • Source File: 2433723.pdf
  • Pages: 22
  • Description: Complete technical documentation for the Simplex 4100-6062.
Pages Preview:
  • Simplex 4100-6062 Installation and programming instructions preview - page 2
  • Simplex 4100-6062 Installation and programming instructions preview - page 3
  • Simplex 4100-6062 Installation and programming instructions preview - page 4
  • Simplex 4100-6062 Installation and programming instructions preview - page 5
  • Simplex 4100-6062 Installation and programming instructions preview - page 6
  • Simplex 4100-6062 Installation and programming instructions preview - page 7
  • Simplex 4100-6062 Installation and programming instructions preview - page 8
  • Simplex 4100-6062 Installation and programming instructions preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
© 2004. 2011 SimplexGrinnell LP. All rights reserved. Specifications and other information shown were current as of publication and are subject to change without notice. Tyco Safety Products, Simplex and the Simplex logo AUTOCALL, TFXnet, and CONSYS are trademarksare trademarks of Tyco International Ltd. and its affiliates and are used under license. 4100-6062 TFXi Installation and Programming Instructions Overview The 4100-6062 TFX Interface (hereafter referred to as the TFXi) provides the following functionality: • It allows a 4100U or a 4100ES Fire Alarm Control Panel (FACP) to transmit specific events (Fire, Trouble, Supervi- sory, Signal Silence, System Reset, Control, Utility, etc.) over the TFXnet to TFX fire panels and annunciators. • It monitors the state of specific TFX points, and turns on the FACP pseudo points when the state of the TFX point changes. These pseudo points can be associated with spe- cific system actions (for example perform a system reset on the FACP), or they can be utility pseudo points linked to Custom Control equations that perform facility-specific actions (for example, turn on relays). The TFXi consists of a 2” x 11.5” motherboard, which mounts to the chassis of an FACP, and a daughter card, containing an RS- 232 connector and TFXi firmware, that mounts in a socket on the motherboard. Battery current requirements for the 4100-6062 TFX Interface Module are as follows: • Supervisory Current = 132 mA • Alarm Current = 132 mA In this Document Related Documentation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 Replacing 4100U/4100ES Single Page Operating Instructions- - 2 Setting Jumpers and Switches - - - - - - - - - - - - - - - - - - - - - - - - 2 Installing TFXi Card in an FACP Bay - - - - - - - - - - - - - - - - - - - - 3 Wiring TFXi to TLT-530 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 TLT-530 Configuration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 IDC Monitoring Operation- - - - - - - - - - - - - - - - - - - - - - - - - - - - 8 Adding TFXi Card to Job - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8 Network Option Tab Settings- - - - - - - - - - - - - - - - - - - - - - - - - - 8 Subnet Tab Settings- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8 Zones Tab Settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 Points Tab Settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 Application Programming Overview- - - - - - - - - - - - - - - - - - - - 10 Programming Peer-to-Peer Operation - - - - - - - - - - - - - - - - - - 11 Programming TFX Master-to-4100U/4100ES Slave Operation- 14 Programming 4100U/4100ES Master-to-TFX Slave Operation- 15 Appendix A. Example Programming Screen- - - - - - - - - - - - - - 16 Appendix B. TFX Predefined System Points- - - - - - - - - - - - - - 17 Appendix C. 4100U/4100ES Card Status Troubles - - - - - - - - - 18 ���� �������������������� ����������� ������ ��������������� ���������� ������� ������� ������ ��� ����� ������������������ ��������������� ���� ����� ���� ����� ���� Figure 1 TFXi Functional Overview (4100U Shown) 579-575 Rev. E firealarmresources.com

Similar Manuals in the Recording Equipment Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
OHAUS Ranger Count 3000 Series

User Manual: OHAUS Ranger Count 3000 Series (BF8F52, Upd.05-04-2026)

33 1131 227 05-04-2026 view all manuals
SMA CLUSTER CONTROLLER

Guide: SMA CLUSTER CONTROLLER (YUTOHJ, Upd.02-07-2026)

84 290 53 02-07-2026 view all manuals
Yamaha RM1x

Yamaha RM1x Manual (Owner's manual), @IG5HI2

154 3.29 Mb 644 97 30-08-2026 view all manuals
WEG CFW500 Series

WEG Control Unit Safety manual (File: PDF, 19-08-2026)

81 1014 203 19-08-2026 view all manuals
Eagle Eye PV912

#3T5VUH: PV912 Recording Equipment Operation & user’s manual

43 250 40 24-06-2026 view all manuals
Avolites Pearl Expert Titan

#12JGP2: Pearl Expert Titan Recording Equipment Operator's manual

260 733 110 29-08-2026 view all manuals