USER GUIDE 600A True RMS Digital Clamp Meters EX650 Series EX650 True RMS 600A AC Digital Clamp Meter EX655 True RMS 600A AC/DC Clamp Meter with Temperature, Inrush, and Low Pass Filter
EX65x‐en‐GB_V1.6   7/16 2 Table of Contents 1. INTRODUCTION 3 2. SAFETY INFORMATION 4 3. DESCRIPTIONS 6 4. OPERATION 11 Powering the Meter 11 Disable Auto Power OFF 11 Display Backlight 11 Work Light 11 Data Hold 12 Test Lead Considerations 12 Voltage Measurements 12 ‘Lo Z’ AC Voltage Measurements 15 Current Measurements Using the Clamp 16 µA AC/DC Current Measurements using Test Leads 18 Non‐Contact Voltage Dete
EX65x‐en‐GB_V1.6   7/16 3 1.  Introduction Thank you for selecting the Extech EX650 Series Clamp Meter. The EX650 is a feature‐packed True RMS digital Clamp meter series with 6000 count backlit display and automatic ranging. Measure AC/DC voltage, AC current, DC current (EX655), Inrush current (EX655), Resistance, Diode, Continuity, Capacitance, Temperature (EX655), Lo ‘Z’ low impedance mode, and
EX65x‐en‐GB_V1.6   7/16 4 2. Safety Information To ensure the safe operation and service of the meter, follow these instructions closely. Failure to observe warnings can result in severe injury.  WARNINGS WARNINGS identify hazardous conditions and actions that could cause BODILY HARM or DEATH.  When handling test leads or probes, keep hands and fingers behind the finger guards at all times. To a
EX65x‐en‐GB_V1.6   7/16 5 Safety Symbols that are typically marked on meters and instructions This symbol, adjacent to another symbol, indicates the user must refer to the manual or user guide for further information. Risk of electrical shock  Fuse symbol Equipment protected by double or reinforced insulation Low Battery symbol Conforms to EU directives Do not discard this product in household trash.
EX65x‐en‐GB_V1.6   7/16 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3. Descriptions Meter Description (EX655 pictured) 1. Non‐Contact Voltage Detector 2. Clamp jaw 3. Work Light ON/OFF button 4. NCV alert LED lamp 5. Rotary function switch 6. Max‐Min button 7. Relative , DCA  Zero, and Inrush button (DCA  Zero & Inrush on EX655 only) 8. LCD multi‐function display with backlighting 9. Positive input terminal 10. Common

1 2 3 4 5

6 7 8 9 10 11 12 13 14 15 16 Fig 3‐2 EX650 METER DISPLAY 1. High voltage 2. Battery status 3. Relative mode 4. Auto power off 5. Data hold 6. Units of measure 7. Direct Current 8. Alternating Current 9. Diode 10. Continuity 11. Automatic range 12. Low Impedance mode (Lo Z) 13. Maximum and Minimum memory 14. Non‐Contact Voltage Detector 15. Low Pa