Sharp R-3S56 Service Manual

Text of Sharp R-3S56 Service Manual

In interests of user-safety the oven should be restored to its original

condition and only parts identical to those specified should be used. MODEL R-3S56 S9510R3S56PX/ MICROWAVE OVEN TABLE OF CONTENTS Page CAUTION, MICROWAVE RADIATION................................................................................................................. 1 WARNING ..........................................................

FUNCTION OF IMPORTANT

COMPONENTS OPERATING SEQUENCE APPEARANCE VIEW MICROWAVE MEASUREMENT WIRING DIAGRAM PARTS LIST TOUCH CONTROL PANEL ASSEMBLY COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE MICROWAVE OVEN R-3S56 GENERAL IMPORTANT INFORMATION This Manual has been prepared to provide Sharp Corp. Service engineers with Operation

Sharp R-3S56 Single phase, 3 wire earthed

Power Consumption 1.06 kW, Approx. 4.9A Power Output 700 watts nominal of RF microwave energy (IEC 705) Operating fequency 2450 MHz Case Dimensions Width 450 mm Height 295 mm including foot Depth 361 mm Cooking Cavity Dimensions Width 285 mm Height 178 mm Depth 313 mm Turntable diameter 272mm Control Complement Touch Control System Timer (0 - 99 minutes 90 seconds

1. Ventilation opening

2. Oven lamp 3. Door hinges 4. Door safety latches 5. See through door 6. Coupling 7. Door open button 8. Touch control panel 9. Digital read-out 10.Wave guide cover 11.Power supply cord 12. Earth wire TOUCH CONTROL PANEL a. TIME PADS Press to enter cooking time. b. AUTO COOK PAD Press to select AUTO COOK menu. c. POWER LEVEL/SERVES PAD Press to select microwave power setting. If not pressed, 100% is automati

Closing the door activates all door interlock switches

(1st. latch switch, 2nd. latch switch and stop switch). IMPORTANT When the oven door is closed, the monitor switch contacts (COM-NC) must be open. When the microwave oven is plugged in a wall outlet, rated voltage is supplied to the point A3+A5 in the control unit. Figure O-1 on page 25 1. The display shows " 0". NOTE: When the oven door is opened, the oven l

Sharp R-3S56 DOOR OPEN MECHANISM

The door is opened by pushing the open button on the control panel, When the open button is pushed, the switch lever on the latch hook is moved upward, operating the latch head. The latch head is moved upward, and released from latch hook. Now, the door can be opened. LATCH HOOK 1ST. LATCH SWITCH 2ND. LATCH SWITCH MONITOR SWITCH LATCH HEADS SWITCH LEVER DOOR OPEN BUTTON DOOR STOP SWITCH Figure D-1. Door Open Mechanism 1ST. LATC

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of producing very high voltage and current, contact with any part of the high voltage circuit will result in electrocution. High voltage capacitor, Power transformer, Magnetron, High voltage rectifier assembly, High voltage harness. REMEMBER TO CHECK 3D 1) Disconnect the supply. 2) Door opened, and wedged open. 3) Discharge high voltage capacitor. WARNING: AGAINST T

Sharp R-3S56 Home fuse blows when power

supply cord is plugged into wall outlet. FUSE M6.3A blows when power supply cord is plugged into wall outlet. " 0" does not appear in dis- play but power supply cord is plugged into wall outlet. Display does not operate properly when STOP/CLEAR pad is touched. Oven lamp does not light at door opened. (Display ap- pears.) Oven does not start when the START pad is touched. (Dis- play appears) Oven lamp does not light (Di

CARRY OUT 3D CHECKS.

Isolate the magnetron from high voltage circuit by removing all leads connected to filament terminal. To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the meter should show a reading of less than 1 ohm. To test for short filament to anode condition, connect ohmmeter between one of the filament terminals and the case of the

6. Measure the final water temperature. (Example: The final temperature T2 = 21°C)

7. Calculate the microwave power output P in watts from above formula. Initial temperature .................................................................................................. T1 = 11°C Temperature after (60 + 2) = 62 sec. ..................................................................... T2 = 21°

TEST PROCEDURES (CONT'D)

PROCEDURE LETTER COMPONENT TEST CARRY OUT 4R CHECKS. NOTE: FOR MEASUREMENT OF THE RESISTANCE OF THE RECTIFIER, THE BATTERIES OF THE MEASURING INSTRUMENT MUST HAVE A VOLTAGE AT LEAST 6 VOLTS, BECAUSE OTHERWISE AN INFINITE RESISTANCE MIGHT BE SHOWN IN BOTH DIRECTIONS. D HIGH VOLTAGE CAPACITOR TEST CARRY OUT 3D CHECKS. A. Isolate the high voltage capacitor from the circuit. B. Continuity check must be carried out with measur
TEST PROCEDURES (CONT'D) If incorrect readings are obtained, replace the temp. fuse or thermal cut-out. An open circuit temperature fuse (MAG.) indicates that the magnetron has overheated, this may be due to resistricted ventilation, cooling fan failure. An open circuit temperature fuse (OVEN) indicates that the oven cavity has overheated, this may be due to no load operation. An open circuit thermal cut-out 95˚C
TEST PROCEDURES (CONT'D) PROCEDURE LETTER COMPONENT TEST d) The corresponding segments of all digits do not light up or they continue to light up. e) Wrong figure appears. f) A certain group of indicators do not light up. g) The figure of all digits flicker. 2-3 Other possible problems caused by defective control unit. a) Buzzer does not sound or continues to sound. b) Cooking is not possible. If the display fails to clear when the STOP/CLEAR ta
TEST PROCEDURES (CONT'D) PROCEDURE LETTER COMPONENT TEST NOTE: At the time of these repairs, make a visual inspection of the varistor for burning damage and examine the transformer with tester for the presence of layer short-circuit (check primary coil resistance). If any abnormal condition is detected, replace the defective parts. CARRY OUT 4R CHECKS. STEPS OCCURANCE CAUSE OR CORRECTION 1 The rated voltage is not applied to POWER terminal of C

TOUCH CONTROL PANEL ASSEMBLY

OUTLINE OF TOIUCH CONTROL PANEL Control Unit Control unit consists of tact switches, LSI, power source circuit, synchronizing signal circuit, ACL circuit, buzzer circuit and indicator circuit. 1) Tact Switches The tact switches are composed of a matrix, signals generated in the LSI are sent to the tact switches through R60-R62. When a tact switches is touched, a signal is completed through the tact switches and passed

DESCRIPTION OF LSI

LSI(IZA588DR): The I/O signal of the LSI(IZA588DR) is detailed in the following table. Pin No. Signal I/O Description 1 XOUT OUT Internal clock oscillation frequency control output. Output to control oscillation input of XOUT. 2 XIN IN Internal clock oscillation frequency input setting. The internal clock frequency is set by inserting the ceramic filter oscillation circuit with respect to XIN terminal. 3 RESET IN Auto clear ter

Signal coming from touch tact switch.

When either one of resistor R93 line switches on switch matrix is touched, a corresponding signal will be input into R81. 22 R82 IN Signal coming from touch tact switch. When either one of resistor R92 line switches on switch matrix is touched, a corresponding signal will be input into R82. 23 R83 IN Signal coming from touch tact switch. When either one of resistor

1. Precautions for Handling Electronic Components

This unit uses CMOS LSI in the integral part of the circuits. When handling these parts, the following pre- cautions should be strictly followed. CMOS LSI have extremely high impedance at its input and output termi- nals. For this reason, it is easily influenced by the surrounding high voltage power source, static electricity charge in clothes, etc, and sometimes it is not fully protecte

COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE

WARNING: Avoid possible exposure to microwave energy. Please follow the instructions below before operating the oven. 1. Door does not close firmly. 2. Door hinge, support or latch hook is damaged. 3. The door gasket or seal or damaged. 4. The door is bent or warped. 5. There are defective parts in the door interlock system. 6. There are defective parts in the microwave generating and transmission a

Sharp Microwave Oven Owners Instructions: