Release 2.02 Part No.3C63917 010-11582-3005 Published July 1998 ...
Santa Clara, California 95052-8145 © 3Com Corporation, 1998. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without permission from 3Com Corporation. 3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligatio ...
Power and Power Cords ix EMI x Safety Classification of Ports for Connection to Telecommunications Networks x S UPPLEMENTARY R EGULATORY I NFORMATION Host Chassis/Module Compatibility and Creepage/Clearance Requirements xi FCC Part 68 Statement xii CE Notice xiii A BOUT THIS G UIDE Introduction 15 How to Use This Guide 15 Conventions 16 Related Do ...
Connecting an E3 UNI Module 36 Connecting an OC3/STM-1 UNI Trunk/Port Module 37 Connecting a DS1/E1 UNI with IMA Module 37 Connecting an Ethernet Module 39 Connecting a CBR DSX or CBR E1 Port Module 41 Connecting a QSIM V.35/RS422/EIA530 Port Module 42 Connecting a HSIM Module 53 Connecting a DS1 Frame Access Module 53 Verifying CPU LEDs and Connecting the Office Alarm Connector 54 Con ...
Ethernet Module Operation 79 CBR DSX/E1 Module Overview 80 CBR DSX Module 80 CBR E1 Module 81 QSIM/HSIM/FAM Module Overview 82 Application Overview 83 Bridging 83 Filtering 84 Addressing 84 Virtual Circuits 84 Learning Bridge 85 Segmentation 86 Reassembly 87 Spanning Tree 87 Spanning Tree Operation 87 Spanning Tree Instances 88 CBR Application 88 St ...
Configuring the Management CPU 117 Viewing MCPU Configuration Information 118 Configuring Virtual Interfaces 118 Adding Virtual Interfaces 118 Viewing and/or Modifying Existing Virtual Interfaces 119 Deleting Virtual Interfaces 120 Configuring Input Shapers 121 Configuring the STX Module 122 Configuring the OC3/STM-1 UNI Module 123 Configuring the DS3 UNI Module 125 Configuring ...
Modifying a Virtual Circuit 185 Deleting a Virtual Circuit 186 Viewing Virtual Circuit Statistics 186 6 P ATH B UILDER S600 D IAGNOSTICS AND P ERFORMANCE M ONITORING Managing System Alarms 187 Viewing and Clearing Current Alarms 188 PathBuilder S600 Alarm Messages (STX) 189 Working with History Alarms 194 Viewing and Printing History Alarms 194 Clearing History Alarms 195 Usin ...
Servicing Service of this unit is to be performed by qualified service personnel only. Service of certain components and subassemblies in this equipment is accomplished by the replacement of Field Replaceable Units (FRUs). However, safety agency approval requires that the servicing of other subassemblies within this product be referred to 3Com’s service personnel. T ...
rated 6 amps, consisting of a minimum 18 AWG, Type SVT or SJT three conductor cord maximum of 15 feet in length, with a NEMA 5-15P plug. INTERNATIONAL APPLICATIONS: The power supply cords used with this equipment should be harmonized with all local standards applicable in the country in which it is installed. Safety agency compliance requires this ...
creepage/clearance requirements. It also describes the compliance of the PathBuilder ® S600 with FCC and CE regulations. Host Chassis/Module Compatibility and Creepage/Clearance Requirements The installer of the E1 CBR and E3 UNI Module must ensure that the host chassis and module are compatible and that the host chassis is capable of pr ...
Clearance (distance X in the figure below) is defined as the shortest distance between two conductive parts, or between the conductive part and the bonding surface of the equipment, measured through air. Creepage (distance Y in the figure below) is defined as the shortest path between two conductive parts, or between the conductive part and the bonding surface of the equipment, measured along the surfa ...
EMC, Telecom and Low Voltage dIrectives of the European Community. Such marking is indicative that this equipment meets or exceeds the following technical standards. EN55022—Limits and methods of measurement of radio interference characteristics of information technology equipment. EN50082-1—Electromagnetic compatibility - generic immunity standard part 1: residential, co ...
About This Guide provides an overview of this guide, describes guide conventions, tells you where to look for specific information and lists other publications that may be useful. Introduction This guide describes how to install and configure the PathBuilder S600 WAN Access Switch (PathBuilder S600). It also provides an overview of the unit’s modules and supported applications. Audience Description This guide is intended for network ad ...
Conventions Table 2 and Table 3 list conventions that are used throughout this guide. Table 2 Notice Icons Icon Notice Type Alerts you to... Information note Important features or instructions Caution Risk of personal safety, system damage, or loss of data Warning Risk of severe personal injury Table 3 Text Conventions Convention Description Syntax The word “syntax” means you must evaluate the syntax provided and supply the appr ...
PathBuilder S600. PathBuilder S600 Release Notes—Provides configuration help and information about new features and any known limitations and issues found in the release. PathBuilder Switch Manager User Guide—Describes how to use PathBuilder Switch Manager to configure and manage PathBuilder WAN access switches. Using PathBuilder ...
technology, describes the PathBuilder® S600 WAN Access Switch (PathBuilder S600), and lists PathBuilder S600 system specifications. It includes the following sections: n ATM Overview n PathBuilder S600 with STX Overview n Specifications n Options and Parts List ATM Overview ATM provides the means of simultaneously transferring a wide variety of services with ...
Each transmission direction in a virtual circuit is referred to as a virtual channel. Virtual channels are then grouped into virtual paths between two ports. The channels and paths are assigned numbers: VPIs (Virtual Path Indicators) and VCIs (Virtual Channel Indicators). Each ATM cell (a fixed-length unit of data over ATM) is assigned to a virtual circuit by including the circuit's VPI/VCI in the cell's header. This is th ...
Related Devices for 3Com 3C63100-AC-C - PathBuilder S600 Bridge/router:
User support manual for the 3Com AirConnect 9550 Wireless Access Point. It details safety instructions and service instructions, setup tips, product handling.
This manual covers installation and operating instructions for the following 3Com modem: U.S. Robotics 56 kbps∗ Winmodem™ U.S. Robotics is a registered trad Instruction and reference manual for the 3Com 005683-00 - Robotics. It offers details on regulatory notices, error handling, installation, safety information.
User instruction manual for the 3Com AirProtect Enterprise Engine 6100 Network Accessory. It offers details on support details, setup guidelines, service procedures.
® http://www.3com.com/ SuperStack ® II PS Hub User Guide 3C16405 — PS Hub 40 12-port 3C16406 — PS Hub 40 24-port 3C16450 — PS Hub 50 24-port Part No. DU User instructions for the 3Com PS Hub 40 Switch. This documentation guides on device overview, startup procedures, security instructions, troubleshooting guides.
OfficeConnect® Gateway ADSL Data (3CR100A97) Quick Start Guide Device maintenance guide for the 3Com 3CR100A97 Gateway. This guide presents startup procedures, wiring setup, configuration options.
VCX™ Business Telephone Guide VCX™ Connect IP Telephony Solution System Release 9.5 6W101-20100430 Published April 2010 http://www.3com.com/ Installation and maintenance guide for the 3Com VCX Telephone. This documentation details procedures for operating modes, application scenarios, technical troubleshooting.
FE574BT C Card ctions nce er Complete technical documentation for the 3Com 3C3FE574BT Computer Hardware. This reference includes maintenance, security instructions, regulatory notices.
Chassis ID Printed Circuit Board For the CoreBuilder® 9000 Enterprise Switch The chassis ID printed circuit board (PCB) (Model Number 3CB9EE) for the CoreBuild Maintenance instructions for the 3Com 9000 Chassis. This manual covers installation, operation, and software installation, usage examples, assembly reference, reset instructions.
Network Router: Frequently Requested PDF Instructions
ISW Series Managed Industrial Ethernet Switch Command Reference Guide ISW 4-10/100P, 2-10/100T, 2-SFP ISW 4GbP, 2GbT, 2-SFP ISW 8-10/100P, 4-SFP ISW 8GbP, 4-SFP Operation instructions for the EXTREME SWITCHING ISW 4-10/100P Network Router. This guide offers instructions on system configuration, testing procedures, network setup.
Official product manual for the Atlantis NetMaster G5P Network Router. The document explains wiring setup, user preferences, software installation.
1 Quick Install Guide+ Installationsanleitung+ Guide d’installation+ Guía de instalación+ Guida di Installazione+ Installatiehandleiding+ Instrukcja instala Complete instruction guide for the D-Link DKT-410 Network Router. It includes usage scenarios and technical assistance, safety precautions, safety, specifications.
TE100-S16R TE100-S24R Quick Installation Guide Owner’s manual for the TRENDnet TE100-S16R Network Router. It explains maintenance and specifications, system checks, error handling, safety.