Supco CPH100 Manuals
1 pdf manual(s) Supco CPH100 for free download (Document Types: Operating instructions)
Supco CPH100 Operating instructions [PDF] (3 pages)
- Identifier: id-872652
- Brand: Supco
- Device: Supco CPH100 Test Equipment
- Type: Operating instructions, PDF
- Key Aspects: Periodic Inspection Checklists, Step-by-Step Assembly Procedures, Environmental Factors and Restrictions
- UPD Date: 27.07.2026
- Source File: 871909.pdf
- Pages: 3
- Description: User instruction booklet for the Supco CPH100.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Specifications Function Range & Resolution Accuracy (% of reading) 400.0A DC Current 4000A ± (1.8% + 3 digits) 400.0A 4000A ± (2.0% + 5 digits) 4.000 AAC 40.00 AAC ± (2.5% + 10 digits) AC Current 400.0 AAC ± (2.0 % + 5 digits) 400.0 mVDC ± (0.8% + 3 digits) 4.000 VDC 40.00 VDC 400.0 VDC ± (1.5% + 3 digits) DC Voltage 600 VDC ± (2.0% + 3 digits) 400.0 mVAC ± (0.8% + 10 digits) 4.000 VAC 40.00 VAC 400.0 VAC ± (2.0% + 5 digits) AC Voltage 600 VAC ± (2.0% + 5 digits) 400.0 Ω ± (1.0% + 4 digits) 4.000KΩ 40.00KΩ 400.0KΩ ± (1.5% + 2 digits) 4.000MΩ ± (2.5% + 3 digits) Resistance 40.00MΩ ± (3.5% + 5 digits) 40.00nF (5.0% reading + 10 digits) 400.0nF (3.0% reading + 5 digits) 4.000μF 40.00μF (3.5% reading + 5 digits) Capacitance 100.0μF (5.0% reading + 5 digits) 5.000Hz (1.5% reading + 5 digits) 50.00Hz 500.0Hz 5.000kHz 50.00kHz Frequency 150.0kHz (1.2% reading + 2 digits) Sensitivity: 5~5kHz:10Vrms min. 5kHz~150kHz:40Vrms min. @ 20% to 80% duty cycle 0.5 to 99.0% (1.2% reading + 2 digits) Duty Cycle Pulse width: 100µs - 100ms, Frequency: 5Hz to 150kHz Sensitivity: 5~5kHz:10Vrms min.5kHz~150kHz:40Vrms min. @ 20% to 80% duty cycle -50.0 to -20. 0C 7C -50.0 to 400.0C -20.0 to 400.0C 400 to 1000C (3.0% reading + 3 C) 400 to 1300 C 1000 to1300C (3.0% reading + 5C) -50.0 to 0F 14F -58.0 to 400.0F 0 to 400.0F 400 to 1000F (3.0% reading + 7F) Temp (type-K) (probe accuracy not included) 400 to 2372 F 1000 to1300F (3.0% reading + 10F) Input limits Function Maximum Input A AC 400A mA DC, mA AC 200mA 250V fast acting fuse V DC,V AC,Frequency,Duty Cycle 600V DC/AC Resistance,Diode,Continuity, 250V DC/AC Capacitance,Test Temperature (°C/°F) 60V DC/24V AC Safety International Safety Symbols This symbol, adjacent to another symbol or terminal,indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present. Double insulation SAFETY NOTES · Do not exceed the maximum allowable input range of any function · Do not apply voltage to meter when resistance function is selected. · Set the function switch OFF when the meter is not in use. WARNINGS · The dial must be set to the OFF position when installing the batteries, or there will be no display until the dial is returned to OFF to reset the meter. · Set function switch to the appropriate position before measuring. · When measuring volts do not switch to current/resistance modes. · Do not measure current on a circuit whose voltage exceeds 240V. · When changing ranges using the selector switch always disconnect the test leads from the circuit under test. · Do not exceed the maximum rated input limits. CAUTIONS Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. Always remove the test leads before replacing the battery. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. Remove the battery if the meter is to be stored for long periods. Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests. · Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not “live”. · If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. un 1. AC DC AC (alternating current) and DC (direct currrent) 2. Minus sign 3. 3. 3. 3. 3. 8.8.8.8 8.8.8.8 8.8.8.8 8.8.8.8 8.8.8.8 4000 count (0 to 3999) measurement reading 4. AUTO AutoRange mode 5. ZERO ZERO mode 6. Diode test mode 7. •))) Audible Continuity 8. HOLD Data Hold mode 9. ,m,V,A,K,M, , Units of measure list Meter Description 1. Current clamp 2. Clamp trigger 3. Rotary Function swith 4. LCD display 5. ZERO button 9. Hz/%duty button 10. COM input jack 11.V CF jack 12. Battery Cover OPERATING INSTRUCTIONS CPH100 HVAC CURRENT PROBE SEALED UNIT PARTS CO., INC. P.O. Box 21, 2230 Landmark Place, Allenwood, N.J. 08720 USA (732)223-6644 • Fax (732)223-1617 www.supco.com • [email protected]
Similar Manuals in the Test Equipment Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
WHALETEQ DFS360 |
Test Equipment #7U7Y56 |
34 | 840 | 152 | 17-04-2026 | view all manuals | |
M&C PSS Series |
PSS Series (Industrial Equipment ePDF User Guide, #B2SG21) |
33 | 268 | 65 | 29-05-2026 | view all manuals | |
Pro'sKit 8PK-4103IN |
PDF User Guide (@89X531), Pro'sKit 8PK-4103IN Test Equipment (12-06-2026) |
22 | 1140 | 228 | 12-06-2026 | view all manuals | |
Hydrajaws 2008 |
2008 (Test Equipment ePDF Guide, #362N1W) |
9 | 852 | 188 | 02-06-2026 | view all manuals | |
JDS Uniphase CT-650 |
CT-650 (Test Equipment ePDF Guide, #J6822M) |
248 | 674 | 142 | 26-05-2026 | view all manuals | |
Chauvin Arnoux C.A 6422 |
C.A 6422 Operation & user’s manual - 3M4J9C |
28 | 133 | 23 | 13-08-2026 | view all manuals |