MC2 Audio MC450 Operating Instructions Manual
Text of MC2 Audio MC450 Operating Instructions Manual
2 AUDIO Ltd.,
Units 6 & 7 Kingsgate,
Heathpark Industrial Estate,
HONITON,
Devon EX14 1YG
England
Tel: ++(0)1404.44633 Fax: ++(0)1404.44660
www.mc2-audio.co.uk
Rear panel switches
6
OPERATION
Switching on
6
Level controls
6
Mute switches
6
Link switch
6
Level indicator
7
Limiters
7
Temperature control
7
Fault indicators
8
2 ohm LED
8
INTERNAL CONFIGURATION SWITCHES
8
FAULTS/FUSES
8
REMOTE CONTROL OPTION
9
REMOTE CONTROL SET-UP INSTRUCTIONS
10
Output power (Watts RMS) per channel
8 ohms @ 1 kHz
250
350
425
4 ohms @ 1 kHz
450
650
750
2 ohms @ 1 kHz
675
950
1200
Mono Bridged
8 ohms @ 1 kHz
900
1300
1500
4 ohms @ 1 kHz
1350
TBD
2300
THD @ rated power 4 ohms 1 kHz
<0.005%
<0.005%
<0.005%
20Hz-20 kHz
<0.03%
<0.03
Your MC450, MC650 or MC750 digitally controlled power amplifier represents the latest technology in
control circuitry coupled to a no compromise high quality class AB power amplifier. There is no dynamic
switching of the audio or power rails (a very common method of achieving extra power at the expense of
audio quality) thus ensuring optimum sonic performance.
The digital control monitors the operating parameters and adjusts the amplifier to
The inputs are made via 2 separate 3 pin XLR connectors wired in parallel. Either socket can be used as
the input, the other one can be used to link to other amplifiers (‘daisy chain’) or to the other input for
mono signals.
They are electronically balanced and should be connected via a high grade twin core screened cable, as
follows :-
PIN1 - Screen (see note)
PIN2 - Hot (signal +)
PIN3 - Cold (signal -)
The amplifier is de
BRIDGED (MONO) OPERATION
Connect as follows : HOT
-
Channel A Hot
COLD
-
Channel B Hot
Leave both COLD connections open circuit, they are internally joined.
NOTE: The load impedances change when operating in the bridged mode. (See Load/Power section
below.)
LOAD/POWER SWITCH 2 ohm/4 ohm
In the 4 ohm position, the amplifier supply voltages are set up for loads of 4 ohms and above. Lower
impedance loads can be connected but the internal curr
The MC750, MC650 and MC450 incorporate digitally controlled signal limiters. They attenuate the signal
via the same switch array as the level controls and introduce virtually no distortion. The attack time,
release time, threshold level and operating mode can be set internally via the programming switches on
the control PCB. (See the Internal Configuration section.)
When the level controls are "linked" then the limiters are also linked, and when
2 ohm & Bridged LEDs
These indicate the position of the switches on the rear panel. The 2 ohm LED will also illuminate if the
controller senses a low impedance load (excessive temperature rise).
INTERNAL CONFIGURATION SWITCHES
As these can only be accessed by removing the top panel this should only be carried out by qualified
personnel.
The control PCB is located on the side of the unit behind the front panel. The switches are an 8 switch
DIL package at
When replacing the high current power output fuses, ensure that the supply capacitors are FULLY
DISCHARGED before inserting the new ones.
If the replaced fuse blows again then there is a serious fault within the unit. Refer to a service
engineer or contact your dealer. NEVER INCREASE THE RATING OF THE FUSE.
REMOTE CONTROL OPTION
The MC450, MC650, MC750 are internally wired for remote control, which is easily achieved by
installing the appropriate
REMOTE CONTROL SET-UP INSTRUCTIONS
To set up the remote control:
Connecting the system to the controlling computer
-
The RS485 adaptor is plugged into the back of the computer and the cable (which must be 2-
core with a screen) runs from this adaptor to the 9-pin D connector on the back of the first
amplifier in the sequence and then on, via 9-pin D connectors, to all other amplifiers in the
system, thus creating the daisy chain link from one amplifier