AF-JA/JZ-150129
Microwave Motion Sensor
Model: HC002S
99 190 12
Instruction manual
EN
The sensor is an active motion detector; it emits a high-fre-
quency electromagnetic wave 5.8GHz and receives its echo.
The sensor detects the change in echo from movement in
its detection zone. A microprocessor then triggers the switch
light ON command. Detection is possible through doors, glass
panels and thin walls.
NOTE: the high-frequency output of this sensor is <0.2mW;
approximately just 2‰ of the transmission power of a mobile
telephone or the output of a microwave oven.
LED indication
Daylight sensor
TECHNICAL Specifications
IMPORTANT
PLEASE READ THESE INSTRUCTION CAREFULLY PRIOR TO INSTALLATION AND RETAIN THIS LEAFLET IN A
KNOWN AND SAFE PLACE FOR FUTURE REFERENCE.
Product type:
Microwave Motion Sensor
Operating voltage:
220-240V~ 50/60Hz
HF system:
5.8GHz CW radar
Transmission power:
<0.2mW
Rated load:
1200W (resistive load),
400W (capacitive load)
Detection angle:
30-150º
Power consumption:
Approx 0.5W
Detection range:
Max. 12 m in diameter, adjustable
Time setting:
5 s ~ 30 min.
Mounting:
Indoors, ceiling or wall
Light control:
2~50 LUX, disable
Working temperature:
-20~60ºC
The sensor works with a main voltage of 220-240V AC
50/60Hz, 100-120V AC version is available on request.
The sensor has a 4-wire electrical interface:
Nx2 (neutral / 220-240V AC)
L (phase / 220-240V AC)
L’ (switched phase / output)
INSTALLATION & WIRING
Sensorn funkar med spänning 220-240V AC 50/60Hz, en
version med 100-120V AC finns tillgänglig på begäran.
Sensorn har fyra plintar:
Nx2 (nolla / 220-240V AC)
L (fas / 220-240V AC)
L’ (tändtråd)
Försäkra dig om att strömmen är helt avstängd innan
installation eller underhåll.
SE
Ensure that the electricity supply is switched off complete-
ly before installation or servicing this product.
EN
<0.2mW
Approx. 100mW
AF-JA/JZ-150129
Hold time:
This determines the time the fitting remains at 100% level on
motion detection and is set with DIP switches at the sensor
itself, refer to figure.
The following settings are available:
I – 5s
II – 30s
III – 1 minutes
IV – 5 minutes
V – 10 minutes
VI – 30 minutes
Detection Area:
This determines the effective range of the motion detector
and is set by DIP switches at the sensor itself, refer to figure.
Note that reducing the sensitivity will also narrow the detection
range.
The following settings are available:
I – Detection range 100%
II – Detection range 75%
III – Detection range 50%
IV – Detection range 25%
V – Detection range 10%
Daylight sensor:
This setting holds off the 100% light output should there be
sufficient daylight and is set using DIP switches at the sensor,
refer to figure. The following settings are available:
I – 2 lux
II – 10 lux
III – 30 lux
IV – 50 lux
V – disable
Settings
*In disable mode the lamp(s) will always be on with motion detected and operate at 100% light output, even in bright
daylight.
Detection Area
1
2
3
I
100%
II
75%
III
50%
IV
25%
V
10%
Hold time
1
2
3
4
I
5s
II
30s
III
1min
IV
5min
V
10min
VI
30min
Daylight Sensor
1
2
3
I
2Lux
II
10Lux
III
30Lux
IV
50Lux
V
Disable
To connect several control gears with 1 sensor (ON-OFF function), the wiring should be:
This sensor is suitable for indoor use. Max. installation height is 6 meters.
AF-JA/JZ-150129
Malmbergs Elektriska AB, PO Box 144, SE-692 23 Kumla, SWEDEN
Phone: +46 (0)19 58 77 00 Fax: +46 (0)19 57 11 77
[email protected] www.malmbergs.com
TROUBLE SHOOTING
Malfunction
Cause
Remedy
The load does not work
Incorrect light-control setting selected
Adjust setting
Load faulty
Replace load
Mains switched OFF
Switch ON
The load is always on
Continuous movement in the detection zone
Check zone setting
The load is on without any
identifiable movement
The sensor is not mounted reliably for detecting
movement
Securely mount enclosure
Movement occurred, but not identified by the sensor
(movement behind wall, movement of small object in
immediate lamp vicinity etc.)
Check zone setting
The load does not work despite
movement
Rapid movements are being suppressed to minimize
malfunctioning or the detection radius is too small
Check zone setting
FUNCTIONS
3.1 100H burn-in mode for fluorescent lamp
With simple operation, rapidly turn off/on the fixture 3 cycles within 3 sec. (the green LED on the sensor as well as the
fixture will blink 3 times to indicate the success of setup), lamp will be 100% on for 100 hours, and then automatically goes
to sensor mode after 100 hours. This is crucial to secure the lifetime of fluorescent lamp, when new fixture is installed, or old
lamp is replaced. This 100h burn-in feature can be cancelled by turning off/on the fixture 1 cycle within 1 sec.
3.2 Set daylight threshold freely
With simple operation, rapidly turn off/on the fixture 2 cycles within 2 sec:
a. the green LED on the sensor will flash slowly for 5 seconds, meanwhile the fixture blink twice.
b. the daylight sensor measures and remembers the surrounding lux for 1 sec.
c. the fixture and green LED will be on for 10s to indicate the success of learning.
• This feature enables the fixture to function well in any real application circumstance, where the daylight that penetrate
into fixture may vary a lot.
• The latest surrounding lux value overwrites previous lux value learned.
• Both the setting on DIP switch and the learned ambient lux threshold can overwrite each other. The latest action stays in
validity.
3.3 Zero-cross relay operation
Designed in the software, the sensor switches on/off the load right on the zero-cross point, to ensure the min. current pass-
ing through the relay contact point, and enable the max. load and life-time of the relay.