1
-
Please follow these safety instructions closely to
2
-
Auxiliary components, spare and wearing parts
3
-
Any usage beyond this must be approved by the man-
8
-
Removing the front panel
11
-
3. Remove the installation kit from the gas pipe.
12
-
Fitting the boiler to the pre-plumbing jig
13
-
Take care not to injure your hands.
14
-
The "System certificate" and "Skoberne GmbH flue
15
-
Opening the control unit enclosure (cont.)
17
-
5 4 3 2 1
18
-
Routing connecting cables/leads
19
-
A Floating contact (when connecting, remove jumper
21
-
Power supply and KM BUS connection of accessories
23
-
Multi boiler system:
27
-
Total heating output
28
-
Fitting the front panel
30
-
6. Activate the venting function with "Yes" or "
31
-
Settings and explanations
32
-
4. Compare the device list with the system compo-
33
-
3. To view a summary of the system configuration,
34
-
1. To change the gas type on the control unit, see
35
-
Supply pressure (flow pressure)
36
-
Burner in operation
37
-
The pump speed and consequently the pump rate are
38
-
Residual head of the integral circulation pump
39
-
Tap the following buttons:
40
-
Escaping flue gas poses a risk to health.
42
-
Check burner gasket A and burner gauze assembly
43
-
A Ignition electrodes
44
-
1. Drain the boiler on the DHW side.
47
-
Escaping gas leads to a risk of explosion.
48
-
Outside temperature in °C
50
-
Boiler water or
51
-
Boiler control unit
52
-
3. Enter the password "viservice".
53
-
■ Parameters are split into the following groups:
54
-
Parameter values in bold are factory settings.
55
-
"LON subscriber number"
56
-
"Interval until the next service"
57
-
"Maximum cylinder temperature"
58
-
"Pump idle time"
60
-
"Maximum flow temperature limit, heating circuit"
61
-
"Time limit for comfort mode"
62
-
"Wireless outside temperature sensor"
65
-
"Function, input DE1 at extension EA1"
66
-
"Display correction for outside temperature"
68
-
"Fault messaging delay"
69
-
"SCOT correction factor, flue length"
70
-
"LON subscriber monitoring"
71
-
"Operating mode, internal circulation pump"
73
-
"Additional function for DHW heating"
75
-
"DHW circulation pump for DHW heating"
77
-
"Controller amplification of speed control"
78
-
"Frost protection function for solar circuit"
79
-
"Minimum collector temperature"
80
-
"Priority for DHW cylinder"
81
-
"Temperature limits, frost protection function"
82
-
With economy function outside tem-
83
-
"Room temperature hook-up"
84
-
"Setting range, set day temperature"
86
-
Screed drying disabled
87
-
"Pump start heating circuit pump A1, standby mode"
88
-
6. Tap "Code" or "
92
-
Neuron chip software version
93
-
Diverter valve set to heating mode
94
-
Regulates as if the outside
96
-
Mixer is being closed.
97
-
Burner in a fault state
98
-
CO limiter sensor fault
100
-
Mixer regulates to 20 °C flow
101
-
3. If the boiler needs to be removed:
109
-
04. Remove the 4 screws from the fitting assembly.
110
-
Checking the temperature sensors
111
-
2. Measure the sensor resistance across "X3.1" and
112
-
Checking the plate heat exchanger
114
-
Checking the temperature limiter
115
-
Checking the fuse
116
-
Check flow temperature sensor
117
-
The following details are required when ordering
118
-
Serial no. 7570778, 7570780, 7570784, 7570786
120
-
Overview of assemblies (cont.)
121
-
Diaphragm grommet DN 60
123
-
Heat cell assemb
124
-
Boiler flue connection
125
-
Burner gasket (wearing part)
127
-
Diaphragm expansion vessel 10 l
129
-
Hydraulic assembly, system boiler
132
-
Air vent valve
133
-
Control unit assembly
136
-
Control unit VBC138-A10.0xx
137
-
Touch-up spray paint, white, 150 ml can
139
-
Internal H1 extension
142
-
Internal H2 extension
143
-
fÖ A Power supply for additional accessories
144
-
Digital input 1
145
-
Temperature profile 4: Parameter F1:4
149
-
Boiler water temperature sensor
154
-
Switching mode power supply
155
-
Settings and test values
156
-
Gas condensing system boiler (type B2HB)
157
-
Rated heating output range (to EN 15502-1)
158
-
Available in the following countries
160
-
Viessmann products can be recycled. Components
161
-
Vitodens 200-W, type B2HB and B2KB
162
-
Hortonwood 30, Telford
168