Klein Tools CL310 Instruction Manual

Text of the manual

Dwg Name: CL310-1390115ART

Dwg No: 1390115 ECO No: 20550 Rev: D Pkg Dwg Ref: 1290186 Color Reference: N/A INSTRUCTION MANUAL ENGLISH CL310 FRANÇAIS pg. 37 ESPAÑOL pg. 19 400A AC Auto-Ranging Digital Clamp Meter True RMS Measurement Technology 600V 400A 40MΩ • AUTO-RANGING • DATA HOLD • RANGE HOLD • TEMPERATURE • AUDIBLE CONTINUITY CL310-1390115ART.indd 1 10/1/2015 3:43:24 PM

Dwg Name: CL310-1390115ART

Dwg No: 1390115 ECO No: 20550 Rev: D Pkg Dwg Ref: 1290186 Color Reference: N/A 2 GENERAL SPECIFICATIONS Klein Tools CL310 is an automatically ranging true root mean square (TRMS) digital clamp meter that measures AC current via the clamp, AC/DC voltage, resistance, continuity, frequency, capacitance, and tests diodes via test-leads, and temperature via a thermocouple probe. • Operating Altitude: 6562 ft. (2000m) • Relative Humidity: <95% non-condensing • Operating Temp: 32° to 122°F (0° to 50°C) • Storage Temp: 14° to 122°F (-10° to 50°C) • Accuracy: Values stated at 65° to 83°F (18° to 28°C) • Temp Coeffcient: 0.1 x (Quoted Accuracy) per °C above 28°C or below 18°C, corrections are required when ambient working temp is outside of Accuracy Temp range • Dimensions: 8.66" x 3.03" x 1.61" (220 x 77 x 41 mm) • Weight: 9.88 oz. (280 g) including batteries • Calibration: Accurate for one year • Standards: Conforms to: UL 61010-1, UL 61010-2-032, UL 61010-2-033. Certified to: CAN/CSA C22.2 NO. 61010-1, 61010-2-032, 61010-2-033, IEC EN 61010-1, 61010-2-032, 61010-2-033, IEC EN 61326-1. • Pollution degree: 2 • Accuracy: ± (% of reading + # of least significant digits) • Drop Protection: 3.3 ft. (1m) • Safety Rating: CATIII 600V, Class 2, Double insulation • Electromagnetic Environment: IEC EN 61326-1. This equipment meets requirements for use in basic and controlled electromagnetic environments like residential properties, business premises, and light-industrial locations. Specifications subject to change. ENGLISH CL310-1390115ART.indd 2 10/1/2015 3:43:25 PM

Dwg Name: CL310-1390115ART

Dwg No: 1390115 ECO No: 20550 Rev: D Pkg Dwg Ref: 1290186 Color Reference: N/A 3 ELECTRICAL SPECIFICATIONS Function Range Resolution Accuracy AC Voltage (V AC) 4.000V 1mV ±(1.5% + 5 digits) 40.00V 10mV ±(1.2% + 5 digits) 400.0V 100mV 600V 1V ±(1.5% + 5 digits) DC Voltage (V DC) 400.0mV 0.1mV ±(1.0% + 8 digits) 4.000V 1mV ±(0.8% + 3 digits) 40.00V 10mV 400.0V 100mV 600V 1V ±(1.0% + 3 digits) Input Impedance: 10MΩ Frequency Range: 45 to 400Hz Maximum Input: 600V AC RMS or 600V DC AC Current (A AC) 4.000A 1mA ±(2.5% + 30 digits) 40.00A 10mA ±(2.5% + 10 digits) 400.0A 100mA ±(2.0% + 10 digits) Frequency Range: 50 to 60Hz Resistance 400.0Ω 0.1Ω ±(1.2% + 5 digits) 4.000KΩ 1Ω ±(1.2% + 3 digits) 40.00kΩ 10Ω 400.0kΩ 100Ω 4.000MΩ 1kΩ 40.00MΩ 10kΩ ±(2.0% + 5 digits) Maximum Input: 600V AC RMS or 600V DC CL310-1390115ART.indd 3 10/1/2015 3:43:25 PM

Dwg Name: CL310-1390115ART

Dwg No: 1390115 ECO No: 20550 Rev: D Pkg Dwg Ref: 1290186 Color Reference: N/A 4 OTHER MEASUREMENT APPLICATIONS Maximum Input: 600V DC or 600V AC RMS • Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC • Continuity Check: Audible signal <10Ω, max current 1.5mA • Sampling Frequency: 3 samples per second • Auto Power off: After ~15 minutes of inactivity. • Overload: "OL" indicated on display • Polarity: "-" on display indicates negative polarity • Display: 3-3/4 digit, 4000 Count LCD ELECTRICAL SPECIFICATIONS Function Range Resolution Accuracy Capacitance 40.00nF 0.010nF ±(4% + 25 digits) 400.0nF 0.100nF ±(4% + 8 digits) 4.000μF 0.001μF 40.00μF 0.010μF 400.0μF 0.100μF 4.000mF 0.001mF ±(10% + 9 digits) Maximum Input: 600V AC RMS or 600V DC Temperature -40° to 1832°F 1°F ≤0°F ±(2.8% + 12 digits) >0°F ±(2.8% + 6 digits) -40° to 1000°C 1°C ±(2.8% + 6 digits) Frequency 10Hz to 1MHz 0.001Hz to 1kHz ±(0.1% + 5 digits) Duty Cycle 0.1% to 99.9% (≤100kHz) 0.01% ±1.5% (Range: 10% – 90%) Sensitivity: 250mV and < 20V RMS Maximum Input: 600V AC or 600V DC RMS ENGLISH CL310-1390115ART.indd 4 10/1/2015 3:43:25 PM

Dwg Name: CL310-1390115ART

Dwg No: 1390115 ECO No: 20550 Rev: D Pkg Dwg Ref: 1290186 Color Reference: N/A 5 ≤0°F ±(2.8% + 12 digits) >0°F ±(2.8% + 6 digits) (Range: 10% – 90%) WARNINGS To ensure safe operation and service of the meter, follow these instructions. Failure to observe these warnings can result in severe injury or death. • Before each use verify meter operation by measuring a known voltage or current. • Never use the meter on a circuit with voltages that exceed the category based rating of this meter. • Do not use the meter during electrical storms or in wet weather. • Do not use the meter or test leads if they appear to be damaged. • Use only with CAT III or CAT IV rated test leads. • Ensure meter leads are fully seated, and keep fingers away from the metal probe contacts when making measurements. • Do not open the meter to replace batteries while the probes are connected. • Use caution when working with voltages above 25V AC RMS or 60V DC. Such voltages pose a shock hazard. • To avoid false readings that can lead to electrical shock, replace batteries when a low battery indicator appears. • Do not attempt to measure resistance or continuity on a live circuit. • Always adhere to local and national safety codes. Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed. SYMBOLS ON METER AC (Alternating Current) AC/DC Voltage Resistance (in Ohms) Audible Continuity Double Insulated Class II Ground Warning or Caution Risk of Electrical Shock Diode Capacitance Hz Frequency % Duty-cycle V Voltage (Volts) A Amperage (Amps) °F/°C Temperature (Fahrenheit / Celsius) SYMBOLS ON LCD AC AC (Alternating Current) DC DC (Direct Current) Negative Reading Data Hold Auto Ranging MAX Maximum Value Hold MIN Minimum Value Hold Auto Power Off Low Battery Audible Continuity °F Degrees (Fahrenheit) °C Degrees (Celsius) M Mega (value x 106) k kilo (value x 103) m milli (value x 10-3) μ micro (value x 10-6) n nano (value x 10-9) V Volts A Amps Ohms Hz% Frequency/Duty Cycle CL310-1390115ART.indd 5 10/1/2015 3:43:25 PM