YOKOGAWA EJX510B Manuals

2 pdf manual(s) YOKOGAWA EJX510B for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

User’s Manual Yokogawa Electric Corporation EJX510B and EJX530B Absolute and Gauge Pressure Transmitters IM 01C27F01-01EN IM 01C27F01-01EN 11th Edition Toc-1 IM 01C27F01-01EN EJX510B and EJX530B Absolute and Gauge Pressure Transmitters IM 01C27F01-01EN 11th Edition 11th Edition: Dec. 2018 (YK) All Rights Reserved, Copyright © 2010, Yokogawa Electric Corporation Contents 1. Introduction................................................................................................ 1-1 1.1 Safe Use of This Product ..................................................................................1-2 1.2 Radio Wave.........................................................................................................1-3 1.3 Warranty..............................................................................................................1-4 1.4 Trademarks.........................................................................................................1-4 1.5 Control of Pollution Caused by the Product...................................................1-5 2. Handling Cautions..................................................................................... 2-1 2.1 Model and Specifications Check......................................................................2-1 2.2 Unpacking...........................................................................................................2-1 2.3 Storage................................................................................................................2-2 2.4 Selecting the Installation Location .................................................................2-2 2.5 Pressure Connection.........................................................................................2-3 2.6 Restrictions on Use of Radio Transceivers....................................................2-3 2.7 Insulation Resistance and Dielectric Strength Test.......................................2-3 2.8 Installation of an Explosion-Protected Instrument........................................2-4 2.8.1 FM Approval........................................................................................2-5 2.8.2 CSA Certification.................................................................................2-6 2.8.3 ATEX Certification...............................................................................2-6 2.8.4 IECEx Certification..............................................................................2-8 2.9 EMC Conformity Standards..............................................................................2-8 2.10 Pressure Equipment Directive (PED) ...................................................2-9 2.11 Low Voltage Directive........................................................................................2-9 2.12 Regulatory Compliance for Radio and Telecommunication.......................2-10 2.12.1 Radio Equipment Directive (RE).......................................................2-10 2.12.2 FCC compliance...............................................................................2-10 2.12.3 Industry Canada (IC) compliance.....................................................2-10 2.13 RoHS.................................................................................................................. 2-11 3. Component Names................................................................................... 3-1 4. Installation.................................................................................................. 4-1 4.1 Precautions ........................................................................................................4-1 4.2 Mounting.............................................................................................................4-1 4.3 Rotating Transmitter Section............................................................................4-2 Toc-2 IM 01C27F01-01EN 4.4 Changing the Direction of Integral Indicator .................................................4-2 4.5 Changing the direction of the antenna............................................................4-3 5. Installing Impulse Piping.......................................................................... 5-1 5.1 Impulse Piping Installation Precautions.........................................................5-1 5.1.1 Connecting Impulse Piping to a Transmitter.......................................5-1 5.1.2 Routing the Impulse Piping.................................................................5-1 5.2 Impulse Piping Connection Examples............................................................5-2 6. Wiring.......................................................................................................... 6-1 6.1 Mounting Antenna and Wiring..........................................................................6-1 6.1.1 Mounting the antenna.........................................................................6-1 6.1.2 Mounting External Antenna and Wiring Antenna Extension Cable....6-2 6.1.2.1 Mounting of External Antenna.............................................................6-2 6.1.2.2 Wiring of Antenna Extension Cable....................................................6-2 6.1.2.3 Mounting of Surge Protective Device and Wiring...............................6-4 6.2 Grounding...........................................................................................................6-4 6.3 Power Supply Wiring Precautions...................................................................6-5 6.4 Selecting the Wiring Materials..........................................................................6-5 6.5 Connection of the External Power Source Terminal......................................6-5 7. Operation.................................................................................................... 7-1 7.1 Preparation for Starting Operation..................................................................7-1 7.2 Zero Point Adjustment......................................................................................7-2 7.3 Starting Operation.............................................................................................7-3 7.4 Connecting to the Field Wireless Network......................................................7-3 7.5 Shutting Down the Transmitter........................................................................7-5 8. Setting Parameters.................................................................................... 8-1 8.1 Environment for parameter setting..................................................................8-1 8.2 Preparing Software............................................................................................8-1 8.2.1 Softwares for the Field Wireless Configuration Tool and the Device Configuration Tool...............................................................................8-1 8.2.2 Software Download.............................................................................8-1 8.3 Setting Parameters............................................................................................8-1 8.3.1 Parameter Usage and Selection.........................................................8-1 8.3.2 Function Block and Menu Tree...........................................................8-2 8.3.3 Parameters for Wireless Communication.........................................8-10 8.3.4 Tag and Device Information..............................................................8-10 8.3.5 Unit.................................................................................................... 8-11 8.3.6 Range Change.................................................................................. 8-11 8.3.7 Output Signal Low Cut Mode Setup................................................. 8-11 8.3.8 Integral Indicator Scale Setup...........................................................8-12 8.3.9 Unit for Displayed Temperature........................................................8-12 8.3.10 Zero Point Adjustment and Span Adjustment...................................8-12

Document Preview & Text Transcription

User’s Manual Yokogawa Electric Corporation EJX510B and EJX530B Absolute and Gauge Pressure Transmitters IM 01C27F01-01EN IM 01C27F01-01EN 2nd Edition i IM 01C27F01-01EN EJX510B and EJX530B Absolute and Gauge Pressure Transmitters IM 01C27F01-01EN 2nd Edition 2nd Edition: Aug. 2010 (YK) All Rights Reserved, Copyright © 2010, Yokogawa Electric Corporation Contents 1. Introduction................................................................................................ 1-1 1.1 Safe Use of This Product ..................................................................................1-2 1.2 Radio Wave.........................................................................................................1-3 1.3 Warranty..............................................................................................................1-3 1.4 Trademarks.........................................................................................................1-3 1.5 ATEX Documentation........................................................................................1-4 2. Handling Cautions..................................................................................... 2-1 2.1 Model and Specifications Check......................................................................2-1 2.2 Unpacking...........................................................................................................2-1 2.3 Storage................................................................................................................2-1 2.4 Selecting the Installation Location .................................................................2-2 2.5 Pressure Connection.........................................................................................2-2 2.6 Restrictions on Use of Radio Transceivers....................................................2-3 2.7 Insulation Resistance and Dielectric Strength Test.......................................2-3 2.8 Installation of an Explosion-Protected Instrument........................................2-4 2.8.1 FM Approval........................................................................................2-4 2.8.2 CSA Certification.................................................................................2-5 2.9 EMC Conformity Standards..............................................................................2-5 2.10 Pressure Equipment Directive (PED) ...................................................2-5 2.11 Low Voltage Directive........................................................................................2-6 2.12 Regulatory Compliance for Radio and Telecommunication.........................2-7 2.12.1 Radio and Telecommunications Terminal Equipment Directive (R&TTE) .....................................................................................................2-7 2.12.2 FCC compliance.................................................................................2-7 2.12.3 Industry Canada (IC) compliance.......................................................2-7 3. Component Names................................................................................... 3-1 4. Installation.................................................................................................. 4-1 4.1 Precautions ........................................................................................................4-1 4.2 Mounting.............................................................................................................4-1 4.3 Rotating Transmitter Section............................................................................4-2 4.4 Changing the Direction of Integral Indicator .................................................4-2 4.5 Changing the direction of the antenna............................................................4-3 ii IM 01C27F01-01EN 5. Installing Impulse Piping.......................................................................... 5-1 5.1 Impulse Piping Installation Precautions.........................................................5-1 5.1.1 Connecting Impulse Piping to a Transmitter.......................................5-1 5.1.2 Routing the Impulse Piping.................................................................5-1 5.2 Impulse Piping Connection Examples............................................................5-2 6. Grounding.................................................................................................. 6-1 7. Operation.................................................................................................... 7-1 7.1 Preparation for Starting Operation..................................................................7-1 7.2 Zero Point Adjustment......................................................................................7-2 7.3 Starting Operation.............................................................................................7-2 7.4 Connecting to the Field Wireless Network......................................................7-3 7.5 Shutting Down the Transmitter........................................................................7-4 8. Setting Parameters.................................................................................... 8-1 8.1 Environment for parameter setting..................................................................8-1 8.2 Preparing Software for the Configuration Tool..............................................8-1 8.3 Setting Parameters............................................................................................8-2 8.3.1 Parameter Usage and Selection.........................................................8-2 8.3.2 Function Block and Menu Tree...........................................................8-3 8.3.3 Parameters for Wireless Communication.........................................8-10 8.3.4 Tag and Device Information.............................................................. 8-11 8.3.5 Unit.................................................................................................... 8-11 8.3.6 Range Change.................................................................................. 8-11 8.3.7 Output Signal Low Cut Mode Setup................................................. 8-11 8.3.8 Integral Indicator Scale Setup...........................................................8-12 8.3.9 Unit for Displayed Temperature........................................................8-12 8.3.10 Zero Point Adjustment and Span Adjustment...................................8-12 8.3.11 Software Write Protect......................................................................8-14 8.3.12 Switching to Deep Sleep Mode.........................................................8-14 8.3.13 Switching to Silence Mode................................................................8-14 8.4 Self-Diagnostics...............................................................................................8-15 8.4.1 Identify Problems by Using the Communicator................................8-15 8.4.2 Checking with Integral Indicator........................................................8-17 9. Maintenance............................................................................................... 9-1 9.1 Overview.............................................................................................................9-1 9.2 Calibration Instruments Selection...................................................................9-1 9.3 Calibration..........................................................................................................9-1 9.4 Disassembly and Reassembly.........................................................................9-3 9.4.1 Replacing the Integral Indicator..........................................................9-3 9.4.2 Replacing the RF Assembly................................................................9-4 9.4.3 Replacing the CPU Assembly.............................................................9-4 9.4.4 Cleaning and Replacing the Capsule Assembly................................9-5