INSTRUCTIONS AND TEMPLATE BEFORE STARTING Attention Installer: • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire- related construction. • 120V may cause serious injury from electrical shock. Disconnect electrical pow ...
positioning tabs on the back of the cabinet should align with the 7/32” holes drilled earlier. Use four supplied screws to secure the cabinet to the duct. 6. Use level to make sure the cabinet is installed correctly. 7. Firmly insert the water supply tube back into the water nozzle on the top of the dist ...
date of purchase, the product will be free of defects in workmanship and/or material. As well the manufacturer offers a life time warranty on the flow through humidifier body. During the warranty period, we will replace or repair any defective part at no charge if the product is ret ...
5. The inlet filter should be fairly clean and free of debris. 6. Replace or clean the inlet filter if required. If it is punctured in anyway replace immediately. Remember the filter protects the orifice fitting and solenoid. 7. Position the cleaned or new filter in the solenoid valve inlet. Push ...
9. Replace the bypass tube on the humidifier’s side and secure with spring clamp. 10. Turn on the power to the humidifier, Turn on the water supply to the humidifier, Turn on your furnace. Run the humidifier and check for and repair any leaks. 6 Maintenance Figure 4. A B C Component Item Description Part List ...
3 23 * Specify brand 17 19 22 20 15 16 14 7 11 12 10 5 6 4 8 010937000 1/per inlet water filter #10-32 plastic screw brass compression nut nylon ferrule brass insert 1/per 3/per 2/per 2/per 019001067 010932000 010926001 01A930041 1/per 120/24VAC transformer grommet washer solenoid assembly side flow through 18 ...
PROBLEM: NOT ENOUGH HUMIDITY POSSIBLE CAUSE: Humidistat set too low. REMEDY: Turn up the humidistat. POSSIBLE CAUSE: Humidifier has only been installed for a few days. REMEDY: If you have just installed the humidifier it can take anywhere from 3 to 4 weeks to build up the humidity level in the home. POSSIBLE CAUSE: Not enough air flow ...
• Bypass tube and humidifier not installed parallel, use hard ducting – use hard ducting for any elbows – take the most direct route when ducting. • The bypass tube or humidifier is installed in front of air- conditioning coils or is blocked in some other way – move to another location and ensure m ...
• Ensure the bypass tube is fully stretched out tight. • Furnace filter is dirty and needs replacement. • Bypass tube and humidifier not installed parallel, use hard ducting – use hard ducting for any elbows – take the most direct route when ducting. • The bypass tube or humidifier is insta ...
Air King AK7000 user guide recommended for: 758.144150, 7000 EC, CTR-1, 32200, 6000.
⚠️ Download Safety
The Humidifier Installation, warranty, maintenance, troubleshooting manual (14 pages) is completely safe to download (last scan date: 13/04/2026).
Related PDF Instructions for Air King AK7000:
-
Air King AK80H Fan Operating manual, 8 pages
-
Air King D4S Fan Operating manual, 12 pages
-
Air King 5000 Humidifier Installation & operation manual, 12 pages
-
Air King Advantage Series ProHood Ventilation Hood Operating manual, 8 pages
-
Air King BFQF60 Air Conditioner Important instructions & operating manual, 12 pages
-
Air King ES130DG Fan Operating manual, 12 pages