A&D HL-1000WP Instruction Manual

Specifications

Brand: A&D
Category: Scale
Model: HL-1000WP (Instruction Manual), proQcyXfKfdW.
File Type: PDF
File Size: 0.74 Mb
Pages: 9 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (9 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 17/03/2026).

Read Online

Read the A&D HL-1000WP Instruction Manual online using the built-in PDF viewer.

HL-1000WP Instruction Manual: Key Pages of Document

All safety messages are identified by the following, “WARNING” or

“CAUTION”, of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows: WARNING A potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION A potentially hazardous situation which, if not avoided, may result in minor or moderate injury. ‰ This manual is subject to change without notice at any time to improve the product. ‰ Product specifications are subject to change without any obligation on the part of the manufacture. ‰ When using the HL ...

Turns the scale power on/off.

UNITS key (U.S.A. models only) Changes weighing units. RE-ZERO key Sets display to zero or subtracts weight of container. Spirit level Display Four leveling feet Battery cover Battery compartment AC adapter jack (Batteries are not included.) Rubber cap Battery cover lock U.S.A. models only 04-76.3koz 04l12.3koz 0-1.000klb 01200.0kg STABLE indicator Indicates when the reading is stable. ZERO indicator Indicates when the scale zero is correct. i t bl Weighing unit, lb-oz Weighing unit, g Weighing unit, lb NET indicator Indicates when NET weight is displayed. (Tare function is ...

Installing Batteries / Connecting The AC adapter

Installing Batteries CAUTION When replacing batteries, be careful not to apply too much force to the weighing pan. An excessive force could damage the scale. Remove the battery cover and insert six batteries (R6P / LR6 / AA size) into the battery compartment, taking extreme care to that the polarities plus and minus are observed. Be sure to lock the battery cover again after installing the batteries. AC adapter (optional) CAUTION When using an AC adapter, the scale does not comply with the IP65. The AC input requirement could be 100, 120, 220, 230 or 240 volts (50/60Hz) depending on the are ...

Automatic Power-Off Function

If the scale is left ON and the stable indicator is displayed, the automatic power-off function turns the power off after approximately 5 minutes (factory setting). To toggle the function disabled/enabled, press the [ON/OFF] key while pressing the [RE-ZERO] key. The scale stores the setting and it will be shown by pressing both the [RE-ZERO] and [UNITS] keys in the weighing mode. (See “CALIBRATION” about the [UNITS] key.) poff0e Function disabled. poff1e Function enabled. Error message eeeee Overload ----- The scale zero is out of range ealba Low battery Calibration may be required b ...

When to calibrate

Calibration may be required when the scale initially installed, if it is moved a substantial distance, or in accordance with local regulations. This is necessary because the weight of a mass in one location is not necessarily the same in another location. Also, with time and use, mechanical deviations can occur. The position of the [UNITS] key for the Calibration The “g” model has no [UNITS] key, but the key used to enter calibration is located under the overlay. Calibration using a calibration weight Calibrate the scale with calibration weights at full capacity. HL-1000WP : 1000g ± 0.1g HL-300WP: 300g ± 0.02g HL-3 ...

If you have calibration weights at the capacity of the scale, you can calibrate

the scale with the weights instead of compensating for acceleration due to gravity. The scale was calibrated at 9.798 m/sec2 , at the factory. If the acceleration due to gravity at your location is not same, compensate the scale by adjusting the acceleration due to gravity. (Refer “The Value of Gravity at Various Locations” and “World Map” and find your location value.) 1. Enter calibration mode. Press the [ON/OFF] key to turn the power off. While pressing both the [RE-ZERO] key and the [UNITS] key, press the [ON/OFF] key. Cal will be displa ...

1000 x 0.5 g

300 x 0.1 g 3000 x 1 g 2.2 x 0.001 lb 6.6 x 0.002 lb 35.28 x 0.02 oz 10.58 x 0.01 oz 105.8 x 0.1 oz Capacity x Resolution 2 lb 3.3 x 0.1 oz 6 lb 9.8 x 0.1 oz Non-linearity ±1g ±0.2g ±2g Repeatability 0.5g 0.1g 1g Span drift ±0.015% / °C TYP (5°C~35°C / 41°F~95°F) Operating temp. -10°C~40°C / 14°F~104°F, Less than 85%RH Display 13 mm / 0.51 inches, 7segment liquid crystal display Display update Approximately 10 times per second Power 6 x R6P / LR6 / “AA” size batteries or AC adapter Battery life Approximately 100 hours with manganese type 200 hours with alkal ...

Scale PDF Instructions

BF-555
Tanita BF-555
25.06.2026 13 pages

Instruction Manual Read this Instruction Manual carefully and keep it for future reference. Manuel d’instructions Lisez ce manuel d’instructions attentivement et gardez-le à portée de la main pour référence future. Manual de Instrucciones Lea cuidadosa Official user manual for the Tanita BF-555 Scale. It covers application scenarios, firmware installation, component overview.

DR150
Detecto DR150
25.04.2026 2 pages

• Large 1” LCD display • Lb/kg conversion • Battery power • Auto shutoff • Push-button tare • Available in 2 capacities DR Series Low Profile Platform Scales Digital Accuracy at a Competitive Price Bulletin No. D-255 DR Series Low Profile Pl Detailed product documentation for the Detecto DR150 Scale. The documentation guides users through setup and operation, maintenance, safety.

BFM950
Health O Meter BFM950
29.08.2026 12 pages

Professional Body Fat Monitor and Scale 34634 10/01 Model BFM950 PLEASE READ CAREFULLY AND SAVE This manual contains important information about this product’s operation. If you have purchased this product for use by others you must leave this manual – or Product instruction manual for the Health O Meter BFM950 Scale. The guide focuses on usage tips, system configuration, compatibility information.

Viper Series
Mettler Toledo Viper Series
11.05.2026 76 pages

On Off Zero Tare Sample Print Sample Size Scale Clear C Info Units Service Manual METTLER TOLEDO Viper M, L and D Scales Operating and setup manual for the Mettler Toledo Viper Series Scales. The manual highlights startup procedures, device safety checks, replacement parts, regulatory notices.