Microwave Motion Sensor

Model: HC002S 99 190 12 Instruction manual EN The sensor is an active motion detector; it emits a high-fre- quency electromagnetic wave 5.8GHz and receives its echo. The sensor detects the change in echo from movement in its detection zone. A microprocessor then triggers the switch light ON command. Detection is possible through doors, glass panels and thin walls. NOTE: the high-frequency output of this sensor is <0.2mW; approximately just 2‰ of the transmission power of a mobile telephone or the output of a microwave oven. LED indication Daylight sensor TECHNICAL Specifications IMPORTANT PLEASE READ THESE INSTRUCTION CAREFULLY PRIOR TO INSTALLATION AND RETAIN THIS LEAFLET IN A KNOWN AND SAFE PLACE FOR FUTURE REFERENCE. Product type: Microwave Motion Sensor Operating voltage: 220-240V~ 50/60Hz HF system: 5.8GHz CW radar Transmission power: <0.2mW Rated load: 1200W (resistive load), 400W (capacitive load) Detection angle: 30-150º Power consumption: Approx 0.5W Detection range: Max. 12 m in diameter, adjustable Time setting: 5 s ~ 30 min. Mounting: Indoors, ceiling or wall Light control: 2~50 LUX, disable Working temperature: -20~60ºC The sensor works with a main voltage of 220-240V AC 50/60Hz, 100-120V AC version is available on request. The sensor has a 4-wire electrical interface: Nx2 (neutral / 220-240V AC) L (phase / 220-240V AC) L’ (switched phase / output) INSTALLATION & WIRING Sensorn funkar med spänning 220-240V AC 50/60Hz, en version med 100-120V AC finns tillgänglig på begäran. Sensorn har fyra plintar: Nx2 (nolla / 220-240V AC) L (fas / 220-240V AC) L’ (tändtråd) Försäkra dig om att strömmen är helt avstängd innan installation eller underhåll. SE Ensure that the electricity supply is switched off complete- ly before installation or servicing this product. EN <0.2mW Approx. 100mW

This determines the time the fitting remains at 100% level on

motion detection and is set with DIP switches at the sensor itself, refer to figure. The following settings are available: I – 5s II – 30s III – 1 minutes IV – 5 minutes V – 10 minutes VI – 30 minutes Detection Area: This determines the effective range of the motion detector and is set by DIP switches at the sensor itself, refer to figure. Note that reducing the sensitivity will also narrow the detection range. The following settings are available: I – Detection range 100% II – Detection range 75% III – Detection range 50% IV – Detection range 25% V – Detection range 10% Daylight sensor: This setting holds off the 100% light output should there be sufficient daylight and is set using DIP switches at the sensor, refer to figure. The following settings are available: I – 2 lux II – 10 lux III – 30 lux IV – 50 lux V – disable Settings *In disable mode the lamp(s) will always be on with motion detected and operate at 100% light output, even in bright daylight. Detection Area 1 2 3 I 100% II 75% III 50% IV 25% V 10% Hold time 1 2 3 4 I 5s II 30s III 1min IV 5min V 10min VI 30min Daylight Sensor 1 2 3 I 2Lux II 10Lux III 30Lux IV 50Lux V Disable To connect several control gears with 1 sensor (ON-OFF function), the wiring should be: This sensor is suitable for indoor use. Max. installation height is 6 meters.

Malmbergs Elektriska AB, PO Box 144, SE-692 23 Kumla, SWEDEN

Phone: +46 (0)19 58 77 00 Fax: +46 (0)19 57 11 77 [email protected] www.malmbergs.com TROUBLE SHOOTING Malfunction Cause Remedy The load does not work Incorrect light-control setting selected Adjust setting Load faulty Replace load Mains switched OFF Switch ON The load is always on Continuous movement in the detection zone Check zone setting The load is on without any identifiable movement The sensor is not mounted reliably for detecting movement Securely mount enclosure Movement occurred, but not identified by the sensor (movement behind wall, movement of small object in immediate lamp vicinity etc.) Check zone setting The load does not work despite movement Rapid movements are being suppressed to minimize malfunctioning or the detection radius is too small Check zone setting FUNCTIONS 3.1 100H burn-in mode for fluorescent lamp With simple operation, rapidly turn off/on the fixture 3 cycles within 3 sec. (the green LED on the sensor as well as the fixture will blink 3 times to indicate the success of setup), lamp will be 100% on for 100 hours, and then automatically goes to sensor mode after 100 hours. This is crucial to secure the lifetime of fluorescent lamp, when new fixture is installed, or old lamp is replaced. This 100h burn-in feature can be cancelled by turning off/on the fixture 1 cycle within 1 sec. 3.2 Set daylight threshold freely With simple operation, rapidly turn off/on the fixture 2 cycles within 2 sec: a. the green LED on the sensor will flash slowly for 5 seconds, meanwhile the fixture blink twice. b. the daylight sensor measures and remembers the surrounding lux for 1 sec. c. the fixture and green LED will be on for 10s to indicate the success of learning. • This feature enables the fixture to function well in any real application circumstance, where the daylight that penetrate into fixture may vary a lot. • The latest surrounding lux value overwrites previous lux value learned. • Both the setting on DIP switch and the learned ambient lux threshold can overwrite each other. The latest action stays in validity. 3.3 Zero-cross relay operation Designed in the software, the sensor switches on/off the load right on the zero-cross point, to ensure the min. current pass- ing through the relay contact point, and enable the max. load and life-time of the relay.