United Automation Infresco-S 4kW Manuals
2 pdf manual(s) United Automation Infresco-S 4kW for free download (Document Types: User & installation manual, Operation & user’s manual)
United Automation Infresco-S 4kW User & installation manual [PDF] (2 pages)
- Identifier: id-1648444
- Brand: United Automation
- Device: Infresco-S 4kW Control Unit
- Type: PDF
- Key Aspects: Information on Regular Maintenance, Hardware Setup Instructions, Performance Optimization Tips
- UPD Date: 10.03.2026
- Source File: 1670285.pdf
- Pages: 2
- Description: Official operating instructions for the United Automation Infresco-S 4kW.
Click to expand and read text
Introduction The Infresco-S 4kW is part of a family of controllers designed to provide energy saving when used with Quartz Infrared Halogen Lamps or other Heating and Lighting Products. The ‘S’ model switches Soft Starts the load each time power is applied The microcontroller-based unit incorporates zero-voltage switching and a soft-start function to eliminate the lamps’ initial high inrush current – potentially increasing lamp life by as much as 30%. Installation of the unit is simple and once installed is relatively maintenance-free. Product Features Extends Lamp Life. Soft-start/zero-voltage switch-off. Low-cost. Easy to install. Applications: patio areas, smoking shelters, restaurants, warehouses, workshops and garden lighting. Installation Important: Read carefully the following information before installing the unit. The Infresco-S 4kW should be fixed securely using the four mounting holes accessible from the front of the unit. Remove the lid to access the mounting holes. To ease installation, a mounting template is provided on the next page to locate the 4 mounting hole centres. IMPORTANT! The unit must be orientated with the cable glands facing down. Wiring It is recommended that installation and maintenance of this equipment should be done with reference to the current edition of the I.E.E. wiring regulations (BS7671) by suitably qualified/trained personnel. These regulations contain important requirements regarding safety of electrical equipment (for International Standards refer to I.E.C/ directive IEC950). Warning! Ensure all earth wires are connected to maintain earth continuity to the lamp fittings. Isolate the mains supply before wiring this unit. The unit is fitted with two cable glands. Only one cable should be fitted per gland to maintain the unit’s IP rating. When fitting two lamps, refer to Wiring Diagram for an alternative wiring configuration using a junction box. The mains supply connects to the terminal block marked ‘LINE’. Connect the supply LIVE to the ‘L’ terminal, NEUTRAL to the ‘N’ terminal and EARTH to the ‘E’ terminal. The lamps connect to the terminal block marked ‘LOAD’. Connect the load LIVE to the ‘L’ terminal, NEUTRAL to the ‘N’ terminal and EARTH to the ‘E’ terminal. If two lamps are to be fitted they must be wired in parallel. Check all wiring - particularly the line and load connections and make sure the cable glands are tightened. Mounting Template Commissioning Set the on-time preset (VR1) to a time period of between 1 and 40 minutes. VR1 is located at the top of the printed circuit board as shown above. Replace the lid and switch on the mains supply to the unit. Press the push-button on the front of the unit to switch the lamps on. Technical Specification Supply Voltage 230VAC +/- 10% 50 Hz Switching Capacity 4kW Max. Current Consumption (control circuit) 50mA Terminals 2.5mm2 Rising Clamp Operating Temperature -20 to 40°C Protection Rating IP65 Gland Diameter Max Cable Entry 2.5mm² Enclosure Dimensions (WxLxH) 100x100x60 (mm) Mounting Template Use this template to locate the 4 mounting hole centres prior to drilling. IMPORTANT! The drilling of any additional holes will immediately void the warranty of this unit. The unit must be orientated with the cable glands facing down.
United Automation Infresco-S 4kW Operation & user’s manual [PDF] (6 pages)
- Identifier: id-2107845
- Brand: United Automation
- Device: Infresco-S 4kW Controller
- Type: PDF
- Key Aspects: Manufacturer Contact and Support Data, Component Longevity Optimization, Advanced Configuration Methods
- UPD Date: 10.06.2026
- Source File: 2179827.pdf
- Pages: 6
- Description: Practical operating guide for the United Automation Infresco-S 4kW.
Click to expand and read text
INFRESCO-S-4kW X20034 Issue: 2 User Manual Date: 12/06/18 Page: 1 of 6 KEY FEATURES • Extends lamp Life. • Ideal for controlling up to 2 x 2kW lamps. • Soft-start/zero-voltage switch-off. • Low-cost. • Easy to install. • Power ON (Blue) & Heater ON (Red) LED indication.
Infresco-S 4kW: Related Instructions
Introduction The Infresco-S 4kW is part of a family of controllers designed to provide energy saving when used with Quartz Infrared Halogen Lamps or other Heati Official user handbook for the United Automation Infresco-S 4kW Control Unit. The documentation guides users through setup and operating conditions, device reset instructions, technical overview.
X20114 INFRESCO P 4kW Issue 2 User manual Date 11/06/18 Page 1 of 9 KEY FEATURES • Energy saving:- o Only provides heat when people are present. • Extends Installation and maintenance guide for the United Automation INFRESCO P Controller. This manual offers stepwise instructions for operational guidelines, usage tips, system checks.
X20012 Soft Start with Bypass Contactor-6kW Issue 1 User Manual Installation and operation manual for the United Automation SSC-6kW Controller. This reference includes supported accessories, repair references, performance details.
INFRESCO-S-4kW X20034 Issue: 2 User Manual Date: 12/06/18 Page: 1 of 6 KEY FEATURES • Extends lamp Life. • Ideal for controlling up to 2 x 2kW lamp Owner’s guide for the United Automation Infresco-S 4kW Controller. The manual outlines technical specifications and operating conditions, backup procedures, supported accessories, cleaning instructions.
X20019 INFRESCO T 4KW Issue 4 User Manual Date 21/01/16 Page 1 of 6 KEY FEATURES • Energy saving – provides heat for a pre- determined time period. � Instructions for safe usage of the United Automation INFRESCO T 4KW Controller. It describes maintenance tasks and safety, functional overview, usage recommendations.
INTRODUCTION SAFETY FIRST Please read these instructions before installing and operating this product. Infresco-T 6kW The Infresco-T 6kW is part of a family of Operation instructions for the United Automation Infresco T 6.0kW Timer. This manual describes setup, usage, and error handling, operating instructions, operation, repair references.
Similar Manuals in the Controller, Control Unit Category
Wireless Alarm Controller User's Manual Product Name: Wireless Alarm Controller Model No: WAC-110 Input Power: AC 120V, 50/60Hz Features Description : 1. Ba Instruction guide for the UIS WAC-110 Controller. The manual provides information on maintenance schedule, technical troubleshooting, device features, reset instructions.
Types 1098-EGR and 1098H-EGR D100339X012 Instruction Manual Form 5084 December 2008 www.emersonprocess.com/regulators Types 1098-EGR and 1098H-EGR Pressure Redu Operation and maintenance manual for the Fisher 1098-EGR Controller. This documentation explains configuration and device overview, installation, installation guides.
Model CH-C1 Machine Code: D135/D136/D137/D138 System Maintenance 2 23 May, 2014 Service manual for the Ricoh MP C6502SP Printer. This documentation provides step-by-step guidance on operational safety, menu navigation, wiring diagrams.
In electro-optical experiments or automated test and measurement systems, configuration of multiple instruments is often required to perform a series of synchro Setup and usage guide for the Newport XPS Series Controller. The manual elaborates on features and network configuration, system setup, hardware components.