[email protected] www.master-audio.com Nov 2008 ...
operated. 2. The exclamation point within an equilateral triangle is intended to alert the user of the presence of internal components whose substitution may affect safety. 3. The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user of the presence of un ...
MAW Series, specially designed for Line Array configurations. The accumulated experience of more than 30 years in the design of acoustic cabinets and amplifiers, together with the application of the most advanced technology and transducers, have allowed this series to become the optimal and ...
Kit Stacking to adapt the MA210 on the MAW218 (see point 5). Fig.1. Dimensions of MAW-218D 2.3. MAW-218/D System D=DSP version of MAW-218 with in-built amplification and internal processing through DSP included.. The Class D amplification modules are 3000 W Their high efficiency (almost 90%) allows their location on th ...
B) RJ45 LINK : PC Link Signal C) INPUT SIGNAL : Balanced XLR input signal connector 1= Ground 2= Live 3= Return D) LINK INPUT SIGNAL : Balanced XLR connector for paralleling several units, which will share the same input. 1= Ground 2= Live 3= Return E) AC INPUT : Input PowerCon connector. F) AC STACKING OUTPUT : PowerCon Output connector to feed a second ...
cabinet stops working (or works intermittently) until the correct voltage values are reached again. 4.FLYING The MAW218D cannot be flown. 5.STACKING The STK210/218 Hardware adapts the MAW218 with the MA210. With this accessory you can stack MA210 units over the MAW218 subwoofer. MA210 + MAW218 You need STK210/218 Kit Stacking ...
MAW-218/D7 Line Input (Balanced) Impedance 1.8 V 10k ohms Mains 230V +/- 10% Consumption at Maximum Power 12 A Frequency Response LF Usable bandwidth 30 Hz - 130 Hz (-10 dB) (1W, processed) Sensitivity LF (1W @ 1m) 103 dB SPL Amplifier Power LF 3000 W Nominal Directivity (-6dB) Horizontal omnidirectional Vertical omnidirectional System Output Continuous SPL (Long Term) One enc ...
• The internal Breaker automatically protects the cabinet in case of bad working. No Sound • Check that the mixer, sound source and processor is sending signal to the unit. • Check that the cable from the mixer, sound source or processor to the units is correctly connected. Replace the cable if defective. • Make sure the ...