MAX Phantom 2000

Installation and Owners Manual www.max.us.com 4009963 High Traffic Commercial Brushless DC Low Profile Swing Gate Operator Made in USA CONFORMS TO UL STD 325 UL CLASS - I, II, III, IV CERTIFIED TO CAN/CSA STD C22.2 NO. 247

© 2014 Maximum Controls LLC.

All rights reserved. No part of this manual may be reproduced in any means: graphics, electronics or mechanical, including photocopying without the expressed written permission of the publisher. Materials components and specifications are subject to change without notice. Phantom 2000 Specifications Important Safety Information UL 325 Model Classifications UL 325 Required Entrapment Protection UL 325 Compliant Installation Requirements Intended Use of Swing Gate Operator Installation Gate Operator Position Recommended Gate Operator Layout Single Gate Operator Dual Gate Operators Arm Position Options Arm Connection to Gate Optional Remote Power Supply Kit - MAX Magic Box Solar Optional Install Warning Signs Entrapment Protection In-Ground Loops Wiring operator Gate Operator System Overview Input AC Power Optional Remote Power Supply Kit - MAX Magic Box Solar Power Connection - Optional Operators to Matrix 1 Optional Key Switch to Operator(s) Turn ON / OFF Operator Power matrix 1 Matrix 1 Overview Wiring Overview Primary Gate - Open Left / Open Right Close Timer Selectable Gate Speed Control Battery Back-Up Mode Anti-Tailgate Single Pass Anti-Tailgate Radio Receiver Radio Safety Pause Gate in Motion Alarms OBD Port Black Box Maglock Loop Detectors In-Ground Loop Connection ID Plug Gate Tamper UL Entrapment LEDs Emergency Vehicle / Max Open Inputs Gate Disable Partial Open UL Alarm / Alarm Reset Button Gate Status Monitoring OPEN / STOP / CLOSE Connection CLOSING Photocell Connection Gate Operators Communication LEDs 24V Power for Matrix 1 Battery in Use LED Motor Motion LEDs Table of contents 2 2 3 3 4 5 6 7 8 9 10 10 11 12 13 14 15 16-17 18 19 20 21 22 23 24 25 26 26 26 26 27 27 28 28 28 28 29 29 29 30 30 30 30 31 31 32 32 32 32 33 33 33 33 Adjustments Open and Close Limits Release Handle Clamp Reverse Sensor (ERD) Maintenance Qualified gate operator technician End user/Home owner Phantom 2000 Wiring Schematics Manual Release Electronic Gate Open / Close Audible Alarm Replacement Parts List Warranty Phantom options / unique features Gate Tamper Feature 36 Amp/Hr Phantom Battery Module - Optional Gate Disable Feature Event History Download 37 37 38 39 40 40 41 42 43 43 44 44 34 35 36

WARNING – To reduce the risk of injury or death:

1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death. 5. Use the emergency release only when the gate is not moving. 6. KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate hardware. 7. The entrance is for vehicles only. Pedestrians must use separate entrance. 8. SAVE THESE INSTRUCTIONS UL 325 Class of Operation - Class I, II, III, IV Gate Type - Vehicular Swing Gate Max Gate Weight / Length - 2000lbs @ 15 ft or 1500 lbs @ 20 ft 90° Opening Time - 16 selectable speeds from approximately 11.5 sec to 20 sec depending on the weight and length of gate. Cycles per Hour AC Input Power - Continuous Battery Back-Up Cycles (Batteries fully charged): - BC-7 Battery Module-7 Amp/Hr Batteries, approximately 450 cycles - BC-36 Phantom Battery Module-36 Amp/Hr Batteries, approximately 2000 cycles Input AC Power - Switchable: 115VAC or 230VAC single phase Motor - 24VDC Brushless (equivalent to 1 HP AC motor) Operating Temperature - -4°F to 158°F (-20°C to 70°C) Entrapment Protection: - UL 325 Type A Inherent (ERD sensor) - Input for UL 325 Type B1 (photocell) and B2 (sensing edge) 18 3/4” 14 5/8” 12 5/8” 22” phantom 2000 specifications important safety information NOTE: The number of gate cycles using ONLY battery back-up power will vary depending on the weight of the gate, the gate length, the operating condition of the gate hardware, temperature and the amount of charge the batteries have at the beginning of the battery power only operation.

Residential Vehicular Gate Operator - A vehicular gate operator

(opener or system) intended for use in a home of one to four single family dwellings, or a garage or parking area associated therewith. CLASS II Commercial/General Access Vehicular Gate Operator - A vehicular gate operator (opener or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garages, retail store or other building servicing the general public. CLASS III Industrial/Limited Access Vehicular Gate Operator - A vehicular gate operator (opener or system) intended for uses in an industrial location, loading dock area or other location not intended to service the general public. CLASS IV Restricted Access Vehicular Gate Operator - A vehicular gate operator (opener or system) intended for use in a guarded industrial location or buildings such as airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. The same type of device shall not be utilized for both the primary and the secondary entrapment protection means. Use of a single device to cover both the opening and closing directions is in accordance with the requirement; however, a single device is not required to cover both directions. A combination of one Type B1 for one direction and one Type B2 for the other direction is the equivalent of one device for the purpose of complying with the requirements of either the primary or secondary entrapment protection areas. A - Inherent entrapment protection system. B1 - Provision for connection of a non-contact sensor (photoelectric sensor or the equivalent). B2 - Provision for connection of a contact sensor (edge device or the equivalent). C - Inherent adjustable clutch or pressure relief device. D - Provision for connection of an actuating device requiring continuous pressure to maintain opening or closing motion of the gate. E - An audio alarm. Gate Type Protection Type Class I & II Class III Class IV Swing Gate A, B1, B2, C, D A, C A, B1, B2, C A, B1, B2, C, D, E A, B1, B2, C, D, E A, B1, B2, C, D Secondary Primary SECURITY AUTHORIZED PERSONNEL ONLY ul 325 model classifications ul 325 required entrapment protection

A Install the gate operator only when:

1 The operator is appropriate for the construction of the gate and the usage Class of the gate, 2 All exposed pinch points are eliminated or guarded. B The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate. C The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. D The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate. E For gate operators utilizing Type D protection: 1 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving, 2 A gate operator shall additionally be provided with a placard that is marked in letters at least 1/4-in (6.4-mm) high with the word “WARNING” and the following statement or the equivalent: “Moving Gate Has Potential of Inflicting Injury or Death - Do Not Start Gate Unless Path is Clear”. 3 An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and 4 No other activation device shall be connected. F Controls intended for user activation must be located at least ten feet (10’) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. G The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start. H A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible. I For gate operators utilizing a non-contact sensor: 1 See instructions on the placement of non-contact sensors for each Type of application, 2 Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and 3 One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. J For a gate operator utilizing a contact sensor: 1 One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate. 2 One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. 3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate. 4 A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage. 5 A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or similar obstruction. A wireless device shall function under the intended end-use conditions. 6 One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge. 7 One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm). ul 325 compliant installation requirements

The operator is intended for use on a VEHICULAR swing gate ONLY. It is intended to be used WITH appropriate entrapment

protection safety devices and in-ground vehicle loop detection system. Pedestrians MUST use a separate entrance. The gate operator IS NOT intended to be used on a PEDESTRIAN gate. Entrapment Area In-Ground Loops: Help protect the gate operator from accidentally opening and/or closing on vehicles in the gate’s path. Sensing Edge: Helps protect the gate operator from accidentally opening and/or closing on vehicles in the gate’s path. Entrapment Protection Photocell: Helps guard against the opening gate from entrapment. Closing Gate Protection Photocell: Helps protect the gate operator from accidentally closing on vehicles in the gate’s closing path. Moving Gate Can Cause Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. Warning Signs: Should be installed on both sides of gate area and easily visible. intended use of swing gate operator

Read and understand this entire manual before installation. Check with the local building department prior to installing this gate

operator to comply with local building code requirements. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates should not open into public access areas. The gate must be properly installed and work freely in both directions prior to installation of the gate operator. POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Hinge Pivot Point Illustrations not to scale Gate Bracket Pivot Point Arm Pivot Point Longer than “E” Locked Position Long Arm Short Arm Shorter than “D” 15” Min Operator Pivot Point Concrete Pad 24” x 24” DO NOT allow arm to touch hood in gate’s OPEN position. TOO MUCH STRESS is put on the arm in this position during gate operation. Open Position Closed Position Outside Property Inside Property 2” Min 2” Gate Frame installation Gate Operator position A Should be at least 1/4 the gate length. B 15” minimum for open gate clearance (2” thick gate). C Distance “A” minus 17 inches (A - 17 = C). D & E Arm should be 90° from gate when OPEN and in the straight “locked” position when CLOSED. Measurement Guidelines A B C E D Hood Preferred arm position is 90° from open gate. See page 10 for arm position options and connection to gate.

Made in USA

POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery Battery IN Error F MAX BC-7 Battery Module Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity WARNING WARNING connect chassis to ground rod for lightning protection CLOSED LIMIT OPEN LIMIT 1/2 Use for VEHICULAR traffic ONLY. Pedestrians MUST use a separate entrance. Install appropriate entrapment protection safety devices for the OPENING direction and CLOSING direction of gate cycling. Install in-ground SAFETY and CENTER loops. Install a GROUNDING ROD within 10 ft of operator. An “Optional” EXIT loop can be installed if desired. installation Safety Loop Center Loop Exit Loop (Optional) 3.5” 3.5” 24”x 24” Pad 8”x 17” Conduit Area 8” 8” 6” Above Ground 24” Min OPENING Photocell Beam Height Just Above Gate Operator Input AC Power (Required) Illustration not to scale From Safety Loop CLOSING Photocell CLOSING Photocell Beam 21” High OPENING Photocell Beam In-Ground Loops CLOSING Photocell 24V/RS-485 (Required) & Optional Key Switch Ground Rod recommended Gate Operator layout Support Bar Support Bar Secure gate operator to concrete pad with four (4) 1/2” x 3” (min) sleeve anchors. Run wiring to GATE OPERATOR. Sensing Edge Mount on end of gate.

Check local building

codes in your area for depth of concrete before installation. 6” Above Ground Ground Level Secure gate operator to concrete pad with four (4) 1/2” x 3” (min) sleeve anchors. 19” Arm MUST be installed level. Concrete Depth Note: The heavier the gate, the deeper the concrete pad should be. At least two feet recommended for heavier gate. installation single Gate Operator • REQUIRED - AC input power wire to the GATE OPERATOR. • REQUIRED - 24VDC/RS-485/Optional Key Switch wires from CONTROL BOX to GATE OPERATOR. • OPENING cycle protection device wires (photocells) to the GATE OPERATOR. See page 14. • CLOSING cycle protection device wires (photocells) to the CONTROL BOX. See page 14. • In-ground loop wires to the CONTROL BOX. See page 15. Conduit Guidelines and Suggestions (See page 7) 1/2 “Optional” Input Power Note: 24VDC low voltage power wires can be run from a remote power supply (MAX Magic Box) to power the gate operator if desired. See page 11 for more information. Support Bar: See below Illustration not to scale The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. See “Gate Operator Position” on page 6 for operator position. Support Bar A support bar should be installed at the gate bracket height across the ENTIRE gate to keep the gate pickets from bending. YES YES NO NO Gate Bracket Support Bar Too High & Not Long Enough Support Bar 19”

The gates must be properly installed and work freely in both directions prior to the installation of the dual gate operators.

See “Gate Operator Position” on page 6 for operator positions. Each entrapment protection device MUST be connected to corresponding gate operator. Outside Property Inside Property to Secondary Operator to Secondary Operator to Primary Operator to Primary Operator POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Illustrations not to scale installation Photocell (OPENING Cycle ONLY) Photocell (OPENING Cycle ONLY) Sensing Edges Entrapment Area Entrapment Area Control Box RS-485/Optional Key Switch to Control Box Input Power Input Power Conduit • REQUIRED - Run AC input power wire to EACH gate operator. • REQUIRED - Run 24VDC/RS-485/Optional Key Switch wires from PRIMARY operator to the CONTROL BOX. • REQUIRED - Run RS-485/Optional Key Switch wires from SECONDARY operator to the CONTROL BOX. • Run UL 325 entrapment protection device conduits to EACH Corresponding GATE OPERATOR. (see below & page 14) • Run the CLOSING cycle protection device conduit (photocells) to the CONTROL BOX. (page 14) • Run in-ground loop wires to the CONTROL BOX. (page 15) dual Gate Operators 24VDC/RS-485/ Key Switch Primary Primary Secondary Secondary “Optional” Input Power Note: 24VDC low voltage power wires can be run from a remote power supply (MAX Magic Boxes) to power the gate operators if desired. See page 11 for more information. 19” Support Bars: See bottom of page 8. Arms MUST be installed level. Conduit Guidelines and Suggestions Illustration not to scale Check local building codes in your area for depth of concrete before installation. Secure EACH gate operator to concrete pad with four (4) 1/2” x 3” (min) sleeve anchors. Concrete Depth Note: The heavier the gates, the deeper the concrete pads should be. At least two feet recommended for heavier gates. 1/2 6” Above Ground

arm position options

Gates in Closed Position Gate in Opened Position Arms are NOT installed in LOCKED position. High Traffic Arm Option Retro-Fit Arm Option If a vehicle tries to push gates open, arms will give when NOT in the locked position and allow gates to move without damaging the gate operators. The tamper relay will be activated for a few seconds which will trigger a camera or alarm system if desired. When replacing an existing gate operator, the arm may not be able to conform to the preferred arm position (90° from gate in open position). The positions illustrated below can be acceptable as long as the gate operator cycles smoothly and there is NO gate hesitation when gate starts cycling in either direction. After you’re satisfied testing the arm in the FULL OPEN and FULL CLOSED positions, weld gate bracket and arm. Full Open Full Closed POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Illustrations not to scale Arm MUST be installed level. Preferred arm position is 90° from open gate. weld completely around arm tubing and gate bracket. Locked Position Gate Bracket Assembly Arm Elbow Assembly arm connection to gate Arm Re-Attach Arm to Operator: Limit Pin Limit Tabs Slot Release Handle Clamp Limit pin MUST fit into slot in bottom of release handle clamp directly under the arm when re-attaching arm to operator. 90° Gate in Opened Position 90°

A remote power supply is for installations where it is too costly or difficult to trench a 115/230 VAC power line to the operator

but instead run a low voltage power line to the operator. A MAX Magic Box Kit (sold separately) is required to remotely install the MAX PS-24 power supply. Install the MAX Magic Box near the 115 VAC or 230 VAC input AC power source, up to 1000 ft away from gate operator. Remove MAX PS-24 power supply from gate operator and place in MAX Magic Box. See page 19 for MAX Magic Box wiring instructions. NOTE: A MAX Magic Box kit is required for EACH gate operator when using dual gate operators. At MAX Magic Box Control Box (Matrix 1) Concrete Pad 24VDC/RS-485/ Optional Key Switch 24VDC Low Voltage Power Conduit Ground Level MAX PS-24 Power Supply Removed from Operator At Gate Operator optional remote power supply kit - max magic box installation Input Power To Operator 24 VDC 230V AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Select Input Voltage: 115VAC or 230VAC disconnect power before servicing unit WARNING WARNING HIGH HIGH VOLTAGE VOLTAGE ! warranty VOIDED if label is REMOVED Power/Solar In Connector Wire Nuts MAX Magic Box Kit Operator MAX Magic Box Near Power Source 115/230 VAC Power Source Control Box (Matrix 1) 115V AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery Battery IN Error F MAX BC-7 Battery Module Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity WARNING WARNING connect chassis to ground rod for lightning protection CLOSED LIMIT OPEN LIMIT Distance - See table below 2-Wires, 24VDC Low Voltage Power Low Voltage Input AC Power Conduit not supplied 24VDC Low Voltage Power Gate Weight Max Wire Distance - Wire Gauge 500 ft - 10AWG 2000 lbs 1000 ft - 8AWG

solar - Optional

Refer to Solar application guide. Solar Panel Electronics Box Operator Control Box MAX Solar Power Kit: MUST be used when using solar power. Sold separately. This OPTIONAL module replaces the MAX BC-7 Battery Module in the operator. It can be used when the operator is in a high traffic cycling area (Approximately 2000 cycles using only battery power). Sold separately. Solar Panel: must be mounted facing south. It must get full sunlight throughout the day, NO shadow obstructions. MAX Solar Kit Power/Solar In Connector Wire Nuts MAX Solar Power Kit Solar Panel Electronics Box Solar Panel 24 Volt OPTIONAL MAX BC-36 Phantom Battery Module POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery Battery IN Error F MAX BC-36 Phantom Battery Module MAX BC-36 Phantom Battery Module (36 Amp/Hr)

A minimum of two (2) WARNING SIGNS shall be installed,

one on each side of the gate where easily visible. Moving Gate Can Cause Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. Moving Gate Can Cause Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. Moving Gate Can Cause Serious Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operate the gate or play in the gate area. This entrance is for vehicles only. Pedestrians must use separate entrance. install warning signs

Install photocells to help protect against entrapment during the OPENING cycle of the gate (secondary entrapment protection).

Install photocells to help protect vehicles during the CLOSING cycle of the gate. Install sensing edge to help protect vehicles from a moving gate. See pages 17 & 25 for wiring instructions. Beam Height: 21” Normal 27.5” Max. Beam: 5” or LESS from CLOSED gate. Photocell (OPENING Cycle) Photocell (CLOSING Cycle) Photocell (CLOSING Cycle) Photocell (OPENING Cycle) Install just above gate operator. Entrapment Area Gate Open Gate Open Gate Closed Top View Side View If this dimension is less than 16”, then secondary entrapment protection is REQUIRED in this area. CLOSING Cycle NOTE: Additional CLOSING Cycle Photocells can be installed anywhere needed. Run all additional CLOSING Cycle photocell’s conduit to the CONTROL BOX. OPENING Cycle NOTE: Additional OPENING Cycle Photocells can be installed anywhere needed. Run all additional OPENING Cycle photocell’s conduit to the GATE OPERATOR. Dual Gate Operators NOTE: Run EACH OPENING Cycle Photocells conduit to each corresponding GATE OPERATOR. See page 9. Run OPENING Cycle photocell conduit to GATE OPERATOR. Illustrations not to scale installation entrapment protection Outside Property Inside Property Control Box Control Box Run CLOSING Cycle conduit to CONTROL BOX. SENSING EDGE Run wire to GATE OPERATOR. SENSING EDGE Mount on end of gate. Conduit

loops conduit to

CONTROL BOX. Center Loop Safety Loop Safety Loop Exit Loop 4 ft 4 ft 4 ft 4 ft 4 ft 4 ft 4 ft Control Box 1 1/2” Typical 1/4” Saw Cut Saw Cut Backer Rod Loop Wire Pavement Sealant Illustration not to scale Side View of Saw Cut Loop lead wires are twisted 6 twists per foot minimum inside conduit. Safety Loops Are placed on each side of the gate to prevent the gate from closing on a vehicle in it’s path. They will stop or reverse the cycling of the gate while a vehicle is in or near the gate’s pathway. Center Loop Will ONLY HOLD the gate in the Full Open Position when a vehicle is on the center loop. However, it WILL NOT stop or reverse the gate once it starts to close. Exit Loop Automatically opens the gate for exiting vehicles without having to use a radio transmitter (remote control). The exit loop can be placed a minimum of 4 feet away from the safety loop or far enough away from the gate so it has opened by the time the vehicle approaches it. installation in-ground loops Outside Property Inside Property Matrix 1 Wiring Safety loops need to be wired in series. MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE T Lead Wires SAFETY LOOP SAFETY LOOP EXIT LOOP CENTER LOOP Outside Property Inside Property EXIT CENTER SAFETY Refer to loop maunufacturer’s instructions to determine specific loop dimensions. It is recommended that a licenced installer perform this work. Install in-ground loops to help protect vehicles from a moving gate. See pages 25 & 29 for wiring instructions. 4 ft min.

UL ALARM 12V

ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING 12VDC GND 24VDC GND SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE 115V AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery Battery IN Error F MAX BC-7 Battery Module Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity WARNING WARNING connect chassis to ground rod for lightning protection Check with local building department prior to installing any permanent wiring on this gate operator. Make sure all wiring complies with local code requirements. MAX PS-24 Power Supply: AC power management for the AC input power to the gate operator. See pages 18, 19 & 23. Release Handle Clamp: Manually move the gate when handle is raised. See page 35. Audible Alarm: Sounds when there is a problem with cycling the gate. Push the alarm reset button on the control box to shut off alarm (see below). Alarm can sound every time operator is cycled using ONLY battery back-up power when turned ON, See page 32. 24VDC Brushless Motor (6 million cycles) MAX MC-100 Motor Controller: Manages UL entrapment protection devices and operator motor reversing ERD sensitivity adjustment. See pages 17, 21, 22 & 25. MAX BC-7 Battery Module: Battery Back-Up and DC power management for the gate operator. See page 17. Limit Tabs: Adjusts the OPEN and CLOSE gate positions. See page 34. Limit Switch Box: Contains the limit switches. Gate operator will NOT function when limit switch box is not connected. See page 34. Matrix 1: Manages control panel operations. Manages inputs/outputs, loops and reports problems with gate operator. See Matrix 1 Section starting on page 24. Alarm Reset Button: Push to shut off alarm and/or reset Matrix 1. See pages 25, 32 & 38. Optional Electronic Gate Open/Close Key Switch: Electronically move the gate open or closed by turning removable key in the key switch if connected to operator(s). See pages 22 & 40. Wiring operator Gate Operator System Overview 1 1 2 3 4 5 6 7 8 A B C 2 3 4 5 6 A B C 7 8 Gate Operator Control Box

Made in USA

BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery ON/OFF Battery TEST Battery Battery IN Error F MAX BC-7 Battery Module IMPORTANT connect to “BATTERY IN” before use ALARM PWR 24V - GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com Wiring operator 3 4 5 6 7 1 1 2 3 4 5 6 7 A B C D E F G H I J K L M A B C D E F G I K H J L M 2 BATTERY Plug: MUST be plugged into BATTERY IN port Before use. POWER/SOLAR IN Port: MAX PS-24 Power Supply connection. Battery Voltage LEDs: Show amount of battery power available. LEDs are always ON when using AC power. Test battery button must be pressed to show battery power when using battery power ONLY. ON/OFF Battery Button: IMPORTANT: Battery power automatically turns ON when MAX PS-24 Power Supply AC POWER Switch is turned ON. To turn OFF ALL POWER to operator: 1. Turn OFF AC POWER Switch on MAX PS-24 Power Supply. Battery power remains ON. 2. WAIT for 15 seconds. 3. Press and HOLD (approx. 5 seconds) the YELLOW ON/OFF BATTERY button until MAX BC-7 LEDs turn ON, then release button. LEDs will turn OFF. Replace Battery LED: Replace battery when lit. TEST Battery Button: Press to show amount of battery power available when using battery power ONLY (Battery voltage LEDs will light respectively). Battery IN Error LED: Lights when there is a battery connection problem. Make sure battery plug #1 is plugged into BATTERY IN port or there is no damaged or loose wires. MOTOR OVERLOAD LED: Excessive current being drawn by motor when lit. ERD LED: ERD sensor has been activated when lit. ERD Sensitivity Knob: 16 selectable sensitivity settings of ERD sensor. ERD Sensitivity LED: MAX sensitivity reached when lit. Jog LEFT/RIGHT Buttons: Push and HOLD buttons accordingly to move the gate (release the button to stop gate). WARNING: Avoid moving arm while using Jog buttons. INPUTS: Jog LT/RT: Connects to optional key switch on Control Box. GND: Low Voltage Common connection. Edge 1: Connects to a Sensing Edge. Multiple sensing edges can be connected. Edge 2: Connects to a second Sensing Edge. Multiple sensing edges can be connected. PHOTOCELL: Connects to a UL 325 Standard OPENING Cycle photocell ONLY. Multiple OPENING Cycle photocells can be connected. Matrix On Line LED: Gate operator is successfully communicating with Matrix 1 when lit. Limit SW On Line LED: Limit Switch Box is successfully communicating with MC-100 Motor Controller when lit. Edge 1 LED: Reversing Edge 1 input has been activated when lit. Edge 2 LED: Reversing Edge 2 input has been activated when lit. UL Entrap LED: Edge1/Edge2/Photocell input has been activated when lit. Photocell LED: Photocell input has been activated when lit. Power LED: Low voltage power is connected when lit. Edge 1 (N.O.) Edge 2 (N.O.) GND 24V RS-485 GND Sensing Edges To Matrix 1 Gate Operator System Overview continued MAX MC-100 Motor Controller MAX BC-7 Battery Module DUAL GATE OPERATORS NOTE: Connect EACH photocell/reverse edge to the corresponding gate operator. See page 9. OPENING Cycle Entrapment Photocells ONLY. 24V Power. Photocell (N.O.) GND GND 24V Optional Electronic Open/Close Key Switch, See page 22.

Made in USA

Wire input AC power wire to the MAX PS-24 power supply as shown. Choose either 115V or 230V setting on input AC power selector switch. NOTE: AC power wire is required for EACH gate operator when using dual gate operators. Chassis (Green) Neutral (White) Line (Black) Chassis (Green) Neutral (White) Line (Black) Single Phase 115VAC Only 115VAC Single Phase 230VAC Only 230VAC Input AC Power Options Operator MUST be Properly GROUNDED Input AC Power Selector Switch 7 Amp Fuse Set to 115V 115V 230V Set to 230V Select Input Voltage: 115VAC or 230VAC input ac power Wiring operator CAUTION: If power selector switch is set for 115V but input power is actually 230 V, 7 Amp Fuse will blow. MAX PS-24 Power Supply Power Terminal warranty VOIDED if label is REMOVED Proper grounding of this gate operator is a requirement for LIGHTNING PROTECTION in lightning prone areas. To be effective, ground connections should be made with a minimum 12 AWG, 600 volt insulated wire to a ground point within 10 feet of the gate operator. The ground point must be at an electrical panel, a metallic cold water pipe that runs in the earth, or a grounding rod. Ground Rod within 10 ft of operator WARNING WARNING connect chassis to ground rod for lightning protection Chassis Ground Chassis Ground Conduit Tunnel 115V AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery Battery IN Error F MAX BC-7 Battery Module Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity WARNING WARNING connect chassis to ground rod for lightning protection TWO Chassis Grounds are located inside either end of the conduit tunnel. IMPORTANT NOTE: Make sure there are NO exposed bare wires at the power terminal connection. NOTE: Consult city codes for AC line wiring. Beware of existing underground services. 115 OR 230VAC Power Wire CAUTION: MAKE SURE CIRCUIT BREAKER IS OFF BEFORE WIRING DO NOT TURN POWER ON AT THIS TIME. DANGER HIGH VOLTAGE!

IMPORTANT NOTE: Maximum Control’s

remote power supply technology does NOT utilize the battery power from the MAX BC-7 Battery Module during NORMAL gate operation. Battery power is reserved for back-up power ONLY when an AC power failure occurs. As a result, battery life is NOT shortened. This low voltage system can CONTINUOUSLY cycle the gate during NORMAL gate operation, perfect for high traffic gate applications. POWER/SOLAR IN Port POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery Battery IN Error F MAX BC-7 Battery Module POWER/SOLAR IN Connector (Included in kit). Connect Input AC Power wire (See page 18 for wiring) At Gate Operator Wiring operator IMPORTANT: MAX Magic Box and Gate Operator MUST EACH be Properly GROUNDED. Proper grounding is a requirement for LIGHTNING PROTECTION in lightning prone areas. To be effective, ground connections should be made with a minimum 12 AWG, 600 volt insulated wire to a ground point within 10 feet of the MAX Magic Box and gate operator. The ground point must be at an electrical panel, a metallic cold water pipe that runs in the earth, or a grounding rod. NOTE: Beware of existing underground services. optional remote power supply kit - max magic box MAX Magic Box MUST be Properly GROUNDED Pos + GND Polarity Matters! Ground Rod within 10 ft of Box NOTE: Consult city codes for AC line wiring. A MAX Magic Box Kit (sold separately) is required to remotely install the MAX PS-24 Power Supply from the gate operator. Remove MAX PS-24 power supply from gate operator and install in MAX Magic Box, plug in power supply to PS-24 connector. Wire input AC power to the MAX PS-24 Power Supply (See page 18 for wiring). Choose either 115V or 230V setting on input AC power selector switch. Run 24V low voltage wires (not included) from the MAX Magic Box connection and wire to POWER/SOLAR IN connector (Polarity Matters!). Plug connector into POWER/SOLAR IN port on the gate operator’s MAX BC-7 battery module. NOTE: A MAX Magic Box kit is required for EACH gate operator when using dual gate operators. Input Power To Operator 24 VDC At MAX Magic Box 230V AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Select Input Voltage: 115VAC or 230VAC disconnect power before servicing unit WARNING WARNING HIGH HIGH VOLTAGE VOLTAGE ! warranty VOIDED if label is REMOVED Input AC Power Power In From PS-24 Pos + GND 115 VAC or 230 VAC Input AC Power MAX PS-24 Power Supply removed from operator 24V Wires 10 AWG Minimum MAX BC-7 Battery Module Ground Input AC Power Selector Switch CAUTION: If power selector switch is set for 115V but input power is actually 230 V, 7 Amp Fuse will blow. CAUTION: MAKE SURE CIRCUIT BREAKER IS OFF BEFORE WIRING DANGER HIGH VOLTAGE! DO NOT TURN POWER ON AT THIS TIME. Low Voltage 24V Low Voltage Wire in Conduit PS-24 Connector

solar power connection - optional

Wiring operator Refer to Solar application guide. POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery ON/OFF Battery TEST Battery Battery IN Error F MAX BC-7 Battery Module IMPORTANT connect to “BATTERY IN” before use Max Solar Power Kit (Sold separately) Connect to POWER/SOLAR IN Connect to POWER/SOLAR IN To MAX Solar Power Kit NOTE: Cover solar panel from sunlight BEFORE wiring plug to solar panel to prevent a shock from occurring. Pos + Red GND Black Polarity Matters! The OPTIONAL MAX BC-36 Phantom Battery Module is for high traffic cycling areas (Approximately 2000 cycles using only battery power). A BC-36 phantom module is needed for each solar power kit used (One per gate operator when dual gate operators have been installed). It replaces the MAX BC-7 Battery module in the operator’s battery position (see page 43). Operator cables reconnect to the same plugs on the BC-36 as they did on the BC-7 battery module. STANDARD MAX BC-7 Battery Module (Approximately 450 cycles using only battery power) OPTIONAL MAX BC-36 Phantom Battery Module 115V AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity WARNING WARNING connect chassis to ground rod for lightning protection POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery Battery IN Error F MAX BC-36 Phantom Battery Module MAX BC-36 Phantom Battery Module (36 Amp/Hr)

UL ALARM 12V

ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL CLOSE COM GATE DISABLE PHOTOCE MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE SABLE MA GATE SP N CLA MIN ID PLUG ELL 24V GND 24V Wire to Power Matrix 1 NO 24V to Matrix 1 Connect 24V power wire from the Primary/Single MAX MC-100 motor controller to power Matrix 1. Connect (3) three RS-485 wires from the MAX MC-100 motor controller to the Matrix 1 - PRIMARY GATE. Connect (3) three RS-485 wires from the SECONDARY operator’s MAX MC-100 motor controller to the Matrix 1 - SEC GATE. DO NOT connect PWR 24V. Wiring operator operators to matrix 1 Unscrew MAX MC-100 motor controller from operator to gain access to RS-485 connector. Schematics on page 38 of manual shows where all plugs are located to re-install MAX MC-100 motor controller. 115V AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery PWR IN Error F MAX BC-7 Battery Module ALARM PWR 24V - GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity Primary/ Primary/ Single Single Operator Operator ALARM PWR 24V - GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com ALARM PWR 24V - GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com 22 AWG Min. 5-conductor twisted pair, shielded cable NOTE: Primary/Single operator closest to control box. 22 AWG Min. 3-conductor twisted pair, shielded cable Primary/Single Primary/Single Operator Operator Secondary Secondary Operator Operator Bi-Parting Gates Bi-Parting Gates Control Box Matrix 1 Primary/Single Secondary 5 Wires to Matrix 1 3 Wires to Matrix 1 3 Wires to Matrix 1 5 Wires to Matrix 1

22 AWG Min.

3-conductor twisted pair, shielded cable Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Max Sensitivity ALARM PWR 24V - GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com Primary MAX MC-100 Motor Controller The Optional Key Switch is independent of the Matrix 1 and allows the gate to be electronically moved open or closed by turning the removable key in either direction if you choose to connect the key switch. Connect (3) three wires from the Key Switch at the Control Box to the MAX MC-100 Motor Controller. NOTE: Each operator is specifically wired to the Optional Key Switch when installing dual gate operators if you choose to connect the key switch. (see illustrations). Wiring operator optional key switch to Operator(s) Optional Open/Close Key Switch Control Box Key Switch Primary/Single Secondary Key Switch Terminal 3 Wires to Key Switch 3 Wires to Key Switch Primary/Single Open LEFT PRIMARY SECONDARY OPEN RIGHT OPEN LEFT INSIDE Property OUTSIDE Property Primary/Single MAX MC-100 Motor Controller Secondary MAX MC-100 Motor Controller Primary/Single Open RIGHT OPEN RIGHT OPEN LEFT INSIDE Property PRIMARY SECONDARY OUTSIDE Property Open (Green) Gnd Close (White) INPUTS Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT INPUTS Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT Gnd Key Switch Terminal Primary/Single MAX MC-100 Motor Controller Secondary MAX MC-100 Motor Controller Open (Green) Gnd Close (White) INPUTS Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT INPUTS Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT Gnd ALARM PWR 24V - GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com Secondary MAX MC-100 Motor Controller Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity

PWR 24V -

GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity 230V AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Select Input Voltage: 115VAC or 230VAC warranty VOIDED if label is REMOVED disconnect power before servicing unit WARNING WARNING HIGH HIGH VOLTAGE VOLTAGE ! MAX PS-24 Power Supply POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery ON/OFF Battery TEST Battery Battery IN Error F MAX BC-7 Battery Module IMPORTANT connect to “BATTERY IN” before use 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE MAX BC-7 Battery Module Wiring operator turn on/off operator power Turn AC Power Switch ON A A B B C C D D E E F F G G H H I I J J K K To turn OFF ALL POWER: 1. Turn OFF AC POWER Switch on MAX PS-24 Power Supply. Battery power remains ON. 2. WAIT for 15 seconds. 3. Press and HOLD (approx. 5 seconds) the YELLOW ON/OFF BATTERY button until MAX BC-7 LEDs turn ON, then release button. LEDs will turn OFF. Battery power automatically turns ON. Operator should have Input AC power wired to PS-24, 24V & RS-485 wired between Matrix 1 and MC-100 and “Optional” Key Switch wired to MC-100. TURN POWER ON. Certain LEDs should normally turn ON accordingly: AC IN LED: Normal - Turns ON. Error - Not ON. Check AC power. 7 Amp Fuse blown. Replace fuse. Input AC selector switch MUST be set to CORRECT input AC power. POWER LED: Normal - Turns ON. Error - Not ON. Check POWER IN plug on back of MC-100. Matrix On-Line LED: Normal - Turns ON. Error - Not ON. Check RS-485 wiring to Matrix 1. Limit SW On-Line LED: Normal - Turns ON. Error - Not ON. Check LIMIT SWITCH plug. BATTERY VOLTAGE LEDs: Normal - 3 LEDs turn ON - Fully charged batteries. Batteries need charging - LEDs will turn on in sequence until batteries are fully charged. Batteries are NOT necessary when AC power is available. BATTERY IN ERROR LED: Normal - Not ON. Error - Turns ON. Battery not plugged in to BATTERY IN port. POWER LED: Normal - Turns ON. Error - Not ON. Check 24V wiring from MC-100 Primary/Single. Motor On-Line PRIMARY LED: Normal - Turns ON. Error - Not ON. Check RS-485 wiring to Primary/Single MC-100. Limit SW On-Line PRIMARY LED: Normal - Turns ON. PRIMARY GATE OPEN RIGHT OPEN LEFT LED: Normal - Turns ON either LED according to switch setting. Error - Not ON. Check LIMIT SWITCH plug on back of MC-100. BATTERY IN USE LED: Normal - Not ON. Error - Flashes on and off. Battery not plugged in to BATTERY IN port on BC-7 Battery Module. MAX PS-24 Power Supply MAX MC-100 Motor Controller Matrix 1 MAX BC-7 Battery Module 1 2 3 4 DO NOT CYCLE GATE OPERATOR AT THIS TIME

UL ALARM 12V

ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE OFF OFF ON ON Single Pass Anti-Tailgate Radio Safety Pause Mode 0 Gate in Motion Alarms ON OFF ON OFF ON OFF Mode 1 Mode 1 ON OFF Motion Alarm sounds before gate moves and continues until gate stops Motion Alarms OFF Beeper Alert sounds in Battery Back-Up Mode while gate is in motion Beeper Alert OFF Mode 0 When turned “ON”; After a vehicle clears the Safety Loop, a closing gate will PAUSE if a second vehicle attempts to tailgate. The second vehicle must then back off the safety loop for the gate to continue closing. A new radio signal will open the gate. When turned "ON" a moving gate will pause if a radio input signal is received. The next radio signal causes the gate to continue in the original direction. MADE IN USA WWW.Max.US.com Battery Back-Up Mode - Page 26 Primary Gate - Page 26 Maglock - Page 29 Gate Tamper - Page 30 In-Ground Loop Connection - Page 29 Anti Tailgate - Page 27 Plug-In Loop Detectors - Page 29 UL Entrapment LEDs - Page 30 Close Timer - Page 26 ID Plug & ID Plug Error LED - Page 30 UL Alarm/Alarm Reset Button - Page 32 Radio Power - Page 28 Partial Open - Page 31 OBD Port Black Box - Page 28 Selectable Gate Speed Control - Page 26 ERD & Motor Overload LEDs - Page 33 Gate Status - Page 32 Radio Relay - Page 28 Emergency Vehicle/Max Open Inputs - Page 30 Normal Opening Devices - Page 25 Close Photocell - Page 32 Operators Communication LEDs - Page 21 & 33 OPEN/STOP/CLOSE Connection - Page 32 Gate Disable - Page 31 Matrix 1 Power - Page 21 & 33 Battery in Use - Page 33 MATRIX 1 MATRIX 1 Back matrix 1 Overview matrix 1 1 2 3 Gate in Motion Alarms - Page 28 Single Pass Anti-Tailgate - Page 27 Radio Safety Pause - Page 28 A B C 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 1 2 3 4 8 17 16 24 23 25 26 22 20 21 19 A B C 18 12 10 10 11 9 5 6 7 13 14 15 matrix 1

UL ALARM 12V

ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE Power 12 VDC OR 24 VDC Radio Power 12 VDC OR 24 VDC Photocell Power Card Reader CLOSE Cycle Photocells ONLY. See page 14 & 32. IS NOT UL 325 entrapment protection type B1. OPEN Cycle Photocells ONLY. Separate power for Devices. Keypad Photo Cell (N.O.) Photocell (N.O.) Edge 1 (N.O.) Edge 2 (N.O.) 24V RS-485 RS-485 250 mA Max. Stop GND GND GND Key Switch Telephone Entry 3-Button Station See page 32. Additional Reset Button See page 32. Gate Disable Switch or Timer See page 31. Primary/Single Operator Connect to MC-100 motor controller. See pages 21 & 33. Optional Key Switch See page 22. Optional Control Box Key Switch See page 22. MC-100 Motor Controller See page 17 Secondary Operator Connect to MC-100 See pages 21 & 33. Radio Receivers See page 28. In-Ground Loops See page 29. Loop Detectors See page 29. Safety Loops Wired in series Emergency OPEN (Overrides gate disable switch) MAX OPEN (Overrides gate disable switch) Center Loop Safety Loop Safety Loop Exit Loop Gate Tamper: See page 30. 24V Power for Matrix 1 from Primary/Single operator ONLY. See pages 17 & 33. ID Plug: See page 30 ID Plug Error LED. See page 30 4-Wire Radio 3-Wire Radio ON OFF ON 1 2 3 4 5 6 7 8 5 = Optimum Sens. = Increase Sens. = Decrease Sens. DEFLECTOMETER POWER ON = Normal Power OFF= No Power LED INDICATORS DETECT ON = Detect OFF= No Detect 2 Hz Flash=Delay Timing SW1 SW2 Frequency ON ON = Low ON OFF = Medium-Low OFF ON = Medium-High OFF OFF = High SW4 SW5 Output B ON ON = Pulse on Entry ON OFF = B same as A OFF ON = Pulse on Exit OFF OFF = Loop Fault SW3 ON = Fail Secure OFF = Fail Safe SW6 ON = 2 Second Delay OFF = No Delay SW7 ON = Normal Presence OFF = Infinite Presence SW8 ON = Sensitivity Boost OFF = No Sensitivity Boost Loop Fault 1 Flash = Open Loop 2 Flashes= Shorted Loop 3 Flashes=25% change of Inductance Both LED’s Flashing= Current Loop Fault PWR LED Flashing= Previous Loop Fault EDI Tel: 480.968.6407 DEFLECTOMETER SENS RESET POWER DETECT EDI SENS LMA1800 OPTIONS 1 2 3 4 5 6 7 8 ON UL LED Indicators ONLY. See page 30. Control Box Alarm Reset Button Strobe Light See page 32 Emergency/Security Devices Security Device Security Device Normal Opening Devices Normal Opening Device Normal Opening Device GATE OPEN GATE CLOSED UL 325 Entrapment Protection Type B1 See page 14. Maglock Connection: Must be specifically wired, See page 29. Reverse Edges: See page 14. Connect to Edge 1 and/or Edge 2. UL 325 entrapment protection type B2. Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity matrix 1 PRESS to RESET Motion Sensor Security Camera Gate Status: See page 32. Dry Contact (N.O.) Dry Contact (N.O.) (N.O.) (N.O.) wiring Overview See page 30. Control Box matrix 1

The Gate Speed knob has 16 selectable settings to choose from. The

speed varies from approximately 11.5 sec to 20 sec depending on the weight and length of the specific gate. Make sure gate speed is appro- priate for the size and length of the gate. NOTE: The Auto Gate Sync feature provides synchronous opening and closing between bi-parting gates. OPEN RIGHT OPEN LEFT matrix 1 primary gate - open left / open right selectable gate speed control 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN 12VDC GND 24VDC GND MAX SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE CENTER EXIT CLOSE ID PLUG N/CLOSE CONTR CENTER SAFETY PRIMARY GAT A RY ACK-UP MODE LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 OPEN RIGHT OPEN LEFT PRIMARY GATE Set the Primary/single gate operator with Primary Gate setting. Secondary operator will automatically be set to the opposite opening direction as the primary gate operator when using dual gates. 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE CLOSE TIMER MAX MIN OFF MOTOR ON SWITCH ON-LINE TOCELL TRIKE ND YPAD / RDR D FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN MAX GATE SPEED STOP CLOSE MOTOR MOTION REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX The Close Timer has 16 selectable settings for automatic gate close time. Knob at OFF position: close timer OFF. 1st click clockwise - Knob at MIN position: 1/2 sec... 2nd click clockwise: 1 sec... 3rd click: 4 sec... 4th click: 8 sec... 5th click: 12 sec (4 sec increments for each successive click up to 60 sec MAX) NOTE: 1/2 sec MIN position is recommended for High Traffic areas. gate close timer MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLUG P CLOSE TIMER MAX MIN OFF LEAVE OPEN - The gate operator will continue to cycle the gate normally until the battery power can no longer cycle the gate. When this happens, the gate operator will open the gate and leave it in the OPEN position until power is restored. LEAVE CLOSED - The gate operator will continue to cycle the gate normally until the battery power can no longer cycle the gate. When this happens, the gate will close if not already in the CLOSE position, where it will remain until power is restored. Enough battery power is retained for a LIMITED time to operate emergency vehicle entry (Using opening devices connected to FIRE DEPT and/or MAX OPEN inputs to FULLY open gate). OPEN 1 TIME - The gate operator will automatically OPEN gate once and leave it in the OPEN position until power is restored. The Battery Back-Up Mode setting will determine how the gate operator will function during an AC power failure. Gate operator with a full battery charge should cycle a 2000 lbs gate (battery power ONLY) approximately 450 times. battery back-up mode 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE EXIT ANTI TAILGATE CLOSE TIME ID PLUG MATIC OPEN/C OFF ON MAX 12VDC GND 24VDC GND MIN OFF SAFETY DE OPEN 1 TIME AUT RIX 1 BATTERY BACK-UP MODE LEAVE OPEN LEAVE CLOSED OPEN 1 TIME FIRE DEPT/MAX OPEN Inputs INSIDE Property PRIMARY LED turns ON for MAX setting ONLY LED turns ON for MAX setting ONLY SECONDARY OUTSIDE Property

Turned OFF - Close timer will close the gate. If an in-ground safety or exit loop

gets activated during the close cycle, gate will REVERSE to the open position. Turned ON - (In-ground loops required) Gate will close after all the in-ground loops have been cleared no matter how long the close timer is set for. If an in-ground safety loop gets activated during the close cycle, gate will REVERSE to the open position. Turned ON - (In-ground loops required) Gate will close after all the in-ground loops have been cleared no matter how long the close timer is set for. When an in-ground safety loop gets activated during the close cycle, gate will PAUSE and NOT reopen. When loop is cleared, gate will continue to close preventing UNAUTHORIZED entry. anti tailgate Single pass anti-tailgate 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE MOTOR ON-LINE LIMIT SWITCH ON-LINE SAFETY ANTI TAILGATE OFF ON AUTHORIZED Vehicle UNAUTHORIZED Vehicle 1 2 When last Safety Loop is cleared, gate will close. NOTE: If a VALID open command is received at this point, gate will stop and reopen. Safety Loop gets activated and PAUSES the closing gate. Gate will NOT reopen. Vehicle MUST back up for loop to clear, then gate continues to close. NO unauthorized entry. NO VALID open command. OFF OFF ON ON Single Pass Anti-Tailgate Radio Safety Pause Mode 0 Gate in Motion Alarms ON OFF ON OFF ON OFF Mode 1 Mode 1 ON OFF Motion Alarm sounds before gate moves and continues until gate stops Motion Alarms OFF Beeper Alert sounds in Battery Back-Up Mode while gate is in motion Beeper Alert OFF Mode 0 When turned “ON”; After a vehicle clears the Safety Loop, a closing gate will PAUSE if a second vehicle attempts to tailgate. The second vehicle must then back off the safety loop for the gate to continue closing. A new radio signal will open the gate. When turned "ON" a moving gate will pause if a radio input signal is received. The next radio signal causes the gate to continue in the original direction. MADE IN USA WWW.Max.US.com OFF ON VALID open command was given. UNAUTHORIZED Vehicle Approaches NO VALID open command is given. Vehicle is attempting to activate safety loop before the gate’s close cycle is complete, expecting gate to reopen. SAFETY LOOP CENTER LOOP SAFETY LOOP INSIDE Property OUTSIDE Property CENTER LOOP SAFETY LOOP SAFETY LOOP MATRIX 1 Back - Gate Pauses - - Gate Pauses - LED stays ON when Anti Tailgate is ON

Turned ON - The radio transmitter (remote control) can PAUSE a MOVING

gate by pressing the remote button. Pressing the remote button again will cause the gate to CONTINUE in the SAME direction. This process can be repeated as many times as desired. Radio safety pause OFF OFF ON ON Single Pass Anti-Tailgate Radio Safety Pause Mode 0 Gate in Motion Alarms ON OFF ON OFF ON OFF Mode 1 Mode 1 ON OFF Motion Alarm sounds before gate moves and continues until gate stops Motion Alarms OFF Beeper Alert sounds in Battery Back-Up Mode while gate is in motion Beeper Alert OFF Mode 0 When turned “ON”; After a vehicle clears the Safety Loop, a closing gate will PAUSE if a second vehicle attempts to tailgate. The second vehicle must then back off the safety loop for the gate to continue closing. A new radio signal will open the gate. When turned "ON" a moving gate will pause if a radio input signal is received. The next radio signal causes the gate to continue in the original direction. MADE IN USA WWW.Max.US.com Mo Motion Alarms O OFF ON OFF Mode 1 Motion Alarm sounds before gate m larms OFF attery Back-Up Mode while gate clos Radio Safety Pause g gate ill if di OFF Mode 1 Beeper MATRIX 1 Back OFF ON MODE 0 - Turned ON - Alarm will sound BEFORE and DURING gate cycle to alert surrounding area. NOTE: A strobe light can be connected to UL ALARM connection that will flash ON and OFF when the alarm is sounding. See page 32. MODE 1 - Turned ON - Alarm will beep when using ONLY battery power DURING gate cycling. This brings to attention that only battery power is being used and NOT normal AC power. gate in motion alarms OFF OFF ON ON Single Pass Anti-Tailgate Radio Safety Pause Mode 0 Gate in Motion Alarms ON OFF ON OFF ON OFF Mode 1 Mode 1 ON OFF Motion Alarm sounds before gate moves and continues until gate stops Motion Alarms OFF Beeper Alert sounds in Battery Back-Up Mode while gate is in motion Beeper Alert OFF Mode 0 When turned “ON”; After a vehicle clears the Safety Loop, a closing gate will PAUSE if a second vehicle attempts to tailgate. The second vehicle must then back off the safety loop for the gate to continue closing. A new radio signal will open the gate. When turned "ON" a moving gate will pause if a radio input signal is received. The next radio signal causes the gate to continue in the original direction. MADE IN USA WWW.Max.US.com MATRIX 1 Back Mode 0 ON OFF ON OFF Mode 1 Connect a 3-wire or 4-wire radio receiver to Matrix 1. Choose 12V or 24V, 250 ma max. power. CLOSE TIMER ON - Each time the remote button is pressed during the Close Timer countdown (gate is open) causes the timer to reset and begin again. When close timer countdown is complete, gate will close. CLOSE TIMER OFF - Sequence when pressing remote button: Press One Time - gate OPENS . . . Press Again - gate STOPS . . . Press Again - gate CLOSES . . . Press Again - gate STOPS . . . Sequence repeats when button is pressed again. radio receiver MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLUG 24VD GND 12VDC GND 24VDC GND 4-Wire Radio 3-Wire Radio Receiver Input Removable Terminal On Board Diagnostics (OBD) port will download a simple .txt file to trouble- shoot gate operator errors and to view normal transaction logs. Plug a USB flash drive into port. LED will flash while file is downloading. When LED stops flashing, remove flash drive and plug it into any computer with an available USB port and simple text reader software (typical). The operator’s event history is stored as a simple .txt file. Contained in the file is a log of the most recent 1000 events. Quickly identify and diagnose a complex or intermittent problem. The file can even be e-mailed to the factory for on site diagnosis if necessary. The files will be stored as an ongoing event history of the transactions that occur at the gate operator. obd port black box MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE CLOSE POSITION RECORDER ID PLUG P O CE SAFETY 12VDC GND 24VDC GND USB Flash Drive OBD PORT BLACK BOX Choose 12 VDC OR 24 VDC (250 mA Max.) MIN MIN MAX MAX OFF UL ENTRAP 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING 12VDC GND 24VDC GND SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE Radio Position NOTE: Use a drain hole in bottom of control box to expose wire antenna of receiver. NOTE: See page 44 for more information about this unique feature.

UL ALARM 12V

ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE PRIMARY BATTERY 1 CLOSE TIMER MAX MIN PHOT OFF SAFETY matrix 1 Matrix 1 will accept third party loop detectors in the 3 ports. Each loop detector has a corresponding in-ground loop that must be connected for the loop system to operate (see below). Power down Matrix 1 BEFORE connecting loop detectors. Refer to your chosen loop detector’s instruction sheet for specific information about loop detector. Loop Detectors maglock Maglock MUST be connected as shown. MAGLOCK DELAY: You MUST select a time delay when using a maglock. Maglock power disengages 1.5 sec or 2 sec before gate starts opening. MAGLOCK LED (Monitors Maglock): ON - Locked OFF - Unlocked Flashing - Problem with Maglock MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE OPEN MAX GATE SPE STOP MOTOR MOTION MIN M EPT RADIO SIG. DIO GND CENTER EXIT ANTI TAILGATE UTOMATIC OPEN/CLOSE CONTROLS OFF ON EXIT CENTER Reno Loop Detector (Plug-In) Diablo Loop Detector (Plug-In) Connect desired loop detector to appropriate loop port Maglock Power Pos Neg Pos Neg Maglock SAFETY CENTER EXIT OPEN/CLOSE CONTROLS ON 1 2 3 4 5 6 7 8 5 = Optimum Sens. = Increase Sens. = Decrease Sens. DEFLECTOMETER POWER ON = Normal Power OFF= No Power LED INDICATORS DETECT ON = Detect OFF= No Detect 2 Hz Flash=Delay Timing SW1 SW2 Frequency ON ON = Low ON OFF = Medium-Low OFF ON = Medium-High OFF OFF = High SW4 SW5 Output B ON ON = Pulse on Entry ON OFF = B same as A OFF ON = Pulse on Exit OFF OFF = Loop Fault SW3 ON = Fail Secure OFF = Fail Safe SW6 ON = 2 Second Delay OFF = No Delay SW7 ON = Normal Presence OFF = Infinite Presence SW8 ON = Sensitivity Boost OFF = No Sensitivity Boost Loop Fault 1 Flash = Open Loop 2 Flashes= Shorted Loop 3 Flashes=25% change of Inductance Both LED’s Flashing= Current Loop Fault PWR LED Flashing= Previous Loop Fault EDI Tel: 480.968.6407 DEFLECTOMETER SENS RESET POWER DETECT EDI SENS LMA1800 OPTIONS 1 2 3 4 5 6 7 8 ON In-ground loop connection Connect each in-ground loop wires to the appropriate input. Lead wires should be twisted together 6 twists per foot minimum. See page 15 for in-ground loop installation. Safety loop wires must be wired in series. Each LED will light when the corresponding loop detector get activated by a vehicle passing over its in-ground loop. LEDs will flash when there is an error with the corresponding loop detector. MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE T Removable Terminal Lead Wires SAFETY LOOP SAFETY LOOP EXIT LOOP CENTER LOOP Outside Property Inside Property EXIT CENTER SAFETY Diablo Controls, Inc. Stuck in traffic for over 37 years! DSP-40 VEHICLE DETECTOR 7 to 30 Volts AC or DC 20 ma max. Indicators Steady indicates power Fast blink - Shorted loop Slow blink - Open loop Detect Indicator Green - Red - RESET POWER DETECT DSP - 40 Diablo Controls, Inc. 1 2 3 4 5 6 7 8 ON EXT= SW 8 SW 7 OFF OFF ON OFF ON ON OFF ON 0 SEC 2 SEC 5 SEC 10 SEC DLY= SW 6 SW 5 OFF OFF ON OFF ON ON OFF ON 0 SEC 2 SEC 5 SEC 10 SEC FREQ= SW 2 SW 1 ON ON OFF ON OFF OFF ON OFF LOW NORM MED HIGH BOOST SW 4 OFF ON ON OFF MODE SW 3 OFF ON FAIL SECURE FAIL SAFE VEHICLE DETECTOR MODEL H2 8-30 VDC LOW NORM HIGH 0 3 7 SENSITIVITY RENO RENO A&E POWER DETECT FAIL EDI Loop Detector (Plug-In) EDI Loop Detector Low Current Draw (Plug-In) ON 1 2 3 4 5 6 7 8 5 = Optimum Sens. = Increase Sens. = Decrease Sens. DEFLECTOMETER POWER ON = Normal Power OFF= No Power LED INDICATORS DETECT ON = Detect OFF= No Detect 2 Hz Flash=Delay Timing SW1 SW2 Frequency ON ON = Low ON OFF = Medium-Low OFF ON = Medium-High OFF OFF = High SW4 SW5 Output B ON ON = Pulse on Entry ON OFF = B same as A OFF ON = Pulse on Exit OFF OFF = Loop Fault SW3 ON = Fail Secure OFF = Fail Safe SW6 ON = 2 Second Delay OFF = No Delay SW7 ON = Normal Presence OFF = Infinite Presence SW8 ON = Sensitivity Boost OFF = No Sensitivity Boost Loop Fault 1 Flash = Open Loop 2 Flashes= Shorted Loop 3 Flashes=25% change of Inductance Both LED’s Flashing= Current Loop Fault PWR LED Flashing= Previous Loop Fault EDI Tel: 480.968.6407 DEFLECTOMETER SENS RESET POWER DETECT EDI SENS LMA1800 OPTIONS 1 2 3 4 5 6 7 8 ON OPTIONS ON 1 2 3 4 5 6 7 8 5 = Optimum Sens. = Increase Sens. = Decrease Sens. DEFLECTOMETER POWER ON = Normal Power OFF= No Power LED INDICATORS DETECT ON = Detect OFF= No Detect 2 Hz Flash=Delay Timing SW1 SW2 Frequency ON ON = Low ON OFF = Medium-Low OFF ON = Medium-High OFF OFF = High SW4 SW5 Output B ON ON = Pulse on Entry ON OFF = B same as A OFF ON = Pulse on Exit OFF OFF = Loop Fault SW3 ON = Fail Secure OFF = Fail Safe SW6 ON = 2 Second Delay OFF = No Delay SW7 ON = Normal Presence OFF = Infinite Presence SW8 ON = Sensitivity Boost OFF = No Sensitivity Boost Loop Fault 1 Flash = Open Loop 2 Flashes= Shorted Loop 3 Flashes=25% change of Inductance Both LED’s Flashing= Current Loop Fault PWR LED Flashing= Previous Loop Fault EDI Tel: 480.968.6407 DEFLECTOMETER SENS RESET POWER DETECT EDI SENS LMA1800-LP 1 2 3 4 5 6 7 8 ON Third party external loop detectors can be used if desired with the MAX External Loop Detector Cable Adapter. (1) One is included with the operator but more can be purchased if needed. External Loop Detector External Loop Detectors Plug-In Loop Detectors Wire to back of detector Plug-In Loop Detector Safety loops need to be wired in series. Power 15 VDC (Red) Loop Detect Output (White) Com, Gnd (Black) Power Terminal MAX External Loop Detector Cable Adapter MAG LOCK MAGLOCK DELAY OFF 2Sec 1.5Sec COM NC Tamper NO COM GND Tamper IN + + - - Power Terminal

UL ALARM 12V

ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF PARTIAL OPEN OBD PORT BLACK BOX REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE EX ANTI TAILGATE AU EDGE 2 ENTRAP ER 12 matrix 1 id plug AN ID Plug comes standard on Matrix 1. It identifies the type of gate operator and MUST be plugged in or the Matrix 1 WILL NOT function. ID PLUG ERROR LED: Will light when ID PLUG is missing. Low Profile Swing ID Plug Knox Box Key Switch ID PLUG ID PLUG ERROR LOW PROFILE SWING MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MAX 12VDC GND 24VDC GND MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE SAFETY CENTER EXIT ANTI TAILGATE AUTOMATIC OPEN/ Tam MAX GATE SP STOP CLOSE REVERSE SEN ND 24VDC GND ED MOTOR OVERLOAD NO LIMIT SWIT CLAM T O SIG. GND ID PLUG PARTIAL OPEN MOTOR MOTION UL entrapment LEDs UL ENTRAPMENT LEDs will indicate when a OPENING DIRECTION Photocell and/or Sensing Edge(s) have been activated. If alarm gets triggered, press reset button on control box to turn alarm off. NOTE: UL safety approved devices are wired to the MC-100 motor controllers ONLY. DO NOT wire them to the Matrix 1. REVERSE SENSITIVITY LED: Will light when the gate encounters an obstruction triggering the ERD sensor. PHOTOCELL EDGE 1 EDGE 2 UL ENTRAP REVERSE SENSITIVITY MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND OPEN STOP CLOSE COM GATE DISABLE ID PLUG 12VDC GND DC emergency vehicle/max open inputs FIRE DEPT lnput: Should be connected to a knox box device to allow the proper authorities to gain emergency access when necessary. The input will override the GATE DISABLE input and allow EMERGENCY personnel FULL 24/7 access. Gate fully opens. MAX OPEN Input: Can be connected to a key switch and used as an ADDITIONAL input from the FIRE DEPT input. The input will override the GATE DISABLE input and allow SECURITY personnel FULL 24/7 access. Gate fully opens. FIRE DEPT GND MAX OPEN GND Security Camera MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLUG PARTIAL OPEN CLOSE TIMER MAX PHOTOC MIN OFF SAFETY CENTER EXIT TAILGATE OFF ON EXIT GA Tamp Gate Tamper GATE TAMPER Tamper NO COM GND Tamper IN The GATE TAMPER can be used for various functions such as turning a warning light, siren or camera on when the gate is tampered with (Vandalized Gate). The gate operator defines a “Vandalized Gate” as UNAUTHORIZED movement of the gate. This can occur if the red release handle clamp is lifted and gate is manually moved from the closed position or the gate is forced open from the closed position without authorization. TAMPER NO/Com Relay: Connect a warning light, siren, camera or an existing alarm system to relay. TAMPER IN/GND Input: Connect a sensor device to input. When Tamper In/GND gets triggered, device that is wired to Tamper relay (NO/Com) will activate. Siren Warning Light Motion Sensor Power Power Existing Building Alarm System NOTE: See page 43 for more information about this unique feature.

UL ALARM 12V

ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE PEN STOP ER EXIT CENTER REVERSE SENSITIV OTOR OVERLOAD WITCH / PING MAX IN OFF ST 12VDC GND ELL DR gate disable GND GATE DISABLE ON OFF IMPORTANT: Limit switches MUST be learned BEFORE Partial Open can be recorded. To RECORD PARTIAL OPEN: 1. With gate in CLOSED position, press and release PARTIAL OPEN button to START recording. Blue LED starts flashing. 2. Press 3-button station OPEN button to start gate’s open cycle. 3. Press 3-button station STOP button when gate is in desired partial open position (Beyond center loop). 4. Press PARTIAL OPEN button AGAIN to STOP recording. Blue LED stops flashing, open position has been recorded. LED remains ON. To ERASE PARTIAL OPEN recording: Press and HOLD PARTIAL OPEN button for 5 sec. LED turns OFF. partial open 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MAX 12VDC GND 24VDC GND MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE OPEN CLAMP SLIP 24VDC GND SIG. ND OPEN STOP CLOSE POSITION RECORDER PARTIAL OPEN MOTOR MOTION CAUTION: Gates partial OPEN position MUST be outside the Center Loop when in-ground loops have been installed. CENTER LOOP NOTE: The FIRE DEPT and/or MAX OPEN connected devices will always FULLY open gates even when the partial open is being used. An ON/OFF switch or 7-Day timer devices can be connected to the GATE DISABLE input. When these devices are turned ON, they will DISABLE normal opening devices such as keypad, exit loop etc. The FIRE DEPT/ MAX OPEN and RADIO inputs will remain enabled when GATE DISABLE has been turned ON. This is useful when the gated area needs to be secured from ALL but emergency or authorized vehicle entry. Some examples are: Residential home vacation period or during closed hours of a business when no one can monitor the property. When GATE DISABLE is turned ON: The operator will beep for 3 minutes BEFORE arming itself. This allows time to turn ON GATE DISABLE and leave the property before it is armed. When FIRE DEPT/MAX OPEN gets activated: Gate opens and GATE TAMPER relay will activate immediately. When RADIO Input gets activated: Gate opens and GATE TAMPER relay will activate after 3 min. This allows time to turn OFF GATE DISABLE or disarm an existing building alarm system if connected. IMPORTANT: It is NOT recommended activating the GATE DISABLE device while persons are present inside the property. Enabled inputs when GATE DISABLE is turned ON. A gate can set to partially open by recording the PARTIAL OPEN gate cycle. LED will stay lit when PARTIAL OPEN is ON. NOTE: See page 44 for more information about this unique feature.

in Remote Location

Factory Wired Reset Button Strobe Light MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF OBD PORT BLACK BOX MOTOR MOTION REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLUG ERROR ENTRAP G OPEN STOP CLOSE TIVITY UL alarm / Alarm Reset button A UL ALARM (strobe light) can be connected. It will turn ON when the GATE IN MOTION - Mode 0 and/or Mode 1 are turned ON (see page 28). Press RESET BUTTON to turn OFF activated strobe light. Press RESET BUTTON to turn OFF an activated alarm. MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX CENTER MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE UL ALAR RESET GND CLOSE TIMER PARTIAL OPEN CENTER MAX MIN OFF SAFETY MAX POSITION RECORDER ID PLUG CL OBD PORT BLACK BOX MIN 12VDC STATUS gate status monitoring GATE STATUS LEDs will turn ON when gate is in the OPEN or CLOSED position. Connect a gate monitoring device to GATE STATUS relays to show if gate is in the OPEN or CLOSED position. OPEN/COM Relay: Activates momentarily (1 sec) when gate gets to the OPEN position. CLOSE/COM Relay: Activates when gate gets to the CLOSED position. open / stop / close Connection The OPEN/STOP/CLOSE inputs will allow a standard 4-wire 3-Button Station or an additional External RESET Button to be connected. Corresponding LEDs will light when each button is activated. OPEN COM CLOSE GATE STATUS GATE OPEN GATE CLOSED OPEN STOP STOP CLOSE Com Power GND GND N.O. Com MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE OPEN MAX GATE SPEED REVERSE MOTOR OVERL NO LIMIT SWITCH / CLAMP SLIPPING CLOSE TIME ON PARTIAL OPEN SAFETY PHOT GN STRIKE GND KEYPAD GND E DEPT ND MAX OPEN GND SIG. O GND UL ALARM 12V ALARM RET RESET GND OPEN STOP CLOSE COM GATE DISABLE 3-Button Station Additional External Reset Button PRESS to RESET closing photocell connection The PHOTOCELL input will allow a CLOSING DIRECTION PHOTOCELL to be connected. 12V or 24V power can be supplied for the photocells. NOTE: This input is NOT UL SAFETY PHOTOCELL. ALL UL inputs MUST be made at the MAX MC-100 motor controller on the gate operator. MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE PHOTOCELL GND 12V or 24V Photocells ID PLUG 24VD GND 12VDC GND 24VDC GND Choose 12 VDC OR 24 VDC (250 mA Max.) INSIDE Property CLOSING GATE DIRECTION OUTSIDE Property Additional CLOSING Cycle Photocells can be connected.

PWR 24V -

GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com Secondary Secondary MC-100 MC-100 ALARM PWR 24V - GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com Primary/Single Primary/Single MC-100 MC-100 ALARM PWR 24V - GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com Primary/Single Primary/Single MC-100 MC-100 matrix 1 MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND KEYPAD / RDR GND FIRE DEPT MAX OPEN RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE FIRE D MAX RADIO SI RADIO O MAX GATE SPEED NO LIM CLAMP S MIN MAX CLOSE TIME POSITION RECORDER ID PLUG PARTIAL OPEN OBD PORT ACK BOX MIN O SAFETY gate operators communication leds 24V power for matrix 1 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON MOTOR MOTION REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN GND 24VDC GND MAX LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC POWER GATE STATUS (+) GND (-) GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND PLUG MIN MAX OPEN STOP CLOSE MOTO REVERSE SENSITIVITY MOTOR OVERLOAD T SWITCH / LIPPING GATE STATUS 24V GND battery in use led BATTERY IN USE LED will light when operator is using ONLY battery back-up power. The GATE IN MOTION Alarm can be set up to sound alarm when operator is using ONLY battery power DURING gate cycling. This brings to attention that only battery power is being used and NOT normal AC power. See page 28. LED Flashing NOTE: BATTERY IN USE and POWER LEDs flash together when the battery is not plugged into the BATTERY IN port of the MAX BC-7 Battery Module. Make sure battery plug is correctly installed and there is no damaged or loose wires. PRIMARY/SINGLE operator to the PRIMARY GATE (+, GND, -). SECONDARY operator to the SEC GATE (+, GND, -). See page 21. LIMIT SWITCH ON-LINE LEDs: will light for each gate operator’s limit switch that the Matrix 1 is successfully communicating with. MOTOR ON-LINE LEDs: will light for each gate operator’s MC-100 Motor Controller that the Matrix 1 is successfully communicating with. Connect 24VDC POWER from PRIMARY/SINGLE operator ONLY. See page 21. POWER LED: Will light when 24V low voltage power is connected. NOTE: DO NOT power any external devices using this connection. This power is reserved for Matrix 1 ONLY. MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE OPEN STOP CLOSE CLOSE TIMER C CLOSE PARTIAL OPEN C REVERSE SENSITIVITY TOR OVERLOAD / MAX MIN OFF SAFETY GATE STATUS OTOR LIM SWITCH ON-LINE 24VDC GND DISAB POWER MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE BATTERY IN USE POWER motor motion leds REVERSE SENSITIVITY LED: Will light when the gate encounters an obstruction triggering the ERD sensor. MOTOR OVERLOAD LED: Will light when excessive current is being drawn by motor caused by damaged gate hardware or gate is too heavy. NO LIMIT SWITCH/CLAMP SLIPPING LED: Will light when either limit switch does NOT activate from it’s learned positions. NO LIMIT SWITCH/CLAMP SLIPPING LED: Will light when the release handle clamp is slipping on the output shaft. The learned gate OPEN and CLOSE positions will NOT be correct when the limit tabs keep changing position. MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE N STOP CLOSE CLOSE TIMER PARTIAL OPEN MOT CEN MAX MIN OFF SAFETY CLAMP OBD PORT BLACK BOX MIN 12VDC GND MAX REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING 24V

Made in USA

POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery PWR IN Error F MAX BC-7 Battery Module Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max The limit tabs need to be set BEFORE the gate can be cycled or DAMAGE could occur. Approximate OPEN and CLOSED limit tab positions. OPEN LED OPEN LED CLOSED Tab Activated Position CLOSED Tab Activated Position OPEN Tab Activated Position OPEN Tab Activated Position Push and HOLD the JOG LEFT or JOG RIGHT buttons accordingly on the MAX MC-100 motor controller to move the gate (release the button to stop gate). This allows gate to be moved back and fourth without leaving the operator to “fine tune” the open and close gate positions if desired. Adjustments open and close limits CLOSED LIMIT OPEN LIMIT Limit Switch Box OPEN Limit switch contact point. CLOSED Limit switch contact point. IMPORTANT: Manually Release arm and move the gate to the desired OPEN and CLOSED positions to adjust the limit tabs. Make sure power is ON. A r m O p e n i n g D ir e c ti o n A r m O p e n i n g D ir e c ti o n Arm Closed Position Arm Closed Position Arm Open Position Arm Open Position Open Limit Switch Closed Limit Switch CLOSED LED CLOSED LED Open LEFT R o ta te L i m it T a b u n ti l L E D l ig h ts CLOSED LIMIT OPEN LIMIT Arm in CLOSED position Operator Opens RIGHT ADJUST LIMITS: CLOSED LOSE LOSE LIMIT LIMIT LIMIT LIMIT LIMIT LIMIT LIMIT LED lights Limit Tab Screw 1. Move gate to OPEN position. 2. Loosen open limit tab screw. 3. Rotate open limit tab until open LED lights. 4. Tighten open limit tab screw. 5. Move gate to CLOSED position. 6. Loosen closed limit tab screw. 7. Rotate closed limit tab until closed LED lights. 8. Tighten closed limit tab screw. Cycle the gate OPEN and CLOSED after the limit tabs have been set AND the arm is SECURE. Operator will cycle slowly to LEARN the open and closed gate positions. After the operator learns the gate positions, it will cycle at the GATE SPEED selected for normal operation. Manually Release Arm “Fine Tune” Limits Adjustment IMPORTANT: Manually Secure Arm (see page 35) IMPORTANT: LEDs MUST light up when gate reaches OPEN and CLOSE positions or operator WILL NOT learn gate positions. If gate positions are not learned, gate cycling speed will remain slow during normal operation. EXAMPLE: LED Indicators IMPORTANT: Remove breather pin from gear reducer BEFORE cycling operator. WARNING: Avoid the moving arm while “Fine Tune” adjusting. Breather Pin CAUTION REMOVE BEFORE OPERATION

release handle clamp

Tighten the Adjustment bolt until desired result is achieved. The release handle clamp has been factory adjusted and SHOULD NOT need any adjustment. IMPORTANT: The red handle MUST BE FIRMLY secure in the HORIZONTAL position. NOTE: When limit tabs are already set and the release handle is put back in the secure position but the gate is NOT in the full open or close position, the operator will automatically re-align the gate’s open and close tabs. No readjustment is necessary. After Release Handle Clamp is in the SECURE HORIZONTAL position: Pull the arm. NO slippage should occur. If it does, readjust. Adjustment Bolt factory set bolt DO NOT adjust adjust bolt for firm grip Arm Adjustment: Re-Attach to Operator: Limit Pin Limit Tabs Slot Release Handle Clamp Limit pin MUST fit into slot in bottom of release handle clamp directly under the arm when reattaching arm to operator. IMPORTANT: The arm MUST NOT slip when the gate is cycling or the gate OPEN and CLOSE limit positions will NOT be LEARNED. Gate speed will remain slow if gate positions are NOT learned. Release Handle Clamp MUST be HORIZONTAL when FIRMLY secured. NO

Made in USA

POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery Battery IN Error F MAX BC-7 Battery Module Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Position gate half-way open and STOP gate. This gate position will put the most amount of resistance on the ERD sensor when gate cycles. Allow the gate to strike an immobile object while OPENING and CLOSING. The gate MUST reverse direction after striking the object. If it does not, increase the ERD Sensitivity. Repeat this process until the correct sensitivity is set. If alarm sounds while preforming this procedure, press alarm reset button on control box. NOTE: When solid gates are installed in unusually high wind areas, ERD sensor can be set to Min (position 16) to keep the gate cycling normally in such extreme conditions. CAUTION: Minimum sensitivity setting (position 16) results in gate exerting MAXIMUM force before reversing direction. Test ERD Sensitivity The Phantom 2000 is equipped with an ERD Sensor - Electronic Reversing Device (Type A) that functions as the primary entrapment protection according to UL 325 standards. The gate will reverse direction after encountering an obstruction in either the OPEN or CLOSE gate cycle. When the gate encounters an obstruction during the CLOSE cycle, it will reverse to the open position and PAUSE the gate. An input command (press remote button or exit loop) is needed BEFORE the gate will reset and close again. When the gate encounters an obstruction during the OPEN cycle, it will reverse approximately 6 inches and PAUSE the gate. An input command (press remote button or exit loop) is needed BEFORE the gate will reset and open again. For the ERD Sensitivity to function correctly: • THE RELEASE HANDLE CLAMP MUST NOT SLIP when the gate encounters an obstruction. • Limit switches must be learned BEFORE adjusting the ERD Sensitivity. Adjustments reverse sensor (erd) MC-100 motor controller Alarm Reset Button STOP Gate STOP Gate Half-way Half-way CLOSE gate. If ERD sensor triggers, reduce sensitivity. If sensor does NOT trigger, sensitivity is set correctly. CLOSE Gate CLOSE Gate 1 2 1. Turn knob clockwise until blue LED lights up (Max sensitivity reached, position 1) . . . 2. Turn knob counter-clock- wise to reduce sensitivity during testing as needed (LED will turn OFF at any position but 1). ERD Sensitivity Min Max Sensitivity ERD Sensitivity Min Max Sensitivity x sitiv ax ensitiv a Sensiti a Sensit M Sensi M Sens M Sen M S Adjust ERD Sensitivity ERD Sensitivity 1-Max 2 3 4 16-Min 15 14 13 12 16 selectable positions NO mechanical hard stop on knob LED lights up IMPORTANT: When satisfied with ERD adjustment, cycle the gate 3 or 4 times to make sure that the ERD sensor does not falsely trigger during normal gate operation. Readjust if this happens.

Maintenance and repair of the gate operator must be preformed by a qualified professional gate operator technician.

The following services need to be periodically performed: • Check and adjust the gate operator’s force, speed, and sensitivity. • Make sure all power (AC/DC) connections are corrosion free. • Check all batteries for proper voltage. • Check the incoming line voltage and confirm it is within 10% of its rating (115 or 230 volts). • Verify battery backup functionality by turning off the power source (115 VAC and 230 VAC). Restore power after testing. • Cycle gate system and lubricate with heavy-duty, high-performance lubricant where needed. • Test all contact and non-contact sensors, in-ground vehicle loop detectors, keypad, telephone entry system or any other access control devices that are used to control the gate operator. • Test the manual release feature. MAKE SURE END USER/HOME OWNER KNOWS HOW TO PROPERLY REMOVE GATE OPERATOR FROM SERVICE AND WHO TO CONTACT FOR PROFESSIONAL ASSISTANCE. Date Installed: Installer/Company Name: Phone Number: Operator Serial Number: Any repairs and modifications must be preformed by a qualified professional gate operator technician. If the gate or gate operator ever malfunctions, end user/home owner needs to immediately remove the gate operator from service (manually position gate (see manual release) in a desired prolonged position and turn ALL power OFF to the gate operator). End user/home owner must call a qualified professional gate operator technician for any repairs and modifications. The gate operator is virtually maintenance free to an end user/home owner, minimal maintenance is recommended to ensure reliable operation. End user/home owner: • Scheduled maintenance should be performed approximately every six months by a qualified professional gate operator technician, or when unusual noises are heard from the gate hinges and/or gate operator arm. • DO NOT remove the operator cover to perform any normal maintenance. • Lubricate gate hinges and gate operator arm periodically with heavy-duty, high-performance lubricant and clean up all excess lubricant. • Make sure there are no vehicles or pedestrians in the path of the gate while performing maintenance. • Make sure the person performing maintenance is the only person in control of all control devices in order to avoid possible involuntary activation of the gate operator. Gate operator MUST be removed from service while maintenance is performed. • Keep any water from landscape watering hoses or sprinkler systems away from the gate and gate operator area. • Keep the area around the gate and gate operator as clean as possible. • Keep any debris away from the gate’s swinging path. • Test periodically (use caution) all safety sensors, in-ground vehicle loop detectors, keypad, telephone entry system or any other access control devices that are used to control the gate operator. Make sure everything is working properly. • Solar panel must be cleaned periodically if solar power is being used. maintenance qualified gate operator technician end user / homeowner

Made in USA

BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA ALARM PWR 24V - GND - RS-485 (-) - RS-485 (+) - LIMIT SWITCH BATTERY PACK MOTOR INPUTS POWER IN MOTOR www.max.us.com MAX MC-100 Motor Controller Top View MAX MC-100 Motor Controller Front View Reset Button Input AC Power 115VAC or 230VAC Optional - Connects to Jog LT, Jog RT and GND Green White Black 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON-LINE LIMIT SWITCH ON-LINE (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE Optional Open/Close Key Switch phantom 2000 wiring schematic Maintenance 3-Pin 2-Pin 6-Pin 3-Pin 4-Pin 5-Pin “Optional” MAX Solar Power Kit Solar Panel 24V to POWER/SOLAR IN Solar Panel Electronics Box

for firm grip

Hood Factory Installed Lock Removable Key Unlock or unlatch hood and remove it. 2 Make sure ALL power is OFF to operator. 1 Pull red handle up and move gate. 3 maintenance manual gate release Arm WARNING WARNING NEVER grasp the arm to move gate! Pinch Point Arm ALWAYS grasp gate to move it. DO NOT Lift Arm OFF of Operator Optional Non-Lockable Latch OR

Insert key on control box, turn and HOLD (in either direction) to MOVE gate.

The OPTIONAL key switch can open or close the gate electronically if the switch has been wired to the gate operator. • The moving gate gets PUSHED by a moving VEHICLE. maintenance electronic gate open / close audible alarm CAUTION: Keep pedestrians and vehicles clear of the gate while it is moving. If the Alarm Sounds During Normal Gate Operation: When the gate encounters TWO consecutive obstructions before completing a gate cycle, the alarm will sound and the gate will PAUSE in the position where the second obstruction occurred. CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the alarm reset button on the control box to shut off the alarm and reset the gate. NOTE: Alarm will automatically shut-off after five minutes but will not allow gate to operate until the alarm reset button is pressed. Some reasons why the alarm sounds: Alarm Reset Button INSIDE Property Gate is Closing Moving Vehicle is Entering OUTSIDE Property • HINGES are TOO TIGHT or BROKEN, gate CANNOT move freely. • Gate is STUCK or BENT in an awkward position. • The gate operator tries to close the gate but gate gets CAUGHT on an object and cannot move. • A FOREIGN OBJECT is on the gate frame while the gate is moving. • The gate is TOO HEAVY.

replacement parts list

Item Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Camlock Assembly with cover and key Plastic Hood Hood Latch Bracket Output Clamp Assembly Operator cover with nameplate Swing arm T-Bar Output collar and rings Output Shaft 7Ahr Battery Module Limit Switch Assembly Power Supply Assembly 900:1 Double Gear Box DC Brushless Motor Motor Controller Assembly External Control Box Cabinet Matrix 1 Control Board Assembly Swing Arm Assembly Rotary Knob Actuator 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Maximum Controls LLC (“Manufacture”) warrants the original purchaser of this

product, for the purpose to which this product is originally installed, that the product is free from defect in materials and/or workmanship for a period of 8 years for the Brushless DC Motor and cover, 5 years for everything else with the exception of the batteries which are limited to a 1 year warranty. The performance of this product is dependent on compliance to the instructions, maintenance, operation, and testing clearly outlined in the user manual. Failure to comply completely with those instructions will void this warranty in its entirety. This warranty does not cover damage to the product caused by vandalism, water damage, direct hit lightning strike, or installation errors. This warranty does not include any labor charges that might be needed to troubleshoot, replace, or repair a problem. If, during the limited warranty period, one of the components exhibits a defect in material and/or workmanship, please call 949-699-0220 before dismantling the product. Shipping instructions and an RMA (Return Material Authorization) Number will be issued by the factory service center when contacted. Do not send any product in for service without an RMA number. Shipping charges to and from the factory service center for warranty repairs are the responsibility of the customer. Repair or replacement of any warranty items is made at the sole discretion of the Manufacturer. ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY AND SUITABILITY FOR A PARTICULAR PURPOSE, ARE LIMITED TO 8 YEARS FOR THE BRUSHLESS MOTOR DC AND COVER, 5 YEARS FOR EVERYTHING ELSE WITH THE EXCEPTION OF THE BATTERIES WHICH ARE 1 YEAR. NO IMPLIED WARRANTIES WILL EXTEND BEYOND THE WARRANTIES LISTED ABOVE. Some states do not allow limitations on how long an implied warranty last so this limitation might not apply to you. This Limited warranty does not cover any problems with or relating to, the gate, the gate hardware, including but not limited to hinges, rollers, brackets, entry devices etc. Any service call that determines the cause of a problem to be external to the product could result in a fee. Under no circumstances shall the manufacture be liable for consequential, incidental or special damages arising in connection with the use, or inability to use, this product. Under no circumstances will the Manufacture’s liability for breach of warranty, breach of contract, negligence or strict liability exceed the cost of the product covered other liability in connection with the sale of this product. phantom 2000 warranty

phantom options / unique Features

gate tamper feature “Like NO other Gate Operator in the World” The FIRE switch is turned ONLY if the GATE DISABLE has been turned ON. The GATE TAMPER feature will activate the relay when a number of security circumstances occur, making illegal entry almost impossible when the gate operator is connected to a existing building/home alarm system. The GATE TAMPER relay will activate when: Maximum Controls offers a MAX BC-36 Phantom Battery Module that replaces the standard MAX BC-7 Battery Module when more battery power ONLY will be used. This can be used with the OPTIONAL MAX solar power kit for the gate operator. Two 12 volt 36 Amp/Hr batteries supply plenty of power to operate up to 2000 gate cycles a day using only battery power. (your performance might vary) max BC-36 phantom battery module - optional The red release handle clamp is lifted and the gate is pushed open from the closed position without authorization. The gate is PHYSICALLY moved from the closed position with EXTREME force. 115V AC ON POWER OFF MAX PS-24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC-100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge 2 Edge 1 Edge 1 Edge 2 Photo Cell GND Jog RT Jog LT MOTOR OVERLOAD Motor Controller ERD Min Max Sensitivity WARNING WARNING connect chassis to ground rod for lightning protection POWER IN POWER/SOLAR IN BATTERY IN www.max.us.com Made in USA BATTERY PACK TO MOTOR CONTROLLER E 1/2 Battery Voltage Replace Battery TEST Battery ON/OFF Battery Battery IN Error F MAX BC-36 Phantom Battery Module

Gate disable feature

event history download This unique GATE DISABLE feature is useful when the gated area needs to be secured from ALL but emergency and/or autho- rized vehicle entry. Some examples are: This unique EVENT HISTORY feature has an On Board Diagnostics (OBD) port to download a simple .txt file to troubleshoot gate operator errors and to view normal transaction logs. This file will log intermittent problems with the gate operator that can be difficult to solve. This file can even be e-mailed to the factory from out in the field at the job site for additional technical support if necessary. The event history can store up to 1000 transactions. The GATE DISABLE feature will allow the FIRE DEPT/MAX and RADIO inputs to operate but nothing else. It helps with some major security problems that can occur when no one is available to monitor the property. “Like NO other Gate Operator in the World” • Residential home vacation period. • During closed hours of a business. GATE DISABLE prevents breaking into a keypad box and trying to trigger the wires to get the gate to open. GATE DISABLE prevents trying to trigger the exit loop to get the gate to open. IMPORTANT: It is NOT recommended activating GATE DISABLE while persons are present inside the property. Event type clarificaon: INFO: informaonal message only WARNING: unusual event but doesn't cause system malfuncon ERROR: abnormal event, could cause system malfuncon ENTRAP: entrapment detecon event Event Report: Fri 07/11/2014 10:59:41 INFO : Cycle Counter Fri 07/11/2014 10:59:41 ENTRAP : SEC_MC: First ERD Detected Fri 07/11/2014 10:59:37 INFO : Radio Input Deacvated Fri 07/11/2014 10:59:36 INFO : Radio Input Acvated Fri 07/11/2014 10:58:54 INFO : PRI_MC: Fully Open Posion Learned Fri 07/11/2014 10:58:53 INFO : SEC_MC: Fully Open Posion Learned Fri 07/11/2014 10:57:40 INFO : PRI_CIO: Communicaon Established Fri 07/11/2014 10:57:38 ENTRAP : PRI_MC: Photo Cell Deacvated Fri 07/11/2014 10:57:34 ENTRAP : PRI_MC: Photo Cell Acvated Fri 07/11/2014 10:57:21 INFO : Radio Input Deacvated Fri 07/11/2014 10:57:21 INFO : Radio Input Acvated Fri 07/11/2014 10:56:46 WARNING: PRI_MC: Tamper Reported Fri 07/11/2014 10:56:36 INFO : SEC_MC: Fully Open Posion Unknown Fri 07/11/2014 10:56:36 INFO : PRI_MC: Fully Open Posion Unknown Fri 07/11/2014 10:56:36 WARNING: PRI_MC: Tamper Reported Fri 07/11/2014 10:56:33 ENTRAP : PRI_MC: Photo Cell Deacvated Fri 07/11/2014 10:56:33 ENTRAP : PRI_MC: Photo Cell Acvated Fri 07/11/2014 10:56:33 ENTRAP : PRI_MC: Photo Cell Deacvated Fri 07/11/2014 10:56:33 ENTRAP : PRI_MC: Photo Cell Acvated Event History Text Document Sample USB Flash Drive MOTOR ON-LINE LIMIT SWITCH ON-LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN/CLOSE CONTROLS BATTERY BACK-UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH / CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1.5Sec COM NC BATTERY IN USE POWER GATE STATUS (+) GND (-) PRIMARY GATE (+) GND (-) SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD / RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG. RADIO GND OPEN STOP CLOSE COM GATE DISABLE N RECORDER OPEN MAX STOP CLOSE UL ALARM 12V ALARM RET IN US LE SWITCH ON-LINE OBD PORT BLACK BOX phantom options / unique Features EXIT LOOP Metal Plate

Maximum Controls LLC.

27211 Burbank Foothill Ranch, Ca 92610 Tel: (949) 699-0220 www.max.us.com 4009963 High Traffic Commercial Brushless DC Low Profile Swing Gate Operator Made in USA CONFORMS TO UL STD 325 UL CLASS - I, II, III, IV CERTIFIED TO CAN/CSA STD C22.2 NO. 247 Max Phantom 2000 Version 8.12.14