OM POWER OM3500A Instruction Manual
Text of OM POWER OM3500A Instruction Manual
SHORTWAVE POWER AMPLIFIER
OM POWER, s. r. o. 930 30 Báč 126
SLOVAKIA
Important safety instructions:
• The amplifier contains high voltage circuits. Never turn the amplifier on
without the upper lid in place.
• The OM3500A amplifier is neither to be used in a wet or humid environment
nor to be exposed to rainfall.
• The amplifier must be installed in such a way that free flow of hot air from
the tube is allowed. The amplifier must not be installed in a constrained
surrounding (i.e. tight shelves etc.)
• During long o
General description of the OM3500A Amplifier
The linear amplifier OM 3500A is designed for all short wave amateur bands from 1.8 till 29
MHz (including WARC – bands ) and all modes . It is equipped with a ceramic tetrode
GU78b. The OM3500A is automatically tuned to operating frequency of your TRX.
Specification of OM3500A
Frequency coverage: amateur bands 1.8 – 29.7 MHz including WARC
Power output: 3500 W in SSB
General Description of OM3500 A POWER AMPLIFIER
HF PART
In this amplifier a tetrode GU 78b is used in a grounded-cathode circuit (input into control grid). This
amplifier achieves excellent linearity by the voltage stabilization of the control grid bias and the screen
voltage. The power input is given to the control grid, using a broadband input circuit with an input
impedance of 50 Ohms. This adaptable input circuitry ensures a good input SWR better than
Power supply of the amplifier is effected by two 2,5 kVA toroidal transformers. A soft start is
realized with the help of relays and resistors.
The high anode voltage consists of 8 times 420V and 2A. Each of them has its own rectifier and filter.
In the high voltage circuit safety resistors are employed to protect the amplifier against overload.
The source for screen grid is stabilized by a parallel stabilization with BU508 transistors and de
The amplifier is connected to the mains with 2 cables with a EURO end. Each cable is to be
switched to another phase of your main supply system! Both of them have to be able to deliver a
power of 2.5 kVA !
If you use only one phase, you have to connect both cables to this one phase ! Your main supply
has to be able to deliver 5 kVA on this one phase! In this case the power amplifier can’t deliver
full output!
ATTENTION:
In each case the pow
Control of the amplifier is possible remotely by using REMOTE BOX (optional). Connection
is done by REMOTE socket, maximum cable length of 10 meters.
I / O box
.
Control of Amplifier and communication with TRX as well as antennas / BPF switching can
be done via I / O Interface
KEY IN
- Input signal PTT (switching voltage / current 5V / 2mA)
KEY OUT
- Output signal PTT (maximum switching of 30V / 50mA)
Control cable
Control cable maintains TX /
- Mono 3.5mm Jack for connection of ICOM TRXs. For successful
operation selection of ICOM radio and correct baud rate is important
(9600 default)
TCVR
- DB-9 -serial port RS232 for YAESU, KENWOOD, ORION and
ELECRAFT TRXs. Correct baud rate and TRX type is a must for
successful operation. If both CI-V and TCVR cables are used then CI-V
wins over RS232. Otherwise selection of interface is done via TRX
type.
PC
- DB9 RS232 port is used for communication