Rear panel switches

6 OPERATION Switching on 6 Level controls 6 Mute switches 6 Link switch 6 Level indicator 7 Limiters 7 Temperature control 7 Fault indicators 8 2 ohm LED 8 INTERNAL CONFIGURATION SWITCHES 8 FAULTS/FUSES 8 REMOTE CONTROL OPTION 9 REMOTE CONTROL SET-UP INSTRUCTIONS 10

Output power (Watts RMS) per channel

8 ohms @ 1 kHz 250 350 425 4 ohms @ 1 kHz 450 650 750 2 ohms @ 1 kHz 675 950 1200 Mono Bridged 8 ohms @ 1 kHz 900 1300 1500 4 ohms @ 1 kHz 1350 TBD 2300 THD @ rated power 4 ohms 1 kHz <0.005% <0.005% <0.005% 20Hz-20 kHz <0.03% <0.03

Your MC450, MC650 or MC750 digitally controlled power amplifier represents the latest technology in

control circuitry coupled to a no compromise high quality class AB power amplifier. There is no dynamic switching of the audio or power rails (a very common method of achieving extra power at the expense of audio quality) thus ensuring optimum sonic performance. The digital control monitors the operating parameters and adjusts the amplifier to

The inputs are made via 2 separate 3 pin XLR connectors wired in parallel. Either socket can be used as

the input, the other one can be used to link to other amplifiers (‘daisy chain’) or to the other input for mono signals. They are electronically balanced and should be connected via a high grade twin core screened cable, as follows :- PIN1 - Screen (see note) PIN2 - Hot (signal +) PIN3 - Cold (signal -) The amplifier is de

BRIDGED (MONO) OPERATION

Connect as follows : HOT - Channel A Hot COLD - Channel B Hot Leave both COLD connections open circuit, they are internally joined. NOTE: The load impedances change when operating in the bridged mode. (See Load/Power section below.) LOAD/POWER SWITCH 2 ohm/4 ohm In the 4 ohm position, the amplifier supply voltages are set up for loads of 4 ohms and above. Lower impedance loads can be connected but the internal curr

The MC750, MC650 and MC450 incorporate digitally controlled signal limiters. They attenuate the signal

via the same switch array as the level controls and introduce virtually no distortion. The attack time, release time, threshold level and operating mode can be set internally via the programming switches on the control PCB. (See the Internal Configuration section.) When the level controls are "linked" then the limiters are also linked, and when

2 ohm & Bridged LEDs

These indicate the position of the switches on the rear panel. The 2 ohm LED will also illuminate if the controller senses a low impedance load (excessive temperature rise). INTERNAL CONFIGURATION SWITCHES As these can only be accessed by removing the top panel this should only be carried out by qualified personnel. The control PCB is located on the side of the unit behind the front panel. The switches are an 8 switch DIL package at

When replacing the high current power output fuses, ensure that the supply capacitors are FULLY

DISCHARGED before inserting the new ones. If the replaced fuse blows again then there is a serious fault within the unit. Refer to a service engineer or contact your dealer. NEVER INCREASE THE RATING OF THE FUSE. REMOTE CONTROL OPTION The MC450, MC650, MC750 are internally wired for remote control, which is easily achieved by installing the appropriate

REMOTE CONTROL SET-UP INSTRUCTIONS

To set up the remote control: Connecting the system to the controlling computer - The RS485 adaptor is plugged into the back of the computer and the cable (which must be 2- core with a screen) runs from this adaptor to the 9-pin D connector on the back of the first amplifier in the sequence and then on, via 9-pin D connectors, to all other amplifiers in the system, thus creating the daisy chain link from one amplifier

MC2 Audio Amplifier Owners Instructions: