Faber TIMRA Installation Manual
Text of the manual
1 < < < <
UK
IRL
Table of contents
1
Introduction ......................................................................................... 2
2
Safety and general information .................................................................. 3
3
Installation requirements ......................................................................... 4
3.1
Builders
> > > > 2
UK
IRL
1 Introduction
Note: these instructions should be read carefully and retained for future reference.
Please leave these instructions with the user.
This guide is concerning the following types of appliances:
•
TIMRA (for installation in a surround)
•
VISTA (for installation as a hole in the wall)
Special features:
•
Realistic flame and
3 < < < <
UK
IRL
2 Safety and general information
Before installation, ensure that the local distribution conditions (identification of the type
of gas and pressure) and the adjustment of the appliance are compatible.
This gas appliance is factory set and shall not be adjusted by the installer.
The spillage monitoring system must not be put out of operation.
> > > > 4
UK
IRL
3 Installation requirements
Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of
importance that you do not use the appliance shortly after a renovation of the home.
Because of the natural circulation of air, moist and volatile components from paint,
building materials, carpet etc. will be attracted. T
5< < < <
UK
IRL
3.2
Dimensions
Builders opening (mm)
Timra
Vista
A
Opening width
420
450
B
Opening Height
565
590
C
Opening Depth (min.)
370
370
Shelf dimensions (combustible)
D
Minimum height shelf from top frame
350
350
E
Depth shelf
150
150
Dimensions (mm)
F
Box width
410
410
G
Box Depth
318
318
H
Box height
557
557
I
Frame width
440
490
J
Frame height
57
> > > > 6
UK
IRL
Flue requirements
Suitable flues and flue sizes are as follows:
•
Flexible stainless-steel liner or pipe (to BS715). The flue connector outer collar is
for connection to a 125 mm (5 inch) internal diameter pipe or liner. The inner
collar is for connection to a 100 mm internal diameter pipe or liner
•
The flue must have a positive up drau
7< < < <
UK
IRL
4 Instructions for installation
4.1
Gas connection
1
Installation pipes should be in accordance with IGE/UP/1B. Pipe work from the meter
to the appliance must be of adequate size.
2
The complete installation including the meter must be tested for soundness and
purged as described in the above code.
3
A means of isolation must be provide in th
> > > > 8
UK
IRL
4.2
Preparing the appliance
1
Open the ashtray door and remove the two screws A
2
Lift and remove the glass frame.
3
Remove the trim by unscrewing the four screws B
4
Take the box with the log set out of the combustion chamber
5
Disconnect the TTB cable
6
Remove the burner chamber out of the firebox
B
B
A
A
B
B
Fig.4.2
TTB connection
Fig.4.3
9< < < <
UK
IRL
4.3
Fitting the firebox
•
Position the firebox in the fireplace opening.
•
If the appliance is placed on a combustible floor then a fibrelux or similar heatproof
board of 12 mm thickness should be placed under it.
Any under floor vents or openings within the builders opening should be sealed off.
•
The surface of the floor must be suffi