Biamp Tesira SERVER Operation Manual

Specifications

Brand: Biamp
Category: Server
Model: Tesira SERVER (Operation Manual), prH7aCP6m9cC.
File Type: PDF
File Size: —
Pages: 20 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (20 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 25/04/2026).

Read Online

Read the Biamp Tesira SERVER Operation Manual online using the built-in PDF viewer.

Tesira SERVER Operation Manual: Key Pages of Document

BIAMP SYSTEMS 9300 SW GEMINI DRIVE, BEAVERTON, OREGON 97008 U.S.A. 503.641.7287 BIAMP.COM

Tesira® 585.0278.90C MARCH  2016 SERVER SERVER  IO OPERATION  MANUAL ...

SERVER and SERVER IO Product Description

The Tesira SERVER is a digital network server. It is factory configured with one DSP-2 card and can accept up to a total of eight DSP-2 cards. The SERVER is also factory configured with one AVB-1 card and has a second slot that can be outfitted with an additional AVB-1 card, a 32 x 32 channel SCM-1 CobraNet card, a 64 x 64 channel DAN-1 Dante™ card, or a standard I/O card for four channels of local I/O. The SERVER is the core of a Tesira digital audio system and can be used with Tesira expanders to form a highly scalable audio network. Two Tesira SERVERs can also be designed as a redundant pair, carrying ident ...

Ventilation filter cover

2. Multi-color LEDs 3. Display navigation buttons 4. OLED display DISPLAY The Servers feature an OLED display that provides information about the server device as well as the Tesira system that is connected to the server. The OLED display is read-only. Navigating the display is accomplished by touch-sensitive UP and DOWN buttons and a touch sensitive SELECT button. Home Screen The home screen is the default screen that shows the overview of the device. If the text is too long to fit on the entire display, it will scroll to the left. Menus at the bottom allow other selections. By default, the main menu icon will be selected. ...

Menu Title Bar

2. Scroll Indicator 3. Previous Screen 4. Home Screen 5. Fault Menu A menu screen contains a list of items from which navigation to other menus can be selected. At the right are icons that provide quick navigation to other screens. Pressing the select button on an item in the list will transition to the screen that displays that information. A scroll indicator at the left shows there is more information to show by scrolling down. Scroll up to select from the icons at the right. The previous screen icon goes up one menu level in the menu structure. The home screen icon transitions back to the home screen. If a fault is acti ...

The display is at the [Dim display brightness]

and should appear the same except for the brightness level. Pressing any button will transition back to the previous mode and respond to the control movement (i.e. move the cursor, make a selection, etc.). Sleep Mode After the Display timeout is reached, the display will go blank. However, the Front Panel Display board and Server device still have power. LED Display The front panel of the servers displays five multi-color LEDs that provide information about the status of the servers. LED Off Green Yellow Red Power Unit is not powered Unit is powered Not applicable Not applicable Alarm No fault is ...

AC Power inlet

2. Serial Port 1 3. Serial Port 2 4. Secondary Ethernet control port (RJ-45) 5. Primary Ethernet control port (RJ-45) 6. GPIO connections 7. Slot 2; always loaded with AVB-1 digital audio networking card for AVB 8. Slot 1; optional slot that can be factory loaded or field loaded with any server card TESIRA SERVER IO 1. AC Power inlet 2. Serial Port 1 3. Serial Port 2 4. Secondary Ethernet control port (RJ-45) 5. Primary Ethernet control port (RJ-45) 6. GPIO connections 7. Slot 13; optional slot that can be factory loaded or filed loaded with AVB-1 digital audio networking card for AVB, SCM-1 digital audio networking card ...

The Tesira SIC-4 is a modular analog input card for use with Tesira SERVER and SERVER-IO devices. Each SIC-

4 provides four channels of mic or line level audio input. The inputs are electrically balanced and provided on plug-in barrier strip connectors. Software control of each input includes gain with clip indicator, +48V phantom power, mute, level and signal invert. SEC-4 The Tesira SEC-4 is a modular analog input card for use with Tesira SERVER or SERVER-IO devices. Each SEC-4 provides four channels of mic or line level audio input with Acoustic Echo Cancellation. The SEC-4 utilizes the next generation of the proprietary Sona™ algorithm and ...

Tesira SERVER Specifications (Audio specifications given reflect use of SIC-4 and SOC-4)

Frequency  Response (20Hz~20kHz  @  +4dBu): +0/-­0.25dB Phantom  Power: +48  VDC (7mA/input) THD+N  (20Hz~20kHz): @  0dB  Gain,  +4dBu  In @  54dB  Gain,  -­50dBu  In <  0.006% <  0.040% Cross  Talk  (channel  to  channel  @  1kHz): @  0dB  Gain,  +4dBu  In: @  54dB  Gain,  -­50dBu  In: <  -­85dB <  -­75dB EIN  (20Hz~20kHz,  66dB  Gain,  150Ω): <  -­125dBu Overall  Dimensions: Height: Width: Depth: Weight: 5.25  inches  (133  mm) 19.0  inches  (483  mm) 17  inches  (432  mm) 18  lbs  (8.2  kg) Dynamic  Range ...

FCC Notice - Class B digital device -

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be requir ...

This Biamp product, including all attendant cables and accessories

supplied by Biamp, meets all requirements of EU Directive 2011/65/EU. An EU RoHS Materials Content Declaration document may be obtained at www.biamp.com (This information is presented to comply with the requirements of Chinese law SJ/T11363-2006) 有害物质表 (Hazardous Substances Table) Biamp Systems Corporation 数字信号处理器 (Digital Signal Processor) 型号 SERVER, SERVER-IO 部件名称 (Part Name) 有毒有害物质或元素 (Substances) Pb 铅 Hg 汞 Cd 镉 Cr+6 六价铬 PBB PBDE 设备机箱 (Equipment Chassis) X O X O O O 电源线 (Power Cord) O O O ...

IMPORTANT SAFETY INSTRUCTIONS

Lightning Bolt: Hazardous Live voltages present when this unit is in operation. Do not touch terminals marked with this symbol while the unit is connected to live power. Exclamation Point: Replace components (i.e. fuses) only with the values specified by the manufacturer. Failure to do so will compromise safe operation of this unit Hazardous Moving Fan Blades: Remove power before servicing and keep away from moving fan blades. WARNING - To reduce the risk of fire or electric shock, do not expose these products to rain or moisture. These products must not be exposed to dripping or splashing and no objects filled with liq ...

INSTRUCCIONES DE SEGURIDAD IMPORTANTES

Rayo: Voltajes activos peligrosos mientras la unidad está en funcionamiento. No toque las terminales marcadas con este símbolo mientras la unidad se encuentre conectada a una salida activa de energía. Signo de exclamación: Reemplace los componentes (es decir, los fusibles) solo de acuerdo con los valores indicados por el fabricante. De no hacerlo, se pondrá en riesgo el funcionamiento seguro de esta unidad. Aspas de ventilador en movimiento peligrosas Desenchufe el producto antes de realizar reparaciones y aléjelo de las aspas en movimiento de los ventiladores. Explicación de los símbolos gráficos: 1) L ...

CONSIGNES DE SÉCURITÉ IMPORTANTES

Éclair : tensions dangereuses présentes lorsque l’appareil est en fonctionnement. Ne touchez pas les parties de l’appareil portant ce pictogramme tant qu’il est branché sur une ligne électrique. Point d’exclamation : remplacez les composants (fusibles, par exemple) uniquement par des composants possédant les caractéristiques spécifiées par le fabricant sous peine d’altérer le bon fonctionnement de l’appareil. Danger : pales de ventilateur en mouvement. Coupez l’alimentation avant toute intervention et restez à distance des pales en mouvement. Signification des pictogrammes: 1) Lisez attenti ...

Blitz: Beim Betrieb dieses Geräts entstehen lebensgefährliche Spannungen. Berühren Sie keine Anschlüsse mit

diesem Symbol, während das Gerät an ein Netzteil mit eingeschalteter Spannungsversorgung angeschlossen ist. Ausrufezeichen: Ersetzen Sie Bauteile (z. B. Sicherungen) nur entsprechend den vom Hersteller angegebenen Werten. Bei Missachtung ist die Sicherheit dieses Geräts nicht mehr gewährleistet. Rotierende Lüfterflügel: Vor Wartungsarbeiten Stromversorgung unterbrechen und von beweglichen Lüfterflügeln fernhalten. Erklärung grafischer Symbole: 1) Lesen Sie diese Hinweise. 2) Bewahren Sie diese Hinweis ...

重要安全说明 闪电:此设备运行时会伴随有危险的实时电压。当设备与电源连接时,不要触碰带有此符号的端子。 惊叹号:只能按照厂商指定的技术参数更换组件(例如:保险丝)。 否则,将会降低本设备的运行安全性。 危险的移动风扇叶片:请在提供服务之前切断电源,并与移动风扇叶片保持距离。 图形符号解释: 1) 阅读这些说明。 2) 妥善保管这些说明。 3) 留意所有警告。 4) 遵守所有说明。 5) 不得在靠近水源处使用本产品。 6) 只能用干布进行清洁。 7) 不要堵塞通风口。按照厂商� ...

중요 안전성 지침

번개 표시: 본 장비가 작동 중일 때는 위험한 전압이 발생합니다. 본 장비가 전원에 연결되어 있는 동안에는 이 기호가 표시된 터미널에 손을 대지 마십시오. 느낌표: 구성 부품(예:퓨즈)은 제조업체에 의해 지정된 사양으로만 교환합니다. 그렇지 않으면 본 장비의 안전한 작동에 문제가 생길 수 있습니다. 위험한 이동식 송풍기 블레이드: 전원을 끄고 나서 서비스를 제공하고, 이동식 송풍기 블레이드를 가까이 두지 마십시오. 그래픽 기호 설명: 1) 이 지침서를 읽으십시오. 2) � ...

تعليمات سالمة هامة

صاعقة كهربائية: تظهر الفولطية الخطرة على الحياة عندما تعمل هذه الوحدة. ال تلمس األطراف المعلمة بهذا الرمز عندما تكون الوحدة موصله بمصدر طاقة نشط عالمة تعجب: ال تستبدل المكونات (مثل الصمامات الكهربائية ) إال بالقيم المحددة من قبل الشركة المصنعة. القيام بغير ذلك من شأنه أن يهدد التشغيل اآلمن لهذه الوحدة خطورة شفرات المروحة المتحركة: افصل ا ...

IMPORTANTES INSTRUÇÕES DE SEGURANÇA

Relâmpago: Tensões perigosas presentes quando esta unidade estiver em operação. Não toque nos terminais marcados com este símbolo enquanto o aparelho estiver conectado na corrente elétrica. Ponto de Exclamação: Substitua os componentes (ou seja, fusíveis), apenas com os valores especificados pelo fabricante. Não fazer isso, irá comprometer a operação segura deste aparelho. Lâminas do Ventilador em Movimento Perigoso: Desligue a alimentação antes da manutenção e mantenha-se afastado do movimento das pás do ventilador. Explicação dos Símbolos Gráficos: 1) Leia estas instruções. 2) Guarde e ...

ВАЖНЫЕ ИНСТРУКЦИИ ПО ТЕХНИКЕ БЕЗОПАСНОСТИ

Разряд молнии: наличие опасного для жизни напряжения во время работы данного устройства. Не прикасайтесь к контактам, обозначенным этим символом, когда устройство подключено к питанию. Знак восклицания: заменяйте компоненты (например, предохранители) только компонентами с характеристиками, рекомендованными прои� ...

Biamp’s Limited Warranty

BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL END USER CUSTOMER OF THE PRODUCTS DESCRIBED IN THIS MANUAL 1. This limited warranty is being offered by Biamp Systems Corporation. Biamp Systems warrants to the original end user customer of new Biamp Systems products from an authorized Biamp Systems dealer that the product will be free from defects in materials and workmanship for a specified period (the “Warranty Period”), subject to the terms and conditions set forth below. The Warranty Period for the products described in this manual shall be five (5) years. The Warranty Period ...

Server PDF Instructions

Integrity BL890c i2
HP Integrity BL890c i2
17.06.2026 23 pages

HP Version Control 6.1.0 Release Notes HP Part Number: 358191-406 Published: March 2010 Edition: 19 Step-by-step user manual for the HP Integrity BL890c i2 Server. It offers guidance for setup and installation steps, daily usage, user instructions.

6950 EGS
Intermec 6950 EGS
16.04.2026 144 pages

6950 Enterprise Gateway Server USER’S GUIDE                             PN: 961-047-091     Instruction and usage manual for the Intermec 6950 EGS Server. This guide presents instructions on safety information, technical guidelines, replacement parts, power requirements.

NOD32 ANTIVIRUS - FOR LINUX-BSD MAIL SERVER
ESET NOD32 ANTIVIRUS - FOR LINUX-BSD MAIL SERVER
24.08.2026 46 pages

NOD32 for Linux/BSD Mail Server Installation Manual and User’s documentation we protect digital worlds Product setup manual for the ESET NOD32 ANTIVIRUS - FOR LINUX-BSD MAIL SERVER Server. The document contains troubleshooting tips, technical troubleshooting, adjustment procedures.

NAS-235
AirLive NAS-235
01.04.2026 89 pages

NAS-235 AirLive 2Bay DiskMaster User’s Manual User reference guide for the AirLive NAS-235 Server. It outlines maintenance guidelines and installation procedures, dimensions and layout, usage procedures, safety protocols.