Installation & Operating Instructions

Digital Time Switch Model: NTT06 24 Hour General Purpose Digital Timer Model: NTT07 7 Day General Purpose Digital Timer

This time switch is an easy to use digital timer,

designed for wall mounting. It can control outputs of up to 16A which makes it suitable for domestic immersion heaters. The NTT06/7 comes with a link in place which can be removed to provide volt free contacts if required, making it suitable for a wider range of switching applications. If volt f

4 ON/OFF switching programmes, which for

NTT07 can be made to operate over all 7 days (24 hour operation), 5 weekdays 2 weekend days, or any individual day (7 day operation). For the NTT06, 24 hour programming is the only option. Advance feature advances to next programmed operation. Boost feature provides 1 or 2 hour boost. Battery back up re

The time switch has a factory fitted rechargeable

battery to give clock operation and programme memory back up during loss of mains supply. Before programming for the first time, connect the unit to the mains for at least 15 minutes prior to pressing the Rst button and programming the unit. If the display is not visible or very faint, charge fo

The time switch must be reset before programming for

the first time, or after subsequent discharge for more than 5 days, and following a 4 hour period of charging. Press Rst using a pointed object, eg: a pencil. The display will show all the segments, and then clear to show: Use the Adv/Ovr button to change between on and off for the automatic su

Use the Adv/Ovr or boost button to

adjust the hour to the correct hour. Press Time to set the hour, and then the time will show the minutes. The hour is a 24 hour clock. Use the Adv/Ovr or boost button to adjust the minutes to the correct minutes. Press Time to exit the Time/date entry mode. The display should now show the correct time/day of the week. 7.

The NTT06/07 has 4 independent On/Off periods

available for programming each day. For the NTT07 there is a choice of programming options, including 7 days the same (24 hours), 5 + 2 days (where the weekdays are the same, and the two weekend days are the same), and 7 individual days. For the NTT06, 24 hours is the only option, s

Press Prg to change to

programme 1 off time. Press Prg to scroll through programme 2 on, programme 2 off, programme 3 on, programme 3 off, programme 4 on and programme 4 off, adding in times as required. If times are not required, just leave the dashes in place, and scroll past that programme. After programme 4 has been entered, the day will index to the n

Enter the required programme on time.

Enter the programme off time as 00:00 Enter the first programme on time for the next day as 00:00 Enter the required programme off time. Note: for 24 hour the on period for programme 1 must start 00:00. 9. Modifying or adding programmes: Press Prg and hold for 3 seconds. Whilst holding,

In operating mode Adv/Ovr advances the programme

to the next change. If the output is off, it will change the output to on, until the next programmed off time. If the output is on, it will change the output to off, until the next programmed on time. A second push of the Adv/Ovr button selects a permanently on mode, where the output is