Southwire 10020N Manuals

1 pdf manual(s) Southwire 10020N for free download (Document Types: Operating instructions manual)

Document Preview & Text Transcription

12/14 Rev. 1 10020N manual Contents Made in China Product distributed by Southwire Company, LLC One Southwire Drive, Carrollton, GA 30119 ©2014 Southwire Company, LLC. All rights reserved. southwiretools.com 1-855-SW-T00LS Toll Free Technical Help Línea de Ayuda Técnica Gratuita Scan for warranty information and to access our mobile site. Escanea para información de garantía y acceso a nuestro sitio móvil. Operating Instructions 10020N 3in1 MULTIMETER Hz% MODE ® TESTING EQUIPMENT E361819 Instrucciones de Operación MULTÍMETRO 10020N 3en 1 Introduction WARNINGS 1 The Southwire 10020N measures AC/DC voltage and current, resistance, frequency, and duty cycle. Other functions include non-contact AC voltage detection, continuity and diode test. �������������������������������������������������� This meter is fully tested and calibrated and, with proper use, will provide many years of reliable service. ���������������������������������������������������������������� Instructions in this manual before using this meter. ��������������������������������������������������������������� ���������������������������������������������������������� ����������������������������������������������������������� measurements. ������������������������������������������������������������� always disconnect the test leads from the circuit under test. ����������������������������������������������������� ��������������������������������������������������������� ������������������������������������������������������������� ���������������������������������������������������������� ���������������������������������������������� �����������������������������������������������������damaged. ��������������������������������������������������������������� electrical storms. ����������������������������������������������������������� �������������������������������������������������� Protection may be compromised. ������������������������������������������������������������ ��������������������������� 2 Input Limits Function Maximum Input Voltage AC, Voltage DC Frequency, Duty Cycle Amperage µA, mA AC/DC Resistance, Diode & Continuity Test 600V AC/DC 600V AC/DC Maximum Amperage 200mA, Maximum Voltage 500V 250V AC/DC ��������������������� Max input voltage Diode Test Continuity Check Display Over range indication Polarity Low Battery Indication Input Impedance AC Response ACV Bandwidth Auto Power Off Fuse Batteries Operating Temperature Storage Temperature Operating Altitude Size/Weight Safety 600V AC/DC Test current 1mA max., open circuit voltage of 1.5V typical Audible signal if the resistance is <30Ω, sound off at >150Ω 4000 count 3 -3/4 digit LCD LCD displays “OL” Minus (-) sign for negative polarity “ ” symbol indicates low battery condition >7.5MΩ (VDC & VAC) Average responding 45 to 450Hz 15 minutes (approximately) mA, µA ranges; 0.2A/500V fast acting Resettable Fuse Two 1.5V AAA 41oF to 104oF (5oC to 40oC) 14oF to 140oF (-10oC to 60oC) 7000ft. (2000meters) maximum 4” x 2.165”x 1.28”/0.32 lb. (104x55x32.5mm/145g) UL61010-1 CAT IV-600V Pollution Degree 2, CE Approved 3 Potential danger. Indicates the user must refer to the manual for important safety information Indicates hazardous voltages may be present Equipment is protected by double or reinforced insulation Indicates the terminal(s) so marked must not be connected to a circuit where the voltage with respect to earth ground exceeds the maximum safety rating of the meter Indicates the terminal(s) so marked may be subjected to hazardous voltages. MAX 600 V International Safety Symbols Brief Description Typical Applications Category Rating Single phase receptacles and connected loads Three phase circuits and single phase lighting circuits in commercial buildings - Household appliances, power tools - Outlets more than 30ft (10m) from a CAT III source - Outlets more than 60ft (20m) from a CAT IV source - Equipment in fixed installations such as 3-phase motors, switchgear and distribution panels - Lighting circuits in commercial buildings - Feeder lines in industrial plants - Any device or branch circuit that is close to a CAT III source CAT II CAT III The measurement category (CAT) rating and voltage rating is determined by a combination of the meter, test probes and any accessories connected to the meter and test probes. The combination rating is the LOWEST of any individual component. CAT IV Connection point to utility power and outdoor conductors - Primary distribution panels - Overhead or underground lines to detached buildings - Incoming service entrance from utility - Outdoor pumps WARNING: Operation is limited to CAT II applications when the insulated tips are removed from one or both test probes. Refer to Input Limits section of this manual for maximum voltage ratings. CAT III 1000V CAT IV 600V CAT II 1000V Insulated Tip On Insulated Tip Removed 4 Hz% MODE ® Maintenance This Multimeter is designed to provide years of dependable service, if the following care instructions are performed: 1. KEEP THE METER DRY. If it gets wet, wipe it off. 2. USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts. 3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the electronic parts or the case. 4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents, or detergents. 5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE. Remove old or weak batteries so they do not leak and damage the unit. 6. IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME, the batteries should be removed to prevent damage to the unit. Meter Description 1. Non-contact AC voltage detector probe tip 2. Non-contact AC voltage indicator light 3. LCD display 4. MODE button 5. Rotary function switch 6. Flashlight 7. Flashlight button 8. Hz/% Duty Cycle button 9. Battery Cover 10. Test leads 1. 2. 9. 10. 3. 7. 6. 8. 4. 5.