Alphatech NUDV-00 Installation & Operating Manual
Read Online
Read the Alphatech NUDV-00 Installation & Operating Manual online using the built-in PDF viewer.
Text of the manual
New All-Purpose Door Guard
NUDV - 00
NUDV - 01
NUDV - 02
NC - mod4
NM - mod4
NKLA
Installation and Operating Instructions
We congratulate you on purchase of “New All-Purpose Door Guard”
(NADG = NUDV), which is the improved version of successful “All-Purpose
Door Guard” (ADG = UDV). This all-purpose guard will widely manage to
satisfy your needs of communication with persons at the building front door or
your company entry, or family house doorway. The universality lies in
possibility to connect this guard to an internal line of your branch exchange
regardless to type and producer of this exchange (analog line). Up to two 16-
digit numbers, including “ * ”, “ # ”, Pause and Flash in tone dialing, can be
programmed to each button.
The basic guard module is supplied either without button, or with one or
two buttons. Further the whole system allows to be enlarged by NC-mod4 and
NM-mod4 modules up to 64 buttons using the basic mechanical MK1...MK4
units. The whole assembly can be completed with cover frame or rain-
protective canopy both under plaster, and on plaster.
The guard is supplied from branch exchange line – his features remind a
loud telephone. The basic features include the possibility to open up to two
doors by means of connected electrical locks (the first 10 buttons can be used
for door code opening) and easier programming by either through serial line (or
USB) from PC, or using the telephone with tone dialing in two ways, either by
communication with guard after entering 4-digit service password, or
connecting the programming stretcher on guard basic board. Having been
forgot the service password it is possible to use the second way.
Manual version V8,1 27-1-2009
Alphatech spol. s r.o.
Jeremenkova 88
140 00 Praha 4
Tel/fax: 272103334
www.alphatech.cz / [email protected]
Table of Contents
1
BASIC DESCRIPTION ...................................................................................6
1.1
FEATURES ..................................................................................................6
1.2
MODULE ASSEMBLY...................................................................................7
1.3
MODULE FEATURES....................................................................................8
1.3.1
NUDV Basic Module .............................................................................8
1.3.2
Extending Module with NC-mod4, NM-mod4 Buttons...........................11
1.3.3
NKLA Keyboard Module......................................................................12
1.3.4
Other modules .....................................................................................12
1.4
INSTALLATION OF GUARD ASSEMBLY .......................................................12
1.4.1
Installation on Plaster..........................................................................12
1.4.2
Flush-Mounted Installation..................................................................12
1.5
CHANGE OF NAMEPLATES .........................................................................13
2
ALL-PURPOSE GUARD OPERATION.......................................................14
2.1
SIGNALING OVERVIEW .............................................................................14
2.2
VISITOR AT DOOR.....................................................................................14
2.2.1
Guard without Keyboard......................................................................14
2.2.2
Guard with Keyboard ..........................................................................15
2.3
PERSON INSIDE OBJECT ............................................................................16
2.3.1
Outgoing Call......................................................................................16
2.3.2
Incoming Call......................................................................................16
3
PROGRAMMING OF PARAMETERS........................................................17
3.1
PROGRAMMING THROUGH PHONE .............................................................17
3.1.1
Entry to Programming.........................................................................17
3.1.2
Programming of parameters ................................................................17
3.2
PROGRAMMING FROM PC – PROGRAM NSET..............................................18
4
DESCRIPTION OF PARAMETERS............................................................19
4.1
DIRECT DIALING – MEMORIES ..................................................................19
4.2
SWITCHES ................................................................................................19
4.3
BASIC PARAMETERS .................................................................................21
4.4
TIME PARAMETERS...................................................................................23
4.5
PRESETTING AND DELETING......................................................................26
4.6
PROGRAMMING TERMINATION..................................................................26
4.7
SYSTEM SETTING......................................................................................27
4.8
OVERVIEW OF PARAMETERS .....................................................................28
4.9
LIST OF PRESETTING PARAMETERS............................................................30
NUDV – Installation and Operating Instructions
5
5
TECHNICAL PARAMETERS......................................................................31
5.1
ELECTRICAL PARAMETERS........................................................................31
5.2
MECHANICAL DIMENSIONS........................................................................31
6
TABLE FOR EASY PROGRAMMING........................................................32
7
DECT – DISTYBOX......................................................................................35
7.1
DISTYBOX DESCRIPTION ..........................................................................35
7.2
DISTYBOX SIGNALING..............................................................................35
7.3
DISTYBOX PROGRAMMING .......................................................................36
7.4
LOG ON TO BASE STATION........................................................................36
NUDV – Installation and Operating Instructions
6
1 Basic Description
1.1 Features
� Modular system allows to connect 1 to 64 buttons
� Voice communication is supplied only from telephone line
� Impulse and tone dialing (DTMF)
� Two 16digit numbers with each button (including *, #, Flash and
Pause)
� Day/night switching
� Possibility of the call extension by * or # choice
� Possible to connect two independent locks for door opening
� Possible use of 5 switch modes (e.g. camera, lighting, gradual
opening)
� Two codes for hanging up the guard from telephone
� Two codes for door opening from telephone
� Six code locks (password from buttons at the door)
� Possibility to connect a numerical keyboard this way that the guard
can include 0 – 18 standard buttons
� Keyboard mode could be either direct dialing or dialing from memory
� Optional number of rings before taking an incoming call
� Optional time among button pressing by code entry
� Optional time of hanging up when the choice is repeated
� Optional time before choice start
� Optional parameters of tone choice, length of Flash and Pause
� Company setting in some levels
� Possible programming not only by remote control, but also by direct
route to PC
� Integrated heating of printed circuit
� Permanent lighting through visiting cards
� Earthing outlet pro better protection against static electricity
NUDV – Installation and Operating Instructions
7
1.2 Module Assembly
The NUDV structural elements are the basic modules with two, one or no
buttons and extending button modules NC-mod4 and NM-mod4 with four
buttons. Further it is possible to provide the assembly with numerical keyboard
and camera module. The complete assembly consists similarly to UDV system
of max. 4 modules in column and max. 3 columns side by side.
NUDV2
NUDV1
NUDV0
NC(M)-mod4
Camera IP
Fixing
KPD2 – rain -
Canopy2
Flanging frame2
frame 2
protective cover
(flush -mounted)
(flush -mounted)
(on plaster)
By flush-mounted assembly the MK-1 to MK-4 boxes are used as well as with
UDV system.
MK-2 Analog.camera NKLA keyboard module DECT - DistyBox
Examples of frame configuration
NUDV – Installation and Operating Instructions
8
1.3 Module Features
1.3.1 NUDV Basic Module
The NUDV basic module is supplied in three variants – with two NUDV2
buttons, one NUDV1 button and without buttons, type NUDV0.
V1.x
Fig. 1 Rear view of basic module
Fig. 2 Rear view of setting parts in version V6.x
NUDV – Installation and Operating Instructions
9
To ensure the basic function the telephone line can be connected – the
terminal marked as "a b LINE". It is connected in the same way as any
telephone to any branch exchange. The guard’s circuits are supplied from
telephone line, so that nothing should be connected for voice communication.
If one or two switches are necessary to be used, the A.C. voltage of min.
10Vst - max. 15Vst or D.C. voltage of min. 12Vss to max. 18Vss must be
energized to "12V" terminal. This source loading depends on number of
modules, since it simultaneously serves feeding of lighting through visiting
cards – at max. number of connected modules the demand will not exceed
300mA. This source can be also used for feeding of lock(s), and then it is
necessary to consider the electrical lock demand. In practice the alternating
feeder 12V/1A mostly meets these demands.
The connection of switch contact terminals is shown on fig. 1. The "NO"
designation means an idle-disconnected contact, "COM" means a pin contact
(middle) and "NC" means an idle-connected contact. The contacts of both
switches are galvanically isolated each other and from other guard circuits. The
variants of connection are shown on fig. 3.
Fig. 3 Examples of switch connections
NUDV – Installation and Operating Instructions
10
The "G" Faston 2.8mm terminal protects against static electricity – to be
connected to earthing.
The "HEAT" jumper serves the switching of board heating. This function
requires the connection of 12V supply on "12V" marked terminal.
The "EXPANSION" marked connector serves the connection of extending
modules by means of flat cable.
The "PRG" marked connector provides the guard adjustment from PC by
means of serial cable (KAB) and serves to the service for diagnostics and new
software load.
The "SERVICE" jumper serves to direct access to programming. It can be
used, for example by absence of password for programming.
Setting voice communication – position trimmers are presetting from
manufacture and in majority case agree with, therefore changes setting altering
only in necessary case.
For older version of board V1.x (fig.1) :
The "VOLUME" trimmer serves to the adjustment of loudspeaker
volume, it has no effect to other guard features. The "MIC" trimmer (placed
under PDV board) provides the adjustment of microphone volume. Such
adjustment can improve the feature of speech way, e.g. by ambient noise in the
street. At setting of a great gain of trimmer „MIC" is able to happen, that sound
from speaker doorphone is interrupting, next is necessity gain of trimmer „MIC"
make smaller.
Procedure of setting: trimmer SPK setting to maximum (turn to the right),
trimmer MIC on minimum and at conversation connection subscriber speaking
(in building) permanent talk, trimmer MIC turning (to the right), until sound from
speaker begins interrupt, next gain teeny reducing (moving round a slight
amount left). It shall everything be all right.
For newer version board V6.x (fig.2) :
Trimmer "MIC" be instrumental to setting loudness of microphone,
trimmer "SPK" be instrumental to setting loudness loudspeaker. In this version
is big reserve in gain, therefore isn't recommended adjust more than on half,
typical is in 1/3 from minimum gain. Trimmer "TRH" be instrumental to setting
levels activation of microphone, it means, so as doorphone "non whoop" owing
to acoustic loop so selection, which direction has priority, whether from
microphone, or into loudspeaker. Level from which volume with "switch on"
direction from microphone doorphone setting trimmer „TRH". This setting
interact level surrounding noise and setting gain of microphone „MIC".
Progress of setting: trimmer MIC and SPK setting in 1/4 from minimum
loudness (minimum is sense turning left), trimmer TRH setting in central
position. At conversation connection stilly talk and trimmer TRH turning from
central value direction to the left so, till you will on the side phone (in building)
hear. Gain of loudspeaker, in some case of microphone set-up according to
needs.
NUDV – Installation and Operating Instructions
11
1.3.2 Extending Module with NC-mod4, NM-mod4 Buttons
This module is supplied in two designs. The NC-mod4 module has four
buttons and includes the electronics to be connected to the basic module or to
previous NC-mod4 module. This module is only connected by flat cable –
buttons and lighting through is already interconnected. The terminals for
connection of other four buttons and current supply of lighting are further
placed on module (on following NM-mod4). The NM-mod4 module is always
connected to previous (in row starting with basic module) NC-mod4. The
connection is not prepared and should be done by conductors – see on figure
4. The flat cable connection is
facilitated by connector locks,
preventing from rotation, but
to keep the connection routing
is imperative.
“To NUDV” is always the
routing to the basic module.
“To Cmod” is routing to the
row end (on last NC-mod.).
Fig. 4 Connection of NC-mod and NM-mod and
connection of modules
NUDV – Installation and Operating Instructions
12
1.3.3 NKLA Keyboard Module
The keyboard module is only connected by flat cable as well as NC-
mod4 module. The only difference is that keyboard module is always the last in
row (no other module can be connected behind it) and it can be only linked to
the first (directly to the basic module), the second (to output of the first NC-
mod4) or the third (to output of the second NC-mod4) positions. It means that 0
to 18 buttons with direct dialing can be used instead of keyboard (per
assembly). The most frequent used assemblies are:
–
NUDV2 + NKLA
–
NUDV2 + NC-mod4 + NKLA
–
NUDV2 + NC-mod4 + NM-mod4 + NKLA
–
NUDV2 + NC-mod4 + NM-mod4 + NC-mod4 + NKLA
–
NUDV2 + NC-mod4 + NM-mod4 + NC-mod4 + NM-mod4 + NKLA
Pay attention when programming – the position of keyboard connected must be
correctly specified (parameter 48).
The
choice
is
entered
by
gradual pressing of buttons with digits.
Firstly the key symbol must be
pressed to enter a password. When
pressing X, the guard will hang up.
Rem: From version of firmware 7.8
makes it possible dial DTMF dialing during talk from
keyboard.
1.3.4 Other modules
Other modules extending the guard assembly are actually offered on
www.alphatech.cz
and
can
be
ordered
by
phone
or
fax
on
number: +420272103334.
1.4 Installation of Guard Assembly
1.4.1 Installation on Plaster
By installation on plaster the only compact box -
Rain-Protective Cover KPDxx is used, which will
supersede all mechanical parts (MKxx, Canopy
xx and Fixing Frame xx). The installation is made
by screwing to the wall by means of dowels. See
KPD1 on figure.
1.4.2 Flush-Mounted Installation
The MKxx mounting box is built-in
wall.
Be
careful
in
orientation
of
assembling holes when nearly MK1
square box is used – it must be in vertical axis.
The well-embedded box is shown on figure.
NUDV – Installation and Operating Instructions
13
The Protecting Frame (provides overlapping of unevenness after
mounting box walling-in) and Canopy (necessary for installation in external
areas) form other accessories for flush-mounted installation. When installed in
surroundings with possible water condensation (temperature changes) or water
spraying (rain) it is recommended to connect the jumper on basic module –
heating ON.
The board heating has two positive functions partly it heats up the
electronics in winter at temperatures below –20°C (most details with extended
temperature range has guaranteed parameters from –20°C) and partly with
external installation at swift temperature changes and higher air humidity by
switched heating no water condensation occurs on basic guard board, which
assures its reliable function.
1.5 Change of nameplates
The first step is dismantling of
a fixing frame from module, where
we want to change a nameplate. It
can be executed by unscrewing of
two screws under plastic covers on
fixing frame. When removing the
fixing
frame
we
can
see
two
independent modules. The front part
(metallic) of the button module has to be first separated from plastic part in this
way that we will put off the plastic lug, ensuring the front part on the right side.
Each button has its separate nameplate hold by means of plastic flag (see
figure). The paper nameplates can be printed from Excel form (to be
downloaded on www.alphatech.cz) or from Nset setting program.
NUDV – Installation and Operating Instructions
14
2 All-Purpose Guard Operation
2.1 Signaling Overview
The all-purpose guard signals an acoustic conditions they may occur
during operation. Another signaling can be done by means of red LED (placed
under microphone hole). You can listen the signaling samples in Nset setting
program.
Condition
Tones
Tone frequency
LED
Line lifting up
–▄–■–▀–
425-850-1275
glows
Line hanging up
–▀–■–▄
1275-850-425
goes
out
Report after calling
–▄–■–▀–
425-850-1275
glows
Command confirmation from
phone
––█––
425
Dialing
DTMF/Pulse
goes
out
Call
glows
Notice about call end
–■–■–■–
1275
glows
Entry to programming from phone
–■–■–■–
850
glows
Programming from phone
––▓–▓–––––
mod. 850
glows
Parameter confirmation
––█––
glows
Entry to programming from PC
–■–■–■–
850
glows
Programming from PC
blinks
Connection to line (Reset)
–■–▄–■–
1275-850-1275
blinks
Error (anything, if unsuitable)
–■–■–■–■–■–■–
425….
Empty memory (no progr. numb.)
–█–▄–■–▄–■–▄–
850-1275-1700…
2.2 Visitor at Door
The all-purpose guard function is influenced partly by used guard
assembly (with keyboard or without it) and partly by setting of guard
parameters (see chapter “Parameter Overview”).
2.2.1 Guard without Keyboard
The guard buttons are provided by nameplates or positions of persons
inside the object. The incoming person will press the corresponding button, the
guard will lift up the line neither immediately (the button is not the first number
NUDV – Installation and Operating Instructions
15
from code lock), or with delay (parameter 53) and after period given by
parameter 55 will dial the programmed phone number. The dialing number
differs by choice mode, which is set in the guard (parameter 47):
- Day/night mode = being the guard in Day mode, so it is always dialing
a number set in parameter 1, in Night mode, it is always dialing a
number set in parameter 2. The mode switchover is set in parameters
45,46.
- mode of second number group = first press – it always dials a number
set in parameter 1. By repeated press of the same button or detection
of busy tone after dialing the guard will select the number from the
second group (parameter 2). The next press of the same button again
selects a number of the first group, etc..……
If a visitor presses the button after guard lifting up, so the guard will hang
up for a period given by parameter 54, lift up the line and dial a new number.
The number choice is carried out both tone (DTMF), and pulse dialing
according to parameter 41 setting.
The switch (code lock) can be controlled by first 10 buttons of guard. If
the visitor at door presses buttons in such combination that meet the
preprogrammed code (parameters 32-34) and the time among presses is not
bigger than the set point (parameter 53), then the guard will lift up and close
the corresponding switch (if set in m=1 or m=5 modes) to the period given by
parameter 36 event. 38. Then it will hang up.
2.2.2 Guard with Keyboard
The guard with keyboard can also include
besides the keyboard up to 18 buttons of direct
dialing always behaving as to be mentioned in
Chapter 2.2.1 except the code lock. This one is
always situated on keyboard. After keyboard is
connected, the position, where the keyboard is
connected to, should be set (parameter 48).
The keyboard has two functional buttons –
key symbol = once pressing the numerical
combination is considered as the combination for control of the switches. The
second button –X symbol = when pressing the guard immediately will hang up.
The number selection on keyboard can be executed in two ways
(parameter 49):
-
The incoming person is dialing number as to be done on phone – the
period among button presses should be lower than the value given by
parameter 53. After this period the guard will lift up and dial the given
number.
-
On buttons the incoming person is dialing a two-digit number (from 01
to 64), which represents the memory number, where the 16-digit
number is stored (same as for buttons). The number dialing is
NUDV – Installation and Operating Instructions
16
managed by Day/Night setting or mode for two groups of numbers (as
described in Chapter 2.2.1).
-
Version of firmware 7.8 makes it possible dial DTMF dialing during talk
from keyboard. This feature it is possible switch on only by
programming from phone, from PC program this feature isn't
accessible and after programming door phone possibility dial from
keyboard during talk is OFF. Parameter 40d - d=0 switch off (default),
d=1-3 switch on dialling during talk,1= buton key dial *, 2=button key
dial # and 3=button key dial “A”.
2.3 Person Inside Object
The person inside object is considered a person that is in phone contact
with all-purpose guard.
2.3.1 Outgoing Call
The outgoing call is the call from guard (caused by visitor). After guard
choice the telephone is ringing inside object and the lifting up will allow
speaking to the visitor at door. The code choice can close the switch
(parameter 35), if set to m=1 or m=5 modes, change over the Day/Night modes
(parameters 45,46) and hang up (parameter 43). The guard in 10 seconds
before call end (parameter 52) will send a notice about call end and the call
may be extended by sign selection (parameter 42). The telephone hanging up
will end the call (the exchange is sending a busy tone on guard’s line and the
guard also will hang up).
2.3.2 Incoming Call
The incoming call is the call from guard (caused by person inside object). After
exchange number selection, where the guard is connected, the guard’s line is
ringing and when set number of rings is over (parameter 51), the guard will lift
up and it is possible to speak. The possibilities are the same as with outgoing
call (Chapter 2.3.1).
•
Except the first 10 seconds, where extra "# and service password"
(parameter 44) can be entered, the guard then will proceed with
programming mode.
•
The other exception of incoming call is by connected “SERVICE” jumper.
The guard after line lifting up proceeds then with programming mode
(without service password).
NUDV – Installation and Operating Instructions
17
3 Programming of Parameters
3.1 Programming through Phone
3.1.1 Entry to Programming
The all-purpose door guard will be set to programming mode in two ways:
1. by password – only incoming call! – answer the telephone and dial a
number, where the guard is lined (either branch number, if connected to
branch exchange or number of state line to object, where the guard is placed
and let you put through to branch directly connected with guard). The guard
will answer (you hear tone for answering – see Chapter 2.1 page 14)
up to 10 sec dial #xxxx, where xxxx is the service number for entry to
programming and if O.K., the registration tone to programming will
sound and afterwards the programming tone is heard (see Chapter 14
page 14). In basic setting is xxxx = 0000.
2. by "SERVICE" jumper – only incoming call! – you will realize the
connection with guard in the same way as in art. 1, but when the
SERVICE jumper is connected, then the guard after answering directly
comes to programming mode – you hear tone for answering,
registration tone to programming and afterwards the programming tone
is heard. (see Chapter 2.1 page 14).
3.1.2 Programming of parameters
The initial state for programming is signaled by programming tone and
the guard will come back to this state always after time expiration (5 seconds)
even you started to program anything.
When programming two types of parameters will occur. Partly they are
parameters with fixed length – the majority of them they are, then the
programming is affirmed and the parameter is always recorded immediately
after mandatory length fulfillment by acknowledge tone and partly the
parameters with variable length (parameter 1,2,32,33,34), followed with
confirmation and the recording of the parameter after inactivity period expires
(5 sec). The only case with immediate recording of parameters is the fulfillment
of max. number of recorded signs (numbers) – by parameters 1 and 2 it is 16,
by parameters 32,33,34 it is 6.
If during programming you enter number (sign) not allowable by its extent
then the guard immediately emits an error tone, the parameter will not be
recorded nor changed, the guard will come to initial state and it is possible to
repeat the parameter setting or program another parameter.
The guard stays inactive in programming mode for 34 seconds, then he
will automatically hang up. By every dialing of DTMF tone this period is set up
repeatedly. The selection of parameter 9 can also end the programming mode.
Note 1. if you wish to keep the connection (extend the 34 seconds period) than the
customer will think over the other setting, so pressing e.g.. 7, 0, * or # form time to time
NUDV – Installation and Operating Instructions
18
will be sufficient and the guard immediately responds by error tone, but he will extend
the period to hanging up..
Note 2. The # sign is not used by entering of 32,33,34 parameters can be used for
immediate parameter entering.
3.2 Programming from PC – Program Nset
To guard’s setup by means of personal computer (PC) the special KAB cable
to serial port and Nset program should be available and the guard has to be
connected to telephone line.
Procedure:
-
Connect the NUDV to the line
-
Line the guard with PC by KAB cable (if PC serial port absent, the USB-
COM reduction is to be used). The guard will answer and LED light on the
front panel will light.
-
Run the Nset program – the guard will report the his conversion to PC
programming mode (viz. chapter 2.1 page 14). After Nset program being
run the guard is in this mode – this status is indicated by LED light on front
panel by 1 second flashing. By loss of connection it is necessary to
disconnect the cable from guard and connect it again – the guar will
answer and if Nset program runs he will report his conversion to
programming mode.
For details of setup refer to program help and on producer’s pages
www.alphatech.cz.
NUDV – Installation and Operating Instructions
19
4 Description of Parameters
4.1 Direct Dialing – Memories
Parameter Value
Meaning
Basic
1
tt nn… No. nn under button tt
-
tt – Button number (memory), always set in two-digit manner [01-64]
nn – telephone number up to 16 digits, we want to store. To
store other choice flags the assignment given in table is
used.
The numbers stored in parameter 1 are the number of the
first group or numbers of Day mode.
Neither basic setting do not change or delete the stored
numbers.
Parameter Value
Meaning
Basic
2
tt nn… No. nn under button tt
-
tt – Button number (memory), always set in two-digit manner [01-64]
nn – telephone number up to 16 digits, we want to store.
To store other choice flags the assignment given in
table is used..
The numbers stored in parameter 2 are the number of the
second group or numbers of Night mode.
Neither basic setting do not change or delete the stored
numbers.
Note: The switchover to Day/Night mode remains set in guard
even after line disconnection.
List of related parameters: 41 45 46 47 48 49 57 58 59 50 81 82
4.2 Switches
Parameter Value
Meaning
Basic
31
r m
switch r works in m mode
11 21
r
– switch number [1-2]
m – switch mode [for r=1 1-4 , for r=2 1-5]
m=1 switch mode – it will close on command or password for ss period (used
for electrical locks, gate opening etc.)
m=2 camera mode – it will close by guard lifting up and open by hanging up.
mean. choice
0 - 9
0 - 9
#
#
*
* *
Flash
* #
Pause
* 0
mean.
choice
0 - 9
0 - 9
#
#
*
* *
Flash
* #
Pause
* 0
NUDV – Installation and Operating Instructions
20
m=3 lighting mode – it will close by guard lifting up and stay closed even for
ss period after guard hanging up (the line is engaged for this period).
m=4 switch mode – it will close after button pressing and open after ss period
(used for e.g. external bell or horn connections).
m=5 gradual opening mode – in this mode the only switch 2 will be set
together with switch 1 set to mode 1. The switch 1 is activated for ss
period, then the time xx is proceeding before switch 2 closing. Then the
switch 2 is activated for ss period and afterwards the guard hangs up.
Note: The only switch 1 can be activated from phone and all sequence started.
Besides that the switch 2 can be separately activated from buttons by password.
List of related parameters: 32 33 34 35 36 37 38 8# 83
Parameter Value
Meaning
Basic
32
r hhhhhh passw. hhhhhh for switch r in DAY +
NIGHT mode
-
33
r hhhhhh passw. hhhhhh for switch r in DAY mode
-
34
r hhhhhh passw. hhhhhh for switch r in NIGHT mode
-
r
– switch number [1-2]
hhhhhh – password for switch closing from buttons or keyboard [2 to 6 digits]
Total 6 passwords, they are controlled by Day/Night; the combination is
entered either by guard buttons (first 10 buttons) or from attached keyboard
(after pressing of key symbol). The switch closing influences the set switch
mode and Day/Night switchover. By setting of choice mode of 2 number
groups the guard is permanently in DAY mode.
By password choice some rules have to be observed:
§
Select passwords in way not to find its combination out from wear of
certain buttons by frequent use.
§
Select the first password button from frequentless button for direct
dialing (-extends choice time)(-not valid for keyboard).
§
Pay attention to congruity of password numbers when one password
includes other one, e.g. switch 1 has 1234 and switch 2 has 12345.
Then after pressing button 4 the only switch 1 is called, but password
choice 234 for switch 2 can call both switches after pressing switch 4.
Note: The switchover to Day/Night mode remains set in guard even after line
disconnection.
List of related parameters: 31 35 36 37 38 45 46 47 48 49 53 8# 83
Parameter Value Meaning
Basic
35
r aa
command aa from phone after r switch closing
155 266
r
– switch number [1-2]
aa – command from phone after switch closing [2 digits]
NUDV – Installation and Operating Instructions
21
The same command can be set for both switches, then they are activated at
the same time. The advantage is to set the same command both for switch
closing and command to guard hanging up (parameter 43) aa=bb.
List of related parameters: 31 36 37 38 43 8# 83
Parameter Value
Meaning
Basic
36
r ss
ss period [sec] of r switch closing
105 205
r
– switch number [1-2]
ss – duration of switch closing [2 digits 01-99]
List of related parameters: 31 32 33 34 35 37 38 8# 83
Parameter Value
Meaning
Basic
37
r p
r switch control by incoming call
11 21
r – switch number [1-2]
p – parameter, if p=1 allowed or p=0 prohibited to control the switch during
incoming call.
To prohibit the control during incoming call is important e.g. when using switch
2 in mode 1 for control of garage gate opening, when the electronics opens the
gate and the gate is closed by car passage. Then the control from phone could
undesirably cause the permanent gate opening (not closed – no car passage).
List of related parameters: 31 35 8# 83
Parameter Value
Meaning
Basic
38
xx
xx period [sec] between switches 1 and 2
closing
10
xx – time between close switches 1 and 2 by m=5 mode setting (gradual
opening) [2 digits 01-99]
List of related parameters: 31 32 33 34 35 36 37 8# 83
4.3 Basic Parameters
Parameter Value
Meaning
Basic
41
v
choice type v – tone / pulse
0
v – choice type v=0 is DTMF tone choice, v=1 is pulse choice
List of related parameters: 1 2 8# 84
NUDV – Installation and Operating Instructions
22
Parameter Value
Meaning
Basic
42
z
sign for call extension
*
z – sign for call extension * or # (10sec before call end the guard will send a
notice, then the call may be extended)
List of related parameters: 52 8# 84
Parameter Value
Meaning
Basic
43
g bb
command for guard hanging up from phone
155 266
g – command order [1-2] (two commands in order to hang up the guard using
both switches)
bb – command for guard hanging up from phone [2 digits]
The advantage is to set the same command both for switch closing (parameter
35) and command to guard hanging up aa=bb.
List of related parameters: 35 8# 84
Parameter Value
Meaning
Basic
44
xxxx
service password
0000
xxxx – service password for entry to programming
List of related parameters: 8# 84
Parameter Value Meaning
Basic
45
dd
command for DAY switching
11
46
nn
command for NIGHT switching
10
dd – command for DAY mode switching [2 digits]
nn – command for NIGHT mode switching [2 digits]
Note: The switchover to Day/Night mode remains set in guard even after line
disconnection.
List of related parameters: 1 2 33 34 47 8# 84
Parameter Value
Meaning
Basic
47
e
mode of guard choice
1
e – mode of guard choice e=0 selects numbers of the first and second
groups, e=1 selects number per Day/Night guard mode.
List of related parameters: 1 2 8# 84
ATTENTION !! This parameter setting will sharply influence the dialing.
NUDV – Installation and Operating Instructions
23
Parameter Value
Meaning
Basic
48
c
keyboard connection
0
c – c=0 only NC-mode connected to the basic module
c=1 the keyboard connected on the first position
c=2 the keyboard connected on the second position
c=3 the keyboard connected on the third position
ATTENTION !! This parameter setting will sharply influence whole guard
function.
List of related parameters: 1 2 32 33 34 47 49 53 8# 84
Parameter Value
Meaning
Basic
49
o
keyboard mode
0
o – o=0 dialing as on normal telephone (all number of called person should
be pressed on keyboard).
o=1 Only 2-digit memory number is entered on keyboard by which the
number of called person is stored (memory number corresponds to button
number with respect to Day/Night switchover).
ATTENTION !! This parameter setting will sharply influence keyboard function.
List of related parameters: 1 2 47 48 53 8# 84
This parameter is avalaible only in version firmware 7.8
Parameter Value
Meaning
Basic
40
d
dialing DTMF from keyboard during talk
0
d – d=0 dialing DTMF from keyboard during talk is disabled
d=1 dialing DTMF from keyboard during talk is enabled and key=*
d=2 dialing DTMF from keyboard during talk is enabled and key=#
d=3 dialing DTMF from keyboard during talk is enabled and key=A
4.4 Time Parameters
Parameter Value
Meaning
Basic
51
q
number of rings before guard call lifting up
2
q – Number of incoming call rings, the guard lifts up among rings namely 2
sec. after detection q – times rings. The number can be set from 1 to 9.
List of related parameters: 44 8# 85
NUDV – Installation and Operating Instructions
24
Parameter Value
Meaning
Basic
52
d
max. call time
2
d – max. time, for which the guard is hanging up, this
time can be extended during call by sign choice from
telephone (* or #). Time setting is per table.
List of related parameters: 42 8# 85
Parameter Value
Meaning
Basic
53
w
time among button presses
2
w – max. time [sec] among button presses [range 1-9]
§
normal buttons
-
switch closing – if time between two next presses is bigger than w
time, the code is not evaluated correctly.
-
dialing – if the button, we are pressing, is the first password number
for switch closing, so the choice is delayed by this w time.
§
keyboard
-
switch closing – if time between two next presses is bigger than w
time, the code is not evaluated correctly.
-
dialing
-
dialing the same as of phone, if time after the last pressed button
is bigger than w time, then the dialing starts. If the number is
incomplete, it is necessary to hang up (X button) and the dialing
will be repeated.
-
dialing from memory, if time following the first pressed button is
longer than w time, then the entry of memory number has to be
repeated.
List of related parameters: 1 2 32 33 34 47 48 49 8# 85
Parameter Value
Meaning
Basic
54
z
time of hanging up when dialing repeated
2
z – time [sec] for which the guard will hang up, before repeated dialing
(button pressing during call or dialing, busy tone detection) [range 1-5]
List of related parameters: 8# 85
time
[min]
choice
0,5
0
1 - 9
1 - 9
15
*
30
#
NUDV – Installation and Operating Instructions
25
Parameter Value
Meaning
Basic
55
z
time before dialing
1
z – time [sec] after guard lifting up before dialing [range 1-5]. This time is
different for each exchange, but most central exchanges usually manage
to process dialing up to 2 seconds after line lifting up.
List of related parameters: 8# 85
Parameter Value
Meaning
Basic
56
hh
number of rings before hanging up
12
h – after finishing the dialing it calculates number of KVT (ringing tones). If
the number exceeds h value, it will hang up [range 04-99]. The dialing is
repeated in case, when the dialing mode of 2 groups is set.
List of related parameters: 47 8# 85
Parameter Value
Meaning
Basic
57
t
DTMF tone duration (tone) choice
5 (100ms)
58
m
gap duration among DTMF tones
5 (100ms)
59
f
Flash duration
1 (100ms)
50
p
pause duration / interdigit gap
8 (800ms)
t
– DTMF tone duration is determined per formula:
(entered number + 5) x 10 = tone duration [ms]
[range 1-0 i.e. 60-150ms]
m – gap duration among DTMF tones is determined per formula:
(entered number + 5) x 10 = gap duration [ms]
[range 1-0 i.e. 60-150ms]
f
– Flash duration is determined per formula:
entered number x 100 = Flash duration [ms]
[range 1-6 i.e. 100-600ms]
p – pause duration is determined per formula:
entered number x 100 = pause duration [ms]
[range 5-0 i.e. 500-1000ms]
– p time is simultaneously the duration of interdigit gap at pulse dialing.
List of related parameters: 1 2 41 8# 85
NUDV – Installation and Operating Instructions
26
4.5 Presetting and Deleting
Parameter Value
Meaning
Basic
8#
#
basic setting
executes
This setting does not influence 1 and 2 (numbers stored in memory)
Parameter Value
Meaning
Basic
81
deletes all numbers in
group 1 (Day mode)
82
deletes all numbers in
group 2 (Night mode)
83
basic setting only
for parameters 3x
only 3..
84
basic setting only
for parameters 4x
only 4..
85
basic setting only
for parameters 5x
only 5..
The parameters 81 and 82 will execute deleting of all numbers stored in
memories for buttons.
The parameters 83 – 85 will execute a selective basic setting only for
parameters starting with 3.. – 5..
ATTENTION !!! the deleting is non-reversible !!!, It is then necessary to
program it again.
4.6 Programming Termination
Parameter Value
Meaning
Basic
9
E N D of programming
After dialing 9 to programming tone the guard will hang up.
NUDV – Installation and Operating Instructions
27
4.7 System Setting
Parameter Value
Meaning
Basic
6#
s
number of non-fitted buttons of basic module
The basic module is fitted with 2 buttons as standard, i.e. s = 0, s = 1 is set up
for basic module with one button and s = 2 for module without buttons. This
setting is a factory one, no service can change it and so it is recommended not
to change this parameter.
Note: Connecting. to the line the value of this parameter is checked and if not
satisfactory form unknown reasons, so it is set up to s = 0 (fitted with 2 buttons).
Atention !!! This parameter does not basically affect the correct function
of guard.
Parametr
Value
Description
Basic
6
z
Switching off acoustic signalization
3
In default is status of Door phone signalling acoustically. It can cause a problem of
incorrect detection of tones by PBX. By parametr „z“ you can switch off this
acoustic signalization. The values are
z=0 – all signalling is switched off
z=1 – pick up and hang up tones are active only
z=2 – other tones active only (except pick up and hang up)
z=3 – all tones are active – default
Parametr
Value
Description
Basic
6*
t
Delay of line connection ( Siemens PBX)
1
The delay of line picks up ( OFF HOOK) for new PBX types (particularly
Siemens) is:
t=1 – standard operation
t=0 – delayed start
NUDV – Installation and Operating Instructions
28
4.8 Overview of Parameters
Parameter Value
Meaning
Basic
1
tt nn…
No. nn under button tt
-
2
tt nn…
No. nn under button tt
-
31
r m
switch r works in m mode
11 21
32
r hhhhhh pasw. hhhhhh for r switch in DAY + NIGHT
mode
-
33
r hhhhhh pasw. hhhhhh for r in DAY mode
-
34
r hhhhhh pasw. hhhhhh for r in NIGHT mode
-
35
r aa
command aa from phone after r switch
closing
155 266
36
r ss
ss period [sec] of r switch closing
105 205
37
r p
r switch control by incoming call
11 21
38
xx
xx period [sec] between switches 1 and 2
closing
10
41
v
choice type v – tone / pulse
0
42
z
sign for call extension
*
43
g bb
command for guard hanging up from phone
155 266
44
xxxx
service password
0000
45
dd
command for DAY switching
11
46
nn
command for NIGHT switching
10
47
e
mode of guard choice
1
48
c
keyboard connection
0
49
o
keyboard mode
0
40
d
dialing during talk
0
51
q
number of rings before guard call lifting up
2
52
d
maximum call time
2
53
w
time among button presses
2
54
z
time of hanging up when dialing repeated
2
55
z
time before dialing
1
56
hh
number of rings before hanging up
12
NUDV – Installation and Operating Instructions
29
57
t
DTMF tone duration (tone) choice
5 (100ms)
58
m
gap duration among DTMF tones
5 (100ms)
59
f
Flash duration
1 (100ms)
50
p
pause duration / interdigit gap
8 (800ms)
8#
#
basic setting
executes
81
deletes all numbers in
group 1 (Day mode)
82
deletes all numbers in
group 2 (Night mode)
83
basic setting only
for parameters 3x
only 3..
84
basic setting only
for parameters 4x
only 4..
85
basic setting only
for parameters 5x
only 5..
9
E N D
NUDV – Installation and Operating Instructions
30
4.9 List of Presetting Parameters
parameter
basic presettings
switch 1 mode
lock m=1
switch 2 mode
lock m=1
passw.Day+Night switch 1
not
passw. Day+Night switch 2
not
passw.Day switch 1
not
passw.Day switch 2
not
passw. Night switch 1
not
passw. Night switch 2
not
switch 1 activ. from phone
55
switch 2 activ. from phone
66
closing time of switch 1 and 2
5 sec
con. by incoming call
allowed
delay among ap. during oper.
10 sec
choice
DTMF
sign of call extension
*
hanging up from phone 1 / 2
55 / 66
service password
0000
switching to day mode
11
switching to night mode
10
guard choice mode
Day/Night
keyboard connection
no
keyboard mode
dialing
number of rings of incoming call
2
max. call time
2 min
time among button presses
2 sec
time of hanging up when dialing repeated
2 sec
time before dialing
1 sec
number of rings before hanging up
12
DTMF tone duration (tone) choice
100ms
gap duration among DTMF tones
100ms
Flash duration
100ms
pause duration / interdigit gap
800ms
Note: The minimum default setting can be customized by expected purchase
of min. 10pcs of NUDV.
NUDV – Installation and Operating Instructions
31
5 Technical Parameters
5.1 Electrical Parameters
Parameter
Value
Conditions
Minimum line current
18mA
line answered
Minimum line voltage
18V
line hang up
Voltage on line while guard
answers (VA characteristics)
< 8V
< 12V
I = 20mA
I = 60 mA
Leakage in hang up status
< 50uA
U = 60V
Impedance of line termination
130R +
820R paral. 220n
line answered
Band width
300Hz – 3400 Hz
20 - 60mA
Impedance of ringing
> 2Kohm
25 – 60 Hz
Sensitivity of ringing detector
min. 10 – 25 V
Pulse choice
40 / 60 ms
Tone choice level
4 a 6 dB
20 – 60 mA
Tone choice sensitivity
40 dB
20 – 60 mA
Sensitivity of tone detector
30 dB
20 – 60 mA
Power supply of lighting through,
switches and heating
12Vss ± 2V , 10-12Vst ± 2V
Max. consumption of lighting
through and heating
300mA
12Vss
Max. voltage of switch contact
48V
at I < 1A
Max. current of switch contact
2A
at U < 30 V
Operational temperature
- 20 to + 50°C
5.2 Mechanical dimensions
dimensions HxWxD [mm]
Type of item
1 module 2 modules 3 modules 4 modules
MKxx mount. box
114x118x45 204x118x45 294x118x45 384x118x45
KPDxx (on plast.)1col.
151x157x79 241x157x79 331x157x79 421x157x79
KPDxx (on plast.)2col.
-
241x286x79
-
421x286x79
Canopy xx
149x151x49 241x151x49 331x151x49 421x151x49
Fixing frame
147x151x3
239x151x3
299x151x3
399x151x3
NUDV – Installation and Operating Instructions
32
6 Table for Easy Programming
Complete the values in empty part of table you want to program. In double-frame
part there are whole programming commands, so the programming is very simple and
without errors. Furthermore such programmed values will be available for next changes
in manual.
Meaning
Programming sequence
Description
Spec.
par. Complete your values
num.
of
point
Number under button 1
Day/1gr.
101
16
Number under button 2
Day/1gr.
102
16
Number under button 3
Day/1gr.
103
16
Number under button 4
Day/1gr.
104
16
Number under button 5
Day/1gr.
105
16
Number under button 6
Day/1gr.
106
16
Number under button 7
Day/1gr.
107
16
Number under button 8
Day/1gr.
108
16
Number under button 9
Day/1gr.
109
16
Number under button 10
Day/1gr.
110
16
Number under button 11
Day/1gr.
111
16
Number under button 12
Day/1gr.
112
16
Number under button 1
Night/2gr.
201
16
Number under button 2
Night/2gr.
202
16
Number under button 3
Night/2gr.
203
16
Number under button 4
Night/2gr.
204
16
Number under button 5
Night/2gr.
205
16
Number under button 6
Night/2gr.
206
16
Number under button 7
Night/2gr.
207
16
Number under button 8
Night/2gr.
208
16
Number under button 9
Night/2gr.
209
16
Number under button 10
Night/2gr.
210
16
Number under button 11
Night/2gr.
211
16
Number under button 12
Night/2gr.
212
16
Switch 1 works in mode
m=1 - 4
311
1
Switch 2 works in mode
m=1 - 5
312
1
NUDV – Installation and Operating Instructions
33
Password for switch 1
Day+Night
321
6
Password for switch 2
Day+Night
322
6
Password for switch 1
Day
331
6
Password for switch 2
Day
332
6
Password for switch 1
Night
341
6
Password for switch 2
Night
342
6
Clos. of switch 1 fr. phone
351
2
Clos. of switch 2 fr. phone
352
2
Closing time of switch 1
[sec]
361
2
Closing time of switch 2
[sec]
362
2
Sw. cont.1 by incoming call
1 / 0
371
1
Sw. cont.2 by incoming call
1 / 0
372
1
Time between 1 and 2
switch closing
[sec]
38
2
Tone/pulse tone choice
1 / 0
41
1
Sign of call extension
* / #
42
1
Guard hang. up from phone
1.
431
2
Guard hang. up from phone
2.
432
2
Service password
44
4
Comm. to DAY switching
45
2
Comm. to NIGHT switching
46
2
Guard choice mode
1 / 0
47
1
Keyboard connection
0/1/2/3
48
1
Keyboard mode
1 / 0
49
1
DTMF during talk
0/1/2/3
40
1
Number of rings for ringing
51
1
Maximum call duration
[min]
52
1
Time among button press.
[sec]
53
1
Hang. up time when dialing
repeated
[sec]
54
2
Time before dialing start
[sec]
55
1
Num. of rings bef. hang. up
56
2
Duration of dialing tone
(n+5)x10
57
ms
1
Gap among DTMF tones
(n+5)x10
58
ms
1
Flash duration
nx100
59
ms
1
Pause durat. / interdigit gap
nx100
50
ms
1
NUDV – Installation and Operating Instructions
35
7 DECT – DistyBox
7.1 DistyBox Description
This module is a separate
box allowing the connection of
end
analogue
telecommunication device to
wireless system DECT – GAP
(e.g. Siemens line GigaSet,
TopCom line Butler etc.).
DistyBox is suitable for guard
connection, because it is not
necessary
to
place
the
conductors from house to the
gate and to address to base
station is enough sufficient. All
guard features are reserved.
DistyBox must be energized to power supply and the guards to outputs of
analogue line (indicated on figure) – both outputs of analogue line are parallel.
The DistyBox300 contains an internal antenna allowing the connection of 300
m direct visibility and 50 m in building. The DistyBox5000 can be fitted with an
external antenna increasing the range to 6 km.
7.2 DistyBox Signaling
LED indication
| Time interval is 8sec |
switched off
- no power supply
- ready to use and addressed to base station
- incoming searching call
- connection
- programming mode
- searching for base station
- base station found
- base station not found
Tones
- dial tone
- special dial tone (modulated)
- busy tone
- confirmation tone
- error tone
NUDV – Installation and Operating Instructions
36
7.3 DistyBox Programming
You can enter the programming mode 20 sec – 10min after power supply
ON by **9 choice (to dial/busy tones) namely after DistyBox power supply ON.
If you had entered a new PIN in previous programming (par.2) so now you
must enter a correct PIN for entry to programming (following main reset (par.
90) the PIN should not be entered). The special dialing tone is heard in
programming mode. The entry and correct PIN are confirmed by confirmation
tone, the false PIN by error tone.
Param.
Value
Meaning
**9
[xxxx]
entry to programming, xxxx=PIN, if entered
0
#
log off – stored DECT parameters will be deleted
1
xxxxxxxx # entry code to base station (4-8 numbers)
2
xxxx yyyy # PIN change - xxxx is old, yyyy is new, 0000 is firm one
3
0# - 79#
distance – number load is multiple of 130m (300m = 3)
40
0# / 1#
choice mode - 0 sends / 1 suppresses DTMF choice
transmission from base station (0 is pract. doubled choice)
41
0# / 1#
operational setting - 0 is phone / 1 is FAX
70
0# / 1# / 2# call limitation - 0 not limited, 1 incoming, 2 outcoming
71
0# / 1# / 2# type of call - 0 both, 1 internal, 2 external call
72
xxx #
Flash length – xxx times 10ms (100ms = 010) firm.=210ms
90
#
reset and company setting (bold), presets all
91
#
reset and company setting (bold), log in parameters will be
kept
92
0# / 1#
autoreset 0-inactive / 1-active (every 24 hrs will end all
transmissions and recall to base station)
Settings for use with guard: (90#), 401#, 410#, 700#, 710#
Internal call will be executed by **s, where s is 0-9 i.e. number of internal
station, station 9 may be called 10min after power supply ON, up to this
moment it is entry to programming.
Note: The switching of call/internal query can be made by “Flash” and **s
choices. The call will be switched over by hanging up. The “Flash” function will
turn back to previous call.
7.4 Log on to Base Station
The log in might be done automatically in this way that we hold the button for
searching on base station (min 3sec) and then we will connect the power
supply to DistyBox. This will automatically log on to base station within 1 min
and if not made it is recommended to make the company reset (90#) and
repeat logging on. Setting of parameters 401#, 410#, 700#, 710# is required.
Be sure about parameter 40, which is being set after company reset thus that
the choice is transmissed not only by guard, but also the base station so that
the choice is executed twice!!
The product was shop-checked. The producer guarantees that this product will
keep the features described in these operating instructions in the course of
guarantee provided that the user will be handled with it as described in the
operating manual. The guarantee will be extended by period of possible
guarantee repair.
When claiming in guarantee period please contact your dealer. The producer
only will make the guarantee repairs. Attach the description of claim reason,
proof of purchase and your exact address to the product.
The guarantee does not include:
•
mechanical, thermal, chemical and other damages caused by user’s
activities
•
defects caused by natural disasters
•
defects caused by repair or changes carried out by user or other
unauthorized person
•
willful damage of product
•
incorrect use of product caused by other use than specified in operating
manual (e.g. installation, programming)
•
damages caused during product transport to customer and from supplier
Producer:
Dealer:
Date of sale: