Sound Level Calibrator
HB2TM1000001
� Setting standard sound levels at 94dB and
114dB.
� 1/2” microphone adapters provided.
� With low battery indictor.
� Standard:
ANSI
S1.40-1984
and
IEC942 1988 Class2.
� Output Sound Level: 94dB and 114dB
re 20 uPa under reference.
� Output Frequency: 1kHz ±4%.
� Accuracy: ±0.5dB.
� Battery: 9V, 006P or IEC 6F22 or
NEDA 1604.
� Low
Battery
Indicator:
The
LED
indicator will off, if battery voltage low.
� Battery
Life:
Approx
20
hours.
(Alkaline battery)
� Dimension:
48mm x 125mm
� Weight: 285g
� Operation Temperature and Humidity:
0~40℃ (32~104℉), 10~70% RH.
� Storage Temperature and Humidity:
-10~60℃ (14~140℉), 10~90% RH.
� Test Condition
a. Environment Temperature: 20℃.
b. Relative Humidity: 65%.
c. Atmospheric
Pressure:
1013
mbar.
(1) Power and output level select switch.
(2) Cavity of Sound-Level Calibrator.
(3) Battery cover.
(4) Low battery indicator.
(5) The 1/2” adapter.
I. Feature
II. Specification
III. Instrumentation
(1) Open the battery cover, and insert the
battery in position.
(2) Choosing a suitable adapter and plug
into the Sound-Level Calibrator.
(3) With suitable plug of microphone, and
plug into the adapter all the way down
of the Sound-Level Calibrator.
(4) Turn on power switch and set sound
level to 94dB or 114dB Position.
(5) Read the level on the microphone
instrument under test and adjust the
sensitivity control for the correct
indication
of
the
Sound-Level
Calibrator level selected in step.
IV. Test Procedure
(1) Use the Sound-Level Calibrator as
specified in this manual; otherwise, the
protection provided by this meter may
be impaired.
(2) When using Sound-Level Calibrator,
environment noise level should less
then 10dB of output sound.
(3) Environment conditions
a. Altitude up to 2000 meters.
b. Relative humidity up to 90%.
c. Operation
ambient
0~40
℃
(32~104℉).
(4) Replace
the
battery
for
keep
measuring correctly, if LED indicator
light off.
(5) If long time not in use, we recommend
to take out the battery to decrease the
battery leaking which could damage
the Sound-Level Calibrator.
V. Notice