Time Guard NTT06 Installation & Operating Instructions Manual
Text of the manual
Installation & Operating Instructions
Digital Time Switch
Model: NTT06
24 Hour General Purpose
Digital Timer
Model: NTT07
7 Day General Purpose
Digital Timer
This time switch is an easy to use digital timer,
designed for wall mounting. It can control outputs
of up to 16A which makes it suitable for domestic
immersion heaters.
The NTT06/7 comes with a link in place which can
be removed to provide volt free contacts if required,
making it suitable for a wider range of switching
applications. If volt f
4 ON/OFF switching programmes, which for
NTT07 can be made to operate over all 7 days
(24 hour operation), 5 weekdays 2 weekend days,
or any individual day (7 day operation). For the
NTT06, 24 hour programming is the only option.
Advance feature advances to next
programmed operation.
Boost feature provides 1 or 2 hour boost.
Battery back up re
The time switch has a factory fitted rechargeable
battery to give clock operation and programme
memory back up during loss of mains supply.
Before programming for the first time, connect the
unit to the mains for at least 15 minutes prior to
pressing the Rst button and programming the unit.
If the display is not visible or very faint, charge fo
The time switch must be reset before programming for
the first time, or after subsequent discharge for more
than 5 days, and following a 4 hour period of charging.
Press Rst using a pointed object,
eg: a pencil. The display will show all
the segments, and then clear to show:
Use the Adv/Ovr button to change
between on and off for the automatic
su
Use the Adv/Ovr or boost button to
adjust the hour to the correct hour.
Press Time to set the hour, and then
the time will show the minutes. The
hour is a 24 hour clock.
Use the Adv/Ovr or boost button
to adjust the minutes to the
correct minutes.
Press Time to exit the Time/date entry
mode. The display should now show
the correct time/day of the week.
7.
The NTT06/07 has 4 independent On/Off periods
available for programming each day. For the NTT07 there
is a choice of programming options, including 7 days the
same (24 hours), 5 + 2 days (where the weekdays are
the same, and the two weekend days are the same),
and 7 individual days. For the NTT06, 24 hours is the
only option, s
Press Prg to change to
programme 1 off time.
Press Prg to scroll through
programme 2 on, programme 2 off,
programme 3 on, programme 3 off,
programme 4 on and programme 4 off,
adding in times as required.
If times are not required, just leave the dashes in
place, and scroll past that programme.
After programme 4 has been entered, the day will
index to the n
Enter the required programme on time.
Enter the programme off time as 00:00
Enter the first programme on time for the
next day as 00:00
Enter the required programme off time.
Note: for 24 hour the on period for programme 1
must start 00:00.
9. Modifying or adding
programmes:
Press Prg and hold for 3 seconds. Whilst holding,
In operating mode Adv/Ovr advances the programme
to the next change. If the output is off, it will change
the output to on, until the next programmed off
time. If the output is on, it will change the output
to off, until the next programmed on time.
A second push of the Adv/Ovr button selects a
permanently on mode, where the output is