Zamel PNM-32 Manuals

1 pdf manual(s) Zamel PNM-32 for free download (Document Types: Instruction manual)

Zamel PNM-32 Instruction manual [PDF] (2 pages)

  • Identifier: id-2278769
  • Brand: Zamel
  • Device: PNM-32 Relays
  • Type: PDF
  • Key Aspects: Performance Optimization Tips, Glossary of Technical Terms, Troubleshooting Information
  • UPD Date: 14.03.2026
  • Source File: 2008856.pdf
  • Pages: 2
  • Description: Installation instructions for the Zamel PNM-32.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
VOLTAGE RELAY PNM-32 INSTRUCTION MANUAL Zakład Mechaniki i Elektroniki ZAMEL sp.j. J.W. Dzida, K. Łodzińska ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: [email protected] CONNECTION APPERANCE MAIN RESET MOUNTING DIMENSIONS PRODUCT FAMILY The PNM-32 is a member of the PNM product family. 1. Disconnect power supply by the pha- se fuse, the circuit-breaker or the switch- disconnector combined to the proper circuit. 2. Check if there is no voltage on con- nection cables by means of a spe- cial measure equipment. 3. Install the PNM-32 on the TH-35 DIN rail in the switchboard. 4. Connect the cables with the terminals in accordance with the installing dia- gram. 5. Switch on the power supply from the mains. WARRANTY CARD INNER DIAGRAM In order to cancel the circuit data and set de- fault values it is necessary, in the main win- dow, to press and hold simultaneously ( and ) keys for 3 seconds; All display fields will be lighted; The main window will be entered after a while. FUNCTIONING After power supply switching on it is necessary to set maximum and minimum voltage, hy- steresis, phase unbalance and the relay ON-time and OFF-time. If not, the following default values will be set = 235 V, = 225 V, = 1 V, = 2 s, = 2 s, = 10 V. If all phase voltages are greater or equal to 170 V, automatic phase sequence checking will start. In case of incorrect phase sequence the output relay will be switched OFF ( ), the symbol will be displayed: , and a message with info which phases are to be changed over in or- der to set a correct phase sequence will be displayed too. If the phase sequence is correct, the device will start displaying measured voltages in three-second cycles (see the figure) and voltages controlling. It is possible to toggle between the phases by pressing the cursors which causes breaking cyclic phase voltages display (every 3 s) and holding the set phase display for 20 seconds. If the voltages are in- cluded within the set range ( , ), after time the relay will be ON ( ). Any voltage threshold exceeding for the given phase will be signalled by displaying the following sym- bol: for the minimum threshold and the symbol for the max voltage , and start counting the time , and then will switch OFF the output relay ( ). If, during displaying e.g. the L3 phase voltage, the L1 or L2 phase voltage falls below the voltage threshold , or exceeds the min , threshold, the device will toggle the phase value displayed actually to the phase with the incorrect voltage value and will remain in this state until the wrong va- lue disappears or the relay is OFF. Układ wykrywa również asymetrię napięcia. The device is capable of detecting voltage unbalance. If the potential difference between the phases is greater than , the display will show , and after time the relay will be OFF ( ). L2 L1 L3 KLAW. LCD μC ZAS. A/C A/C A/C N FEATURES TECHNICAL DATA DESCRIPTION PNM-32 Power terminals: L1, L2, L3, N Rated voltage: 230/400 V AC Rated voltage tolerance: -15 ÷ +10 % Rated frequency: 50 / 60 Hz Rated current: 2 W / 14 VA Measured voltage indicator: wyświetlacz LCD Relay state and soft network indicator: wyświetlacz LCD Voltage unbalance / phase sequence indicator: wyświetlacz LCD Voltage threshold settings: klawiatura Umin adjustment range: 170 ÷ 225 V Umax adjustment range: 235 ÷ 290 V Voltage hysteresis adjustment range: 1 ÷ 4 V Unbalance level adjustment range: 10 ÷ 60 V OFF-time toff: 2 ÷ 15 s keyboard ON-time ton: 2 ÷ 15 s keyboard Time setting accuracy: max ±1 s / 24 h at temp. 25 °C Voltage measurement accuracy (50 Hz sinus): ±1,5 %* Output relay parameters: 1NO/NC - 16 A / 250 V AC1 4000 VA Number of terminal clamps: 12 Section of connecting cables: 0,2 ÷ 2,50 mm2 Ambient temperature range: -20 ÷ +60 oC Operating position: freely Mounting: rail TH 35 (PN-EN 60715) Protection degree: IP20 (PN-EN 60529) Protection level: II Overvoltage category: II Pollution degree: 2 Dimensions: double-modular (35 mm) 90x35x66 mm Weight: 0,12 kg Reference standards: PN-EN 60730-1; PN-EN 60730-2-1; PN-EN 61000-4-2,3,4,5,6,11 * The PNM-32 device is not fitted with the True RMS converter and therefore only 50 Hz sinusoidal voltages can be measured correctly; if there are significant harmonic distortions, the measurement result error may be serious. ● Three-phase load protection against voltage swing and unbalance, and incorrect phase sequence, ● Measured voltage state indicator, ● Relay state indicator, ● The device supplying with any phase, ● Minimum (170 ÷ 225 V) and maximum (235 ÷ 290 V) voltage setting, ● OFF-time delay adjustment, ● Voltage control for each phase, ● Correct phase sequence control, ● Voltage unbalance control, ● Relay output - single changeover contact, maximum load 16 A, ● Mounted on TH 35 rail. The PNM-32 voltage relay is designed for the three-phase system voltage con- trol and load protection. It is possible to set minimum and maximum voltage, hysteresis, voltage unbalance and ON / OFF delay. The device is capable of detecting voltage unbalance and phase sequence. The LCD display and keybo- ard enable easy parameters visualization and programming. The device is designed for three-phase installation and must be installed in accor- dance with standards valid in a particular country. The device should be connec- ted according to the details included in this operating manual. Installa- tion, connection and control should be car- ried out by a qualified electrician staff, who act in accordance with the service manual and the device functions. Disassembling of the device is equal with a loss of guarantee and can cause electric shock. Before in- stallation make sure the connection cables are not under voltage. The cruciform head screwdriver 3,5 mm should be used to in- stal the device. Improper transport, storage, and use of the device influence its wrong functioning. It is not advisable to instal the device in the following cases: if any device part is missing or the device is damaged or deformed. In case of improper functioning of the device contact the producer. CAUTION Values (voltage, time) Information field Relay mode Relay output terminals (12, 11, 14) Power / measure terminals (L1, L2, L3) Power terminal (N) Display Control buttons VER. 001_14.09.2009 The symbol means selective collecting of electrical and electronical equipment. It is forbidden to put the used equipment together with other waste Device version: 10 – single phase 31 – three-phase 32 – three-phase, LCD Device type There is 24 months guarantee on the product Salesman stamp and signature, date of sale 1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product. 2. The manufacturer’s guarantee does not cover any of the following actions: a) mechanical damage during transport, loading / unloading or under other circumstances, b) damage caused by incorrect product mounting or misuse, c) damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other devices needed for the product functioning, d) damage caused by Act of God or any other incidents independent of the manufacturer. 3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J. 4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation. 5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement or money return. 6. The manufacturer’s guarantee is valid in the Republic of Poland. 7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or otherwise are not affected by this warranty.

PNM-32: Related Instructions

RNK-02
Zamel RNK-02
06.05.2026 34 pages

η RADIOWY NADAJNIK KLAWISZOWY 2-KANAŁOWY RNK-02 Zamel Sp. z o.o., ul. Zielona 27, 43-200 Pszczyna tel.: +48 32 210 46 65, +48 32 449 15 00, fax: +48 32 210 80 Complete device guide for the Zamel RNK-02 Transmitter. It details safety instructions and performance details, safety information, system checks.

Ledix WDN-03
Zamel Ledix WDN-03
28.05.2026 2 pages

www.ledix.pl 230 V AC Cet Lighting Sp. z o.o. 43-200 Pszczyna, ul. Zielona 27 tel: +48 32 449 15 00, fax: +48 32 449 15 02 e-mail: [email protected], www.ledix.pl Complete installation manual for the Zamel Ledix WDN-03 Switch. This guide presents control functions, troubleshooting, reset instructions, connectivity setup.

exta life ROB-21
Zamel exta life ROB-21
20.04.2026 24 pages

η η ∆ Zamel Sp. z o.o., ul. Zielona 27, 43-200 Pszczyna tel.: +48 32 210 46 65, +48 32 449 15 00, fax: +48 32 210 80 04 e-mail: [email protected] www.zamel Stepwise user guide for the Zamel exta life ROB-21 Controller. It details device setup and maintenance, product maintenance, service instructions.

VP-810BHD
Zamel VP-810BHD
21.05.2026 58 pages

Dziękujemy za wybór naszego produktu. Firma Zamel nie odpowiada za uszkodzenia oraz wypadki spowodowane niezgodnym z przeznaczeniem użytkowaniem produktu. Pr Device instruction guide for the Zamel VP-810BHD Intercom System. It provides guidance on system configuration, setup instructions, connectivity options.

gardi ZMB-01/C
Zamel gardi ZMB-01/C
05.08.2026 2 pages

WIRELESS WI-FI CAMERA ZMB-01/C USER MANUAL ZAMEL sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamel.co Manual for safe operation of the Zamel gardi ZMB-01/C Digital Camera. The manual outlines technical specifications and operating instructions, installation steps, shutdown procedures, safety precautions.

exta LKM-02
Zamel exta LKM-02
14.06.2026 2 pages

POWER SUPPLY INDICATOR LKM-02 INSTRUCTION MANUAL Zakład Mechaniki i Elektroniki ZAMEL sp.j. J.W. Dzida, K. Łodzińska ul. Zielona 27, 43-200 Pszczyna, Poland Official operating instructions for the Zamel exta LKM-02 Measuring Instruments. The manual covers procedures for technical specifications, safety information, device safety checks, service contacts.

Similar Manuals in the Relays Category

GH55
Ghisalba GH55
30.08.2026 8 pages

1 D. 9.305.791 - CD33134 cod. 5.806.789 D5-01 Istruzioni d'impiego contattori Operating instructions for contactors GH55 - GH57 Generalità I contattori monobl Device setup manual for the Ghisalba GH55 Relays. It contains information on operational safety, reset instructions, service instructions.

PAN04
Philio PAN04
31.08.2026 20 pages

PAN04 In Wall Dual relay(1 way) switch module Fig 1. Assembling This in-wall dual relay switch module is a transceiver which is a Z-Wave PlusTM enabled device User instruction manual for the Philio PAN04 Relays. The manual provides step-by-step instructions on regulatory notices, security instructions, usage examples, device safety checks.

4100 Series
Simplex 4100 Series
15.05.2026 18 pages

574-050 Rev. N 4100/4120-Series VESDA Interface Cards Installation Instructions *0574050N* Cautions, warnings, and regulatory information READ AND SAVE THESE Instruction guidebook for the Simplex 4100 Series Recording Equipment. This guide explains technical procedures for specifications, security instructions, product handling.

880 Performance Series
Rice Lake 880 Performance Series
30.05.2026 10 pages

880 Truck In/Out Program Optional Software Application Version 1 Operation Manual PN 176050 Instruction reference guide for the Rice Lake 880 Performance Series Kitchen Appliances. It includes maintenance procedures and hardware components, installation procedures, device overview, startup procedures.