AUMA SV 05.1 Operation Instructions Manual
Read Online
Read the AUMA SV 05.1 Operation Instructions Manual online using the built-in PDF viewer.
Key Pages of Document
SV 05.1 – SV 07.1 with actuator controls MEC 02.1 Marine version Operation instructions Assembly, operation, commissioning ...
with actuator controls MEC 02.1 marine version Operation instructions Scope of these instructions: These instructions are valid for globe valve actuators of the type range SV 05.1 – SV 07.1 with controls MEC 02.1 in marine version. Table of contents Page 1. Safety instructions 3 1.1. Range of application 3 1.2. Commissioning (electrical connection) 3 1.3. Maintenance 3 1.4. Warnings and notes 3 2. Short descrip ...
AUMA globe valve actuators are designed for the operation of valves in the shipbuilding industry. For other applications, please consult AUMA. The manufacturer is not liable for any possible damage resulting from use in other than the designated applications. Such risk lies entirely with the user. Observance of these operation instructions is considered as part of the designated use. 1.2. Commissioning (elec ...
with actuator controls MEC 02.1 marine version Operation instructions Features and functions Power supply Type of duty1) Short-time duty S2 - 15 min Motors Variable speed motor for 1-phase AC current Insulation class F, tropicalized Motor protection Power cut-off Speed control Actual value monitoring by hall sensors. PI speed control with defined load/speed range Self-locking Yes Limit switching ...
Operation instructions with actuator controls MEC 02.1 marine version Service conditions Enclosure protection according to EN 60529 Standard: IP 67 Option: IP 68 Corrosion protection SV: Sea water resistant housing made of bronze MEC: Housing made of sea water resistant aluminium, electro dip coated, black All external screws and shafts are of stainless steel Ambient temperature –25 °C to +70 °C Electromagnet ...
.Do not attach ropes or hooks to the handwheel/crank for the purpose of lifting by hoist. .If valve actuator is mounted on valve, attach ropes or hooks for the purpose of lifting by hoist to valve and not to valve actuator. .Store in a well-ventilated, dry room. .Protect against floor dampness by storage on a shelf or on a wooden pallet. .Cover to protect against dust and dirt. ...
Mounting is most easily done with the valve shaft pointing vertically upward. But mounting is also possible in any other position. The globe valve actuator leaves the factory in position CLOSED. .Prior to mounting, the globe valve actuator must be driven to the end stop CLOSED by turning the handwheel/crank clockwise. .Thoroughly degrease mounting faces of valve actuator and valve. .Place coupling sleeve on to valve shaft and secure (f ...
failure, the actuator may be operated manually. Different versions are avail- able as operation elements, refer to figures 2 to 5. Manual operation is activated by turning the handwheel/crank. A change-over is not required. The handwheel/crank does not rotate during motor operation. Turning the handwheel/crank during motor operation results in an extension or reduction ...
carried out by a skilled electrician himself or by specially instructed personnel under the control and supervision of such an electrician and in accordance with the applicable electrical engineering rules. AUMA globe valve actuators SV 05.1 – SV 07.1 are operated via the controls MEC 02.1. These are designed to be mounted separately on a wall. Suitable, flexible, and scree ...
four way crimp tool. Terminal cross sections: Mains/motor: max. 1.5 mm² Control cables: max. 1.5 mm² Plug socket connector XG2; XA2 Plug socket connector XG1; XA1 17 contacts (pole diagram, 5 contacts (refer to pole diagram, figure 7) figure 8) Plug socket connector XG4 Plug/socket connector XG3 17 contacts 5 contacts (pole diagram figure 7 inversed) (pole diagram figure 8 inversed) ...
.End position detection (refer to page 12) .Electronic position transmitter (option) (refer to page 15) .Mechanical position indicator (refer to 16) The switch compartment must be opened to perform the setting of these sub-assemblies. 9.1. Switch compartment: open Work on the electrical system or equipment must only be carried out by a skilled electrician himself ...
10.1. Clockwise closing: The following description is only valid for “clockwise closing”, i.e. driven shaft turns counterclockwise to close the valve. Identification within the terminal plan: AI M … for “clockwise” .Switch on the power supply. End position CLOSED .Move valve to end position CLOSED. The end position detection is correctly set if the yellow LED is illuminated and the output contacts (refer ...
.Move valve to end position OPEN. The end position detection is correctly set if the green LED is illuminated and the output contacts (refer to terminal plan) indicate “end position OPEN”. If this is not the case, correct the end position detection as follows: .Loosen screw (04) (figure 11) and pull off control disc (02), taking care of parallel key. .Figure 12: Loosen screw (05) at lower side of control disc. .Set indicator disc (03) ...
The direction of rotation of the indicator disc (figure 13) indicates the direc- tion of rotation of the output drive. .Move actuator manually to intermediate position or to sufficient distance from end position. .Switch on actuator in direction CLOSE and observe the direction of rota- tion. If the actuator is equipped with local controls (figure 15), the operation can be performed using the push buttons (OPE ...
The electronic position transmitter records the valve position and generates a current signal between 4 and 20 mA, using the position feedback measured by the potentiometer. After having mounted the globe valve actuator to the valve, check the setting as described below: .Connect voltage to electronic position transmitter. .Move valve to end position CLOSED. .Connect measuring device for 4 – 20 mA to ...
The mechanical position indication is realised using the white pointer below the indicator glass of the cover. The pointer setting shows the position CLOSED or OPEN with respect to the pipeline. With the cover removed, the symbols OPEN ( ) and CLOSED ( ) on the board show the electri- cally set end positions. .Move valve to end position CLOSED. .Sightly lift and turn pointer so that it points crosswise to the pipeline ...
14.1. Type of seating: set The MEC 02.1 is set in the factory in compliance with the order details. Later modifications are possible as described below. .Disconnect controls from the mains. For this, at least dis- connect plug XG1 from the controls. .Pay attention to the fact that the capacitors are charged with high voltages within the DC link. Even after having disconnected the supply voltage, haz- ardous high voltages are ...
connect plug XG1 from the controls. .When exchanging the fuses, only fuses with the same val- ues must be used. .Pay attention to the fact that the capacitors are charged with high voltages within the DC link. Even after having disconnected the supply voltage, hazardous high voltages are present at the DC voltage link during 1 minute. 18 Globe valve actuators SV 05.1 – SV 07.1 with ac ...
Precondition for reliable service is correct commissioning. Seals made of elastomers are subject to ageing and must therefore regu- larly be checked and, if necessary, be exchanged. It is also very important that the O-rings at the covers are placed correctly and cable glands fastened firmly to prevent ingress of dirt or water. We recommend additionally: .If rarely operated, perfor ...
20.1. Globe valve actuator SV 05.1 – SV 07.1 20 Globe valve actuators SV 05.1 – SV 07.1 with actuator controls MEC 02.1 marine version Operation instructions ...