Faber TIMRA Installation Manual

Text of the manual

1 < < < <

UK IRL Table of contents 1 Introduction ......................................................................................... 2 2 Safety and general information .................................................................. 3 3 Installation requirements ......................................................................... 4 3.1 Builders

> > > > 2

UK IRL 1 Introduction Note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user. This guide is concerning the following types of appliances: • TIMRA (for installation in a surround) • VISTA (for installation as a hole in the wall) Special features: • Realistic flame and

3 < < < <

UK IRL 2 Safety and general information Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and shall not be adjusted by the installer. The spillage monitoring system must not be put out of operation.

> > > > 4

UK IRL 3 Installation requirements Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. T

5< < < <

UK IRL 3.2 Dimensions Builders opening (mm) Timra Vista A Opening width 420 450 B Opening Height 565 590 C Opening Depth (min.) 370 370 Shelf dimensions (combustible) D Minimum height shelf from top frame 350 350 E Depth shelf 150 150 Dimensions (mm) F Box width 410 410 G Box Depth 318 318 H Box height 557 557 I Frame width 440 490 J Frame height 57

> > > > 6

UK IRL Flue requirements Suitable flues and flue sizes are as follows: • Flexible stainless-steel liner or pipe (to BS715). The flue connector outer collar is for connection to a 125 mm (5 inch) internal diameter pipe or liner. The inner collar is for connection to a 100 mm internal diameter pipe or liner • The flue must have a positive up drau

7< < < <

UK IRL 4 Instructions for installation 4.1 Gas connection 1 Installation pipes should be in accordance with IGE/UP/1B. Pipe work from the meter to the appliance must be of adequate size. 2 The complete installation including the meter must be tested for soundness and purged as described in the above code. 3 A means of isolation must be provide in th

> > > > 8

UK IRL 4.2 Preparing the appliance 1 Open the ashtray door and remove the two screws A 2 Lift and remove the glass frame. 3 Remove the trim by unscrewing the four screws B 4 Take the box with the log set out of the combustion chamber 5 Disconnect the TTB cable 6 Remove the burner chamber out of the firebox B B A A B B Fig.4.2 TTB connection Fig.4.3

9< < < <

UK IRL 4.3 Fitting the firebox • Position the firebox in the fireplace opening. • If the appliance is placed on a combustible floor then a fibrelux or similar heatproof board of 12 mm thickness should be placed under it. Any under floor vents or openings within the builders opening should be sealed off. • The surface of the floor must be suffi

Other Indoor Fireplace Manuals