Maximum Controls Max Phantom 2000 Installation And Owner's Manual
Read Online
Read the Maximum Controls Max Phantom 2000 Installation And Owner's Manual online using the built-in PDF viewer.
Text of the manual
MAX Phantom 2000
Installation and Owners Manual
www.max.us.com
4009963
High Traffic Commercial
Brushless DC Low Profile
Swing Gate Operator
Made in USA
CONFORMS TO UL STD 325
UL CLASS - I, II, III, IV
CERTIFIED TO CAN/CSA STD
C22.2 NO. 247
© 2014 Maximum Controls LLC.
All rights reserved. No part of this manual may be reproduced in any
means: graphics, electronics or mechanical, including photocopying
without the expressed written permission of the publisher. Materials
components and specifications are subject to change without notice.
Phantom 2000 Specifications
Important Safety Information
UL 325 Model Classifications
UL 325 Required Entrapment Protection
UL 325 Compliant Installation Requirements
Intended Use of Swing Gate Operator
Installation
Gate Operator Position
Recommended Gate Operator Layout
Single Gate Operator
Dual Gate Operators
Arm Position Options
Arm Connection to Gate
Optional Remote Power Supply Kit - MAX Magic Box
Solar Optional
Install Warning Signs
Entrapment Protection
In-Ground Loops
Wiring operator
Gate Operator System Overview
Input AC Power
Optional Remote Power Supply Kit - MAX Magic Box
Solar Power Connection - Optional
Operators to Matrix 1
Optional Key Switch to Operator(s)
Turn ON / OFF Operator Power
matrix 1
Matrix 1 Overview
Wiring Overview
Primary Gate - Open Left / Open Right
Close Timer
Selectable Gate Speed Control
Battery Back-Up Mode
Anti-Tailgate
Single Pass Anti-Tailgate
Radio Receiver
Radio Safety Pause
Gate in Motion Alarms
OBD Port Black Box
Maglock
Loop Detectors
In-Ground Loop Connection
ID Plug
Gate Tamper
UL Entrapment LEDs
Emergency Vehicle / Max Open Inputs
Gate Disable
Partial Open
UL Alarm / Alarm Reset Button
Gate Status Monitoring
OPEN / STOP / CLOSE Connection
CLOSING Photocell Connection
Gate Operators Communication LEDs
24V Power for Matrix 1
Battery in Use LED
Motor Motion LEDs
Table of contents
2
2
3
3
4
5
6
7
8
9
10
10
11
12
13
14
15
16-17
18
19
20
21
22
23
24
25
26
26
26
26
27
27
28
28
28
28
29
29
29
30
30
30
30
31
31
32
32
32
32
33
33
33
33
Adjustments
Open and Close Limits
Release Handle Clamp
Reverse Sensor (ERD)
Maintenance
Qualified gate operator technician
End user/Home owner
Phantom 2000 Wiring Schematics
Manual Release
Electronic Gate Open / Close
Audible Alarm
Replacement Parts List
Warranty
Phantom options / unique features
Gate Tamper Feature
36 Amp/Hr Phantom Battery Module - Optional
Gate Disable Feature
Event History Download
37
37
38
39
40
40
41
42
43
43
44
44
34
35
36
WARNING – To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the
non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the
gate operator properly can increase the risk of injury or death.
5. Use the emergency release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate
hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. SAVE THESE INSTRUCTIONS
UL 325 Class of Operation - Class I, II, III, IV
Gate Type - Vehicular Swing Gate
Max Gate Weight / Length - 2000lbs @ 15 ft or 1500 lbs @ 20 ft
90° Opening Time - 16 selectable speeds from approximately 11.5 sec to 20 sec depending on the weight and length of gate.
Cycles per Hour AC Input Power - Continuous
Battery Back-Up Cycles (Batteries fully charged):
- BC-7 Battery Module-7 Amp/Hr Batteries, approximately 450 cycles
- BC-36 Phantom Battery Module-36 Amp/Hr Batteries, approximately 2000 cycles
Input AC Power - Switchable: 115VAC or 230VAC single phase
Motor - 24VDC Brushless (equivalent to 1 HP AC motor)
Operating Temperature - -4°F to 158°F (-20°C to 70°C)
Entrapment Protection:
- UL 325 Type A Inherent (ERD sensor)
- Input for UL 325 Type B1 (photocell) and B2 (sensing edge)
18 3/4”
14 5/8”
12 5/8”
22”
phantom 2000 specifications
important safety information
NOTE: The number of gate cycles using ONLY battery back-up power will vary
depending on the weight of the gate, the gate length, the operating condition of the gate
hardware, temperature and the amount of charge the batteries have at the beginning of
the battery power only operation.
Residential Vehicular Gate Operator - A vehicular gate operator
(opener or system) intended for use in a home of one to four
single family dwellings, or a garage or parking area associated
therewith.
CLASS II
Commercial/General Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for use in
a commercial location or building such as a multi-family
housing unit (five or more single family units) hotel, garages,
retail store or other building servicing the general public.
CLASS III
Industrial/Limited Access Vehicular Gate Operator - A
vehicular gate operator (opener or system) intended for uses
in an industrial location, loading dock area or other location
not intended to service the general public.
CLASS IV
Restricted Access Vehicular Gate Operator - A vehicular gate
operator (opener or system) intended for use in a guarded
industrial location or buildings such as airport security area or
other restricted access locations not servicing the general
public, in which unauthorized access is prevented via
supervision by security personnel.
The same type of device shall not be utilized for both the primary and the secondary entrapment protection means. Use of a single device to
cover both the opening and closing directions is in accordance with the requirement; however, a single device is not required to cover both
directions. A combination of one Type B1 for one direction and one Type B2 for the other direction is the equivalent of one device for the
purpose of complying with the requirements of either the primary or secondary entrapment protection areas.
A - Inherent entrapment protection system.
B1 - Provision for connection of a non-contact sensor
(photoelectric sensor or the equivalent).
B2 - Provision for connection of a contact sensor
(edge device or the equivalent).
C - Inherent adjustable clutch or pressure relief device.
D - Provision for connection of an actuating device
requiring continuous pressure to maintain opening
or closing motion of the gate.
E - An audio alarm.
Gate Type
Protection Type
Class I & II
Class III
Class IV
Swing Gate
A, B1, B2, C, D
A, C
A, B1, B2, C
A, B1, B2, C, D, E
A, B1, B2, C, D, E
A, B1, B2, C, D
Secondary
Primary
SECURITY
AUTHORIZED
PERSONNEL
ONLY
ul 325 model classifications
ul 325 required entrapment protection
A Install the gate operator only when:
1 The operator is appropriate for the construction of the gate and the usage Class of the gate,
2 All exposed pinch points are eliminated or guarded.
B The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access
opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons
will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
C The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when
opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
D The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.
E For gate operators utilizing Type D protection:
1 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving,
2 A gate operator shall additionally be provided with a placard that is marked in letters at least 1/4-in (6.4-mm) high with
the word “WARNING” and the following statement or the equivalent: “Moving Gate Has Potential of Inflicting Injury or
Death - Do Not Start Gate Unless Path is Clear”.
3 An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and
4 No other activation device shall be connected.
F Controls intended for user activation must be located at least ten feet (10’) away from any moving part of the gate and where
the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily
accessible controls shall have a security feature to prevent unauthorized use.
G The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause
the operator to start.
H A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
I For gate operators utilizing a non-contact sensor:
1 See instructions on the placement of non-contact sensors for each Type of application,
2 Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is
still moving, and
3 One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the
perimeter reachable by a moving gate or barrier.
J For a gate operator utilizing a contact sensor:
1 One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading
edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate.
2 One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
4 A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and
the gate operator is not subjected to mechanical damage.
5 A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection
functions shall be located where the transmission of the signals are not obstructed or impeded by building structures
natural landscaping or similar obstruction. A wireless device shall function under the intended end-use conditions.
6 One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the
bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or
more contact sensors shall be located on the bottom edge.
7 One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
ul 325 compliant
installation requirements
The operator is intended for use on a VEHICULAR swing gate ONLY. It is intended to be used WITH appropriate entrapment
protection safety devices and in-ground vehicle loop detection system.
Pedestrians MUST use a separate entrance.
The gate operator IS NOT intended to be
used on a PEDESTRIAN gate.
Entrapment Area
In-Ground Loops:
Help protect the gate
operator from accidentally
opening and/or closing on
vehicles in the gate’s path.
Sensing Edge: Helps
protect the gate operator
from accidentally opening
and/or closing on vehicles
in the gate’s path.
Entrapment Protection Photocell:
Helps guard against the opening
gate from entrapment.
Closing Gate Protection Photocell: Helps protect the gate operator
from accidentally closing on vehicles in the gate’s closing path.
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Warning Signs: Should be installed
on both sides of gate area and
easily visible.
intended use of
swing gate operator
Read and understand this entire manual before installation. Check with the local building department prior to installing this gate
operator to comply with local building code requirements. The gate must be installed in a location so that enough clearance is
supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates
should not open into public access areas.
The gate must be properly installed and work freely in both directions prior to installation of the gate operator.
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Hinge Pivot Point
Illustrations not to scale
Gate Bracket Pivot Point
Arm
Pivot
Point
Longer
than “E”
Locked Position
Long Arm
Short Arm
Shorter
than “D”
15” Min
Operator
Pivot
Point
Concrete Pad
24” x 24”
DO NOT allow arm to touch
hood in gate’s OPEN position.
TOO MUCH STRESS is put on
the arm in this position during
gate operation.
Open Position
Closed Position
Outside Property
Inside Property
2” Min
2” Gate Frame
installation
Gate Operator position
A Should be at least 1/4 the gate length.
B 15” minimum for open gate clearance (2” thick gate).
C Distance “A” minus 17 inches (A - 17 = C).
D & E Arm should be 90° from gate when OPEN
and in the straight “locked” position when CLOSED.
Measurement Guidelines
A
B
C
E
D
Hood
Preferred arm position is 90°
from open gate. See page 10
for arm position options and
connection to gate.
Made in USA
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
Battery IN
Error
F
MAX BC-7
Battery Module
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
WARNING
WARNING
connect chassis
to ground rod for
lightning protection
CLOSED
LIMIT
OPEN
LIMIT
1/2
Use for VEHICULAR traffic ONLY. Pedestrians MUST use a separate entrance.
Install appropriate entrapment protection safety devices for the OPENING
direction and CLOSING direction of gate cycling. Install in-ground SAFETY
and CENTER loops. Install a GROUNDING ROD within 10 ft of
operator. An “Optional” EXIT loop can be installed if desired.
installation
Safety Loop
Center Loop
Exit Loop
(Optional)
3.5”
3.5”
24”x 24” Pad
8”x 17”
Conduit
Area
8”
8”
6”
Above
Ground
24”
Min
OPENING Photocell
Beam
Height
Just
Above
Gate
Operator
Input AC Power (Required)
Illustration not to scale
From Safety Loop
CLOSING Photocell
CLOSING
Photocell Beam
21” High
OPENING Photocell Beam
In-Ground Loops
CLOSING Photocell
24V/RS-485
(Required)
& Optional
Key Switch
Ground
Rod
recommended Gate Operator layout
Support Bar
Support Bar
Secure gate operator
to concrete pad with
four (4) 1/2” x 3” (min)
sleeve anchors.
Run wiring to
GATE OPERATOR.
Sensing Edge
Mount on end of gate.
Check local building
codes in your area for
depth of concrete
before installation.
6” Above Ground
Ground Level
Secure gate operator
to concrete pad with
four (4) 1/2” x 3”
(min) sleeve anchors.
19”
Arm MUST be installed level.
Concrete Depth Note: The heavier the gate, the deeper the concrete
pad should be. At least two feet recommended for heavier gate.
installation
single Gate Operator
• REQUIRED - AC input power wire to the GATE OPERATOR.
• REQUIRED - 24VDC/RS-485/Optional Key Switch wires from CONTROL BOX to GATE OPERATOR.
• OPENING cycle protection device wires (photocells) to the GATE OPERATOR. See page 14.
• CLOSING cycle protection device wires (photocells) to the CONTROL BOX. See page 14.
• In-ground loop wires to the CONTROL BOX. See page 15.
Conduit Guidelines and Suggestions (See page 7)
1/2
“Optional” Input Power Note:
24VDC low voltage power wires can be run
from a remote power supply (MAX Magic
Box) to power the gate operator if desired.
See page 11 for more information.
Support Bar: See below
Illustration not to scale
The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
See “Gate Operator Position” on page 6 for operator position.
Support Bar
A support bar should be installed at the gate bracket height across the ENTIRE gate to keep the gate pickets from bending.
YES
YES
NO
NO
Gate Bracket
Support Bar Too High & Not Long Enough
Support Bar
19”
The gates must be properly installed and work freely in both directions prior to the installation of the dual gate operators.
See “Gate Operator Position” on page 6 for operator positions.
Each entrapment protection device MUST be connected to corresponding gate operator.
Outside Property
Inside Property
to Secondary Operator
to Secondary Operator
to Primary Operator
to Primary Operator
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Illustrations not to scale
installation
Photocell
(OPENING Cycle
ONLY)
Photocell
(OPENING Cycle
ONLY)
Sensing Edges
Entrapment Area
Entrapment Area
Control Box
RS-485/Optional Key Switch to Control Box
Input
Power
Input
Power
Conduit
• REQUIRED - Run AC input power wire to EACH gate operator.
• REQUIRED - Run 24VDC/RS-485/Optional Key Switch wires from PRIMARY operator to the CONTROL BOX.
• REQUIRED - Run RS-485/Optional Key Switch wires from SECONDARY operator to the CONTROL BOX.
• Run UL 325 entrapment protection device conduits to EACH Corresponding GATE OPERATOR. (see below & page 14)
• Run the CLOSING cycle protection device conduit (photocells) to the CONTROL BOX. (page 14)
• Run in-ground loop wires to the CONTROL BOX. (page 15)
dual Gate Operators
24VDC/RS-485/
Key Switch
Primary
Primary
Secondary
Secondary
“Optional” Input Power Note:
24VDC low voltage power wires can be run from a remote
power supply (MAX Magic Boxes) to power the gate
operators if desired. See page 11 for more information.
19”
Support Bars: See bottom of page 8.
Arms MUST be installed level.
Conduit Guidelines and Suggestions
Illustration not to scale
Check local building codes in your area for
depth of concrete before installation.
Secure EACH gate
operator to concrete
pad with four (4)
1/2” x 3” (min)
sleeve anchors.
Concrete Depth Note: The heavier the gates, the deeper the concrete
pads should be. At least two feet recommended for heavier gates.
1/2
6” Above
Ground
arm position options
Gates in Closed Position
Gate in Opened Position
Arms are NOT installed in LOCKED position.
High Traffic Arm Option
Retro-Fit Arm Option
If a vehicle tries to push gates
open, arms will give when NOT
in the locked position and allow
gates to move without damaging
the gate operators.
The tamper relay will be
activated for a few seconds
which will trigger a camera or
alarm system if desired.
When replacing an existing gate operator, the arm may not be able
to conform to the preferred arm position (90° from gate in open
position). The positions illustrated below can be acceptable as long
as the gate operator cycles smoothly and there is NO gate hesitation
when gate starts cycling in either direction.
After you’re satisfied testing the arm in the FULL OPEN and FULL CLOSED positions, weld gate bracket and arm.
Full Open
Full Closed
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Illustrations not to scale
Arm MUST be installed level.
Preferred arm position
is 90° from open gate.
weld completely around arm tubing and gate bracket.
Locked Position
Gate Bracket
Assembly
Arm Elbow
Assembly
arm connection to gate
Arm
Re-Attach Arm to Operator:
Limit Pin
Limit Tabs
Slot
Release Handle Clamp
Limit pin MUST fit into slot in
bottom of release handle clamp
directly under the arm when
re-attaching arm to operator.
90°
Gate in Opened Position
90°
A remote power supply is for installations where it is too costly or difficult to trench a 115/230 VAC power line to the operator
but instead run a low voltage power line to the operator. A MAX Magic Box Kit (sold separately) is required to remotely install
the MAX PS-24 power supply.
Install the MAX Magic Box near the 115 VAC or 230 VAC input AC power source, up to 1000 ft away from gate operator.
Remove MAX PS-24 power supply from gate operator and place in MAX Magic Box. See page 19 for MAX Magic Box wiring
instructions.
NOTE: A MAX Magic Box kit is required for EACH gate operator when using dual gate operators.
At MAX Magic Box
Control Box
(Matrix 1)
Concrete Pad
24VDC/RS-485/
Optional Key Switch
24VDC Low Voltage Power
Conduit
Ground Level
MAX PS-24
Power Supply
Removed from
Operator
At Gate
Operator
optional remote power supply kit - max magic box
installation
Input Power
To Operator
24 VDC
230V
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Select Input Voltage:
115VAC or 230VAC
disconnect
power before
servicing unit
WARNING
WARNING
HIGH
HIGH
VOLTAGE
VOLTAGE
!
warranty
VOIDED
if label is
REMOVED
Power/Solar In
Connector
Wire
Nuts
MAX
Magic
Box Kit
Operator
MAX Magic Box
Near Power Source
115/230 VAC Power Source
Control Box
(Matrix 1)
115V
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
Battery IN
Error
F
MAX BC-7
Battery Module
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
WARNING
WARNING
connect chassis
to ground rod for
lightning protection
CLOSED
LIMIT
OPEN
LIMIT
Distance - See table below
2-Wires, 24VDC Low Voltage Power
Low Voltage
Input AC
Power
Conduit
not supplied
24VDC Low
Voltage
Power
Gate Weight
Max Wire Distance - Wire Gauge
500 ft - 10AWG
2000 lbs
1000 ft - 8AWG
solar - Optional
Refer to Solar application guide.
Solar Panel
Electronics
Box
Operator
Control Box
MAX Solar Power Kit: MUST be used
when using solar power. Sold separately.
This OPTIONAL module replaces the MAX
BC-7 Battery Module in the operator. It can
be used when the operator is in a high traffic
cycling area (Approximately 2000 cycles
using only battery power). Sold separately.
Solar Panel: must be mounted facing
south. It must get full sunlight throughout
the day, NO shadow obstructions.
MAX Solar Kit
Power/Solar In
Connector
Wire
Nuts
MAX
Solar
Power
Kit
Solar Panel
Electronics
Box
Solar Panel
24 Volt
OPTIONAL
MAX BC-36 Phantom
Battery Module
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
Battery IN
Error
F
MAX BC-36
Phantom
Battery Module
MAX BC-36 Phantom
Battery Module
(36 Amp/Hr)
A minimum of two (2) WARNING SIGNS shall be installed,
one on each side of the gate where easily visible.
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
install warning signs
Install photocells to help protect against entrapment during the OPENING cycle of the gate (secondary entrapment protection).
Install photocells to help protect vehicles during the CLOSING cycle of the gate.
Install sensing edge to help protect vehicles from a moving gate. See pages 17 & 25 for wiring instructions.
Beam Height:
21” Normal
27.5” Max.
Beam: 5” or LESS from CLOSED gate.
Photocell
(OPENING Cycle)
Photocell (CLOSING Cycle)
Photocell (CLOSING Cycle)
Photocell (OPENING Cycle)
Install just above gate operator.
Entrapment
Area
Gate Open
Gate Open
Gate Closed
Top View
Side View
If this dimension is less
than 16”, then secondary
entrapment protection is
REQUIRED in this area.
CLOSING Cycle NOTE: Additional CLOSING Cycle Photocells
can be installed anywhere needed. Run all additional CLOSING
Cycle photocell’s conduit to the CONTROL BOX.
OPENING Cycle NOTE: Additional OPENING Cycle Photocells
can be installed anywhere needed. Run all additional
OPENING Cycle photocell’s conduit to the GATE OPERATOR.
Dual Gate Operators NOTE: Run
EACH OPENING Cycle Photocells
conduit to each corresponding
GATE OPERATOR. See page 9.
Run OPENING Cycle
photocell conduit to
GATE OPERATOR.
Illustrations not to scale
installation
entrapment protection
Outside Property
Inside Property
Control Box
Control Box
Run CLOSING Cycle conduit to CONTROL BOX.
SENSING EDGE
Run wire to
GATE OPERATOR.
SENSING EDGE
Mount on end of gate.
Conduit
loops conduit to
CONTROL BOX.
Center
Loop
Safety
Loop
Safety
Loop
Exit
Loop
4 ft
4 ft
4 ft
4 ft
4 ft
4 ft
4 ft
Control Box
1 1/2”
Typical
1/4” Saw Cut
Saw Cut
Backer Rod
Loop Wire
Pavement
Sealant
Illustration not to scale
Side View of
Saw Cut
Loop lead wires are
twisted 6 twists per
foot minimum inside
conduit.
Safety Loops
Are placed on each side of the gate to prevent
the gate from closing on a vehicle in it’s path.
They will stop or reverse the cycling of the
gate while a vehicle is in or near the gate’s
pathway.
Center Loop
Will ONLY HOLD the gate in the Full Open
Position when a vehicle is on the center loop.
However, it WILL NOT stop or reverse the
gate once it starts to close.
Exit Loop
Automatically opens the gate for exiting
vehicles without having to use a radio
transmitter (remote control). The exit loop
can be placed a minimum of 4 feet away from
the safety loop or far enough away from the
gate so it has opened by the time the vehicle
approaches it.
installation
in-ground loops
Outside Property
Inside Property
Matrix 1 Wiring
Safety loops need
to be wired in series.
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
T
Lead Wires
SAFETY LOOP
SAFETY LOOP
EXIT LOOP
CENTER LOOP
Outside Property
Inside Property
EXIT
CENTER
SAFETY
Refer to loop maunufacturer’s
instructions to determine specific
loop dimensions.
It is recommended that a
licenced installer perform
this work.
Install in-ground loops to help
protect vehicles from a moving
gate. See pages 25 & 29 for
wiring instructions.
4 ft min.
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
12VDC
GND
24VDC
GND
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
115V
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
Battery IN
Error
F
MAX BC-7
Battery Module
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
WARNING
WARNING
connect chassis
to ground rod for
lightning protection
Check with local building department prior to installing any permanent wiring on this gate operator. Make sure all wiring
complies with local code requirements.
MAX PS-24 Power Supply: AC power management for the
AC input power to the gate operator. See pages 18, 19 & 23.
Release Handle Clamp: Manually move the gate when
handle is raised. See page 35.
Audible Alarm: Sounds when there is a problem with cycling
the gate. Push the alarm reset button on the control box to
shut off alarm (see below). Alarm can sound every time
operator is cycled using ONLY battery back-up power when
turned ON, See page 32.
24VDC Brushless Motor (6 million cycles)
MAX MC-100 Motor Controller: Manages UL entrapment
protection devices and operator motor reversing ERD
sensitivity adjustment. See pages 17, 21, 22 & 25.
MAX BC-7 Battery Module: Battery Back-Up and DC power
management for the gate operator. See page 17.
Limit Tabs: Adjusts the OPEN and CLOSE gate positions.
See page 34.
Limit Switch Box: Contains the limit switches. Gate operator
will NOT function when limit switch box is not connected.
See page 34.
Matrix 1: Manages control panel operations. Manages
inputs/outputs, loops and reports problems with gate
operator. See Matrix 1 Section starting on page 24.
Alarm Reset Button: Push to shut off alarm and/or reset
Matrix 1. See pages 25, 32 & 38.
Optional Electronic Gate Open/Close Key Switch:
Electronically move the gate open or closed by turning
removable key in the key switch if connected to operator(s).
See pages 22 & 40.
Wiring operator
Gate Operator System Overview
1
1
2
3
4
5
6
7
8
A
B
C
2
3
4
5
6
A
B
C
7
8
Gate Operator
Control Box
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
ON/OFF
Battery
TEST
Battery
Battery IN
Error
F
MAX BC-7
Battery Module
IMPORTANT
connect to
“BATTERY IN”
before use
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
Wiring operator
3
4
5
6
7
1
1
2
3
4
5
6
7
A
B
C
D
E
F
G
H
I
J
K
L
M
A
B
C
D
E
F
G
I
K
H
J
L
M
2
BATTERY Plug: MUST be plugged into BATTERY IN port Before use.
POWER/SOLAR IN Port: MAX PS-24 Power Supply connection.
Battery Voltage LEDs: Show amount of battery power available.
LEDs are always ON when using AC power. Test battery button must be
pressed to show battery power when using battery power ONLY.
ON/OFF Battery Button:
IMPORTANT: Battery power automatically turns ON when MAX PS-24 Power
Supply AC POWER Switch is turned ON.
To turn OFF ALL POWER to operator:
1. Turn OFF AC POWER Switch on MAX PS-24 Power Supply.
Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the YELLOW ON/OFF BATTERY
button until MAX BC-7 LEDs turn ON, then release button.
LEDs will turn OFF.
Replace Battery LED: Replace battery when lit.
TEST Battery Button: Press to show amount of battery power available when
using battery power ONLY (Battery voltage LEDs will light respectively).
Battery IN Error LED: Lights when there is a battery connection problem.
Make sure battery plug #1 is plugged into BATTERY IN port or there is no
damaged or loose wires.
MOTOR OVERLOAD LED: Excessive current being drawn by motor when lit.
ERD LED: ERD sensor has been activated when lit.
ERD Sensitivity Knob: 16 selectable sensitivity settings of ERD sensor.
ERD Sensitivity LED: MAX sensitivity reached when lit.
Jog LEFT/RIGHT Buttons:
Push and HOLD buttons accordingly to move the gate (release the button to
stop gate). WARNING: Avoid moving arm while using Jog buttons.
INPUTS:
Jog LT/RT: Connects to optional key switch on Control Box.
GND: Low Voltage Common connection.
Edge 1: Connects to a Sensing Edge. Multiple sensing edges can be
connected.
Edge 2: Connects to a second Sensing Edge. Multiple sensing edges can be
connected.
PHOTOCELL: Connects to a UL 325 Standard OPENING Cycle photocell
ONLY. Multiple OPENING Cycle photocells can be connected.
Matrix On Line LED: Gate operator is successfully communicating with
Matrix 1 when lit.
Limit SW On Line LED: Limit Switch Box is successfully communicating
with MC-100 Motor Controller when lit.
Edge 1 LED: Reversing Edge 1 input has been activated when lit.
Edge 2 LED: Reversing Edge 2 input has been activated when lit.
UL Entrap LED: Edge1/Edge2/Photocell input has been activated when lit.
Photocell LED: Photocell input has been activated when lit.
Power LED: Low voltage power is connected when lit.
Edge 1
(N.O.)
Edge 2
(N.O.)
GND
24V
RS-485
GND
Sensing Edges
To Matrix 1
Gate Operator System Overview continued
MAX MC-100 Motor Controller
MAX BC-7 Battery Module
DUAL GATE OPERATORS NOTE: Connect EACH photocell/reverse
edge to the corresponding gate operator. See page 9.
OPENING Cycle
Entrapment
Photocells
ONLY.
24V
Power.
Photocell (N.O.)
GND
GND
24V
Optional Electronic
Open/Close
Key Switch,
See page 22.
Made in USA
Wire input AC power wire to the MAX PS-24 power supply as shown.
Choose either 115V or 230V setting on input AC power selector switch.
NOTE: AC power wire is required for EACH gate operator
when using dual gate operators.
Chassis (Green)
Neutral (White)
Line (Black)
Chassis (Green)
Neutral (White)
Line (Black)
Single Phase 115VAC Only
115VAC
Single Phase 230VAC Only
230VAC
Input AC Power Options
Operator MUST be Properly GROUNDED
Input AC Power
Selector Switch
7 Amp Fuse
Set to 115V
115V
230V
Set to 230V
Select Input Voltage:
115VAC or 230VAC
input ac power
Wiring operator
CAUTION: If power
selector switch is set
for 115V but input
power is actually 230 V,
7 Amp Fuse will blow.
MAX PS-24 Power Supply
Power Terminal
warranty
VOIDED
if label is
REMOVED
Proper grounding of this gate operator is a
requirement for LIGHTNING PROTECTION in
lightning prone areas. To be effective, ground
connections should be made with a minimum
12 AWG, 600 volt insulated wire to a ground
point within 10 feet of the gate operator. The
ground point must be at an electrical panel, a metallic cold water pipe that
runs in the earth, or a grounding rod.
Ground Rod
within 10 ft
of operator
WARNING
WARNING
connect chassis
to ground rod for
lightning protection
Chassis Ground
Chassis
Ground
Conduit Tunnel
115V
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
Battery IN
Error
F
MAX BC-7
Battery Module
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
WARNING
WARNING
connect chassis
to ground rod for
lightning protection
TWO Chassis
Grounds are located
inside either end of
the conduit tunnel.
IMPORTANT NOTE: Make sure there are NO exposed
bare wires at the power terminal connection.
NOTE: Consult city codes for AC line wiring.
Beware of existing underground services.
115 OR 230VAC
Power Wire
CAUTION: MAKE SURE CIRCUIT
BREAKER IS OFF BEFORE WIRING
DO NOT TURN POWER
ON AT THIS TIME.
DANGER
HIGH VOLTAGE!
IMPORTANT NOTE: Maximum Control’s
remote power supply technology does NOT
utilize the battery power from the MAX BC-7 Battery
Module during NORMAL gate operation. Battery power is
reserved for back-up power ONLY when an AC power failure
occurs. As a result, battery life is NOT shortened.
This low voltage system can CONTINUOUSLY cycle the gate during
NORMAL gate operation, perfect for high traffic gate applications.
POWER/SOLAR IN
Port
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
Battery IN
Error
F
MAX BC-7
Battery Module
POWER/SOLAR IN
Connector
(Included in kit).
Connect Input
AC Power wire
(See page 18 for
wiring)
At Gate Operator
Wiring operator
IMPORTANT: MAX Magic Box and Gate
Operator MUST EACH be Properly GROUNDED.
Proper grounding is a requirement for
LIGHTNING PROTECTION in lightning prone
areas. To be effective, ground connections
should be made with a minimum 12 AWG, 600
volt insulated wire to a ground point within 10
feet of the MAX Magic Box and gate operator.
The ground point must be at an electrical panel,
a metallic cold water pipe that runs in the earth,
or a grounding rod.
NOTE: Beware of existing underground
services.
optional remote power supply kit - max magic box
MAX Magic Box MUST
be Properly GROUNDED
Pos +
GND
Polarity Matters!
Ground Rod
within 10 ft
of Box
NOTE: Consult city codes
for AC line wiring.
A MAX Magic Box Kit (sold separately) is required to remotely install the MAX PS-24 Power Supply from the gate operator.
Remove MAX PS-24 power supply from gate operator and install in MAX Magic Box, plug in power supply to PS-24 connector.
Wire input AC power to the MAX PS-24 Power Supply (See page 18 for wiring).
Choose either 115V or 230V setting on input AC power selector switch. Run 24V low voltage wires (not included) from the MAX
Magic Box connection and wire to POWER/SOLAR IN connector (Polarity Matters!). Plug connector into POWER/SOLAR IN
port on the gate operator’s MAX BC-7 battery module.
NOTE: A MAX Magic Box kit is required for EACH gate operator
when using dual gate operators.
Input Power
To Operator
24 VDC
At MAX Magic Box
230V
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Select Input Voltage:
115VAC or 230VAC
disconnect
power before
servicing unit
WARNING
WARNING
HIGH
HIGH
VOLTAGE
VOLTAGE
!
warranty
VOIDED
if label is
REMOVED
Input AC Power
Power In
From
PS-24
Pos +
GND
115 VAC or
230 VAC
Input AC Power
MAX PS-24 Power Supply
removed from operator
24V
Wires
10 AWG
Minimum
MAX BC-7
Battery Module
Ground
Input AC Power Selector Switch
CAUTION: If power selector switch is
set for 115V but input power is actually
230 V, 7 Amp Fuse will blow.
CAUTION: MAKE SURE CIRCUIT
BREAKER IS OFF BEFORE WIRING
DANGER
HIGH VOLTAGE!
DO NOT TURN POWER
ON AT THIS TIME.
Low Voltage
24V Low Voltage Wire in Conduit
PS-24
Connector
solar power connection - optional
Wiring operator
Refer to Solar application guide.
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
ON/OFF
Battery
TEST
Battery
Battery IN
Error
F
MAX BC-7
Battery Module
IMPORTANT
connect to
“BATTERY IN”
before use
Max Solar
Power Kit
(Sold separately)
Connect to
POWER/SOLAR
IN
Connect to
POWER/SOLAR
IN
To MAX Solar
Power Kit
NOTE: Cover solar panel from
sunlight BEFORE wiring plug to
solar panel to prevent a shock
from occurring.
Pos + Red
GND Black
Polarity Matters!
The OPTIONAL MAX BC-36 Phantom Battery Module is for high
traffic cycling areas (Approximately 2000 cycles using only
battery power). A BC-36 phantom module is needed for each
solar power kit used (One per gate operator when dual gate
operators have been installed).
It replaces the MAX BC-7 Battery module in the operator’s battery
position (see page 43). Operator cables reconnect to the same
plugs on the BC-36 as they did on the BC-7 battery module.
STANDARD MAX BC-7 Battery Module
(Approximately 450 cycles using only battery power)
OPTIONAL MAX BC-36 Phantom Battery Module
115V
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
WARNING
WARNING
connect chassis
to ground rod for
lightning protection
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
Battery IN
Error
F
MAX BC-36
Phantom
Battery Module
MAX BC-36 Phantom
Battery Module
(36 Amp/Hr)
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
CLOSE
COM
GATE DISABLE
PHOTOCE
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
SABLE
MA
GATE SP
N
CLA
MIN
ID
PLUG
ELL
24V
GND
24V Wire to Power Matrix 1
NO 24V
to Matrix 1
Connect 24V power wire from the
Primary/Single MAX MC-100 motor
controller to power Matrix 1.
Connect (3) three RS-485 wires from
the MAX MC-100 motor controller to
the Matrix 1 - PRIMARY GATE.
Connect (3) three RS-485 wires from the
SECONDARY operator’s MAX MC-100 motor
controller to the Matrix 1 - SEC GATE.
DO NOT connect PWR 24V.
Wiring operator
operators to matrix 1
Unscrew MAX MC-100 motor controller from operator
to gain access to RS-485 connector. Schematics on page
38 of manual shows where all plugs are located to
re-install MAX MC-100 motor controller.
115V
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
PWR IN
Error
F
MAX BC-7
Battery Module
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS POWER IN
MOTOR
www.max.us.com
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
Primary/
Primary/
Single
Single
Operator
Operator
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS POWER IN MOTOR
www.max.us.com
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
22 AWG Min.
5-conductor
twisted pair,
shielded cable
NOTE: Primary/Single operator
closest to control box.
22 AWG Min. 3-conductor
twisted pair, shielded cable
Primary/Single
Primary/Single
Operator
Operator
Secondary
Secondary
Operator
Operator
Bi-Parting Gates
Bi-Parting Gates
Control Box
Matrix 1
Primary/Single
Secondary
5 Wires to Matrix 1
3 Wires to Matrix 1
3 Wires to Matrix 1
5 Wires to Matrix 1
22 AWG Min.
3-conductor
twisted pair,
shielded cable
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Max
Sensitivity
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
Primary
MAX MC-100
Motor Controller
The Optional Key Switch is independent of the Matrix 1
and allows the gate to be electronically moved open or
closed by turning the removable key in either direction if
you choose to connect the key switch.
Connect (3) three wires from the Key Switch at the
Control Box to the MAX MC-100 Motor Controller.
NOTE: Each operator is specifically wired to the Optional
Key Switch when installing dual gate operators if you
choose to connect the key switch. (see illustrations).
Wiring operator
optional key switch to Operator(s)
Optional
Open/Close
Key Switch
Control Box
Key Switch
Primary/Single
Secondary
Key
Switch
Terminal
3 Wires to Key Switch
3 Wires to
Key Switch
Primary/Single Open LEFT
PRIMARY
SECONDARY
OPEN RIGHT
OPEN LEFT
INSIDE Property
OUTSIDE Property
Primary/Single
MAX MC-100
Motor Controller
Secondary
MAX MC-100
Motor Controller
Primary/Single Open RIGHT
OPEN RIGHT
OPEN LEFT
INSIDE Property
PRIMARY
SECONDARY
OUTSIDE Property
Open
(Green)
Gnd
Close
(White)
INPUTS
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
INPUTS
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
Gnd
Key
Switch
Terminal
Primary/Single
MAX MC-100
Motor Controller
Secondary
MAX MC-100
Motor Controller
Open
(Green)
Gnd
Close
(White)
INPUTS
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
INPUTS
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
Gnd
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
Secondary
MAX MC-100
Motor Controller
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
230V
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Select Input Voltage:
115VAC or 230VAC
warranty
VOIDED
if label is
REMOVED
disconnect
power before
servicing unit
WARNING
WARNING
HIGH
HIGH
VOLTAGE
VOLTAGE
!
MAX PS-24 Power Supply
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
ON/OFF
Battery
TEST
Battery
Battery IN
Error
F
MAX BC-7
Battery Module
IMPORTANT
connect to
“BATTERY IN”
before use
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
MAX BC-7
Battery Module
Wiring operator
turn on/off operator power
Turn AC Power Switch ON
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
To turn OFF ALL POWER:
1. Turn OFF AC POWER Switch on MAX PS-24 Power Supply. Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the YELLOW ON/OFF BATTERY button
until MAX BC-7 LEDs turn ON, then release button. LEDs will turn OFF.
Battery power automatically turns ON.
Operator should have Input AC power wired to PS-24, 24V & RS-485 wired between Matrix 1 and MC-100 and “Optional” Key
Switch wired to MC-100. TURN POWER ON. Certain LEDs should normally turn ON accordingly:
AC IN LED:
Normal - Turns ON.
Error - Not ON. Check AC power.
7 Amp Fuse blown. Replace fuse.
Input AC selector switch MUST be set to CORRECT input AC power.
POWER LED:
Normal - Turns ON.
Error - Not ON. Check POWER IN plug on back of MC-100.
Matrix On-Line LED:
Normal - Turns ON.
Error - Not ON. Check RS-485 wiring to Matrix 1.
Limit SW On-Line LED:
Normal - Turns ON.
Error - Not ON. Check LIMIT SWITCH plug.
BATTERY VOLTAGE LEDs:
Normal - 3 LEDs turn ON - Fully charged batteries.
Batteries need charging - LEDs will turn on in sequence until batteries are
fully charged. Batteries are NOT necessary when AC power is available.
BATTERY IN ERROR LED:
Normal - Not ON.
Error - Turns ON. Battery not plugged in to BATTERY IN port.
POWER LED:
Normal - Turns ON.
Error - Not ON. Check 24V wiring from MC-100 Primary/Single.
Motor On-Line PRIMARY LED:
Normal - Turns ON.
Error - Not ON. Check RS-485 wiring to Primary/Single MC-100.
Limit SW On-Line PRIMARY LED:
Normal - Turns ON.
PRIMARY GATE OPEN RIGHT OPEN LEFT LED:
Normal - Turns ON either LED according to switch setting.
Error - Not ON. Check LIMIT SWITCH plug on back of MC-100.
BATTERY IN USE LED:
Normal - Not ON.
Error - Flashes on and off. Battery not plugged in to BATTERY IN port on
BC-7 Battery Module.
MAX PS-24 Power Supply
MAX MC-100 Motor Controller
Matrix 1
MAX BC-7 Battery Module
1
2
3
4
DO NOT CYCLE GATE OPERATOR
AT THIS TIME
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
OFF
OFF
ON
ON
Single Pass Anti-Tailgate
Radio Safety Pause
Mode 0
Gate in Motion Alarms
ON
OFF
ON
OFF
ON
OFF
Mode 1
Mode 1
ON
OFF
Motion Alarm sounds before gate moves and continues until gate stops
Motion Alarms OFF
Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
Beeper Alert OFF
Mode 0
When turned “ON”; After a vehicle clears the Safety Loop, a closing
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
MADE IN USA
WWW.Max.US.com
Battery Back-Up Mode - Page 26
Primary Gate - Page 26
Maglock - Page 29
Gate Tamper - Page 30
In-Ground Loop Connection - Page 29
Anti Tailgate - Page 27
Plug-In Loop Detectors - Page 29
UL Entrapment LEDs - Page 30
Close Timer - Page 26
ID Plug & ID Plug Error LED - Page 30
UL Alarm/Alarm Reset Button - Page 32
Radio Power - Page 28
Partial Open - Page 31
OBD Port Black Box - Page 28
Selectable Gate Speed Control - Page 26
ERD & Motor Overload LEDs - Page 33
Gate Status - Page 32
Radio Relay - Page 28
Emergency Vehicle/Max Open Inputs - Page 30
Normal Opening Devices - Page 25
Close Photocell - Page 32
Operators Communication LEDs - Page 21 & 33
OPEN/STOP/CLOSE Connection - Page 32
Gate Disable - Page 31
Matrix 1 Power - Page 21 & 33
Battery in Use - Page 33
MATRIX 1
MATRIX 1 Back
matrix 1 Overview
matrix 1
1
2
3
Gate in Motion Alarms - Page 28
Single Pass Anti-Tailgate - Page 27
Radio Safety Pause - Page 28
A
B
C
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
1
2
3
4
8
17
16
24
23
25
26
22
20
21
19
A
B
C
18
12
10
10
11
9
5
6
7
13
14
15
matrix 1
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
Power
12 VDC
OR 24 VDC
Radio Power
12 VDC OR 24 VDC
Photocell Power
Card Reader
CLOSE Cycle Photocells ONLY.
See page 14 & 32.
IS NOT UL 325 entrapment protection type B1.
OPEN Cycle
Photocells
ONLY.
Separate power
for Devices.
Keypad
Photo Cell (N.O.)
Photocell (N.O.)
Edge 1
(N.O.)
Edge 2
(N.O.)
24V
RS-485
RS-485
250 mA Max.
Stop
GND
GND
GND
Key Switch
Telephone Entry
3-Button
Station
See page 32.
Additional
Reset Button
See page 32.
Gate Disable
Switch or Timer
See page 31.
Primary/Single Operator
Connect to MC-100 motor controller.
See pages 21 & 33.
Optional Key Switch
See page 22.
Optional
Control Box
Key Switch
See page 22.
MC-100 Motor Controller See page 17
Secondary Operator
Connect to MC-100
See pages 21 & 33.
Radio Receivers
See page 28.
In-Ground Loops
See page 29.
Loop Detectors
See page 29.
Safety Loops Wired in series
Emergency OPEN
(Overrides gate
disable switch)
MAX OPEN
(Overrides gate
disable switch)
Center
Loop
Safety
Loop
Safety
Loop
Exit
Loop
Gate Tamper:
See page 30.
24V Power for Matrix 1 from
Primary/Single operator ONLY. See pages 17 & 33.
ID Plug:
See page 30
ID Plug Error LED. See page 30
4-Wire
Radio
3-Wire
Radio
ON
OFF
ON
1
2
3
4
5
6
7
8
5 = Optimum Sens.
= Increase Sens.
= Decrease Sens.
DEFLECTOMETER
POWER
ON = Normal Power
OFF= No Power
LED INDICATORS
DETECT
ON = Detect
OFF= No Detect
2 Hz Flash=Delay Timing
SW1 SW2 Frequency
ON
ON = Low
ON
OFF = Medium-Low
OFF ON = Medium-High
OFF OFF = High
SW4 SW5 Output B
ON
ON = Pulse on Entry
ON
OFF = B same as A
OFF ON = Pulse on Exit
OFF OFF = Loop Fault
SW3
ON = Fail Secure
OFF = Fail Safe
SW6
ON = 2 Second Delay
OFF = No Delay
SW7
ON = Normal Presence
OFF = Infinite Presence
SW8
ON = Sensitivity Boost
OFF = No Sensitivity Boost
Loop Fault
1 Flash = Open Loop
2 Flashes= Shorted Loop
3 Flashes=25% change
of Inductance
Both LED’s Flashing=
Current Loop Fault
PWR LED Flashing=
Previous Loop Fault
EDI
Tel: 480.968.6407
DEFLECTOMETER
SENS
RESET
POWER
DETECT
EDI
SENS
LMA1800
OPTIONS
1
2
3
4
5
6
7
8
ON
UL LED Indicators ONLY.
See page 30.
Control Box
Alarm Reset Button
Strobe Light
See page 32
Emergency/Security Devices
Security Device
Security Device
Normal Opening Devices
Normal
Opening
Device
Normal
Opening
Device
GATE OPEN
GATE CLOSED
UL 325
Entrapment
Protection
Type B1
See
page 14.
Maglock Connection:
Must be specifically
wired,
See page 29.
Reverse Edges: See page 14.
Connect to Edge 1 and/or Edge 2.
UL 325 entrapment protection type B2.
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
matrix 1
PRESS
to RESET
Motion
Sensor
Security
Camera
Gate Status:
See page 32.
Dry Contact
(N.O.)
Dry Contact (N.O.)
(N.O.)
(N.O.)
wiring Overview
See page 30.
Control
Box
matrix 1
The Gate Speed knob has 16 selectable settings to choose from. The
speed varies from approximately 11.5 sec to 20 sec depending on the
weight and length of the specific gate. Make sure gate speed is appro-
priate for the size and length of the gate.
NOTE: The Auto Gate Sync feature provides synchronous opening and
closing between bi-parting gates.
OPEN RIGHT
OPEN LEFT
matrix 1
primary gate - open left / open right
selectable gate speed control
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
12VDC
GND
24VDC
GND
MAX
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
CENTER
EXIT
CLOSE
ID
PLUG
N/CLOSE CONTR
CENTER
SAFETY
PRIMARY
GAT
A
RY
ACK-UP MODE
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1
OPEN
RIGHT
OPEN
LEFT
PRIMARY
GATE
Set the Primary/single gate operator with Primary Gate setting. Secondary operator will
automatically be set to the opposite opening direction as the primary gate operator when
using dual gates.
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
CLOSE TIMER
MAX
MIN
OFF
MOTOR
ON
SWITCH
ON-LINE
TOCELL
TRIKE
ND
YPAD / RDR
D
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
MAX
GATE SPEED
STOP
CLOSE
MOTOR MOTION
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
The Close Timer has 16 selectable settings for automatic gate close time.
Knob at OFF position: close timer OFF.
1st click clockwise - Knob at MIN position: 1/2 sec...
2nd click clockwise: 1 sec...
3rd click: 4 sec...
4th click: 8 sec...
5th click: 12 sec (4 sec increments for each successive click up to 60 sec MAX)
NOTE: 1/2 sec MIN position is recommended for High Traffic areas.
gate close timer
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
ID
PLUG
P
CLOSE TIMER
MAX
MIN
OFF
LEAVE OPEN - The gate operator will continue to cycle the gate normally until the
battery power can no longer cycle the gate. When this happens, the gate operator
will open the gate and leave it in the OPEN position until power is restored.
LEAVE CLOSED - The gate operator will continue to cycle the gate normally until
the battery power can no longer cycle the gate. When this happens, the gate will
close if not already in the CLOSE position, where it will remain until power is
restored. Enough battery power is retained for a LIMITED time to operate
emergency vehicle entry (Using opening devices connected to FIRE DEPT and/or
MAX OPEN inputs to FULLY open gate).
OPEN 1 TIME - The gate operator will automatically OPEN gate once and leave it
in the OPEN position until power is restored.
The Battery Back-Up Mode setting will determine how the gate operator will function during
an AC power failure. Gate operator with a full battery charge should cycle a 2000 lbs gate
(battery power ONLY) approximately 450 times.
battery back-up mode
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
EXIT
ANTI
TAILGATE
CLOSE TIME
ID
PLUG
MATIC OPEN/C
OFF
ON
MAX
12VDC
GND
24VDC
GND
MIN
OFF
SAFETY
DE
OPEN
1 TIME
AUT
RIX 1
BATTERY
BACK-UP MODE
LEAVE
OPEN
LEAVE
CLOSED
OPEN
1 TIME
FIRE DEPT/MAX OPEN Inputs
INSIDE Property
PRIMARY
LED turns ON for
MAX setting ONLY
LED turns ON for
MAX setting ONLY
SECONDARY
OUTSIDE Property
Turned OFF - Close timer will close the gate. If an in-ground safety or exit loop
gets activated during the close cycle, gate will REVERSE to the open position.
Turned ON - (In-ground loops required) Gate will close after all the in-ground
loops have been cleared no matter how long the close timer is set for. If an
in-ground safety loop gets activated during the close cycle, gate will REVERSE
to the open position.
Turned ON - (In-ground loops required) Gate will close after all the in-ground
loops have been cleared no matter how long the close timer is set for. When an
in-ground safety loop gets activated during the close cycle, gate will PAUSE and
NOT reopen. When loop is cleared, gate will continue to close preventing
UNAUTHORIZED entry.
anti tailgate
Single pass anti-tailgate
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
SAFETY
ANTI
TAILGATE
OFF
ON
AUTHORIZED Vehicle
UNAUTHORIZED Vehicle
1
2
When last Safety Loop is cleared, gate will close.
NOTE: If a VALID open command is received at this
point, gate will stop and reopen.
Safety Loop gets activated and PAUSES the closing gate.
Gate will NOT reopen. Vehicle MUST back up for loop to
clear, then gate continues to close. NO unauthorized entry.
NO VALID open command.
OFF
OFF
ON
ON
Single Pass Anti-Tailgate
Radio Safety Pause
Mode 0
Gate in Motion Alarms
ON
OFF
ON
OFF
ON
OFF
Mode 1
Mode 1
ON
OFF
Motion Alarm sounds before gate moves and continues until gate stops
Motion Alarms OFF
Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
Beeper Alert OFF
Mode 0
When turned “ON”; After a vehicle clears the Safety Loop, a closing
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
MADE IN USA
WWW.Max.US.com
OFF
ON
VALID open command was given.
UNAUTHORIZED Vehicle Approaches
NO VALID open command is given.
Vehicle is attempting to activate safety loop
before the gate’s close cycle is complete,
expecting gate to reopen.
SAFETY LOOP
CENTER LOOP
SAFETY LOOP
INSIDE
Property
OUTSIDE
Property
CENTER LOOP
SAFETY LOOP
SAFETY LOOP
MATRIX 1 Back
- Gate Pauses -
- Gate Pauses -
LED stays ON
when Anti Tailgate
is ON
Turned ON - The radio transmitter (remote control) can PAUSE a MOVING
gate by pressing the remote button. Pressing the remote button again will
cause the gate to CONTINUE in the SAME direction. This process can be
repeated as many times as desired.
Radio safety pause
OFF
OFF
ON
ON
Single Pass Anti-Tailgate
Radio Safety Pause
Mode 0
Gate in Motion Alarms
ON
OFF
ON
OFF
ON
OFF
Mode 1
Mode 1
ON
OFF
Motion Alarm sounds before gate moves and continues until gate stops
Motion Alarms OFF
Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
Beeper Alert OFF
Mode 0
When turned “ON”; After a vehicle clears the Safety Loop, a closing
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
MADE IN USA
WWW.Max.US.com
Mo
Motion Alarms
O
OFF
ON
OFF
Mode 1
Motion Alarm sounds before gate m
larms OFF
attery Back-Up Mode while gate
clos
Radio Safety Pause
g gate
ill
if
di
OFF
Mode 1
Beeper
MATRIX 1 Back
OFF ON
MODE 0 - Turned ON - Alarm will sound BEFORE and DURING gate cycle
to alert surrounding area.
NOTE: A strobe light can be connected to UL ALARM connection that will
flash ON and OFF when the alarm is sounding. See page 32.
MODE 1 - Turned ON - Alarm will beep when using ONLY battery power
DURING gate cycling. This brings to attention that only battery power is
being used and NOT normal AC power.
gate in motion alarms
OFF
OFF
ON
ON
Single Pass Anti-Tailgate
Radio Safety Pause
Mode 0
Gate in Motion Alarms
ON
OFF
ON
OFF
ON
OFF
Mode 1
Mode 1
ON
OFF
Motion Alarm sounds before gate moves and continues until gate stops
Motion Alarms OFF
Beeper Alert sounds in Battery Back-Up Mode while gate is in motion
Beeper Alert OFF
Mode 0
When turned “ON”; After a vehicle clears the Safety Loop, a closing
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.
When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.
MADE IN USA
WWW.Max.US.com
MATRIX 1 Back
Mode 0
ON
OFF
ON
OFF
Mode 1
Connect a 3-wire or 4-wire radio receiver to Matrix 1.
Choose 12V or 24V, 250 ma max. power.
CLOSE TIMER ON - Each time the remote button
is pressed during the Close Timer countdown
(gate is open) causes the timer to reset and
begin again. When close timer countdown is
complete, gate will close.
CLOSE TIMER OFF - Sequence when
pressing remote button:
Press One Time - gate OPENS . . .
Press Again - gate STOPS . . .
Press Again - gate CLOSES . . .
Press Again - gate STOPS . . .
Sequence repeats when button is
pressed again.
radio receiver
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
ID
PLUG
24VD
GND
12VDC
GND
24VDC
GND
4-Wire
Radio
3-Wire
Radio
Receiver Input
Removable
Terminal
On Board Diagnostics (OBD) port will download a simple .txt file to trouble-
shoot gate operator errors and to view normal transaction logs.
Plug a USB flash drive into port. LED will flash while file is downloading.
When LED stops flashing, remove flash drive and plug it into any computer
with an available USB port and simple text reader software (typical).
The operator’s event history is stored as a simple .txt file. Contained in
the file is a log of the most recent 1000 events. Quickly identify and
diagnose a complex or intermittent problem. The file can even be
e-mailed to the factory for on site diagnosis if necessary. The files will
be stored as an ongoing event history of the transactions that occur at
the gate operator.
obd port black box
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
CLOSE
POSITION
RECORDER
ID
PLUG
P
O
CE
SAFETY
12VDC
GND
24VDC
GND
USB Flash Drive
OBD PORT
BLACK BOX
Choose 12 VDC
OR 24 VDC
(250 mA Max.)
MIN
MIN
MAX
MAX
OFF
UL
ENTRAP
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
12VDC
GND
24VDC
GND
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
Radio
Position
NOTE: Use a drain hole in bottom of control
box to expose wire antenna of receiver.
NOTE: See page 44 for
more information about
this unique feature.
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
PRIMARY
BATTERY
1
CLOSE TIMER
MAX
MIN
PHOT
OFF
SAFETY
matrix 1
Matrix 1 will accept third party loop detectors in the 3 ports. Each loop detector has a
corresponding in-ground loop that must be connected for the loop system to operate
(see below). Power down Matrix 1 BEFORE connecting loop detectors. Refer to your
chosen loop detector’s instruction sheet for specific information about loop detector.
Loop Detectors
maglock
Maglock MUST be connected as shown.
MAGLOCK DELAY: You MUST select a time
delay when using a maglock.
Maglock power disengages 1.5 sec or
2 sec before gate starts opening.
MAGLOCK LED (Monitors Maglock):
ON - Locked OFF - Unlocked
Flashing - Problem with Maglock
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
OPEN
MAX
GATE SPE
STOP
MOTOR MOTION
MIN
M
EPT
RADIO SIG.
DIO GND
CENTER
EXIT
ANTI
TAILGATE
UTOMATIC OPEN/CLOSE CONTROLS
OFF
ON
EXIT
CENTER
Reno
Loop Detector
(Plug-In)
Diablo
Loop Detector
(Plug-In)
Connect desired loop detector
to appropriate loop port
Maglock
Power
Pos
Neg
Pos
Neg
Maglock
SAFETY
CENTER
EXIT
OPEN/CLOSE CONTROLS
ON
1
2
3
4
5
6
7
8
5 = Optimum Sens.
= Increase Sens.
= Decrease Sens.
DEFLECTOMETER
POWER
ON = Normal Power
OFF= No Power
LED INDICATORS
DETECT
ON = Detect
OFF= No Detect
2 Hz Flash=Delay Timing
SW1 SW2 Frequency
ON
ON = Low
ON
OFF = Medium-Low
OFF ON = Medium-High
OFF OFF = High
SW4 SW5 Output B
ON
ON = Pulse on Entry
ON
OFF = B same as A
OFF ON = Pulse on Exit
OFF OFF = Loop Fault
SW3
ON = Fail Secure
OFF = Fail Safe
SW6
ON = 2 Second Delay
OFF = No Delay
SW7
ON = Normal Presence
OFF = Infinite Presence
SW8
ON = Sensitivity Boost
OFF = No Sensitivity Boost
Loop Fault
1 Flash = Open Loop
2 Flashes= Shorted Loop
3 Flashes=25% change
of Inductance
Both LED’s Flashing=
Current Loop Fault
PWR LED Flashing=
Previous Loop Fault
EDI
Tel: 480.968.6407
DEFLECTOMETER
SENS
RESET
POWER
DETECT
EDI
SENS
LMA1800
OPTIONS
1
2
3
4
5
6
7
8
ON
In-ground loop connection
Connect each in-ground loop wires to the appropriate input. Lead wires
should be twisted together 6 twists per foot minimum.
See page 15 for in-ground loop installation.
Safety loop wires must be wired in series.
Each LED will light when the corresponding
loop detector get activated by a vehicle
passing over its in-ground loop.
LEDs will flash when there is an error with
the corresponding loop detector.
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
T
Removable Terminal
Lead
Wires
SAFETY LOOP
SAFETY LOOP
EXIT LOOP
CENTER LOOP
Outside Property
Inside Property
EXIT
CENTER
SAFETY
Diablo
Controls, Inc.
Stuck in traffic for over 37 years!
DSP-40 VEHICLE DETECTOR
7 to 30 Volts AC or DC 20 ma max.
Indicators
Steady indicates power
Fast blink - Shorted loop
Slow blink - Open loop
Detect Indicator
Green -
Red -
RESET
POWER
DETECT
DSP - 40
Diablo
Controls, Inc.
1
2
3
4
5
6
7
8
ON
EXT=
SW 8
SW 7
OFF
OFF
ON
OFF
ON
ON
OFF
ON
0 SEC 2 SEC 5 SEC 10 SEC
DLY=
SW 6
SW 5
OFF
OFF
ON
OFF
ON
ON
OFF
ON
0 SEC 2 SEC 5 SEC 10 SEC
FREQ=
SW 2
SW 1
ON
ON
OFF
ON
OFF
OFF
ON
OFF
LOW
NORM MED
HIGH
BOOST
SW 4
OFF
ON
ON
OFF
MODE
SW 3
OFF
ON
FAIL SECURE
FAIL SAFE
VEHICLE DETECTOR
MODEL H2
8-30 VDC
LOW
NORM
HIGH
0
3
7
SENSITIVITY
RENO
RENO
A&E
POWER
DETECT
FAIL
EDI
Loop Detector
(Plug-In)
EDI
Loop Detector
Low Current Draw
(Plug-In)
ON
1
2
3
4
5
6
7
8
5 = Optimum Sens.
= Increase Sens.
= Decrease Sens.
DEFLECTOMETER
POWER
ON = Normal Power
OFF= No Power
LED INDICATORS
DETECT
ON = Detect
OFF= No Detect
2 Hz Flash=Delay Timing
SW1 SW2 Frequency
ON
ON = Low
ON
OFF = Medium-Low
OFF ON = Medium-High
OFF OFF = High
SW4 SW5 Output B
ON
ON = Pulse on Entry
ON
OFF = B same as A
OFF ON = Pulse on Exit
OFF OFF = Loop Fault
SW3
ON = Fail Secure
OFF = Fail Safe
SW6
ON = 2 Second Delay
OFF = No Delay
SW7
ON = Normal Presence
OFF = Infinite Presence
SW8
ON = Sensitivity Boost
OFF = No Sensitivity Boost
Loop Fault
1 Flash = Open Loop
2 Flashes= Shorted Loop
3 Flashes=25% change
of Inductance
Both LED’s Flashing=
Current Loop Fault
PWR LED Flashing=
Previous Loop Fault
EDI
Tel: 480.968.6407
DEFLECTOMETER
SENS
RESET
POWER
DETECT
EDI
SENS
LMA1800
OPTIONS
1
2
3
4
5
6
7
8
ON
OPTIONS
ON
1
2
3
4
5
6
7
8
5 = Optimum Sens.
= Increase Sens.
= Decrease Sens.
DEFLECTOMETER
POWER
ON = Normal Power
OFF= No Power
LED INDICATORS
DETECT
ON = Detect
OFF= No Detect
2 Hz Flash=Delay Timing
SW1 SW2 Frequency
ON
ON = Low
ON
OFF = Medium-Low
OFF ON = Medium-High
OFF OFF = High
SW4 SW5 Output B
ON
ON = Pulse on Entry
ON
OFF = B same as A
OFF ON = Pulse on Exit
OFF OFF = Loop Fault
SW3
ON = Fail Secure
OFF = Fail Safe
SW6
ON = 2 Second Delay
OFF = No Delay
SW7
ON = Normal Presence
OFF = Infinite Presence
SW8
ON = Sensitivity Boost
OFF = No Sensitivity Boost
Loop Fault
1 Flash = Open Loop
2 Flashes= Shorted Loop
3 Flashes=25% change
of Inductance
Both LED’s Flashing=
Current Loop Fault
PWR LED Flashing=
Previous Loop Fault
EDI
Tel: 480.968.6407
DEFLECTOMETER
SENS
RESET
POWER
DETECT
EDI
SENS
LMA1800-LP
1
2
3
4
5
6
7
8
ON
Third party external loop detectors can be used if
desired with the MAX External Loop Detector Cable
Adapter. (1) One is included with the operator but
more can be purchased if needed.
External
Loop
Detector
External Loop Detectors
Plug-In Loop Detectors
Wire to
back of
detector
Plug-In Loop Detector
Safety loops need
to be wired in series.
Power 15 VDC (Red)
Loop Detect
Output (White)
Com, Gnd (Black)
Power Terminal
MAX External Loop
Detector Cable Adapter
MAG
LOCK
MAGLOCK
DELAY
OFF
2Sec
1.5Sec
COM
NC
Tamper NO
COM
GND
Tamper IN
+
+
-
-
Power
Terminal
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
PARTIAL
OPEN
OBD PORT
BLACK BOX
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
EX
ANTI
TAILGATE
AU
EDGE 2
ENTRAP
ER
12
matrix 1
id plug
AN ID Plug comes standard on Matrix 1. It identifies the type
of gate operator and MUST be plugged in or the Matrix 1 WILL
NOT function.
ID PLUG ERROR LED: Will light when ID PLUG is missing.
Low Profile Swing
ID Plug
Knox
Box
Key
Switch
ID
PLUG
ID PLUG
ERROR
LOW PROFILE
SWING
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
12VDC
GND
24VDC
GND
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
SAFETY
CENTER
EXIT
ANTI
TAILGATE
AUTOMATIC OPEN/
Tam
MAX
GATE SP
STOP
CLOSE
REVERSE SEN
ND
24VDC
GND
ED
MOTOR OVERLOAD
NO LIMIT SWIT
CLAM
T
O SIG.
GND
ID PLUG
PARTIAL
OPEN
MOTOR MOTION
UL entrapment LEDs
UL ENTRAPMENT LEDs will indicate when a OPENING DIRECTION
Photocell and/or Sensing Edge(s) have been activated. If alarm gets
triggered, press reset button on control box to turn alarm off.
NOTE: UL safety approved devices are wired to the MC-100 motor
controllers ONLY. DO NOT wire them to the Matrix 1.
REVERSE SENSITIVITY LED: Will light when the gate encounters an
obstruction triggering the ERD sensor.
PHOTOCELL
EDGE 1
EDGE 2
UL
ENTRAP
REVERSE SENSITIVITY
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
ID
PLUG
12VDC
GND
DC
emergency vehicle/max open inputs
FIRE DEPT lnput: Should be connected to a knox box device to allow
the proper authorities to gain emergency access when necessary. The
input will override the GATE DISABLE input and allow EMERGENCY
personnel FULL 24/7 access. Gate fully opens.
MAX OPEN Input: Can be connected to a key switch and used as an
ADDITIONAL input from the FIRE DEPT input. The input will override
the GATE DISABLE input and allow SECURITY personnel FULL 24/7
access. Gate fully opens.
FIRE DEPT
GND
MAX OPEN
GND
Security
Camera
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
ID
PLUG
PARTIAL
OPEN
CLOSE TIMER
MAX
PHOTOC
MIN
OFF
SAFETY
CENTER
EXIT
TAILGATE
OFF
ON
EXIT
GA
Tamp
Gate Tamper
GATE
TAMPER
Tamper NO
COM
GND
Tamper IN
The GATE TAMPER can be used for various
functions such as turning a warning light, siren or
camera on when the gate is tampered with
(Vandalized Gate). The gate operator defines a
“Vandalized Gate” as UNAUTHORIZED movement
of the gate. This can occur if the red release
handle clamp is lifted and gate is manually moved
from the closed position or the gate is forced
open from the closed position without authorization.
TAMPER NO/Com Relay: Connect a warning light, siren, camera
or an existing alarm system to relay.
TAMPER IN/GND Input: Connect a sensor device to input. When
Tamper In/GND gets triggered, device that is wired to Tamper
relay (NO/Com) will activate.
Siren
Warning
Light
Motion
Sensor
Power
Power
Existing
Building
Alarm
System
NOTE: See page 43 for
more information about
this unique feature.
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
PEN
STOP
ER
EXIT
CENTER
REVERSE SENSITIV
OTOR OVERLOAD
WITCH /
PING
MAX
IN
OFF
ST
12VDC
GND
ELL
DR
gate disable
GND
GATE DISABLE
ON
OFF
IMPORTANT: Limit switches MUST be learned BEFORE Partial Open can be recorded.
To RECORD PARTIAL OPEN:
1. With gate in CLOSED position, press and release PARTIAL OPEN
button to START recording. Blue LED starts flashing.
2. Press 3-button station OPEN button to start gate’s open cycle.
3. Press 3-button station STOP button when gate is in desired partial open position (Beyond center loop).
4. Press PARTIAL OPEN button AGAIN to STOP recording. Blue LED stops flashing,
open position has been recorded. LED remains ON.
To ERASE PARTIAL OPEN recording:
Press and HOLD PARTIAL OPEN button for 5 sec. LED turns OFF.
partial open
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MAX
12VDC
GND
24VDC
GND
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
OPEN
CLAMP SLIP
24VDC
GND
SIG.
ND
OPEN
STOP
CLOSE
POSITION
RECORDER
PARTIAL
OPEN
MOTOR MOTION
CAUTION: Gates partial OPEN
position MUST be outside the
Center Loop when in-ground
loops have been installed.
CENTER LOOP
NOTE: The FIRE DEPT and/or MAX
OPEN connected devices will always
FULLY open gates even when the
partial open is being used.
An ON/OFF switch or 7-Day timer devices can be connected to the GATE DISABLE
input. When these devices are turned ON, they will DISABLE normal opening
devices such as keypad, exit loop etc. The FIRE DEPT/ MAX OPEN and RADIO
inputs will remain enabled when GATE DISABLE has been turned ON. This is
useful when the gated area needs to be secured from ALL but emergency or
authorized vehicle entry. Some examples are: Residential home vacation period or
during closed hours of a business when no one can monitor the property.
When GATE DISABLE is turned ON: The operator will beep for 3 minutes
BEFORE arming itself. This allows time to turn ON GATE DISABLE and
leave the property before it is armed.
When FIRE DEPT/MAX OPEN gets activated: Gate opens and GATE TAMPER
relay will activate immediately.
When RADIO Input gets activated: Gate opens and GATE TAMPER relay will activate after 3 min. This allows time to turn OFF
GATE DISABLE or disarm an existing building alarm system if connected.
IMPORTANT: It is NOT recommended activating the GATE DISABLE device while persons are present inside the property.
Enabled inputs when
GATE DISABLE is turned ON.
A gate can set to partially open by recording the PARTIAL OPEN gate cycle. LED will stay lit
when PARTIAL OPEN is ON.
NOTE: See page 44 for
more information about
this unique feature.
in Remote Location
Factory Wired
Reset Button
Strobe
Light
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
OBD PORT
BLACK BOX
MOTOR MOTION
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
ID PLUG
ERROR
ENTRAP
G
OPEN
STOP
CLOSE
TIVITY
UL alarm / Alarm Reset button
A UL ALARM (strobe light) can be connected. It will turn ON
when the GATE IN MOTION - Mode 0 and/or Mode 1 are
turned ON (see page 28).
Press RESET BUTTON to turn OFF
activated strobe light.
Press RESET BUTTON to turn OFF
an activated alarm.
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
CENTER
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
UL
ALAR
RESET
GND
CLOSE TIMER
PARTIAL
OPEN
CENTER
MAX
MIN
OFF
SAFETY
MAX
POSITION
RECORDER
ID
PLUG
CL
OBD PORT
BLACK BOX
MIN
12VDC
STATUS
gate status monitoring
GATE STATUS LEDs will turn ON when gate is in the OPEN or
CLOSED position.
Connect a gate monitoring device to GATE STATUS relays to
show if gate is in the OPEN or CLOSED position.
OPEN/COM Relay: Activates momentarily (1 sec) when gate gets
to the OPEN position.
CLOSE/COM Relay: Activates when gate gets to the CLOSED
position.
open / stop / close Connection
The OPEN/STOP/CLOSE inputs will allow a standard 4-wire
3-Button Station or an additional External RESET Button to be
connected.
Corresponding LEDs will light when each button is activated.
OPEN
COM
CLOSE
GATE
STATUS
GATE OPEN
GATE CLOSED
OPEN
STOP
STOP
CLOSE
Com
Power
GND
GND
N.O.
Com
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
OPEN
MAX
GATE SPEED
REVERSE
MOTOR OVERL
NO LIMIT SWITCH /
CLAMP SLIPPING
CLOSE TIME
ON
PARTIAL
OPEN
SAFETY
PHOT
GN
STRIKE
GND
KEYPAD
GND
E DEPT
ND
MAX OPEN
GND
SIG.
O GND
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
3-Button
Station
Additional External
Reset Button
PRESS
to RESET
closing photocell connection
The PHOTOCELL input will allow a CLOSING DIRECTION PHOTOCELL to
be connected. 12V or 24V power can be supplied for the photocells.
NOTE: This input is NOT UL SAFETY PHOTOCELL. ALL UL inputs MUST
be made at the MAX MC-100 motor controller on the gate operator.
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
PHOTOCELL
GND
12V or 24V
Photocells
ID
PLUG
24VD
GND
12VDC
GND
24VDC
GND
Choose 12 VDC OR 24 VDC
(250 mA Max.)
INSIDE Property
CLOSING
GATE
DIRECTION
OUTSIDE Property
Additional CLOSING Cycle
Photocells can be connected.
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
Secondary
Secondary
MC-100
MC-100
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
Primary/Single
Primary/Single
MC-100
MC-100
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
Primary/Single
Primary/Single
MC-100
MC-100
matrix 1
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
KEYPAD / RDR
GND
FIRE DEPT
MAX OPEN
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
FIRE D
MAX
RADIO SI
RADIO
O
MAX
GATE SPEED
NO LIM
CLAMP S
MIN
MAX
CLOSE TIME
POSITION
RECORDER
ID
PLUG
PARTIAL
OPEN
OBD PORT
ACK BOX
MIN
O
SAFETY
gate operators communication leds
24V power for matrix 1
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
MOTOR MOTION
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
GND
24VDC
GND
MAX
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
POWER
GATE
STATUS
(+)
GND
(-)
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
PLUG
MIN
MAX
OPEN
STOP
CLOSE
MOTO
REVERSE SENSITIVITY
MOTOR OVERLOAD
T SWITCH /
LIPPING
GATE
STATUS
24V
GND
battery in use led
BATTERY IN USE LED will light when operator is using ONLY battery
back-up power. The GATE IN MOTION Alarm can be set up to sound alarm
when operator is using ONLY battery power DURING gate cycling. This
brings to attention that only battery power is being used and NOT normal
AC power. See page 28.
LED Flashing NOTE: BATTERY IN USE and POWER LEDs flash together
when the battery is not plugged into the BATTERY IN port of the MAX BC-7
Battery Module. Make sure battery plug is correctly installed and there is no
damaged or loose wires.
PRIMARY/SINGLE operator to the PRIMARY GATE (+, GND, -).
SECONDARY operator to the SEC GATE (+, GND, -). See page 21.
LIMIT SWITCH ON-LINE LEDs: will light for
each gate operator’s limit switch that the
Matrix 1 is successfully communicating with.
MOTOR ON-LINE LEDs: will light for each gate
operator’s MC-100 Motor Controller that the
Matrix 1 is successfully communicating with.
Connect 24VDC POWER from PRIMARY/SINGLE operator
ONLY. See page 21.
POWER LED: Will light when 24V low voltage power is
connected.
NOTE: DO NOT power any external devices using this
connection. This power is reserved for Matrix 1 ONLY.
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
OPEN
STOP
CLOSE
CLOSE TIMER
C
CLOSE
PARTIAL
OPEN
C
REVERSE SENSITIVITY
TOR OVERLOAD
/
MAX
MIN
OFF
SAFETY
GATE
STATUS
OTOR
LIM
SWITCH
ON-LINE
24VDC
GND
DISAB
POWER
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
BATTERY
IN USE
POWER
motor motion leds
REVERSE SENSITIVITY LED: Will light when the gate encounters an obstruction triggering
the ERD sensor.
MOTOR OVERLOAD LED: Will light when excessive current is being drawn
by motor caused by damaged gate hardware or gate is too heavy.
NO LIMIT SWITCH/CLAMP SLIPPING LED: Will light when either limit switch
does NOT activate from it’s learned positions.
NO LIMIT SWITCH/CLAMP SLIPPING LED: Will light when the release handle clamp is
slipping on the output shaft. The learned gate OPEN and CLOSE positions will NOT be correct
when the limit tabs keep changing position.
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
N
STOP
CLOSE
CLOSE TIMER
PARTIAL
OPEN
MOT
CEN
MAX
MIN
OFF
SAFETY
CLAMP
OBD PORT
BLACK BOX
MIN
12VDC
GND
MAX
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
24V
Made in USA
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
PWR IN
Error
F
MAX BC-7
Battery Module
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
The limit tabs need to be set BEFORE the gate can be cycled or DAMAGE could occur.
Approximate OPEN and CLOSED
limit tab positions.
OPEN LED
OPEN LED
CLOSED Tab
Activated
Position
CLOSED Tab
Activated
Position
OPEN Tab
Activated
Position
OPEN Tab
Activated
Position
Push and HOLD the JOG LEFT or JOG RIGHT
buttons accordingly on the MAX MC-100 motor
controller to move the gate (release the button to
stop gate). This allows gate to be moved back and
fourth without leaving the operator to “fine tune”
the open and close gate positions if desired.
Adjustments
open and close limits
CLOSED
LIMIT
OPEN
LIMIT
Limit
Switch Box
OPEN Limit
switch contact
point.
CLOSED Limit
switch contact
point.
IMPORTANT: Manually Release arm and move the
gate to the desired OPEN and CLOSED positions to
adjust the limit tabs. Make sure power is ON.
A
r
m
O
p
e
n
i
n
g
D
ir
e
c
ti
o
n
A
r
m
O
p
e
n
i
n
g
D
ir
e
c
ti
o
n
Arm Closed Position
Arm Closed Position
Arm Open Position
Arm Open Position
Open Limit Switch
Closed Limit Switch
CLOSED LED
CLOSED LED
Open LEFT
R
o
ta
te
L
i
m
it
T
a
b
u
n
ti
l
L
E
D
l
ig
h
ts
CLOSED
LIMIT
OPEN
LIMIT
Arm in CLOSED
position
Operator
Opens RIGHT
ADJUST LIMITS:
CLOSED
LOSE
LOSE
LIMIT
LIMIT
LIMIT
LIMIT
LIMIT
LIMIT
LIMIT
LED
lights
Limit
Tab Screw
1. Move gate to OPEN position.
2. Loosen open limit tab screw.
3. Rotate open limit tab until open
LED lights.
4. Tighten open limit tab screw.
5. Move gate to CLOSED position.
6. Loosen closed limit tab screw.
7. Rotate closed limit tab until closed
LED lights.
8. Tighten closed limit tab screw.
Cycle the gate OPEN and CLOSED after the limit
tabs have been set AND the arm is SECURE.
Operator will cycle slowly to LEARN the open and
closed gate positions. After the operator learns
the gate positions, it will cycle at the GATE SPEED
selected for normal operation.
Manually Release Arm
“Fine Tune” Limits Adjustment
IMPORTANT: Manually Secure Arm (see page 35)
IMPORTANT: LEDs MUST light up when gate
reaches OPEN and CLOSE positions or operator
WILL NOT learn gate positions. If gate positions
are not learned, gate cycling speed will remain
slow during normal operation.
EXAMPLE:
LED Indicators
IMPORTANT:
Remove breather
pin from gear
reducer BEFORE
cycling operator.
WARNING: Avoid the moving arm while “Fine Tune” adjusting.
Breather Pin
CAUTION
REMOVE
BEFORE
OPERATION
release handle clamp
Tighten the Adjustment bolt until desired result is achieved.
The release handle clamp has been factory adjusted and
SHOULD NOT need any adjustment.
IMPORTANT: The red handle MUST BE FIRMLY secure in the
HORIZONTAL position.
NOTE: When limit tabs are already set and the release handle is put
back in the secure position but the gate is NOT in the full open or close
position, the operator will automatically re-align the gate’s open and
close tabs. No readjustment is necessary.
After Release Handle Clamp is in the SECURE HORIZONTAL
position:
Pull the arm. NO slippage should occur.
If it does, readjust.
Adjustment
Bolt
factory set bolt
DO NOT adjust
adjust bolt
for firm grip
Arm
Adjustment:
Re-Attach to Operator:
Limit Pin
Limit Tabs
Slot
Release Handle Clamp
Limit pin MUST fit into slot in bottom of
release handle clamp directly under the
arm when reattaching arm to operator.
IMPORTANT: The arm MUST NOT slip
when the gate is cycling or the gate OPEN
and CLOSE limit positions will NOT be
LEARNED. Gate speed will remain slow if
gate positions are NOT learned.
Release Handle Clamp MUST be
HORIZONTAL when FIRMLY secured.
NO
Made in USA
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
Battery IN
Error
F
MAX BC-7
Battery Module
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Position gate half-way open and STOP gate.
This gate position will put the most amount of
resistance on the ERD sensor when gate cycles.
Allow the gate to strike an immobile object while OPENING and CLOSING. The gate MUST reverse
direction after striking the object. If it does not, increase the ERD Sensitivity. Repeat this process
until the correct sensitivity is set. If alarm sounds while preforming this procedure, press alarm
reset button on control box.
NOTE: When solid gates are installed in unusually high wind areas, ERD sensor can be set to Min (position 16) to keep the
gate cycling normally in such extreme conditions.
CAUTION: Minimum sensitivity setting (position 16) results in gate exerting MAXIMUM force before reversing direction.
Test ERD Sensitivity
The Phantom 2000 is equipped with an ERD Sensor - Electronic Reversing Device (Type A) that functions as the primary
entrapment protection according to UL 325 standards. The gate will reverse direction after encountering an obstruction in
either the OPEN or CLOSE gate cycle.
When the gate encounters an obstruction during the CLOSE cycle, it will reverse to the open position and PAUSE the gate. An
input command (press remote button or exit loop) is needed BEFORE the gate will reset and close again.
When the gate encounters an obstruction during the OPEN cycle, it will reverse approximately 6 inches and PAUSE the gate. An
input command (press remote button or exit loop) is needed BEFORE the gate will reset and open again.
For the ERD Sensitivity to function correctly:
• THE RELEASE HANDLE CLAMP MUST NOT SLIP when the gate encounters an obstruction.
• Limit switches must be learned BEFORE adjusting the ERD Sensitivity.
Adjustments
reverse sensor (erd)
MC-100 motor controller
Alarm Reset
Button
STOP Gate
STOP Gate
Half-way
Half-way
CLOSE gate. If ERD sensor triggers, reduce
sensitivity. If sensor does NOT trigger,
sensitivity is set correctly.
CLOSE Gate
CLOSE Gate
1
2
1. Turn knob clockwise
until blue LED lights up
(Max sensitivity reached,
position 1) . . .
2. Turn knob counter-clock-
wise to reduce sensitivity
during testing as needed
(LED will turn OFF at any
position but 1).
ERD
Sensitivity
Min
Max
Sensitivity
ERD
Sensitivity
Min
Max
Sensitivity
x
sitiv
ax
ensitiv
a
Sensiti
a
Sensit
M
Sensi
M
Sens
M
Sen
M
S
Adjust ERD Sensitivity
ERD
Sensitivity
1-Max
2
3
4
16-Min
15
14
13
12
16 selectable positions
NO mechanical hard stop on knob
LED lights up
IMPORTANT: When satisfied
with ERD adjustment, cycle the
gate 3 or 4 times to make sure
that the ERD sensor does not
falsely trigger during normal
gate operation. Readjust if this
happens.
Maintenance and repair of the gate operator must be preformed by a qualified professional gate operator technician.
The following services need to be periodically performed:
• Check and adjust the gate operator’s force, speed, and sensitivity.
• Make sure all power (AC/DC) connections are corrosion free.
• Check all batteries for proper voltage.
• Check the incoming line voltage and confirm it is within 10% of its rating (115 or 230 volts).
• Verify battery backup functionality by turning off the power source (115 VAC and 230 VAC). Restore power after
testing.
• Cycle gate system and lubricate with heavy-duty, high-performance lubricant where needed.
• Test all contact and non-contact sensors, in-ground vehicle loop detectors, keypad, telephone entry system or any other access
control devices that are used to control the gate operator.
• Test the manual release feature.
MAKE SURE END USER/HOME OWNER KNOWS HOW TO PROPERLY REMOVE GATE OPERATOR FROM SERVICE AND WHO TO
CONTACT FOR PROFESSIONAL ASSISTANCE.
Date Installed:
Installer/Company Name:
Phone Number:
Operator
Serial Number:
Any repairs and modifications must be preformed by a qualified professional gate operator technician. If the gate or gate
operator ever malfunctions, end user/home owner needs to immediately remove the gate operator from service (manually
position gate (see manual release) in a desired prolonged position and turn ALL power OFF to the gate operator). End
user/home owner must call a qualified professional gate operator technician for any repairs and modifications.
The gate operator is virtually maintenance free to an end user/home owner, minimal maintenance is recommended to ensure
reliable operation.
End user/home owner:
• Scheduled maintenance should be performed approximately every six months by a qualified professional gate operator
technician, or when unusual noises are heard from the gate hinges and/or gate operator arm.
• DO NOT remove the operator cover to perform any normal maintenance.
• Lubricate gate hinges and gate operator arm periodically with heavy-duty, high-performance lubricant and clean up all excess
lubricant.
• Make sure there are no vehicles or pedestrians in the path of the gate while performing maintenance.
• Make sure the person performing maintenance is the only person in control of all control devices in order to avoid possible
involuntary activation of the gate operator. Gate operator MUST be removed from service while maintenance is performed.
• Keep any water from landscape watering hoses or sprinkler systems away from the gate and gate operator area.
• Keep the area around the gate and gate operator as clean as possible.
• Keep any debris away from the gate’s swinging path.
• Test periodically (use caution) all safety sensors, in-ground vehicle loop detectors, keypad, telephone entry system or any
other access control devices that are used to control the gate operator. Make sure everything is working properly.
• Solar panel must be cleaned periodically if solar power is being used.
maintenance
qualified gate operator technician
end user / homeowner
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
MAX MC-100
Motor Controller
Top View
MAX MC-100
Motor Controller
Front View
Reset
Button
Input AC Power
115VAC or 230VAC
Optional - Connects to Jog LT, Jog RT and GND
Green
White
Black
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
Optional
Open/Close
Key Switch
phantom 2000 wiring schematic
Maintenance
3-Pin
2-Pin
6-Pin
3-Pin
4-Pin
5-Pin
“Optional”
MAX Solar
Power Kit
Solar Panel 24V
to POWER/SOLAR IN
Solar
Panel
Electronics
Box
for firm grip
Hood
Factory Installed Lock
Removable Key
Unlock or unlatch
hood and remove it.
2
Make sure ALL power is OFF to operator.
1
Pull red handle up
and move gate.
3
maintenance
manual gate release
Arm
WARNING
WARNING
NEVER grasp the
arm to move gate!
Pinch Point
Arm
ALWAYS grasp gate to move it.
DO NOT Lift Arm
OFF of Operator
Optional Non-Lockable Latch
OR
Insert key on control box, turn and HOLD (in either direction) to MOVE gate.
The OPTIONAL key switch can open or close the gate electronically if the switch
has been wired to the gate operator.
• The moving gate gets PUSHED by a moving VEHICLE.
maintenance
electronic gate open / close
audible alarm
CAUTION: Keep pedestrians and vehicles clear of the gate while it is moving.
If the Alarm Sounds During Normal Gate Operation: When the gate encounters TWO consecutive
obstructions before completing a gate cycle, the alarm will sound and the gate will PAUSE in the
position where the second obstruction occurred. CHECK THE GATE AREA FOR ANY PROBLEMS
BEFORE pressing the alarm reset button on the control box to shut off the alarm and reset the gate.
NOTE: Alarm will automatically shut-off after five minutes but will not allow gate to operate until the
alarm reset button is pressed.
Some reasons why the alarm sounds:
Alarm Reset
Button
INSIDE Property
Gate is Closing
Moving Vehicle is Entering
OUTSIDE Property
• HINGES are TOO TIGHT or BROKEN, gate CANNOT move freely.
• Gate is STUCK or BENT in an awkward position.
• The gate operator tries to close the
gate but gate gets CAUGHT on an
object and cannot move.
• A FOREIGN OBJECT is on the gate
frame while the gate is moving.
• The gate is TOO HEAVY.
replacement parts list
Item
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Camlock Assembly with cover and key
Plastic Hood
Hood Latch Bracket
Output Clamp Assembly
Operator cover with nameplate
Swing arm T-Bar
Output collar and rings
Output Shaft
7Ahr Battery Module
Limit Switch Assembly
Power Supply Assembly
900:1 Double Gear Box
DC Brushless Motor
Motor Controller Assembly
External Control Box Cabinet
Matrix 1 Control Board Assembly
Swing Arm Assembly
Rotary Knob Actuator
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Maximum Controls LLC (“Manufacture”) warrants the original purchaser of this
product, for the purpose to which this product is originally installed, that the product is
free from defect in materials and/or workmanship for a period of 8 years for the
Brushless DC Motor and cover, 5 years for everything else with the exception of the
batteries which are limited to a 1 year warranty. The performance of this product is
dependent on compliance to the instructions, maintenance, operation, and testing
clearly outlined in the user manual. Failure to comply completely with those instructions
will void this warranty in its entirety. This warranty does not cover damage to the
product caused by vandalism, water damage, direct hit lightning strike, or installation
errors. This warranty does not include any labor charges that might be needed to
troubleshoot, replace, or repair a problem.
If, during the limited warranty period, one of the components exhibits a defect in
material and/or workmanship, please call 949-699-0220 before dismantling the product.
Shipping instructions and an RMA (Return Material Authorization) Number will be
issued by the factory service center when contacted. Do not send any product in for
service without an RMA number. Shipping charges to and from the factory service
center for warranty repairs are the responsibility of the customer. Repair or replacement
of any warranty items is made at the sole discretion of the Manufacturer.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO
ANY WARRANTIES OF MERCHANTABILITY AND SUITABILITY FOR A PARTICULAR
PURPOSE, ARE LIMITED TO 8 YEARS FOR THE BRUSHLESS MOTOR DC AND COVER,
5 YEARS FOR EVERYTHING ELSE WITH THE EXCEPTION OF THE BATTERIES WHICH
ARE 1 YEAR. NO IMPLIED WARRANTIES WILL EXTEND BEYOND THE WARRANTIES
LISTED ABOVE. Some states do not allow limitations on how long an implied warranty
last so this limitation might not apply to you.
This Limited warranty does not cover any problems with or relating to, the gate, the gate
hardware, including but not limited to hinges, rollers, brackets, entry devices etc. Any
service call that determines the cause of a problem to be external to the product could
result in a fee. Under no circumstances shall the manufacture be liable for
consequential, incidental or special damages arising in connection with the use, or
inability to use, this product. Under no circumstances will the Manufacture’s liability for
breach of warranty, breach of contract, negligence or strict liability exceed the cost of
the product covered other liability in connection with the sale of this product.
phantom 2000 warranty
phantom options / unique Features
gate tamper feature
“Like NO other Gate Operator in the World”
The FIRE switch is turned ONLY if
the GATE DISABLE has been turned ON.
The GATE TAMPER feature will activate the relay when a number of security circumstances occur, making illegal entry almost
impossible when the gate operator is connected to a existing building/home alarm system. The GATE TAMPER relay will activate
when:
Maximum Controls offers a MAX BC-36 Phantom Battery Module that replaces the
standard MAX BC-7 Battery Module when more battery power ONLY will be used.
This can be used with the OPTIONAL MAX solar power kit for the gate operator.
Two 12 volt 36 Amp/Hr batteries supply plenty of power to operate up to 2000 gate
cycles a day using only battery power. (your performance might vary)
max BC-36 phantom battery module - optional
The red release handle clamp is lifted and
the gate is pushed open from the closed
position without authorization.
The gate is PHYSICALLY moved from the
closed position with EXTREME force.
115V
AC
ON
POWER
OFF
MAX PS-24
POWER SUPPLY
FUSE
7 AMP
IN
Made in USA
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo
Cell
GND
Jog RT
Jog LT
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
WARNING
WARNING
connect chassis
to ground rod for
lightning protection
POWER
IN
POWER/SOLAR
IN
BATTERY
IN
www.max.us.com
Made in USA
BATTERY
PACK
TO MOTOR
CONTROLLER
E
1/2
Battery Voltage
Replace
Battery
TEST
Battery
ON/OFF
Battery
Battery IN
Error
F
MAX BC-36
Phantom
Battery Module
Gate disable feature
event history download
This unique GATE DISABLE feature is useful when the gated area needs to be secured from ALL but emergency and/or autho-
rized vehicle entry. Some examples are:
This unique EVENT HISTORY feature has an On Board Diagnostics (OBD)
port to download a simple .txt file to troubleshoot gate operator errors
and to view normal transaction logs. This file will log intermittent
problems with the gate operator that can be difficult to solve. This file
can even be e-mailed to the factory from out in the field at the job site for
additional technical support if necessary.
The event history can store up to 1000 transactions.
The GATE DISABLE feature will allow the FIRE DEPT/MAX and
RADIO inputs to operate but nothing else. It helps with some
major security problems that can occur when no one is
available to monitor the property.
“Like NO other Gate Operator in the World”
• Residential home vacation period.
• During closed hours of a business.
GATE DISABLE
prevents breaking into
a keypad box and
trying to trigger the
wires to get the gate
to open.
GATE DISABLE prevents trying to trigger
the exit loop to get the gate to open.
IMPORTANT: It is NOT recommended activating GATE DISABLE while persons are present inside the property.
Event type clarificaon:
INFO: informaonal message only
WARNING: unusual event but doesn't cause system malfuncon
ERROR: abnormal event, could cause system malfuncon
ENTRAP: entrapment detecon event
Event Report:
Fri 07/11/2014 10:59:41
INFO : Cycle Counter
Fri 07/11/2014 10:59:41
ENTRAP : SEC_MC: First ERD Detected
Fri 07/11/2014 10:59:37
INFO : Radio Input Deacvated
Fri 07/11/2014 10:59:36
INFO : Radio Input Acvated
Fri 07/11/2014 10:58:54
INFO : PRI_MC: Fully Open Posion Learned
Fri 07/11/2014 10:58:53
INFO : SEC_MC: Fully Open Posion Learned
Fri 07/11/2014 10:57:40
INFO : PRI_CIO: Communicaon Established
Fri 07/11/2014 10:57:38
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:57:34
ENTRAP : PRI_MC: Photo Cell Acvated
Fri 07/11/2014 10:57:21
INFO : Radio Input Deacvated
Fri 07/11/2014 10:57:21
INFO : Radio Input Acvated
Fri 07/11/2014 10:56:46
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2014 10:56:36
INFO : SEC_MC: Fully Open Posion Unknown
Fri 07/11/2014 10:56:36
INFO : PRI_MC: Fully Open Posion Unknown
Fri 07/11/2014 10:56:36
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Acvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Deacvated
Fri 07/11/2014 10:56:33
ENTRAP : PRI_MC: Photo Cell Acvated
Event History Text Document Sample
USB Flash Drive
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
N
RECORDER
OPEN
MAX
STOP
CLOSE
UL ALARM 12V
ALARM RET
IN US
LE
SWITCH
ON-LINE
OBD PORT
BLACK BOX
phantom options / unique Features
EXIT LOOP
Metal
Plate
Maximum Controls LLC.
27211 Burbank
Foothill Ranch, Ca 92610
Tel: (949) 699-0220
www.max.us.com
4009963
High Traffic Commercial
Brushless DC Low Profile
Swing Gate Operator
Made in USA
CONFORMS TO UL STD 325
UL CLASS - I, II, III, IV
CERTIFIED TO CAN/CSA STD
C22.2 NO. 247
Max Phantom 2000 Version 8.12.14