Schluter Systems DH E RT 102/BW Operation & User’s Manual
Read Online
Read the Schluter Systems DH E RT 102/BW Operation & User’s Manual online using the built-in PDF viewer.
Key Pages of Document
DH E RT 102/BW Programmable Interactive User Manual 67504A 11/15 (ALA) ...
1. Contents 2. Menu Overview . . . . . . . . . . . . . . 3 3. Introduction . . . . . . . . . . . . . . . . 4 4. General Operation . . . . . . . . . . . . 5 4.1.Navigation Buttons . . . . . . . . . . 6 5. Ground Fault Circuit Interrupter (GFCI) 1/2 . . . . . . . . . . ...
Installer Settings 2. Menu Overview Menu Structure Menu Heating Schedule User Settings ...
3. Introduction Congratulations on the purchase of your new touch thermostat. We hope that you will enjoy the ease of use offered by the touchscreen and the intuitively designed user interface. You can program the thermostat in any way you would like with the options provided under Heating Schedule and User Settings. The thermostat will switch your underfloor heating system o ...
The thermostat has two physical buttons. A ground fault circuit interrupter (GFCI) test button is located on top of the thermostat, and a power/reset button is located on the right side of the thermostat. The GFCI should be tested monthly (all settings, including time and date, will be remembered). The thermostat is an intuitively operated touch thermostat in which the touchs ...
4.1.Navigation Buttons Accept/Back/Cancel/Arrow Up/Arrow Down/Arrow Left/Arrow Right Whenever you change a parameter setting, you must tap the “Accept” button for the thermostat to acknowledge the change. “Accept” is shown on the screen as “√”. “Back” is shown on the screen as a button marked with a hollow arrow pointing to the left. In the various menus and ...
The thermostat has a built-in GFCI that ensures personal safety in case of ground faults. It is important that the GFCI is tested monthly. Installation and use must be according to the national and local regulations. Testing the GFCI: Press the “TEST” button. The test is successful if the red LED on the right of the thermostat flashes once every two seconds and “GROUND ...
The red LED on the right of the thermostat can indicate four different GFCI states: 1. LED off – NORMAL state. 2. LED flashing slowly (once every two seconds) – TRIGGERED state. Try pressing the “Standby/Reset” button to reset the GFCI. 3. LED flashing quickly (five flashes per second) – ERROR state. Try switching the power off and then back on again. If the th ...
6. Icons 1/2 Menu Heating Schedule Energy Use User Settings Installer Settings Child Lock Display Brightness Screen Saver en saver Icon Meaning Energy Tariff Date Time Daylight Saving Time Unit Language Information Support $ 7 5° Icon Meaning Adaptive Function Open Window Sensor Application Sensor Type Floor Protection Floor Sensor Calibration Room Sensor Calibration Tempera ...
6. Icons 2/2 Factory Reset Accept Back Cancel Arrow Up Arrow Down Arrow Left Arrow Right screen saver + screen saver + Icon Meaning Copy to “Adjust… for a few days” in the future is activated Heating is activated Heating is activated with adaptive mode Note screen saver + screen saver + screen saver + screen saver + screen saver + Icon Meaning ...
7. Startup Wizard When the system has been installed and turned on for the first time, or after you have performed a factory reset, the system will run a Startup Wizard. The Wizard will take you through tests, which ensure that the thermostat is fully functional. After the tests, the Wizard leads you through a basic setup routine to ensure that you have the right settings. ...
7.1 Set the language First you must set the language. The chosen language will become the default language for the thermostat. The language can be changed under Menu/User Settings/Language. 1. Tap the language you prefer. 2. Tap the “Arrow Right” button to continue. 1 2 ...
7.2 System Test System Test is an automatic test of the thermostat and sensors. If a test results in ‘Fail,’ please contact your installer. Note: if the thermostat is to operate with an air/room sensor only, the floor sensor test will result in ‘Fail’ being shown. 1. Tap the “Arrow Right” button to continue. 1 ...
7.3 GFCI Test 1. Press the test button on the top of the thermostat. The test is successful if the red light in the test button lights up and a GFCI error text is shown on the display. 2. Press the power/reset button on the lower right side of the thermostat to reset the GFCI. 3. Tap the “Arrow Right” button to continue. ...
7.4 Set the preferred temperature unit 1. Tap the temperature unit that you prefer. 2. Tap the “Arrow Right” button to continue. The temperature unit can be changed under Menu/User Settings/Unit 1 2 ...
7.5 Set the floor load 1. Set the load of the underfloor heating system to be controlled by the thermostat. 2. Tap the “Arrow Right” button to continue. This setting can be changed later if a factory reset is performed. 1 2 ...
Choose which floor sensor type is used with the thermostat. 1. Tap the sensor type installed in the floor. 2. Tap the “Arrow Right” button to continue. If you want to use the thermostat with the room sensor only, you must complete the Setup Wizard using “Default” as the floor sensor type before going to: Menu/ Installer Settings/Sensor Application and choosing “R ...
7.7 Set the date 1. Tap the “Arrow” buttons to change the values. 2. Tap the preferred date format. 3. Tap the “Arrow Right” button to continue. The date can be changed under Menu/User Settings/Date 3 2 1 ...
7.8 Set the time 1. Tap the “Arrow” buttons to change the values. 2. Tap the preferred time format. 3. Tap the “Arrow Right” button to continue. The time can be changed under Menu/User Settings/Time 3 2 1 ...
7.9 Set floor protection Set the floor protection according to the floor type. 1. Tap the preferred limits that are used to protect the floor. 2. Tap “√” to continue Floor protection settings can be changed under Menu/Installer Settings/Floor Protection. 1 2 ...